Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Thermal diffusivity measurements using a pulsed dual-beam thermal lens technique

A novel pulsed dual-beam thermal lens technique for the determination of thermal diffusivity of liquids and solids was developed. In this technique a transient thermal lens is formed in the test specimen by using a dye laser pulse as a heating source and the thermal lens decay is monitored by means of a CW He-Ne laser. The technique is fast and contactless and avoids some of the major difficulties of conventional methods. Thermal diffusivities for water and a polycarbonate plastic were measured and found to be in agreement with literature values. Considerable simplification and minimization of certain errors was achieved by use of a reference material.

Gupta, M. C.↗

Element-by-element factorization algorithms for heat conduction

Element-by-element solution strategies are developed for transient heat conduction problems. Results of numerical tests indicate the effectiveness of the procedures proposed. The small database requirements and attractive architectural features of the algorithms suggest considerable potential for solving large scale problems.

Hughes, T. J. R.↗

Overview of Aerothermodynamic Loads Definition Study

The Aerothermodynamic Loads Definition were studied to develop methods to more accurately predict the operating environment in the space shuttle main engine (SSME) components. Development of steady and time-dependent, three-dimensional viscous computer codes and experimental verification and engine diagnostic testing are considered. The steady, nonsteady, and transient operating loads are defined to accurately predict powerhead life. Improvements in the structural durability of the SSME turbine drive systems depends on the knowledge of the aerothermodynamic behavior of the flow through the preburner, turbine, turnaround duct, gas manifold, and injector post regions.

Povinelli, L. A.↗

Laminar diffusion flames under micro-gravity conditions

Laminar methane and propane gas-jet diffusion flames have been theoretically and experimentally studied at NASA-Lewis under microgravity conditions. It is noted that laminar diffusion flames are strongly affected by the combined effects of kinetics, radiation, and such transient phenomena as flame ignition, stabilization, and extinction. Observations on the distinctive nature of the flame color and luminosity parameters in microgravity are presented, and flame behavior under transient, high-deceleration rates is discussed. Test hardware and instrumentation design are described.

Edelman, Raymond B.↗

Enhancement of the no-vent fill process

This paper presents an analytical and experimental evaluation of an enhanced techniques for no-vent fill. The method entails injecting liquid through the top of the receiver vessel, thereby increasing surface area and agitation of the ullage/liquid interface. Both of these factors promote condensation induced ullage collapse, and reduce compressive impedance to the incoming liquid. The enhanced process was analyzed by modifying the surface area algorithm of an existing tank thermodynamic code to model a downward-pointing, conical jet impringing on a steadily rising liquid surface. Transient pressure and temperature measurements from several tests with Freon-114 were input into the revised model to calculate condensation rate as a function of fill level. By expressing these rates in dimensionless form (i.e., in terms of Stanton number and Prandtl number), an empirical correlation similar to the submerged jet model of Brown and Sonin (1989) was derived. This provided a basis for developing an expression which relates top fill to bottom fill performance.

Vaughan, David A.↗

Nonlinear dynamic simulation of single- and multi-spool core engines

In this paper a new computational method for accurate simulation of the nonlinear dynamic behavior of single- and multi-spool core engines, turbofan engines, and power generation gas turbine engines is presented. In order to perform the simulation, a modularly structured computer code has been developed which includes individual mathematical modules representing various engine components. The generic structure of the code enables the dynamic simulation of arbitrary engine configurations ranging from single-spool thrust generation to multi-spool thrust/power generation engines under adverse dynamic operating conditions. For precise simulation of turbine and compressor components, row-by-row calculation procedures were implemented that account for the specific turbine and compressor cascade and blade geometry and characteristics. The dynamic behavior of the subject engine is calculated by solving a number of systems of partial differential equations, which describe the unsteady behavior of the individual components. In order to ensure the capability, accuracy, robustness, and reliability of the code, comprehensive critical performance assessment and validation tests were performed. As representatives, three different transient cases with single- and multi-spool thrust and power generation engines were simulated. The transient cases range from operating with a prescribed fuel schedule, to extreme load changes, to generator and turbine shut down.

Schobeiri, T.↗

Geoscience Laser Altimeter System (GLAS) Final Test Report of DM LHP TV Testing

Two loop heat pipes (LHPs) are to be used for thermal control of the Geoscience Laser Altimeter System (GLAS), planned for flight in 2001. One LHP will be used to transport 100 W from a laser to the radiator, the other will transport 210 W from electronic boxes to the radiator. In order to verify the LHP design for the GLAS application, an LHP Development Model has been fabricated, and ambient and thermal vacuum tested. Two aluminum blocks of 15 kg and 30 kg, respectively, were attached to the LHP to simulate the thermal masses connected to the heat sources. A 20 W starter heater was installed on the evaporator to aid the loop startup. A new concept to thermally couple the vapor and liquid line was also incorporated in the LHP design. Such a thermal coupling would reduce the power requirement on the compensation chamber in order to maintain the loop set point temperature. To avoid freezing of the liquid in the condenser during cold cases, propylene was selected as the working fluid. The LHP was tested under reflux mode and with adverse elevation. Tests conducted included start-up, power cycle, steady state and transient operation during hot and cold cases, and heater power requirements for the set point temperature control of the LHP. Test results showed very successful operation of the LHP under all conditions. The 20 W starter heater proved necessary in order to start the loop when a large thermal mass was attached to the evaporator. The thermal coupling between the liquid line and the vapor line significantly reduced the heater power required for loop temperature control, which was less than 5 watts in all cases, including a cold radiator. The test also demonstrated successful operation with a propylene working fluid, with successful startups with condenser temperatures as low as 100 C. Furthermore, the test demonstrated accurate control of the loop operating temperature within +/- 0.2 C, and a successful shutdown of the loop during the survival mode of operation.

Baker, Charles↗

Analog Techniques for Measuring the Frequency Response of Linear Physical Systems Excited by Frequency-Sweep Inputs

Data-reduction methods using general-purpose analog computer equipment and compatible testing techniques for determining the frequency response of linear physical systems are examined. The techniques considered may be classed as steady state or transient depending on the method of excitation. The relative merits of periodic, slow sweep, and transient (rapid sweep) forcing functions are discussed and applications are given that relate to dynamic-response tests of aeroelastic systems. Two frequency-sweep-input methods are considered in detail. one case the sweep rate is sufficiently slow that the response is approximately the same as that for steady-state conditions. With this input the frequency response can be evaluated and displayed in real time while the test is in progress. Errors due to treating sweep data as steady state can be eliminated, when desired, by reanalyzing tape-recorded time histories of the input and output as transient rather than as periodic data. In the second method the frequency-response function is deter- mined from the system's transient response to a very rapid sweep input. The purpose of frequency sweep in this case is to provide sufficient harmonic content in the input to overcome noise while keeping the test time as short as possible. tests and limited flight-test data presented herein, it appears that a transient-type rapid-sweep forcing function offers a considerable saving in test time while preserving the accuracy possible with steady-state sinusoidal inputs.

Wilmer H. Reed III↗

Digital implementation of the TF30-P-3 turbofan engine control

The standard hydromechanical control modes for TF30-P-3 engine were implemented on a digital process control computer. Programming methods are described, and a method is presented to solve stability problems associated with fast response dynamic loops contained within the exhaust nozzle control. A modification of the exhaust nozzle control to provide for either velocity or position servoactuation systems is discussed. Transient response of the digital control was evaluated by tests on a real time hybrid simulation of the TF30-P-3 engine. It is shown that the deadtime produced by the calculation time delay between sampling and final output is more significant to transient response than the effects associated with sampling rate alone. For the main fuel control, extended update and calculation times resulted in a lengthened transient response to throttle bursts from idle to intermediate with an increase in high pressure compressor stall margin. Extremely long update intervals of 250 msec could be achieved without instability. Update extension for the exhaust nozzle control resulted in a delayed response of the afterburner light-off detector and exhaust nozzle overshoot with resulting fan oversuppression. Long update times of 150 msec caused failure of the control due to a false indication by the blowout detector.

Cwynar, D. S.↗

Single event test methodology for integrated optoelectronics

A single event upset (SEU), defined as a transient or glitch on the output of a device, and its applicability to integrated optoelectronics are discussed in the context of spacecraft design and the need for more than a bit error rate viewpoint for testing and analysis. A methodology for testing integrated optoelectronic receivers and transmitters for SEUs is presented, focusing on the actual test requirements and system schemes needed for integrated optoelectronic devices. Two main causes of single event effects in the space environment, including protons and galactic cosmic rays, are considered along with ground test facilities for simulating the space environment.

Label, Kenneth A.↗

Turbopumps for cryogenic upper stage engines

Small, high-performance LO2 and LH2 turbopump assembly configurations were selected, detail designs were prepared and two of each unit were fabricated with each unit consisting of pump, turbine gas generator, and appropriate controls. Following fabrication, development testing was conducted on each type to demonstrate performance, durability, transient characteristics, and heat transfer under simulated altitude conditions. Following successful completion of development effort, the two LO2 turbopump units and one LH2 turbopump unit were acceptance tested as specified. Inspection of the units following development testing revealed no deleterious effects of testing. The test results of LO2 turbopump assembly testing correlated well with predicted performance while the LH2 turbopump test results, though generally consistent with predicted values, did show lower than anticipated developed head at the design point and in the high flow range of operation.

Zachary, A. T.↗

Magnetic bearings for a spaceflight optical disk recorder

The development and testing of a magnetic bearing system for the translator of the read/write head in a magneto-optic disk drive are discussed. The asymmetrical three-pole actuators with permanent magnet bias support the optical head, and its tracking and focusing servos, through their radial excursion above the disk. The specifications for the magnetic bearing are presented, along with the configuration of the magnetic hardware. Development of a five degree of freedom collision model is examined which allowed assessment of the system response during large scale transients. Experimental findings and the results of performance testing are presented, including the roll-off of current-to-force due to eddy current loss in the magnetic materials.

Hockney, Richard↗

Miniature Convection Cooled Plug-type Heat Flux Gauges

Tests and analysis of a new miniature plug-type heat flux gauge configuration are described. This gauge can simultaneously measure heat flux on two opposed active surfaces when heat flux levels are equal to or greater than about 0.2 MW/m(sup 2). The performance of this dual active surface gauge was investigated over a wide transient and steady heat flux and temperature range. The tests were performed by radiatively heating the front surface with an argon arc lamp while the back surface was convection cooled with air. Accuracy is about +20 percent. The gauge is responsive to fast heat flux transients and is designed to withstand the high temperature (1300 K), high pressure (15 MPa), erosive and corrosive environments in modern engines. This gauge can be used to measure heat flux on the surfaces of internally cooled apparatus such as turbine blades and combustors used in jet propulsion systems and on the surfaces of hypersonic vehicles. Heat flux measurement accuracy is not compromised when design considerations call for various size gauges to be fabricated into alloys of various shapes and properties. Significant gauge temperature reductions (120 K), which can lead to potential gauge durability improvement, were obtained when the gauges were air-cooled by forced convection.

Liebert, Curt H.↗

Numerical Filtering of Spurious Transients in a Satellite Scanning Radiometer: Application to CERES

The Clouds and Earth Radiant Energy System (CERES) scanning, radiometer was designed to provide high accuracy measurements of the radiances from the earth. Calibration testing of the instruments showed the presence of all undesired slow transient in the measurements of all channels at 1% to 2% of the signal. Analysis of the data showed that the transient consists of a single linear mode. The characteristic time of this mode is 0.3 to 0.4 s and is much greater than that the 8-10-ms response time of the detector, so that it is well separated from the detector response. A numerical filter was designed for the removal of this transient from the measurements. Results show no trace remaining of the transient after application of the numerical filter. The characterization of the slow mode on the basis of ground calibration data is discussed and flight results are shown for the CERES instruments aboard the Tropical Rainfall Measurement Mission and Terra spacecraft. The primary influence of the slow mode is in the calibration of the instrument and the in-flight validation of the calibration. This method may be applicable to other radiometers that are striving for high accuracy and encounter a slow spurious mode regardless of the underlying physics.

Smith, G. Louis↗

SEU and Test Considerations for FPGA Devices

This viewgraph presentation provides an overview of Field Programmable Gate Arrays (FPGAs), what they are, implementations in space missions, and current available technologies. Single Event Upsets (SEUs) and Single Event Transients (SETs) are discussed in relation to their effects on FPGAs. Testing goals, considerations, and data analysis are reviewed.

Berg, Malanie↗

Experimental Validation of a Closed Brayton Cycle System Transient Simulation

The Brayton Power Conversion Unit (BPCU) is a closed cycle system with an inert gas working fluid. It is located in Vacuum Facility 6 at NASA Glenn Research Center. Was used in previous solar dynamic technology efforts (SDGTD). Modified to its present configuration by replacing the solar receiver with an electrical resistance heater. The first closed-Brayton-cycle to be coupled with an ion propulsion system. Used to examine mechanical dynamic characteristics and responses. The focus of this work was the validation of a computer model of the BPCU. Model was built using the Closed Cycle System Simulation (CCSS) design and analysis tool. Test conditions were then duplicated in CCSS. Various steady-state points. Transients involving changes in shaft rotational speed and heat input. Testing to date has shown that the BPCU is able to generate meaningful, repeatable data that can be used for computer model validation. Results generated by CCSS demonstrated that the model sufficiently reproduced the thermal transients exhibited by the BPCU system. CCSS was also used to match BPCU steady-state operating points. Cycle temperatures were within 4.1% of the data (most were within 1%). Cycle pressures were all within 3.2%. Error in alternator power (as much as 13.5%) was attributed to uncertainties in the compressor and turbine maps and alternator and bearing loss models. The acquired understanding of the BPCU behavior gives useful insight for improvements to be made to the CCSS model as well as ideas for future testing and possible system modifications.

Johnson, Paul K.↗

Evaluation of ceramics for stator applications: Gas turbine engines interim report. Stator fabrication and evaluation

The objective was to assess current ceramic materials, fabrication processes, reliability prediction, and stator durability when subjected to simulated automotive gas turbine engine operating conditions. Ceramic one-piece stators were fabricated of two materials, silicon nitride and silicon carbide, using two near-net-shape processes, slip casting and injection molding. Non-destructive evaluation tests were conducted on all stators identifying irregularities which could contribute to failures under durability testing. Development of the test rig and automatic control system for repeatably controlling air flow rate and temperature over a highly transient durability duty cycle is discussed. Durability results are presented for repeated thermal cycle testing of the ceramic one-piece stators. Two duty cycles were used, encompassing the temperature ranges of 704 to 1204 C (1300 to 2200 F) and 871 to 1371 C (1600 to 2500 F). Tests were conducted on 28 stators, accumulating 135,551 cycles in 2441 hours of hot testing. Cyclic durability for the ceramic one-piece stator was demonstrated to be in excess of 500 hours, accumulating over 28,850 thermal cycles. Ceramic interface forces were found to be the significant factor in limiting stator life rather than the scatter in material strength properties or the variation in component defects encountered.

Arnon, N.↗

Testing of a Neon Loop Heat Pipe for Large Area Cryocooling

Cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks is required for future NASA missions. A cryogenic loop heat pipe (CLHP) can provide a closed-loop cooling system for this purpose and has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A neon CLHP was tested extensively in a thermal vacuum chamber using a cryopump as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components. Tests conducted included loop cool-down from the ambient temperature, startup, power cycle, heat removal capability, loop capillary limit and recovery from a dry-out, low power operation, and long duration steady state operation. The neon CLHP demonstrated robust operation. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by applying power to both the pump and evaporator without any pre-conditioning. It could adapt to changes in the pump power andor evaporator power, and reach a new steady state very quickly. The evaporator could remove heat loads between 0.25W and 4W. When the pump capillary limit was exceeded, the loop could resume its normal function by reducing the pump power. Steady state operations were demonstrated for up to 6 hours. The ability of the neon loop to cool large areas was therefore successfully verified.

Cryogenics↗