Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing metrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Examination of a Rotorcraft Noise Prediction Method and Comparison to Flight Test Data

With a view that rotorcraft noise should be included in the preliminary design process, a relatively fast noise prediction method is examined in this paper. A comprehensive rotorcraft analysis is combined with a noise prediction method to compute several noise metrics of interest. These predictions are compared to flight test data. Results show that inclusion of only the main rotor noise will produce results that severely underpredict integrated metrics of interest. Inclusion of the tail rotor frequency content is essential for accurately predicting these integrated noise metrics.

Boyd, D. Douglas, Jr.↗

Prediction of Visual Acuity from Wavefront Aberrations

A method for generating a visual acuity metric, based on wavefront aberrations (WFAs), associated with a test subject and representing classes of imperfections, such as defocus, astigmatism, coma and spherical aberrations, of the subject's visual system. The metric allows choices of different image template, can predict acuity for different target probabilities, can incorporate different and possibly subject-specific neural transfer functions, can predict acuity for different subject templates, and incorporates a model of the optotype identification task.

Watson, Andrew B.↗

An Overall Assessment of JPSS-2 VIIRS Radiometric Performance Based on Pre-Launch Testing

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the second Joint Polar Satellite System (JPSS) completed its sensor level testing in February 2018. The JPSS-2 (J2) mission is scheduled to launch in 2022 and will be very similar to its two predecessor missions, the Suomi National Polar-orbiting Partnership (SNPP) mission, launched on 28 October 2011 and JPSS-1 (renamed NOAA-20) launched on 18 November 2017. VIIRS instrument has 22 spectral bands covering the spectrum between 0.4 and 12.6 μm: 14 reflective solar bands (RSB), 7 thermal emissive bands (TEB) and one day-night band (DNB). It is a cross-track scanning radiometer capable of providing global measurements through observations at two spatial resolutions, 375 m and 750 m at nadir for the imaging bands and moderate bands, respectively. This paper will provide an overview of J2 VIIRS characterization methodologies and calibration performance during the pre-launch testing phases performed by the National Aeronautics and Space Administration (NASA) VIIRS Characterization Support Team (VCST) to evaluate the at-launch baseline radiometric performance and generate the parameters needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). Our analysis results confirmed the good performance of J2 VIIRS, in general as good as previous VIIRS instruments and all non-compliances are expected to have low impact on data quality. Key sensor performance metrics include the signal to noise ratio (SNR), radiance dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, spectral performance, response versus scan-angle (RVS) and scattered light response. A set of performance metrics generated during the pre-launch testing program will be compared to both the SNPP and JPSS-1 VIIRS sensors.

Oudrari, Hassan↗

Novel Approach for Correlating Capacitance Data with Performance During Thin-Film Device Stress Studies: Preprint

A new data mining algorithm was developed to identify the strongest correlations between capacitance data (measured between -1.5 V and +0.49 V) and 1st and 2nd level performance metrics (efficiency, open-circuit voltage (VOC), short-circuit current density (JSC), and fill-factor (FF)) during the stress testing of voltage-stabilized CdS/CdTe devices. When considering only correlations between 1stand 2nd level metrics, 96.5% of the observed variation in efficiency was attributed to FF. The overall decrease in VOC after 1000 hours of open-circuit, light-soak stress at 60 degrees C was about 1.5%. As determined by our algorithm, the most consistent correlation existing between FF and 3rd level metric capacitance data at all stages during stress testing was between FF and the apparent CdTeacceptor density (Na) calculated at a voltage of +0.49 V during forward voltage scans. Since the contribution of back contact capacitance to total capacitance increases with increasing positive voltage, this result suggests that FF degradation is associated with decreases in Na near the CdTe/back contact interface. Also of interest, it appears that capacitance data at these higher voltagesappears to more accurately fit the one-sided abrupt junction model.

14 SOLAR ENERGY↗

MABAL: a Novel Deep-Learning Architecture for Machine-Assisted Bone Age Labeling

Bone age assessment (BAA) is a commonly performed diagnostic study in pediatric radiology to assess skeletal maturity. The most commonly utilized method for assessment of BAA is the Greulich and Pyle method (Pediatr Radiol 46.9:1269–1274, 2016; Arch Dis Child 81.2:172–173, 1999) atlas. The evaluation of BAA can be a tedious and time-consuming process for the radiologist. As such, several computer-assisted detection/diagnosis (CAD) methods have been proposed for automation of BAA. Classical CAD tools have traditionally relied on hard-coded algorithmic features for BAA which suffer from a variety of drawbacks. Recently, the advent and proliferation of convolutional neural networks (CNNs) has shown promise in a variety of medical imaging applications. There have been at least two published applications of using deep learning for evaluation of bone age (Med Image Anal 36:41–51, 2017; JDI 1–5, 2017). However, current implementations are limited by a combination of both architecture design and relatively small datasets. The purpose of this study is to demonstrate the benefits of a customized neural network algorithm carefully calibrated to the evaluation of bone age utilizing a relatively large institutional dataset. In doing so, this study will aim to show that advanced architectures can be successfully trained from scratch in the medical imaging domain and can generate results that outperform any existing proposed algorithm. The training data consisted of 10,289 images of different skeletal age examinations, 8909 from the hospital Picture Archiving and Communication System at our institution and 1383 from the public Digital Hand Atlas Database. The data was separated into four cohorts, one each for male and female children above the age of 8, and one each for male and female children below the age of 10. The testing set consisted of 20 radiographs of each 1-year-age cohort from 0 to 1 years to 14–15+ years, half male and half female. The testing set included left-hand radiographs done for bone age assessment, trauma evaluation without significant findings, and skeletal surveys. A 14 hidden layer-customized neural network was designed for this study. The network included several state of the art techniques including residual-style connections, inception layers, and spatial transformer layers. Data augmentation was applied to the network inputs to prevent overfitting. A linear regression output was utilized. Mean square error was used as the network loss function and mean absolute error (MAE) was utilized as the primary performance metric. MAE accuracies on the validation and test sets for young females were 0.654 and 0.561 respectively. For older females, validation and test accuracies were 0.662 and 0.497 respectively. For young males, validation and test accuracies were 0.649 and 0.585 respectively. Finally, for older males, validation and test set accuracies were 0.581 and 0.501 respectively. The female cohorts were trained for 900 epochs each and the male cohorts were trained for 600 epochs. An eightfold cross-validation set was employed for hyperparameter tuning. Test error was obtained after training on a full data set with the selected hyperparameters. Using our proposed customized neural network architecture on our large available data, we achieved an aggregate validation and test set mean absolute errors of 0.637 and 0.536 respectively. To date, this is the best published performance on utilizing deep learning for bone age assessment. Our results support our initial hypothesis that customized, purpose-built neural networks provide improved performance over networks derived from pre-trained imaging data sets. We build on that initial work by showing that the addition of state-of-the-art techniques such as residual connections and inception architecture further improves prediction accuracy. This is important because the current assumption for use of residual and/or inception architectures is that a large pre-trained network is required for successful implementation given the relatively small datasets in medical imaging. Instead we show that a small, customized architecture incorporating advanced CNN strategies can indeed be trained from scratch, yielding significant improvements in algorithm accuracy. It should be noted that for all four cohorts, testing error outperformed validation error. One reason for this is that our ground truth for our test set was obtained by averaging two pediatric radiologist reads compared to our training data for which only a single read was used. This suggests that despite relatively noisy training data, the algorithm could successfully model the variation between observers and generate estimates that are close to the expected ground truth.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Diode Analysis and Verification (Professional Report)

The goal of this project at Lawrence Livermore National Laboratory (LLNL) was focused on analyzing and verifying laser diodes to ensure that the diodes meet requirements for LLNL mission applications. The different stages of this testing were documented in a process flow map which included location color coding so that each step was clearly defined in scope and location of appropriate testing facility. Data were collected and analyzed and compared to minimum acceptable values to see if requirements were met. The process map documents the initial receipt, inspection, and testing of the laser diodes. Initial inspections started with Keyence Microscope imaging and then moved on to High Potential, Ramp, and Burst Testing. Data from the diode testing were processed through MATLAB and Python codes to verify various metrics such as slope efficiency, threshold current, back irradiance, and beam divergence met requirements. These metrics were then recorded in Excel summary reports. Approximately 95% of the laser diodes passed all tests. Presentations were given to Lawrence Livermore’s internal leadership team, an external partner, and to a Lab-wide audience. The data released for this report was constrained by information protection considerations of LLNL’s national security missions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chemical cleaning of porous stainless steel cross-flow filter elements for nuclear waste applications

The Waste Treatment and Immobilization Plant (WTP) currently under construction for treatment of High-Level Waste (HLW) at the Hanford Site will rely on cross-flow ultrafiltration to provide solids-liquid separation as a core part of the treatment process. To optimize process throughput, periodic chemical cleaning of the porous stainless steel filter elements has been incorporated into the design of the plant. It is currently specified that chemical cleaning with nitric acid will occur after significant irreversible membrane fouling is observed. Irreversible fouling is defined as fouling that cannot be removed by backpulsing the filter. PNNL has investigated chemical cleaning processes as part of integrated tests with HLW simulants and with actual Hanford tank wastes. To quantify the effectiveness of chemical cleaning, the residual membrane resistance after cleaning was compared against the initial membrane resistance for each test in a series of long-term fouling tests. The impact of the small amount of residual resistance in these tests could not be separated from other parameters and the historical benchmark of >1 GPM/ft2 for clean water flux was determined to be an adequate metric for chemical cleaning. Using the results from these tests, a process optimization strategy is presented suggesting that for the simulant material under test, the value of chemical cleaning may be suspect. The period of enhanced filtration may not be enough to offset the down time required for chemical cleaning, without respect to the other associated costs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Use of Dynamic Visual Acuity as a Functional Test of Gaze Stabilization Following Space Flight

After prolonged exposure to a given gravitational environment the transition to another is accompanied by adaptations in the sensorimotor subsystems, including the vestibular system. Variation in the adaptation time course of these subsystems, and the functional redundancies that exist between them make it difficult to accurately assess the functional capacity and physical limitations of astro/cosmonauts using tests on individual subsystems. While isolated tests of subsystem performance may be the only means to address where interventions are required, direct measures of performance may be more suitable for assessing the operational consequences of incomplete adaptation to changes in the gravitational environment. A test of dynamic visual acuity (DVA) is currently being used in the JSC Neurosciences Laboratory as part of a series of measures to assess the efficacy of a countermeasure to mitigate postflight locomotor dysfunction. In the current protocol, subjects visual acuity is determined using Landolt ring optotypes presented sequentially on a computer display. Visual acuity assessments are made both while standing and while walking at 1.8 m/s on a motorized treadmill. The use of a psychophysical threshold detection algorithm reduces the required number of optotype presentations and the results can be presented immediately after the test. The difference between the walking and standing acuity measures provides a metric of the change in the subject s ability to maintain gaze fixation on the visual target while walking. This functional consequence is observable regardless of the underlying subsystem most responsible for the change. Data from 15 cosmo/astronauts have been collected following long-duration (approx. 6 months) stays in space using a visual target viewing distance of 4.0 meters. An investigation of the group mean shows a change in DVA soon after the flight that asymptotes back to baseline approximately one week following their return to earth. The performance of some subjects nicely parallels the stereotypical recovery curve observed in the group mean data. Others show dramatic changes in DVA from one test day to another. These changes may be indicative of a re-adaptation process that is not characterized by a steady improvement with the passage of time, but is instead a dynamic search for appropriate coordinative strategy to achieve the desired gaze stabilization goal. Ground-based data have been collected in our lab using DVA with one of the goals being to improve the DVA test itself. In one of these studies, the DVA test was repeated using a visual target viewing distance of 0.5 meters. While walking, the relative contributions of the otoliths and semi-circular canals that are required to stabilize gaze are affected by visual target viewing distance. It may be possible to exploit this using the current treadmill DVA test to differentially assess changes in these vestibular subsystems. The postflight DVA evaluations currently used have been augmented to include the near target version of the test. Preliminary results from these assessments, as well as the results from the ground-based tests will also be reported. DVA provides a direct measure of a subject's ability to see clearly in the presence of self-motion. The use of the current tests for providing a functionally relevant metric is evident. However, it is possible to expand the scope of DVA testing to include scenarios other than walking. A facility for measuring DVA in the presence of passive movements is being created. Using a mechanized platform to provide the perturbation, it should be possible to simulate aircraft and automobile vibration profiles. Used in conjunction with the far and near visual displays this facility should be able to assess a subject s ability to clearly see distant objects as well as those that appear on the dashboard or instrument control panel during functionally relevant situations.

Peters, B. T.↗

MetaBAT

Assembling individual genomes from shotgun metagenomic sequences derived from complex microbial communities is so far one of the most challenging problems in bioinformatics.As it is impractical to directly assemble full-length genomes, a first step that groups contigs from the same organisms, called metagenome binning, has been developed to provide insights of individual organisms. However, current binning methods perform poorly in the context of large complex community, and as a result they fail to recover many novel genomes. To overcome this limitation, we developed integrated software, called MetaBAT, which automatically forms hundreds of individual genome bins from metagenome contigs. Probabilistic models of abundance and tetranucleotide frequency were trained by extensive empirical studies and integrated to decide the membership of contigs iteratively. To test the performance of MetaBAT, we applied MetaBAT to both synthetic and several large-scale real world metagenome datasets. By using two independent metrics, we demonstrate that in all the data sets tested MetaBAT achieves good sensitivity (16~87%) and very high specificity (56~99%) in forming genome bins. Further analyses of the novel genomes recovered from the human gut microbiome suggest a subset of these genomes are potentially associated with pathological conditions. In conclusion, we believe MetaBAT is a powerful tool

Kang, Dongwan↗

Technical Report on Waveform Fit Metrics for Global Models

The new WAVEFORMS Initiative in the Ground-based Nuclear Detonation Detection (GNDD) program includes an increased emphasis on the development of Earth models and methods to predict entire seismic and acoustic waveforms more accurately. In general, this increased emphasis is predicated on the need to better characterize seismic events and provide improved model-based discrimination between event types including earthquakes and explosions. More specifically, while current moment tensor inversion methods tend to work well for larger events (M>~4) using tuned 1-D Earth models, the development of state-of-the-art 3-D models and methods is required for the prediction of shorter period waves over large areas for discrimination of smaller events. There is no standard metric for model-based waveform prediction accuracy used in the waveform modeling/inversion community. However, there are several popular waveform misfit definitions; and minimizing the corresponding objective functions is the goal of waveform inversion. Some example misfit definitions employed for adjoint waveform tomography include measures of simple travel time differences (e.g. Tape et al., 2010), cross-correlation travel time differences (e.g. Luo and Schuster, 1991), multi-taper frequency dependent methods (e.g. Lei et al., 2020), time-frequency phase misfit functions (e.g. Fichtner 2010; Rodgers et al., 2022), normalized cross-correlation methods (e.g. Tao et al., 2018), and others. In some cases, these misfit definitions also involve complicated weighting schemes and summations over multiple frequency bands making it difficult to duplicate the misfit measurement with alternative models and datasets. Although each of the misfit definitions mentioned above are useful for developing waveform models, the actual misfit values are not usually meaningful outside of a given project, model, and/or dataset. Therefore, it is difficult to understand and communicate model performance for predicting waveforms and comparing to other models and/or new model iterations with a different dataset. Therefore, there is a need for a generalized method for evaluating overall model performance that is independent from the specific misfit chosen to develop the waveform models that is also intuitive and meaningful. In this report, we describe a new metric we refer to as ‘Percent of Correlated Signal’. The following sections describe and demonstrate the metric with a case study event and a more rigorous test using a random selection of globally distributed events. While the focus here is on global tomography models, the metric is meant to applicable to regional ‘wiggle-for-wiggle’ waveform models/studies as well.

58 GEOSCIENCES↗

Model independent tests of the standard cosmological model

The dark energy problem has led to speculation that not only may {Lambda}CDM be wrong, but that the Friedmann-Lemaitre-Robertson-Walker models themselves may not even provide the correct family of background models. We discuss how direct measurements of H(z) can be used to formulate tests of the standard paradigm in cosmology. On their own, such measurements can be used to test for deviations from flat {Lambda}CDM. When combined with supernovae distances, Hubble rate measurements provide a test of the Copernican principle and the homogeneity assumption of the standard model, which is independent of dark energy or a metric based the theory of gravity. A modification of this test also provides a model independent observable for flatness which decorrelates curvature determination from dark energy. We investigate these tests using Hubble rate measurements from age data, as well as from a Hubble rate inferred from recent measurements of the baryon acoustic oscillations. While the current data are too weak to say anything significant, these tests are exciting prospects for the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Results of the 1000 Hour Rotary Microfilter Endurance Test

David Herman gives an overview of the 1000 Hour Rotary Microfilter Endurance Test performed at SRNL. The SpinTek Rotary Microfilter was tested with sludge washing and evaluated using performance metrics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

“One Table to Rule Them All”: How a Single Table can Enable Extensive Insights, Analytics and Assessment on Human Mobility Data

While much research has been conducted in Human Mobility Science, most studies on the analytics/insights part generally focus on one of the following: processing and analytics on human stop-trip behavior, design of individual mobility metrics (often in silos), calculation and characterization of only a handful (typically 5-6) of human mobility metrics on geospatial-temporal human mobility data of interest. Although human mobility research offers a vast and diverse array of available metrics, most individual studies typically compute only a small subset of five or six metrics at a time when analyzing trajectory datasets of human mobility across different areas of interest. This paper is motivated by the critical need to repeatedly compute an extensive array of human mobility metrics across several trajectory datasets and perform individual metric-level benchmarking to establish a new, standardized Test and Evaluation (T&E) suite for the field of Human Mobility Science. We first present our findings on the minimal yet sufficient pre-processing required to reliably and efficiently compute a wide range of human mobility metrics. The key findings are specifically related to the proposed Composite Stop Locations table, which serves as a core pre-processing data layer. Subsequently, we present a case study demonstrating how the Composite Stop Locations table facilitates computation of at least 14 distinct human mobility metrics (unlike 5-6 different set of metrics used for studies in the literature) using the popular and open-source OpenPFLOW dataset. Finally, we have also presented an example of our benchmarking methodology to evaluate the quality and performance of the trajectory dataset of interest, assessed across multiple human mobility metrics.

De, Debraj [ORNL] (ORCID:0000000233630020)↗

A Metric-Based Validation Process to Assess the Realism of Synthetic Power Grids

Public power system test cases that are of high quality benefit the power systems research community with expanded resources for testing, demonstrating, and cross-validating new innovations. Building synthetic grid models for this purpose is a relatively new problem, for which a challenge is to show that created cases are sufficiently realistic. This paper puts forth a validation process based on a set of metrics observed from actual power system cases. These metrics follow the structure, proportions, and parameters of key power system elements, which can be used in assessing and validating the quality of synthetic power grids. Though wide diversity exists in the characteristics of power systems, the paper focuses on an initial set of common quantitative metrics to capture the distribution of typical values from real power systems. The process is applied to two new public test cases, which are shown to meet the criteria specified in the metrics of this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Selected Test Results from the Encell Technology Nickel Iron Battery

The performance of the Encell Nickel Iron (NiFe) battery was measured. Tests included capacity, capacity as a function of rate, capacity as a function of temperature, charge retention (28-day), efficiency, accelerated life projection, and water refill evaluation. The goal of this work was to evaluate the general performance of the Encell NiFe battery technology for stationary applications and demonstrate the chemistry's capabilities in extreme conditions. Test results have indicated that the Encell NiFe battery technology can provide power levels up to the 6C discharge rate, ampere-hour efficiency above 70%. In summary, the Encell batteries have met performance metrics established by the manufacturer. Long-term cycle tests are not included in this report. A cycle test at elevated temperature was run, funded by the manufacturer, which Encell uses to predict long-term cycling performance, and which passed their prescribed metrics.

25 ENERGY STORAGE↗

Alstom’s Limestone Chemical Looping Gasification Process for High Hydrogen Syngas Generation

Alstom Power Inc., a wholly owned subsidiary of the General Electric Company (GE), is developing Limestone-based Chemical Looping (LCL™) Processes, utilizing limestone derived calcium sulfate as an oxygen carrier to transport oxygen from air to the fuel. The LCL™ process is a breakthrough technology with the potential to capture CO 2 and SO 2 from new and existing coal-fired power plants at reduced costs while maintaining high plant power generation efficiency. Chemical looping is a next generation advancement to oxy-combustion which would not require the significant investment in a cryogenic distillation type oxygen production plant. Instead of the energy-consuming oxygen plant, chemical looping uses a benign material to directly remove oxygen from the air and bring that oxygen into contact with the fuel. This "game changing" technology is the lowest cost-of-electricity technical approach that GE Power has identified to date for coal power with carbon capture. The technology has significantly lower capital costs compared to a conventional steam power plant with first generation carbon capture technologies. This new power plant concept is based on a hybrid combustion-gasification process utilizing high temperature chemical and thermal looping technology. In the air reactor, a solid oxygen carrier picks up oxygen from air through an oxidation reaction and leaves nitrogen behind. The hot oxygen-carrying solid carrier is then transported to a fuel reactor, where it releases oxygen. The released oxygen then converts the coal in the fuel reactor into combustion gases. The solid carrier is recycled back to the air reactor for regeneration completing the “chemical loop.” The regeneration step produces heat from which steam is produced for power generation while the process results in a concentrated carbon dioxide stream in which the carbon is captured for use or sequestration (CCUS). Limestone as a precursor for the oxygen carrier is abundant, benign, low cost, and is used in CFB and PC boilers for sulfur control. Challenges associated with this carrier include a complex reaction mechanism with possible side reactions leading to the release of SO 2 . The development of the Limestone Chemical Looping Gasification (LCL-G™) technology was co-funded by the Department of Energy under the DOE/NETL Cooperative Agreement No. DE- FE0023497, in parallel with the collaborative combustion (LCL-C™) program. In this report, the LCL-G™ experimental testing from the electrically-heated, once-through, 100 kW Pilot-Scale Test Facility (PSTF) is analysed and reviewed. The PSTF Oxidizer is a 50-foot tall, 100-mm diameter transport reactor, while the PSTF Reducer reactor is based upon a bubbling-bed design. The experimental data from four (4) test campaigns (denoted “Weeks”) are reviewed and discussed. The LCL-G™ (DE-FE0023497) project objectives for gasification are >90% carbon gasified in the Reducer and a H 2 :CO molar generation ratio of 2:1. These project performance metrics were not met by a single coal test, but they were individually approached in two separate tests.

01 COAL, LIGNITE, AND PEAT↗

Operational resilience metrics for power systems with penetration of renewable resources

Abstract Modern power grid is evolving towards carbon neutrality by deploying increasing amount of renewable energy resources. However, the impact of renewable generation on power system planning and operation is not sufficiently investigated, especially the capability of renewable penetrated power systems to resist and recover from major disturbances, which is a critical concern for system operators. Novel metrics and evaluation methodologies are needed to depict systems’ ability in response to events caused by natural disasters, and quantitatively evaluate system performance in various time scales. In this paper, operational resilience metrics are proposed for power systems with penetration of renewable energy resources based on transient stability principles. A systematic methodology is proposed to quantitatively assess the evolution of system performance during various stages of the disaster process. Based on the proposed metrics, a resilience‐oriented disaster management strategy is designed and validated using the modified IEEE 39‐bus test system. The simulation results demonstrate the validity of the proposed metrics and strategy, and show that the system resilience is enhanced during the mitigation of fault conditions.

Gui, Jianzhong↗

NASA JSC’s Simulant Development Lab Capabilities and Artemis Testing

The Simulant Development Lab (SDL) is a multifunctional collaborative workspace that supports the development, curation, analysis, testing, and distribution of planetary regolith simulants – including lunar, Martian, asteroidal, and other granular materials. The lab provides a multidisciplinary setting for scientific characterization of simulant physical properties and for engineering evaluations conducted with simulant test beds. To enable this work, the SDL curates and maintains a stock of more than 35 metric tons of simulant material. To evaluate these materials and support testing goals, the lab is equipped with a comprehensive suite of processing tools and analytical instruments. These capabilities enable the SDL’s mission at NASA’s Johnson Space Center to distribute, develop, process, characterize, and test regolith simulants for mission relevant applications. Through controlled and repeatable testing environments that replicate the physical and compositional properties of lunar regolith, the SDL supports Artemis hardware maturation, providing safe, Earth‑based analogs for evaluating systems that must withstand regolith dust interactions, physical wear and abrasion, and operational loads. The facility’s extensive simulant inventory and integrated geological and engineering test infrastructure accelerate technology readiness for Artemis and future exploration campaigns (e.g., future crewed or robotic missions to Mars).

Simulant Development Lab↗