Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Searching for Clues for a Matter Dominated Universe in Liquid Argon Time Projection Chambers

Liquid Argon Time Projection Chambers (LArTPCs) represent one of the most widely utilized neutrino detection techniques in neutrino experiments, for instance, in the Short Baseline Neutrino (SBN) program and the future large-scale LArTPC: Deep Underground Neutrino Experiment (DUNE). The high-end technique, facilitating excellent spatial and calorimetric reconstruction resolution, also enables testing exotic Beyond Standard Model (BSM) theories, such as baryon number violation (BNV) processes (e.g., proton-decay, neutron-antineutron oscillation). At the same time, Machine Learning (ML) techniques have demonstrated their ubiquitous use in recent decades; ML techniques have also become some of the most powerful tools in high-energy physics (HEP) analyses. Furthermore, the development of algorithms to cater to the needs of problems in HEP (i.e., triggering, reconstruction, improving sensitivity, etc.) has also become an active area of research. By developing a combined approach using Convolutional Neural Network (CNN) and Boosted Decision Tree (BDT) techniques, the sensitivity of neutron-antineutron oscillation in DUNE is evaluated for a projected exposure of 400kton·years. Additionally, to meet the triggering requirement to select such rare events in DUNE, such a search is only supported with highly efficient self-triggering algorithms. An ML-based self-triggering scheme for large-scale LArTPCs, such as DUNE, is also developed with the intention of implementation on field-programmable gate arrays (FPGAs). The ML-based approach for searching for neutron-antineutron oscillation can be demonstrated and validated on the current LArTPC MicroBooNE. The analysis in MicroBooNE represents the first-ever search for neutron-antineutron oscillation in a LArTPC. DUNE's projected 90% C.L. sensitivity to the neutron antineutron oscillation lifetime is 6.45×10³² years, assuming 1.327×10³⁵ neutron·years, equivalent to 10 years of DUNE far detector exposure (400kton·years). For MicroBooNE, assuming 372 seconds of exposure (equivalent to 3.13×10³⁶ neutron·years), the 90% C.L. lifetime sensitivity is found at 3.07×10²⁵ yrs, after accounting for Monte-Carlo statistical uncertainty and systematic uncertainty from detector effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global Power System Transformation Consortium

The Global Power System Transformation (G-PST) Consortium, an expert- and practitioner-driven initiative, engages key power system operators, research and educational institutes, governments, businesses, and stakeholders in all regions of the world to accelerate clean energy transitions at the ambitious scope and scale that is required. The G-PST Consortium provides coordinated, holistic support and knowledge infusion for system operators pursuing clean energy transitions, including performing cutting-edge research; providing implementation support for world-class engineering and operational solutions; supporting workforce development; building and disseminating open-access data and tools; and accelerating localized technology adoption, standards development, and testing programs.

consortium↗

Status of the Fermilab Muon g - 2 Experiment

The muon anomalous magnetic moment, aµ = ( g - 2 )/2, is a low-energy observable which can be both measured and computed with very high precision, making it an excellent test of the Standard Model (SM) and a sensitive probe of new physics. Recent efforts improved the precision of both the theoretical prediction and the experimental measurement. On the theory side, the Muon g - 2 Theory Initiative, an international team of more than 130 physicists, reached in 2020 a consensus on the SM prediction for aµ. On the experimental side, the E989 Muon g - 2 Collaboration at Fermilab (FNAL) published in April 2021 a new measurement of aµ from the Run-1 dataset (2018) with 0.46 ppm precision, corroborating the previous Brookhaven National Laboratory (BNL) measurement and increasing the discrepancy with the SM value to 4.2 standard deviations. In this paper, I will discuss the experimental setup and report on the current status of the experiment.

Girotti, Paolo↗

The Muon g-2 Experiment at Fermilab

The muon magnetic anomaly, $a_{\mu}$, is a powerful test of the Standard Model of particle physics. A new experiment at Fermilab has recently measured $a_{\mu}$ with unprecedented precision, confirming the results of the earlier Brookhaven experiment and strengthening the tension with the prediction of the Standard Model as determined by dispersive methods. We here describe the experimental technique, recapitulate the recent result, and discuss some of the improvements made for subsequent analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon Campus at Fermilab

The Muon Campus at Fermilab provides world class accelerator infrastructure supporting the next generation intensity frontier experiments. The anti-proton source from the Tevatron era was converted to the present day Muon Campus at the end of the collider program in 2011. Currently, the Muon Campus delivers highly polarized muon beams to the Muon g-2 experiment and in a few years, it will provide muon beams to the Mu2e experiment. The Muon g-2 experiment is a high precision test of the standard model; it is precise enough to measure QED, Weak, and QCD Standard Model contributions.The Muon g-2 experiment looks for a significant deviation from the Standard Model whereas the Mu2e experiment looks for rare processes using high intensity muon beams. The Muon g-2 experiment has measured the anomalous magnetic moment of muons to an unprecedented 460 ppb precision with Run 1 data. The experiment has completed 5 runs, accumulating 19$\times$ Brookhaven E821 data set. The Mu2e experiment has completed the construction phase and first beam to the Diagnostic Absorber was run on April 14, 2022. Installation and commissioning of the Mu2e experiment will begin in 2023 and beam commissioning and physics run is currently planned for 2026.

43 PARTICLE ACCELERATORS↗

PV Inverter Failures Cause AC Breaker Damage - Power Quality

This poster discusses how PV inverter failures cause AC breaker damage and is intended to help system owners identify power quality issues and origins, help inverter and/or circuit breaker manufacturers develop safer failure modes, and develop addendums to standards for failure testing of breakers and inverters.

arc↗

Measurement of the muon anomalous precession frequency at the Muon g − 2 Experiment at Fermilab

The anomalous magnetic moment of the muon, $a_\mu = \frac{g-2}{2}$ is the fractional deviation of the muon $g$-factor from the value of 2. It emerges as the cumulative effect of the virtual particles participating in the muon interaction with a magnetic field via quantum loop corrections. Its value encodes all the possible interactions between the virtual particles and, for this reason, represents an important test of the Standard Model (SM). In particular, any deviation from the SM theoretical evaluation could be due to new physics contributions. The new Muon $g-2$ (E989) Experiment at Fermilab is currently operating to repeat and improve the previous E821 experiment at Brookhaven National Laboratory (BNL), aiming to reduce the experimental error by a factor of 4 to the final accuracy of 140 parts per billion (ppb). On April 7th, 2021, the E989 collaboration published the first result based on the first year of data taking (Run-1), measuring $a_\mu = 0.001~165~920~40(54)$ with a precision of 460 ppb. The measured value is consistent with the BNL measurement and strengthens the long-standing tension with the data-driven SM prediction to a combined discrepancy of 4.2$\sigma$. On the theory side, however, new efforts involving lattice-QCD techniques are starting to question the current consensus on the theoretical prediction, demanding new improvements on both the experimental and theoretical sides. The E989 collaboration is now finalizing the analysis of Run-2 and Run-3 data and a new publication is expected in the first half of 2023 with a combined statistical uncertainty of 200 ppb. The anomalous magnetic moment $a_\mu$ is measured as the ratio between the muon spin anomalous precession frequency, $\omega_a$, and the average magnetic field experienced by the muons as they circulate in the storage ring. This thesis presents a precession frequency analysis of the Run-1 data and an evaluation of the related systematic uncertainties. A new positron reconstruction developed for the analysis of the subsequent data-taking periods, aiming to reduce some of the major systematic uncertainties of the $\omega_a$ measurement, is presented. The author's involvement in the production of the Run-2/5 data and in the precise calibration of the detectors is discussed. Finally, the complete Run-1 $a_\mu$ result is presented.

43 PARTICLE ACCELERATORS↗

Generalizing mkFit and its Application to HL-LHC

mkFit is an implementation of the Kalman filter-based track reconstruction algorithm that exploits both thread- and data-level parallelism. In the past few years the project transitioned from the R&D phase to deployment in the Run-3 offline workflow of the CMS experiment. The CMS tracking performs a series of iterations, targeting reconstruction of tracks of increasing difficulty after removing hits associated to tracks found in previous iterations. mkFit has been adopted for several of the tracking iterations, which contribute to the majority of reconstructed tracks. When tested in the standard conditions for production jobs, speedups in track pattern recognition are on average of the order of 3.5x for the iterations where it is used (3-7x depending on the iteration). Multiple factors contribute to the observed speedups, including vectorization and a lightweight geometry description, as well as improved memory management and single precision. Efficient vectorization is achieved with both the icc and the gcc (default in CMSSW) compilers and relies on a dedicated library for small matrix operations, Matriplex, which has recently been released in a public repository. While the mkFit geometry description already featured levels of abstraction from the actual Phase-1 CMS tracker, several components of the implementations were still tied to that specific geometry. We have further generalized the geometry description and the configuration of the run-time parameters, in order to enable support for the Phase-2 upgraded tracker geometry for the HL-LHC and potentially other detector configurations. The implementation strategy and high-level code changes required for the HL-LHC geometry are presented. Speedups in track building from mkFit imply that track fitting becomes a comparably time consuming step of the tracking chain.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the muon spin precession frequency using the straw tracking detectors at the Fermilab Muon g-2 experiment

The measurement of the anomalous magnetic dipole moment of the muon ($a_{\mu}$) has long stood as an excellent precision test of the Standard Model (SM). The Fermilab Muon g-2 experiment has recently finished data-taking and in July 2023 published its latest determination of $a_\mu$ with a world-leading precision of 0.2\,ppm. In this publication, it surpassed the systematic uncertainty goal defined in the TDR. The analyses of a dataset approximately four times larger than this recent publication is now underway. The principle measurement of the Muon g-2 experiment measures $a_{\mu}$ by taking the ratio of two frequencies; the anomalous precession frequency ($\omega_a$) and the muon-weighted magnetic field of the experiment's storage ring measured from the precession frequency of protons in water using nuclear magnetic resonance (NMR) probes. In all publications to date, $\omega_a$ has been determined using energy deposits in the 24 calorimeters. However, the Fermilab experiment has t wo straw tracker detectors measuring the time and momentum of charged particles which can in principle also be used to to measure $\omega_a$ and such a measurement can provide an invaluable cross-check of the calorimeter result with different, and reduced, systematic uncertainties. This thesis presents the first (blinded) determination of $\omega_a$ using just charged tracks from the straw tracking detectors as opposed to calorimeter energy deposits. This analysis was undertaken using the Run-2/3 dataset which represents approximately 25\% of the final dataset. A total uncertainty of 2.19\,ppm on $\omega_a$ was obtained which is dominated by the statistical uncertainty of 2.16\,ppm. Additionally two new methodologies important to the analysis of the straw tracking data have been developed: one to better determine the track arrival time ($t_0$) and one to determine the level of pileup in the tracking detectors. The new $t_0$ algorithm which incorporates angular information improves t he resolution on the determination of the $t_0$ by a factor of two and results in 19\% more tracks being successfully reconstructed. The data from the trackers is also used to determine the beam profile that weights the magnetic field in the determination of $a_\mu$ and in determining several of the systematic uncertainties in the calorimeter-based $\omega_a$ analysis. A detailed study of the impact of the internal alignment of the tracker, the $t_0$ and pileup on the determination of the beam position was undertaken and propagated through to an uncertainty in the $\omega_a$ determination. These uncertainties were used in the Fermilab Muon g-2 experiment's recent publication in Phys. Rev. Lett.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam dynamics corrections in the measurement of the anomalous precession frequency at the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon with an accuracy of 140 ppb (parts per billions). This accuracy, obtained by adding in quadrature a statistical and a systematic contribution of comparable value (100 ppb), will allow to reduce the experimental uncertainty (from the previous E821 experiment at BNL \cite{bnl}) of a factor of 4, and represents one of the most precise tests of the Standard Model (SM) theory of elementary particles. The first result on the Run-1 dataset \cite{prl} was released on April 7, 2021, showing a very good agreement with the previous result from BNL experiment, with a slightly better uncertainty. The corresponding experimental average increases the significance of the discrepancy between the measured and Standard Model prediction of 4.2$\sigma$ \cite{white_paper}.\\ \noindent The measured quantity is the muon magnetic anomaly a$_\mu$=$\frac{g_\mu-2}{2}$ where g$_\mu$ is the gyromagnetic factor of the muon. Dirac's equation predicts g$_\mu$ = 2, while radiative corrections, dominated by the QED contribution due to an exchange of a virtual photon, causes a per-mille correction on this quantity. By including all the SM contributions, a$_\mu$ is known at 370 ppb. The E989 experiment measures $a_\mu$ injecting positive muons with momentum of 3.1 GeV/$c$ polarized longitudinally in bunches (called $fills$) with an average rate of 12 Hz, in a storage ring of 14 meters diameter. Due to the parity violation in the weak muon decay, high energy positrons produced are emitted preferably in the muon's spin direction. By counting the number of positrons with energy greater then 1.7 GeV in function of the time, the frequency precession of the muon spin is measured, that together with the measurement of the magnetic field, allows to extract $a_\mu$. The positrons are detected with 24 electromagnetic calorimeters, that measure the energy and the arrival time of the positrons, each made of 54 crystals of lead fluoride (PbF$_2$) read by silicon photomultipliers (SiPM). Together with calorimeters, two tracking detectors are used to make non-destructive measurements of the muon beam characteristic by reconstructing the muon decay position extrapolating backward the decay positrons. The knowledge of the beam motion inside the ring plays a fundamental role in the analysis of $a_{\mu}$, where the measured anomalous precession frequency $\omega_a$ must be corrected for four main beam dynamics effects. A first correction is associated with the presence of an electric field responsible of the vertical focusing on the storage ring, where vertical direction is orthogonal to the orbit and horizontal direction is along the storage ring radius. Due to the oscillations in the vertical direction, the so called vertical betatron oscillations, a second correction is necessary to account for an average angle associated with the muon motion off the ideal orbit. A third correction is caused by lost muons in the ring which have a different spin phase at the injection respect to the decay ones. Finally, due to the correlation between the vertical and horizontal beam motion of the muons and the acceptance of the calorimeter, a correction (called ``phase-acceptance") arises. In Run1, due to the presence of two damaged resistors in one electrostatic quadrupole, this correction had a prominent role. The replacement of the damaged resistors before Run2 decreased this effect by one order of magnitude, and a further reduction in Run-3 was provided by an improved orbit.\\ \noindent The work of this Thesis focuses on the beam dynamics corrections on $\omega_a$. Due to the prominent role in Run-1 a special attention has been put to the phase-acceptance correction\footnote{The effect of this correction on the E821 BNL measurement of the $g-2$ has been evaluated to be within the quoted systematic error.}. Chapter \ref{ch:anomalous_magnetic_moment} introduces the anomalous magnetic moment of the muon. Chapter \ref{ch:early_experiment} describes the history of the Muon $g-2$ experiments. Chapter \ref{ch:theory} discusses the Standard Model prediction and possible new physics scenario. Chapter \ref{ch:muon_g2_experiment} describes the E989 experiment, whose experimental technique and the apparatus are discussed focusing on the improvements needed to reach the final goal on $a_\mu$ measurement. The original work of the Thesis is discussed in the last 5 chapters. Chapter \ref{ch:experiment_technique} presents the analysis technique to extract $\omega_a$, Chapter \ref{ch:beam_dynamics} describes the beam dynamics in the E989 experiment, Chapter \ref{ch:beam_dynamics_correction} discusses the beam dynamics correction to $\omega_a$, and Chapter \ref{sec:pa_corr} focuses on the phase acceptance correction. Finally Chapter \ref{ch:run23_analysis_improvements} contains the Run-2/3 improvements which are expected to allow for an increased precision ons the beam dynamics co...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring the weak mixing angle at SBND

The weak mixing angle provides a sensitive test of the Standard Model. We study SBND's sensitivity to the weak mixing angle using neutrino-electron scattering events. We perform a detailed simulation, paying particular attention to background rejection and estimating the detector response. We find that SBND can provide a reasonable constraint on the weak mixing angle, achieving 8% precision for $10^{21}$ protons on target, assuming an overall flux normalization uncertainty of 10%. This result is superior to those of current neutrino experiments and is relatively competitive with other low-energy measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physical Properties of Hilti HIT-RE 500 V3 After Irradiation: Slant Shear, Tensile, Flexural, and Compressive

There are various applications in which epoxy adhesives may be used within hot-cell environments. These epoxies currently see limited use within hot cells since it is known that organics see degradation after small doses even as low as 50 kilogray (kGy). These losses in physical property strengths limit the use of these epoxies to non-structural applications. In modern construction, however, the use of epoxies to bond structural components such as rebar or threaded anchors is becoming increasingly prevalent. To employ these types of materials the Idaho National Laboratory (INL) has begun investigating the specific degradation properties of epoxies for use in structural applications in environments where radiation is present. Hilti HIT-RE 500 V3 is used extensively in new construction and renovation projects across the world. The INL has conducted various tests on this epoxy for low dose environments. These tests include tensile, flexural, compression, and slant shear tests following the American Society for Testing Material International (ASTM) standards D638, D790, D695, and C882/882M respectively. Two sample sets for each test were created where the baseline specimens were not irradiated, and another set was irradiated to an accumulated dose of approximately 50-60 kGy. All the samples were destructively tested and analyzed focusing on the change in physical properties, examples of these tests are shown in Figures 1-4. Tensile testing results indicate a 0.9% loss in maximum load capacity, a 0.5% loss in tensile stress at maximum load, a 1.4% loss in tensile strain at break, and a 15% decrease in modulus of elasticity. Flexural testing results display an increase in all the following: 12% in strain at maximum load, 10% in maximum load capacity, 5% in stress at maximum load, and 3% in young’s modulus. The compressive physical properties after irradiation display a 1% increase in maximum load, a 3% decrease in stress at yield, and a 5% decrease in modulus of elasticity. The maximum compressive stress saw no measurable change after irradiation. The slant shear specimens after irradiation displayed a 2% increase in maximum load capacity and maximum compressive stress. Though a structural analysis would have to be completed as is normal for building design the increases and decreases in the measured physical properties indicate that this material may be used for structural applications in low dose hot-cell environments without adhesive failure.

36 MATERIALS SCIENCE↗

MAIA: A new detector concept for a 10 TeV muon collider

Muon colliders offer a compelling opportunity to explore the TeV scale and conduct precision tests of the Standard Model, all within a relatively compact geographical footprint. This paper introduces a new detector concept, MAIA (Muon Accelerator Instrumented Apparatus), optimized for $\sqrt{s}=10$ TeV $\mu\mu$ collisions. The detector features an all-silicon tracker immersed in a 5T solenoid field. High-granularity silicon-tungsten and iron-scintillator calorimeters surrounding the solenoid capture high-energy electronic and hadronic showers, respectively, and support particle-flow reconstruction. The outermost subsystem comprises an air-gap muon spectrometer, which enables standalone track reconstruction for high-momentum muons. The performance of the MAIA detector is evaluated in terms of differential particle reconstruction efficiencies and resolutions. Beam-induced background (BIB) simulations generated in FLUKA are overlaid with single particle gun samples to assess detector reconstruction capabilities under realistic experimental conditions. Even with BIB, reconstruction efficiencies exceed 95% for energetic tracks, photons, and neutrons in the central region of the detector. This paper outlines promising avenues of future work, including forward region optimization and opportunities for enhanced flavor/boosted object tagging, and addresses the technological assumptions needed to achieve the desired detector performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the anomalous precession frequency in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low energy observable that can be both measured and computed with high precision, therefore it can provide an important test of the Standard Model and it is a sensitive probe for new physics. In particular, any discrepancy between the experimental value and the theoretical prediction can be due to Beyond Standard Model physics contribution. The E989 Muon $g-2$ Experiment at Fermilab aims to measure $a_\mu$ with a precision of 140 parts per billion, four time more precisely than the previous experiment at Brookhaven National Laboratory (BNL). E989 seeks to either resolve or confirm the observed discrepancy of $3.7\sigma$ between the Standard Model value and the experimental one. The $a_\mu$ measurement requires a precise determination of both the muon spin anomalous precession frequency and the average magnetic field seen by the muons as they circulate in a storage ring. The anomalous precession frequency measurement is b ased on the time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters placed around the inner circumference of the ring, while the magnetic field is constantly monitored by NMR probes. Last spring, E989 has published a new measurement of $a_\mu$ from the 2018 data-taking campaign, confirming the previous BNL value with comparable precision, bringing the discrepancy with the theoretical value to $4.2\sigma$. The candidate worked on the measurement of the anomalous precession frequency and on the estimate of the related systematic uncertainties of the 2018 data, giving an important contribution to the data analysis. The result presented in chapters 4 and 5 of this dissertation was included, among three other analyses, to determine the estimate of the anomalous magnetic moment by the Muon g-2 experiment. This work will present the anomalous precession frequency analysis technique and its result, the related systematics and finally the latest $a_\mu$ result.

Sorbara, Matteo↗

Cluster Dynamics Modeling Needs for the Advanced Materials and Manufacturing Technologies Program

This milestone report aims to identify and assess the cluster dynamics (CD) modeling requirements within the Department of Energy's Office of Nuclear Energy (DOE-NE) Advanced Materials and Manufacturing Technologies (AMMT) program and to communicate these needs to the DOE-NE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. The goal is to ensure NEAMS is well-informed about the CD modeling requirements to support AMMT's mission of accelerating the development, qualification, demonstration, and deployment of advanced structural materials and manufacturing for nuclear energy applications. CD modeling is an essential tool for predicting the degradation of structural materials under irradiation, which is a key component of AMMT's accelerated qualification process. The AMMT program focuses on both additively manufactured and wrought structural alloys, such as laser powder-bed fusion 316H austenitic stainless steel, alloy 709, Haynes 244, and alloy 617. These materials require a generalized CD modeling framework to facilitate rapid model development and computational simulation. A flexible, generalized CD software, similar to the Multiphysics Object-Oriented Simulation Environment (MOOSE) finite element framework, would enable modeling of various cluster types, including defect clusters, defect-solute clusters, and multicomponent clusters, incorporating thermodynamics and kinetics parameters. Radiation effects, microstructural feature evolution, and multi-dimensional modeling are critical considerations for the CD model. The usability of the CD code should allow for easy modification and coupling with MOOSE-based simulations. Additionally, the software should adhere to Nuclear Quality Assurance-1 standards, include a testing suite for verification and validation, and be version-controlled within a national laboratory-managed Git repository. Benchmark problems are needed to assess code predictions and performance.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Temperature Testing of Advanced Manufactured Melt Wire Package

As a part of the In-Pile Instrumentation Program, The Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced manufactured sensors for measuring the peak irradiation temperature inside a nuclear test reactor. Although nuclear test reactors can use standard methods of real-time temperature monitoring, such as thermocouples, the complexity of feedthroughs and attachment complications to collect real-time measurements greatly increases the cost of the experiment. Passive monitoring techniques may be utilized that exploit the melting point of well characterized material (standard melt wires), however, the limited space available for instrumentation during experiments is also a challenge. To accommodate the challenge, INL has expanded its temperature detection instrumentation capabilities paired with the advancement of in-house advanced manufacturing options to include printed melt wires for peak irradiation temperature measurement. The advanced manufactured melt wire package can determine peak temperatures in experiments that can fit the challenging space available during irradiation. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing. This report summarizes the initial temperature testing using fabricated melt wires with two different melting temperatures, silver (melting temperature of ~960 °C) and solder (melting temperature of ~160 °C), that were initially tested for their relative melting points using non-standard method of furnace and hot plate testing under normal air conditions. Future work will include more controlled way of testing printed melt wires under inert gas with multiple temperature measurements followed by comparison of standard melt wire package performance for baseline characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suggested Modifications for Bifacial Capacity Testing

Capacity tests such as those described in ASTM 2848 and IEC 61724-2 are widely used during the contracting and acceptance testing of photovoltaic systems. With the increasing deployment of bifacial photovoltaic modules, there is a need to develop a standardized approach to capacity test these systems. Although variability and bias error were inherently higher for the measured capacity of bifacial systems, they could be reduced to a level consistent with the monofacial reference system by appropriate incorporation of rear irradiance—either measured or modeled. Three field installations provided bifacial system capacity that was measured with a mean bias error and standard deviation within 1% over the 2–10-month observation period. Capacity test accuracy could be improved further by using the measured back-of-module temperature and the IEC 61724-2 test method for well curated systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗