Search NASA⌕ Search

SEARCH · Search NASA

Results for “VOLTAGE AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Pulse-height analyzer with digital readout

Feedback-controlled pulse-amplitude integrator and amplifier is used as an analog-to-digital converter that converts event-liberated charges, emanating from a nuclear-particle detector, directly to numbers rather than to analog-dependent voltages.

Goldsworthy, W. W.↗

Design, production, and testing of field effect transistors

Cryogenic MOSFETS (CRYOFETS), specifically designed for low temperature preamplifier application with infrared extrinsic detectors were produced and comparatively tested with p-channel MOSFETs under matched conditions. The CRYOFETs exhibit lower voltage thresholds, high source-follower gains at lower bias voltage, and lower dc offset source voltage. The noise of the CRYOFET is found to be 2 to 4 times greater than the MOSFET with a correspondingly lower figure of merit (which is established for source-follower amplifiers). The device power dissipation at a gain of 0.98 is some two orders of magnitude lower than for the MOSFET. Further, CRYOFETs are free of low temperature I vs V character hysteresis and balky conduction turn-on effects and operate effectively in the 2.4 to 20 K range. These devices have promise for use on long term duration sensor missions and for on-focal-plane signal processing at low temperatures.

Sclar, N.↗

Stimulated Generation of Magnetrons powered below the Self-Excitation Threshold Voltage

Modern CW or pulsed superconducting accelerators of megawatts beams require efficient RF sources controllable in phase and power. It is desirable to have an individual RF power source with power up to hundreds of kW for each Superconductive RF (SRF) cavity. For pulsed accelerators the pulse duration in millisecond range is required. The efficiency of the traditional RF sources (klystrons, IOTs, solid-state amplifiers) in comparison to magnetrons is lower and the cost of unit of RF power is significantly higher. Typically, the cost of RF sources and their operation is a significant part of the total project cost and operation. The magnetron-based RF sources with a cost of power unit of 1-3 dollars per Watt would significantly reduce the capital and operation costs in comparison with the traditional RF sources. This arouses interest in magnetron RF sources for use in modern accelerators. A recently developed kinetic model describing the principle of magnetron operation and subsequent experiments resulted in an innovative technique producing the "stimulated" generation of magnetrons powered below the self-excitation threshold voltage. The magnetron operation in this regime is stable, low noise, controllable in phase and power, and provides higher efficiency than other types of RF power sources. It allows operation in CW and pulse modes (at large duty factor). For pulsed operation this technique does not require pulse modulators to form RF pulses. It also looks as a promising opportunity to extend magnetron life time. The developed technique, its experimental verification and a brief explanation of the kinetic model substantiating the technique are presented and discussed in this article.

43 PARTICLE ACCELERATORS↗

A bi-level advanced control framework for large-scale control of buildings with system-level impact

Increased electricity consumption combined with new forms of generation is testing the reliability of our grid infrastructure. This work describes a method to improve the reliability of the grid through large-scale advanced building control. This paper develops a bi-level distributed control framework to shift the load of 153 buildings to achieve a system-level objective of tracking a power reference signal. This bi-level control is based on the previously-developed ANPV-MPC, a predictive controller that uses a Bayesian neural network to generate an accurate control model and adapt to changing conditions over time. By shifting the building electricity demand to better match the available power, the grid system supplying the buildings is more reliable as evidenced by the analysis of node voltages across an IEEE 13-bus distribution system. The proposed bi-level control framework tracks the system-level power reference with enough accuracy to regulate node voltages across the IEEE 13-bus distribution system within ANSI limits of ±5%. Additionally, the adaptive nature of ANPV-MPC allows each building across the system to adapt to changing conditions, further amplifying the system-level reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probing polarization-tunable sub-terahertz spin pumping in bimodal α-Fe 2 O 3 /Pt

Hematite (α-Fe 2 O 3 ) is an insulating antiferromagnet possessing a room temperature canted phase induced by the super-exchange Dzyaloshinskii-Moriya Interaction (DMI), resulting in enhanced spin pumping and spin transport over uniaxial antiferromagnets. In this work we resonantly excite the quasi-ferromagnetic (acoustic) and purely antiferromagnetic (optical) spin-dynamical modes in bulk and thin-film heterostructures of α-Fe 2 O 3 /Pt at room temperature, inducing inverse-spin-Hall-voltages up to 255 GHz. Following recent measurements of optical-mode spin-pumping in α-Fe 2 O 3 , we observe a novel and exotic microwave polarization mapping along with amplified spin-charge conversion in the optical branch and discuss the implications of layer thickness on acoustic and optical spin-modes. The results provide a deeper understanding of spin-wave selection rules for canted antiferromagnets and their potential use in nanoscale terahertz spintronics.

interfaces↗

NASA Tech Briefs, September 2008

Topics covered include: Nanotip Carpets as Antireflection Surfaces; Nano-Engineered Catalysts for Direct Methanol Fuel Cells; Capillography of Mats of Nanofibers; Directed Growth of Carbon Nanotubes Across Gaps; High-Voltage, Asymmetric-Waveform Generator; Magic-T Junction Using Microstrip/Slotline Transitions; On-Wafer Measurement of a Silicon-Based CMOS VCO at 324 GHz; Group-III Nitride Field Emitters; HEMT Amplifiers and Equipment for their On-Wafer Testing; Thermal Spray Formation of Polymer Coatings; Improved Gas Filling and Sealing of an HC-PCF; Making More-Complex Molecules Using Superthermal Atom/Molecule Collisions; Nematic Cells for Digital Light Deflection; Improved Silica Aerogel Composite Materials; Microgravity, Mesh-Crawling Legged Robots; Advanced Active-Magnetic-Bearing Thrust- Measurement System; Thermally Actuated Hydraulic Pumps; A New, Highly Improved Two-Cycle Engine; Flexible Structural-Health-Monitoring Sheets; Alignment Pins for Assembling and Disassembling Structures; Purifying Nucleic Acids from Samples of Extremely Low Biomass; Adjustable-Viewing-Angle Endoscopic Tool for Skull Base and Brain Surgery; UV-Resistant Non-Spore-Forming Bacteria From Spacecraft-Assembly Facilities; Hard-X-Ray/Soft-Gamma-Ray Imaging Sensor Assembly for Astronomy; Simplified Modeling of Oxidation of Hydrocarbons; Near-Field Spectroscopy with Nanoparticles Deposited by AFM; Light Collimator and Monitor for a Spectroradiometer; Hyperspectral Fluorescence and Reflectance Imaging Instrument; Improving the Optical Quality Factor of the WGM Resonator; Ultra-Stable Beacon Source for Laboratory Testing of Optical Tracking; Transmissive Diffractive Optical Element Solar Concentrators; Delaying Trains of Short Light Pulses in WGM Resonators; Toward Better Modeling of Supercritical Turbulent Mixing; JPEG 2000 Encoding with Perceptual Distortion Control; Intelligent Integrated Health Management for a System of Systems; Delay Banking for Managing Air Traffic; and Spline-Based Smoothing of Airfoil Curvatures.

Source record↗

PN lock indicator for dithered PN code tracking loop

In a delay-lock one-delta (+or - 1/2 chip) dithered PN code tracking loop, an indication of lock in the PN code tracking loop is provided by delaying the dithered local PN code by a half chip to produce a +0, -1 dithered PN code that is then multiplied with the received PN-spread IF signal to produce a signal proportional to the correlation of this dithered code offset from the received code. The correlation signal is bandpass filtered, amplified with AGC control, and square-law detected to obtain a dc signal proportional to the degree of correlation. The dc signal is multiplied by the dithering control signal to effectivity substract noise voltage from the lock correlation signal which is then compared with a PN lock status signal.

Carson, L. M.↗

Tuned analog network

A noninverting, direct current amplifier stage is cascaded into an integrator stage to form a two stage tuned network with a single input junction common to both stages. The network provides independent adjustment of center frequency, bandwidth and voltage gain. The insertion of a positive feedback loop between the stages provides a very narrow bandwidth network. The addition of back to back zener diodes between the common input node and ground converts the network into an oscillator.

Kleinberg, L. L.↗

Micromachined TWTs for THz Radiation Sources

The Terahertz (THz) region of the electromagnetic spectrum (about 300 - 3000 GHz in frequency or about 0.1 - 1 mm free space wavelength) has enormous potential for high-data-rate communications, spectroscopy, astronomy, space research, medicine, biology, surveillance, remote sensing, industrial process control, etc. It has been characterized as the most scientifically rich, yet under-utilized, region of the electromagnetic spectrum. The most critical roadblock to full exploitation of the THz band is lack of coherent radiation sources that are powerful (0.001 - 1.0 W continuous wave), efficient (> 1%), frequency agile (instantaneously tunable over 1% bandwidths or more), reliable, and comparatively inexpensive. To develop vacuum electron device (VED) radiation sources satisfying these requirements, fabrication and packaging approaches must be heavily considered to minimize costs, in addition to the basic interaction physics and circuit design. To minimize size of the prime power supply, beam voltage must be minimized, preferably 10 kV. Solid state sources satisfy the low voltage requirement, but are many orders of magnitude below power, efficiency, and bandwidth requirements. On the other hand, typical fast-wave VED sources in this regime (e.g., gyrotrons, FELs) tend to be large, expensive, high voltage and very high power devices unsuitable for most of the applications cited above. VEDs based on grating or inter-digital (ID) circuits have been researched and developed. However, achieving forward-wave amplifier operation with instantaneous fractional bandwidths > 1% is problematic for these devices with low-energy (< 15 kV) electron beams. Moreover, the interaction impedance is quite low unless the beam-circuit spacing is kept particularly narrow, often leading to significant beam interception. One solution to satisfy the THz source requirements mentioned above is to develop micromachined VEDs, or "micro-VEDs". Among other benefits, micro-machining technologies provide superior high frequency wall conductivity as a result of superior surface smoothness compared with conventional mechanical or electric discharge machining approaches. Micro-VED technologies are already being applied to the development of millimeter-wave klystrons at Stanford Linear Accelerator Center and submillimeter-wave klystrons at the University of Leeds. We are investigating the use of micro-machining technologies to develop THz regime TWTs, with emphasis on folded-waveguide TWTs. The folded-waveguide TWT (FW-TWT) has several features that make it attractive for THz-regime micro-VED applications. It is a relatively simple circuit to design and fabricate, it is amenable to precision pattern replication by micro-machining, and it is has been demonstrated capable of forward-wave amplification with appreciable bandwidth. We are conducting experimental and computational studies of micro-VED FW-TWTs to examine their feasibility for applications at frequencies from 200 - 1000 GHz.

Booske, John H.↗

Fuzzy Control Hardware for Segmented Mirror Phasing Algorithm

This paper presents a possible implementation of a control model developed to phase a system of segmented mirrors, with a PAMELA configuration, using analog fuzzy hardware. Presently, the model is designed for piston control only, but with the foresight that the parameters of tip and tilt will be integrated eventually. The proposed controller uses analog circuits to exhibit a voltage-mode singleton fuzzifier, a mixed-mode inference engine, and a current-mode defuzzifier. The inference engine exhibits multiplication circuits that perform the algebraic product composition through the use of operational transconductance amplifiers rather than the typical min-max circuits. Additionally, the knowledge base, containing exemplar data gained a priori through simulation, interacts via a digital interface.

Roth, Elizabeth↗

Automated Cryocooler Monitor and Control System Software

This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.

Britchcliffe, Michael J.↗

Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies

In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field.

Gottardi, L.↗

Ion beams extraction and measurements of plasma parameters on a multi-frequencies microwaves large bore ECRIS with permanent magnets

We have developed an all-permanent magnet large bore electron cyclotron resonance ion source (ECRIS) for broad ion beam processing. The cylindrically comb-shaped magnetic field configuration is adopted for efficient plasma production and good magnetic confinement. To compensate for disadvantages of fixed magnetic configuration, a traveling wave tube amplifier (TWTA) is used. In the comb-shaped ECRIS, it is difficult to achieve controlling ion beam profiles in the whole inside the chamber by using even single frequency-controllable TWTA (11-13GHz), because of large bore size with all-magnets. We have tried controlling profiles of plasma parameters and then those of extracted ion beams by launching two largely different frequencies simultaneously, i.e., multi-frequencies microwaves. Here we report ion beam profiles and corresponding plasma parameters under various experimental conditions, dependence of ion beams against extraction voltages, and influence of different electrode positions on the electron density profile.

43 PARTICLE ACCELERATORS↗

High power metallic halide laser

A laser amplification system is disclosed whereby a metallic halide vapor such as copper chloride is caused to flow through a laser amplifier and a heat exchanger in a closed loop system so that the flow rate is altered to control the temperature rise across the length of the laser amplifier. The copper atoms within the laser amplifier should not exceed a temperature of 3000 K, so that the number of copper atoms in the metastable state will not be high enough to prevent amplification in the amplifier. A molecular dissociation apparatus is provided at the input to the laser amplifier for dissociating the copper chloride into copper atoms and ions and chlorine atoms and ions. The dissociation apparatus includes a hollow cathode tube and an annular ring spaced apart from the tube end. A voltage differential is applied between the annular ring and the hollow cathode tube so that as the copper chloride flows through, it is dissociated into copper and chlorine ions and atoms.

Pivirotto, T. J.↗

Compact carbon monoxide sensor utilizing a confocal optical cavity.

The carbon monoxide sensor discussed in this paper utilizes a unique confocal cavity which allows the complete system to be packaged in a small volume suitable for hand-held use. The optical system is the heart of the instrument with equal emphasis placed on the electronics support circuitry, consisting essentially of a thermal infrared pyroelectric detector and lock-in amplifier. The pyroelectric detector offers a major advantage over other thermal detectors, providing a signal-to-noise ratio and detectivity that remain nearly constant over the frequency range from dc to 2000 Hz. Since bias voltage is not required, low frequency noise is not generated in the detector.

Scott, B.↗

Supply-noise-rejecting current source

Various technologies pertaining to a high-impedance current source are described herein. The current source outputs a substantially constant current by way of a first transistor that draws current from a supply. The current source is configured to feed back noise from the supply to a feedback resistor at an input of an operational amplifier (op-amp) by way of a second transistor. The feedback resistor and the op-amp are configured such that responsive to receiving the supply noise feedback, the op-amp drives a gate voltage of the first transistor to cause the first transistor to reject the supply noise and cause the output of the current source to remain substantially constant.

Wessendorf, Kurt O.↗

Supply-noise-rejecting current source

Various technologies pertaining to a high-impedance current source are described herein. The current source outputs a substantially constant current by way of a first transistor that draws current from a supply. The current source is configured to feed-back noise from the supply to a feedback resistor at an input of an operational amplifier (op-amp) by way of a second transistor. The feedback resistor and the op-amp are configured such that responsive to receiving the supply noise feedback, the op-amp drives a gate voltage of the first transistor to cause the first transistor to reject the supply noise and cause the output of the current source to remain substantially constant.

42 ENGINEERING↗

Experimental Determination of the Multiplicity Deadtime Parameter

Definition, extraction, and application of dead-time parameters, in correlated neutron counting, are long standing, thorny issues. Traditionally, dead-time corrections have been estimated on the assumption of a simple paralyzing model, arising from the action of the discriminator in the charged amplifiers connected to the {sup 3}He proportional counters, using a fixed dead-time. Various schemes exist to apply the paralysable model to the multiplicity shift register histogram data. In principle, several methods could be used to estimate the dead-time parameter. The approach which is most widely applied involves measuring a series of Cf-252 sources spanning a wide dynamic range of counting rates. Ratios between the Singles, Doubles and Triples rates which ought to be independent of fissile mass are extracted. The dead-time is chosen so as to achieve the best independence in the ratios, characteristic of the fissioning system, over the counting range. These measurements can be quite laborious to conduct; require a set of Cf-252 sources matched in construction and isotopic composition; require long counts to achieve the requisite precision and involve a good deal of numerical analysis to interpret. In this work we present a simpler scheme which produces comparable values in a way that is easier to implement. In essence we place a near random neutron source, such as may be realized using Am/Li {alpha}-n sources, in the cavity and record the multiplicity histograms as one would for an assay. The variance to mean-squared is narrower than for a random counting experiment, however, as a result of the dead-time losses. A simple formula exists allowing the deadtime to be extracted from this measurement. In this paper, we present results for the traditional approach, the proposed approach and also a variation based on adjusting the total event rate by adding Am/Li sources to a single Cf-252 source fixed in position for the case of a pair of Passive Scrap Multiplicity Counters (PSMC's). Excellent agreement is obtained. Because the variance to mean squared approach gives high precision in a single, short, measurement it lends itself to studying dead-time behaviors systematically as a function of shift register settings, operating voltage and preamplifier trim. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗