Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Electron Bunch Profile Reconstruction in the Few fs Regime using Coherent Smith-Purcell Radiation

Advanced accelerators for fourth generation light sources based on high brightness linacs or laser-driven wakefield accelerators will operate with intense, highly relativistic electron bunches that are only a few fs long. Diagnostic techniques for the determination of temporal profile of such bunches are required to be non invasive, single shot, economic and with the required resolution in the fs regime. The use of a radiative process such as coherent Smith-Purcell radiation (SPR), is particularly promising with this respect. In this technique the beam is made to radiate a small amount of electromagnetic radiation and the temporal profile is reconstructed from the measured spectral distribution of the radiation. We summarise the advantages of SPR and present the design parameters and preliminary results of the experiments at the FACET facility at SLAC. We also discuss a new approach to the problem of the recovery of the 'missing phase', which is essential for the accurate reconstruction of the temporal bunch profile.

43 PARTICLE ACCELERATORS↗

The CEBAF Master Oscillator and Distribution Remodeling

Jefferson Lab's CEBAF accelerator operation requires various frequency references to be distributed along the site. Three signals: 10 MHz, 70 MHz and 499 MHz are synthesized in the Machine Control Center (MCC) while 1427 MHz and 429 MHz are derived from 499 MHz and 70 MHz signals in four separate locations. We are replacing our obsolete 10 MHz, 70 MHz and 499 MHz sources with new sources that will incorporate a GPS receiver to discipline a 10 MHz reference. In addition the MO (Master Oscillator) system will be redundant (duplicate MO) and a third signal source will be used as a system diagnostic. Moreover, the 12 GeV Energy Upgrade for CEBAF accelerator will be adding 80 new RF systems. To support them the distribution of 1427 MHz and 70 MHz signals has to be extended and be able to deliver enough LO (Local Oscillator) and IF (Intermediate Frequency) power to 320 old and 80 new 80 RF systems. This paper discusses the new MO and the drive line extension.

43 PARTICLE ACCELERATORS↗

Diagnostics of the ITER neutral beam test facility

The ITER heating neutral beam (HNB) injector, based on negative ions accelerated at 1 MV, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on the ITER HNB. The RF source, where the H{sup -}/D{sup -} production is enhanced by cesium evaporation, will be monitored with thermocouples, electrostatic probes, optical emission spectroscopy, cavity ring down, and laser absorption spectroscopy. The beam is analyzed by cooling water calorimetry, a short pulse instrumented calorimeter, beam emission spectroscopy, visible tomography, and neutron imaging. Design of the diagnostic systems is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prediction of electric and magnetic fields from spectral data using machine learning algorithms for Doppler-free saturation spectroscopy diagnostics

The prediction of electric and magnetic field amplitudes from atomic spectral data is critical for plasma control in fusion devices such as tokamaks. Conventional approaches that rely on physics-based models are computationally expensive and unsuitable for real-time applications. In this work, we develop and benchmark three machine learning algorithms—simulation-based inference (SBI), fully connected neural networks (FCNN), and histogram-based gradient boosting regression (GBR-Hist)—to infer field intensities directly from Doppler-free saturation spectroscopy (DFSS) spectra. Synthetic datasets of spectra were generated using the EZSSS code and evaluated both with and without added Poisson noise to mimic experimental conditions. We find that SBI achieves the highest accuracy and robustness, FCNN provides a strong balance of accuracy and computational efficiency for real-time applications, and GBR-Hist offers the fastest inference but is more sensitive to noise. Furthermore, these results demonstrate the potential of machine learning to accelerate DFSS analysis and enhance its utility for plasma diagnostics and control.

Doppler-free saturation spectroscopy↗

BEAM SIMULATIONS USING VIRTUAL DIAGNOSTICS FOR THE DRIVER LINAC

End-to-end beam simulations for the driver linac have shown that the design meets the necessary performance requirements including having adequate transverse and longitudinal acceptances. However, to achieve reliable operational performance, the development of appropriate beam diagnostic systems and control room procedures are crucial. With limited R&D funding, beam simulations provide a cost effective tool to evaluate candidate beam diagnostic systems and to provide a critical basis for developing early commissioning and later operational activities. We propose to perform beam dynamic studies and engineering analyses to define the requisite diagnostic systems of the driver linac and through simulation to develop and test commissioning and operational procedures.

43 PARTICLE ACCELERATORS↗

Power Flow Spectroscopy Diagnostics & Platform Development at the Z Pulsed Power Facility

Large pulsed power accelerators deliver multi-MJ pulses of electrical energy to a variety of high energy density (HED) physics experiments that support stockpile science programs. Understanding the plasma formation mechanisms and resulting electrical power transport (or "power flow") in the vacuum magnetically insulated transmission lines (MITLs) is an important area of ongoing research, and could provide a means to improve the performance of today's pulsed power accelerators while improving confidence in the design options for next-generation pulsed power concepts. Power flow science has been studied for decades, but these studies have not provided a predictive understanding of plasma formation and expansion in MITL systems. Several recent factors in pulsed power system design have generated a renewed (and urgent) interest in developing validated, multi-physics power flow engineering models with increased scrutiny and understanding. Examples of these factors include (i) the use of high inductance experimental configurations that could increase current "loss", (ii) interest in long-pulse applications that require predictable pulse shapes, and (iii) the desire to develop a deeper understanding of how current loss phenomena scale to larger accelerator configurations. This work is directed to support the validation of multi-physics power flow engineering models required to realize pulsed power systems for the NNSA mission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel method to recover DD fusion proton CR-39 data corrupted by fast ablator ions at OMEGA and the National Ignition Facility

CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Wire Position Monitor System for the 1.3 FHZ Tesla-Style Cryomodule at the Fermilab New-Muon-Lab Accelerator

The first cryomodule for the beam test facility at the Fermilab New-Muon-Lab building is currently under RF commissioning. Among other diagnostics systems, the transverse position of the helium gas return pipe with the connected 1.3 GHz SRF accelerating cavities is measured along the {approx}15 m long module using a stretched-wire position monitoring system. An overview of the wire position monitor system technology is given, along with preliminary results taken at the initial module cooldown, and during further testing. As the measurement system offers a high resolution, we also discuss options for use as a vibration detector. An electron beam test facility, based on superconducting RF (SRF) TESLA-style cryomodules is currently under construction at the Fermilab New-Muon-Lab (NML) building. The first, so-called type III+, cryomodule (CM-1), equipped with eight 1.3 GHz nine-cell accelerating cavities was recently cooled down to 2 K, and is currently under RF conditioning. The transverse alignment of the cavity string within the cryomodule is crucial for minimizing transverse kick and beam break-up effects, generated by the high-order dipole modes of misaligned accelerating structures. An optimum alignment can only be guaranteed during the assembly of the cavity string, i.e. at room temperatures. The final position of the cavities after cooldown is uncontrollable, and therefore unknown. A wire position monitoring system (WPM) can help to understand the transverse motion of the cavities during cooldown, their final location and the long term position stability after cryo-temperatures are settled, as well as the position reproducibility for several cold-warm cycles. It also may serve as vibration sensor, as the wire acts as a high-Q resonant detector for mechanical vibrations in the low-audio frequency range. The WPM system consists out of a stretched-wire position detection system, provided with help of INFN-Milano and DESY Hamburg, and RF generation and read-out electronics, developed at Fermilab.

43 PARTICLE ACCELERATORS↗

The Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS)

EUNIS (Extreme Ultraviolet Normal Incidence Spectrograph) is a high-efficiency extreme ultraviolet spectrometer that is expected to fly for the first time in 2004 as a sounding rocket payload. Using two independent optical systems, EUNIS will probe the structure and dynamics of the inner solar corona high spectral resolution in two wavelength regions: 17-21 nm with 3.5 pm resolution and 30-37 nm with 7 pm resolution. The long wavelength channel includes He II 30.4 nm and strong lines from Fe XI-XVI; the short wavelength channel includes strong lines of Fe IX-XIII. Angular resolution of 2 arcsec is maintained along a slit covering a full solar radius. EUNIS will have 100 times the throughput of the highly successful SERTS payloads that have preceded it. There are only two reflections in each optical channel, from the superpolished, off-axis paraboloidal primary and the toroidal grating. Each optical element is coated with a high-efficiency multilayer coating optimized for its spectral bandpass. The detector in each channel is a microchannel plate image intensifier fiber- coupled to three 1K x 1K active pixel sensors. EUNIS will obtain spectra with a cadence as short as 1 sec, allowing unprecedented studies of the physical properties of evolving and transient structures. Diagnostics of wave heating and reconnection wil be studied at heights above 2 solar radii, in the wind acceleration region. The broad spectral coverage and high spectral resolution will provide superior temperature and density diagnostics and will enable underflight calibration of several orbital instruments, including SOHO/CDS and EIT, TRACE, Solar-B/EIS, and STEREO/EUVI. EUNIS is supported by NASA through the Low Cost Access to Space Program in Solar and Heliospheric Physics.

Oegerle, William↗

Laser wire beam profile monitor in the Spallation Neutron Source (SNS) superconducting linac

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is an accelerator based neutron scattering facility. The SNS uses the large scale high energy superconducting linac (SCL) to provide high beam power utilizing hydrogen ion (H-) beams. For the diagnostics of high-brightness H- beam in the SCL, nonintrusive methods have to be developed. This paper describes design, implementation, theoretical analysis and experimental demonstration of a nonintrusive profile monitor system based on photodetachment, also known as laser wire, installed in the SNS-SCL. The SNS laser wire system is the largest of its kind with a capability of measuring both horizontal and vertical profiles of an operational H- beam at each of the 23 cryomodule stations along the SCL beam line by employing a single light source. Presently 9 laser wire stations have been commissioned which measures H- beam profiles at 9 different locations corresponding to energy levels of 200 MeV to 1 GeV. The laser wire diagnostics has no moving parts inside the beam pipe, causes no contamination on the superconducting surface, and can be run parasitically on an operational neutron production H- beam.

43 PARTICLE ACCELERATORS↗

From Spreadsheet to Assembly, Using NX Automation

At Thomas Jefferson National Accelerator Facility (JLab), accelerator physicists design beamlines that will accelerate electrons to energies up to 12 GeV. Beamline designs are created, employing a series of SRF accelerating cavities, bending and focusing electro-magnets, and beam diagnostics. Typically, mechanical and structural constraints are not taken into consideration in the initial designs and this results in many design iterations. A typical beamline will have hundreds to thousands of design components listed in their design orbit. Previously, components needed to be inserted one at a time to populate the beamline assembly. A process was developed at JLab to take accelerator physics data and automate the process to populate an assembly with the thousands of components. A spreadsheet of position and orientation data as well as a component matrix of part names vs. Teamcenter elements are input files for customized a NX journaling program, which is used to place the many elements into the resulting assembly. This presentation explains the process, the challenges, and the tools used to develop this process and the resulting project. An examination of the time savings is also presented.

Lassiter, Ronald↗

High-energy resolution Thomson Parabola spectrometer for laser plasma diagnostics

Thomson Parabola (TP) spectrometers are widely used devices for laser-driven beam diagnostics as they provide a complete set of information on the accelerated particles. A novel TP has been developed at LNS with a design able to detect protons up to 20 MeV. The layout design and some results obtained during the experimental campaign at PALS laboratory will be reported in the following.

43 PARTICLE ACCELERATORS↗

Wavefront Measurement for Laser-Guiding Diagnostic

The wavefront of a short laser pulse after interaction in a laser-plasma accelerator (LPA) was measured to diagnose laser-guiding quality. Experiments were performed on a 100 TW class laser at the LOASIS facility of LBNL using a hydrogen-filled capillary discharge waveguide. Laser-guiding with a pre-formed plasma channel allows the laser pulse to propagate over many Rayleigh lengths at high intensity and is crucial to accelerate electrons to the highest possible energy. Efficient coupling of laser energy into the plasma is realized when the laser and the channel satisfy a matched guiding condition, in which the wavefront remains flat within the channel. Using a wavefront sensor, the laser-guiding quality was diagnosed based on the wavefront of the laser pulse exiting the plasma channel. This wavefront diagnostic will contribute to achieving controlled, matched guiding in future experiments.

43 PARTICLE ACCELERATORS↗

Wavefront Measurement for Laser-Guiding Diagnostic

The wavefront of a short laser pulse after interaction in a laser-plasma accelerator (LPA) was measured to diagnose laser-guiding quality. Experiments were performed on a 100 TW class laser at the LOASIS facility of LBNL using a hydrogenfilled capillary discharge waveguide. Laser-guiding with a pre-formed plasma channel allows the laser pulse to propagate over many Rayleigh lengths at high intensity and is crucial to accelerate electrons to the highest possible energy. Efficient coupling of laser energy into the plasma is realized when the laser and the channel satisfy a matched guiding condition, in which the wavefront remains flat within the channel. Using a wavefront sensor, the laser-guiding quality was diagnosed based on the wavefront of the laser pulse exiting the plasma channel. This wavefront diagnostic will contribute to achieving controlled, matched guiding in future experiments.

43 PARTICLE ACCELERATORS↗

Beam Imaging Diagnostic (BID) chamber blackening status March 2018

The Neutron Imaging project is using a high average power accelerator to produce a unique high flux source of neutrons. The neutron beam quality requires a small spot of deuterons on a target, which makes beam quality measurements critical to overall machine performance. Beam measurements are challenging with high average power particle beams, because the most common techniques are intercepting and the diagnostic will not survive the interaction.

43 PARTICLE ACCELERATORS↗

Simulations of future particle accelerators: issues and mitigations

The ever increasing demands placed upon machine performance have resulted in the need for more comprehensive particle accelerator modeling. Computer simulations are key to the success of particle accelerators. Many aspects of particle accelerators rely on computer modeling at some point, sometimes requiring complex simulation tools and massively parallel supercomputing. Examples include the modeling of beams at extreme intensities and densities (toward the quantum degeneracy limit), and with ultra-fine control (down to the level of individual particles). In the future, adaptively tuned models might also be relied upon to provide beam measurements beyond the resolution of existing diagnostics. Much time and effort has been put into creating accelerator software tools, some of which are highly successful. However, there are also shortcomings such as the general inability of existing software to be easily modified to meet changing simulation needs. In this paper possible mitigating strategies are discussed for issues faced by the accelerator community as it endeavors to produce better and more comprehensive modeling tools. This includes lack of coordination between code developers, lack of standards to make codes portable and/or reusable, lack of documentation, among others.

43 PARTICLE ACCELERATORS↗

A Comprehensive Chemistry Evaluation and Diagnostics Package for E3SM – ChemDyg Version 1.1.0

The Chemistry Evaluation and Diagnostics Package (ChemDyg) is an open-source tool designed for the Energy Exascale Earth System Model (E3SM) developed by the U.S. Department of Energy. ChemDyg facilitates routine evaluation, tailored development, and in-depth analysis of atmospheric chemistry through its modular architecture, allowing users to compare model outputs with observational data. Version 1.1.0 introduces a robust set of diagnostic capabilities, including climatology, time evolution of key tracers, diurnal and annual cycle analyses, and extensive budget diagnostics. These features help identify model discrepancies and enhance the representation of atmospheric chemistry in E3SM. Each self-contained diagnostic set includes dedicated scripts and documentation for ease of use. The interactive HTML output improves data accessibility, accelerating chemistry model development. Additionally, ChemDyg's flexible framework allows for customization, enabling users to create unique diagnostic sets for specific scientific contributions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗