Search NASA⌕ Search

SEARCH · Search NASA

Results for “accurate quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Field deployable trace radioisotope analysis through combined electrochemical and alpha spectroscopy methods

A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Statistical modelling and Bayesian inversion for a Compton imaging system: application to radioactive source localization

Abstract This paper presents a statistical forward model for a Compton imaging system, called Compton imager. This system, under development at the University of Illinois Urbana Champaign, is a variant of Compton cameras with a single type of sensors which can simultaneously act as scatterers and absorbers. This imager is convenient for imaging situations requiring a wide field of view. The proposed statistical forward model is then used to solve the inverse problem of estimating the location and energy of point-like sources from observed data. This inverse problem is formulated and solved in a Bayesian framework by using a Metropolis within Gibbs algorithm for the estimation of the location, and an expectation-maximization algorithm for the estimation of the energy. This approach leads to more accurate estimation when compared with the deterministic standard back-projection approach, with the additional benefit of uncertainty quantification in the low photon imaging setting.

Tarpau, Cécilia (ORCID:0000000286539490)↗

Evaluation of a method for activity estimation in Sm-153 EDTMP imaging

Absolute activity evaluation is fundamental for internal radionuclide dosimetry when patient-specific therapy optimization is wanted. Often, quantification is attempted with 3D SPECT image based (IB) methods, but the true concentration values can be underestimated due to the partial volume effect (PVE). This is especially true when small diffuse lesions are present. In this paper, we describe a 3D region of interest (ROI) based quantification method (LS-ROI), which estimates the ROI concentration values directly from the projection data acquired in the tomographic scan once ROIs have been segmented on a CT and/or a SPECT image. The method, which has inherent PVE correction capabilities, was applied both on simulated and on real phantom data. Simulations reflected the case of a patient with bone metastases treated with {sup 153}Sm-EDTMP: Both the activity in the metastases and the total retention in the skeleton were evaluated. Thirty noisy data sets were produced in order to evaluate the accuracy and precision of the method. The effect of region segmentation errors on estimated concentrations was thoroughly investigated. Real data were acquired on a NEMA phantom, where a cylindrical central region (283 cm{sup 3}) simulated the bone and two spheres (10.3 and 25.5 cm{sup 3}) simulated the metastases. The results obtained with the LS-ROI method were compared with those of a conventional 3D IB method and those of a quantitative conjugate view approach derived from LS-ROI and applied to the anterior and posterior views acquired in the tomographic scan (LS-ROI anterior-posterior: LS-ROI-AP). Simulations showed that when the geometry of regions is known, the LS-ROI method recovered the simulated concentration values within 20%, while the IB method underestimated the concentration in high activity small lesions by as much as 49%. Segmentation errors, up to 44% of the true region volume, produced a higher variation in LS-ROI estimates than in IB ones; however, the overall bias of the LS-ROI estimates ({<=}25%) remained lower than that of IB estimates. In the case of the evaluation of the total retention in the skeleton, the LS-ROI method recovered the simulated value within 2%, while IB underestimated it up to 13%. In all the cases, the LS-ROI-AP method showed an accuracy comparable with that of the LS-ROI one, and a worse precision just because of the lower number of counts used in the analysis. However, a worsening of LS-ROI-AP performances was demonstrated in the case of strong overlap of regions: In this case, a bias of up to 40% was observed. The results obtained on real phantom data confirmed the simulation results: The IB method underestimated activity up to 47% in the smallest sphere, while the bias was reduced to 13% with LS-ROI and LS-ROI-AP estimates. The good quantification capabilities of the LS-ROI method can be useful for absolute activity quantification in the case of small active diffused lesions and constitute the basis for the development of an accurate patient-specific planning strategy in internal radionuclide treatments, provided there is a reliable segmentation of lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Bayesian Approach for Quantifying Data Scarcity when Modeling Human Behavior via Inverse Reinforcement Learning

Computational models that formalize complex human behaviors enable study and understanding of such behaviors. However, collecting behavior data required to estimate the parameters of such models is often tedious and resource intensive. Thus, estimating dataset size as part of data collection planning (also known as Sample Size Determination) is important to reduce the time and effort of behavior data collection while maintaining an accurate estimate of model parameters. In this paper, we present a sample size determination method based on Uncertainty Quantification (UQ) for a specific Inverse Reinforcement Learning (IRL) model of human behavior, in two cases: 1) pre-hoc experiment design—conducted in the planning stage before any data is collected, to guide the estimation of how many samples to collect; and 2) post-hoc dataset analysis—performed after data is collected, to decide if the existing dataset has sufficient samples and whether more data is needed. Here, we validate our approach in experiments with a realistic model of behaviors of people with Multiple Sclerosis (MS) and illustrate how to pick a reasonable sample size target. Our work enables model designers to perform a deeper, principled investigation of effects of dataset size on IRL.

97 MATHEMATICS AND COMPUTING↗

High Accuracy Transistor Compact Model Calibrations

Typically, transistors are modeled by the application of calibrated nominal and range models. These models consists of differing parameter values that describe the location and the upper and lower limits of a distribution of some transistor characteristic such as current capacity. Correspondingly, when using this approach, high degrees of accuracy of the transistor models are not expected since the set of models is a surrogate for a statistical description of the devices. The use of these types of models describes expected performances considering the extremes of process or transistor deviations. In contrast, circuits that have very stringent accuracy requirements require modeling techniques with higher accuracy. Since these accurate models have low error in transistor descriptions, these models can be used to describe part to part variations as well as an accurate description of a single circuit instance. Thus, models that meet these stipulations also enable the calculation of quantification of margins with respect to a functional threshold and uncertainties in these margins. Given this need, new model high accuracy calibration techniques for bipolar junction transistors have been developed and are described in this report.

42 ENGINEERING↗

Improved representation of the global dust cycle using observational constraints on dust properties and abundance

Even though desert dust is the most abundant aerosol by mass in Earth's atmosphere, atmospheric models struggle to accurately represent its spatial and temporal distribution. These model errors are partially caused by fundamental difficulties in simulating dust emission in coarse-resolution models and in accurately representing dust microphysical properties. Here we mitigate these problems by developing a new methodology that yields an improved representation of the global dust cycle. We present an analytical framework that uses inverse modeling to integrate an ensemble of global model simulations with observational constraints on the dust size distribution, extinction efficiency, and regional dust aerosol optical depth. We then compare the inverse model results against independent measurements of dust surface concentration and deposition flux and find that errors are reduced by approximately a factor of 2 relative to current model simulations of the Northern Hemisphere dust cycle. The inverse model results show smaller improvements in the less dusty Southern Hemisphere, most likely because both the model simulations and the observational constraints used in the inverse model are less accurate. On a global basis, we find that the emission flux of dust with a geometric diameter up to 20 µm (PM20) is approximately 5000 Tg yr−1, which is greater than most models account for. This larger PM20 dust flux is needed to match observational constraints showing a large atmospheric loading of coarse dust. We obtain gridded datasets of dust emission, vertically integrated loading, dust aerosol optical depth, (surface) concentration, and wet and dry deposition fluxes that are resolved by season and particle size. As our results indicate that this dataset is more accurate than current model simulations and the MERRA-2 dust reanalysis product, it can be used to improve quantifications of dust impacts on the Earth system.

Dust cycle↗

ADVANCED-STEM-BASED DEEP LEARNING FOR SEMANTIC SEGMENTATION OF DEFECTS IN STEELS

In this work, we developed a novel deep convolutional neural network (DCNN) model, called DefectNet, for robust and automated semantic segmentation of three crystallographic defects including line dislocations, precipitates and voids commonly observed in structural metals and alloys. In previous work, we established an experimental protocol for a diffraction contrast imaging scanning transmission electron microscopy (DCI STEM) technique and tailored it specifically for imaging defects in popular iron-based structural alloy. Thus, the DefectNet was trained over a small but high-quality DCI STEM defect image sets of a HT-9 martensitic steel before and after neutron irradiation for 111.8 dpa at 412°C. For the defect quantification that typically takes at least half an hour even for an expert, with a good model the machine learning algorithm can produce more reproducible and reliable quantification in a few seconds. This work demonstrates the feasibility of using deep learning algorithms for fast and accurate defect quantitative analysis.

Machine Learning, Radiation effects, Image analysi↗

Quantification of processing artifacts in textile composites

One of the greatest difficulties in developing detailed models of the mechanical response of textile reinforced composites is an accurate model of the reinforcing elements. In the case of elastic property prediction, the variation of fiber position may not have a critical role in performance. However, when considering highly localized stress events, such as those associated with cracks and holes, the exact position of the reinforcement probably dominates the failure mode. Models were developed for idealized reinforcements which provide an insight into the local behavior. However, even casual observations of micrographical images reveals that the actual material deviates strongly from the idealized models. Some of the deviations and causes are presented for triaxially braided and three dimensionally woven textile composites. The necessary modeling steps to accommodate these variations are presented with some examples. Some of the ramifications of not accounting for these discrepencies are also addressed.

Pastore, Christopher M.↗

Noninvasive Assessment of Right Ventricular Function in Patients with Pulmonary Arterial Hypertension and Left Ventricular Assist Device

Purpose of Review: Right ventricular (RV) failure in patients with pulmonary arterial hypertension (PAH) and left ventricular assist device (LVAD) is associated with increased hospitalizations, worsening functional class, and poor survival. Accurate RV function assessment is essential in diagnosing RV failure, guiding therapies, and determining prognosis. Noninvasive imaging techniques provide fast and reliable quantification of RV morphology and function. Recent Findings: We review echocardiography, nuclear medicine, and cardiac magnetic resonance imaging (MRI) uses for RV function assessment in patients with PAH and LVAD. We identify current knowledge gaps in utilizing noninvasive tests to assess RV function. Summary: Echocardiography is most widely used to quantify RV function in patients with PAH and LVAD, followed by cardiac MRI for RV morphology and function measurement in PAH patients. The first-pass radionuclide angiography with radiolabeled RBC is the gold standard for calculating RV function. Gated blood pool SPECT can be an alternative as it separates the cardiac chambers well and provides accurate assessment of the RV function with high reproducibility, which is particularly useful for monitoring treatment. More research is needed to compare and validate these modalities in evaluating RV function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uncertainty bounds for multivariate machine learning predictions on high-strain brittle fracture

Simulation of the crack network evolution on high strain rate impact experiments performed in brittle materials is very compute-intensive. The cost increases even more if multiple simulations are needed to account for the randomness in crack length, location, and orientation, which is inherently found in real-world materials. Constructing a machine learning emulator can make the process faster by orders of magnitude. There has been little work, however, on assessing the error associated with their predictions. Estimating these errors is imperative for meaningful overall uncertainty quantification. In this work, we extend the heteroscedastic uncertainty estimates to bound a multiple output machine learning emulator. Overall, we find that the response prediction is accurate within its predicted errors, but with a somewhat conservative estimate of uncertainty.

36 MATERIALS SCIENCE↗

Electronic structure prediction of multi-million atom systems through uncertainty quantification enabled transfer learning

The ground state electron density — obtainable using Kohn-Sham Density Functional Theory (KS-DFT) simulations — contains a wealth of material information, making its prediction via machine learning (ML) models attractive. However, the computational expense of KS-DFT scales cubically with system size which tends to stymie training data generation, making it difficult to develop quantifiably accurate ML models that are applicable across many scales and system configurations. Here, we address this fundamental challenge by employing transfer learning to leverage the multi-scale nature of the training data, while comprehensively sampling system configurations using thermalization. Our ML models are less reliant on heuristics, and being based on Bayesian neural networks, enable uncertainty quantification. We show that our models incur significantly lower data generation costs while allowing confident — and when verifiable, accurate — predictions for a wide variety of bulk systems well beyond training, including systems with defects, different alloy compositions, and at multi-million-atom scales. Moreover, such predictions can be carried out using only modest computational resources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SPEQTACLE: An automated generalized fuzzy C-means algorithm for tumor delineation in PET

Purpose: Accurate tumor delineation in positron emission tomography (PET) images is crucial in oncology. Although recent methods achieved good results, there is still room for improvement regarding tumors with complex shapes, low signal-to-noise ratio, and high levels of uptake heterogeneity. Methods: The authors developed and evaluated an original clustering-based method called spatial positron emission quantification of tumor—Automatic Lp-norm estimation (SPEQTACLE), based on the fuzzy C-means (FCM) algorithm with a generalization exploiting a Hilbertian norm to more accurately account for the fuzzy and non-Gaussian distributions of PET images. An automatic and reproducible estimation scheme of the norm on an image-by-image basis was developed. Robustness was assessed by studying the consistency of results obtained on multiple acquisitions of the NEMA phantom on three different scanners with varying acquisition parameters. Accuracy was evaluated using classification errors (CEs) on simulated and clinical images. SPEQTACLE was compared to another FCM implementation, fuzzy local information C-means (FLICM) and fuzzy locally adaptive Bayesian (FLAB). Results: SPEQTACLE demonstrated a level of robustness similar to FLAB (variability of 14% ± 9% vs 14% ± 7%, p = 0.15) and higher than FLICM (45% ± 18%, p < 0.0001), and improved accuracy with lower CE (14% ± 11%) over both FLICM (29% ± 29%) and FLAB (22% ± 20%) on simulated images. Improvement was significant for the more challenging cases with CE of 17% ± 11% for SPEQTACLE vs 28% ± 22% for FLAB (p = 0.009) and 40% ± 35% for FLICM (p < 0.0001). For the clinical cases, SPEQTACLE outperformed FLAB and FLICM (15% ± 6% vs 37% ± 14% and 30% ± 17%, p < 0.004). Conclusions: SPEQTACLE benefitted from the fully automatic estimation of the norm on a case-by-case basis. This promising approach will be extended to multimodal images and multiclass estimation in future developments.

60 APPLIED LIFE SCIENCES↗

Uncertainty Quantification and Sensitivity Analysis of Low-Dimensional Manifold via Co-Kurtosis PCA in Combustion Modeling

For multi-scale multi-physics applications e.g., the turbulent combustion code Pele, robust and accurate dimensionality reduction is crucial to solving problems at exascale and beyond. A recently developed technique, Co-Kurtosis based Principal Component Analysis (CoK-PCA) which leverages principal vectors of co-kurtosis, is a promising alternative to traditional PCA for complex chemical systems. To improve the effectiveness of this approach, we employ Artificial Neural Networks for reconstructing thermo-chemical scalars, species production rates, and overall heat release rates corresponding to the full state space. Our focus is on bolstering confidence in this deep learning based non-linear reconstruction through Uncertainty Quantification (UQ) and Sensitivity Analysis (SA). UQ involves quantifying uncertainties in inputs and outputs, while SA identifies influential inputs. One of the noteworthy challenges is the computational expense inherent in both endeavors. To address this, we employ the Monte Carlo methods to effectively quantify and propagate uncertainties in our reduced spaces while managing computational demands. Our research carries profound implications not only for the realm of combustion modeling but also for a broader audience in UQ. By showcasing the reliability and robustness of CoK-PCA in dimensionality reduction and deep learning predictions, we empower researchers and decision-makers to navigate complex combustion systems with greater confidence.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model reduction for fractured porous media: a machine learning approach for identifying main flow pathways

Discrete fracture networks (DFN) are often used to model flow and transport in fractured porous media. The accurate resolution of flow and transport behavior on a large DFN involving thousands of fractures is computationally expensive. This makes uncertainty quantification studies of quantities of interest such as travel time through the network computationally intractable, since hundreds to thousands of runs of the DFN model are required to get bounds on the uncertainty of the predictions. Prior works on the subject demonstrated that the complexity of a DFN could be reduced by considering a sub-network of it (often termed a “backbone” sub-network), one whose flow and transport properties were then shown to be similar to that of the full network. The technique is tantamount to partitioning the complete set of fractures of a network into two disjoint sets, one of which is the backbone sub-network while the other its complement. It is in this context that we present a system-reduction technique for DFNs using supervised machine learning via a Random Forest Classifier that selects a backbone sub-network from the full set of fractures. The in-sample errors (in terms of precision and recall scores) of the trained classifier are found to be very accurate indicators of the out-of-sample errors, thus exhibiting that the classifier generalizes well to test data. Moreover, this system-reduction technique yields sub-networks as small as 12% of the full DFN that still recover transport characteristics of the full network such as the peak dosage and tailing behavior for late times. Most importantly, the sub-networks remain connected, and their size can be controlled by a single dimensionless parameter. Furthermore, measures of KL-divergence and KS-statistic for the breakthrough curves of the sub-networks with respect to the full network show physically realistic trends in that the measures decrease monotonically as the size of the sub-networks increase. In conclusion, the computational efficiency gained by this technique depends on the size of the sub-network, but large reductions in computational time can be expected for small sub-networks, yielding as much as 90% computational savings for sub-networks that are as small as 10-12% of the full network.

97 MATHEMATICS AND COMPUTING↗

On-line Generation and Error Handling for Surrogate Models within Multifidelity Uncertainty Quantification

Uncertainty quantification is recognized as a fundamental task to obtain predictive numerical simulations. However, many realistic engineering applications require complex and computationally expensive high-fidelity numerical simulations for the accurate characterization of the system responses. Moreover, complex physical models and extreme operative conditions can easily lead to hundreds of uncertain parameters that need to be propagated through high-fidelity codes. Under these circumstances, a single fidelity approach, i.e. a workflow that only uses high-fidelity simulations to perform the uncertainty quantification task, is unfeasible due to the prohibitive overall computational cost. In recent years, multifidelity strategies have been introduced to overcome this issue. The core idea of this family of methods is to combine simulations with varying levels of fidelity/accuracy in order to obtain the multifidelity estimators or surrogates with the same accuracy of their single fidelity counterparts at a much lower computational cost. This goal is usually accomplished by defining a prioria sequence of discretization levels or physical modeling assumptions that can be used to decrease the complexity of a numerical realization and thus its computational cost. However ,less attention has been dedicated to low-fidelity models that can be built directly from the small number of high-fidelity simulations available. In this work we focus our attention on Reduced-Order Models that can be considered a particular class of data-driven approaches. Our main goal is to explore the combination of multifidelity uncertainty quantification and reduced-order models to obtain an efficient framework for propagating uncertainties through expensive numerical codes.

97 MATHEMATICS AND COMPUTING↗

Evaluation of in vivo quantification accuracy of the Ingenuity-TF PET/MR

Purpose: The quantitative accuracy of standardized uptake values (SUVs) and tracer kinetic uptake parameters in patient investigations strongly depends on accurate determination of regional activity concentrations in positron emission tomography (PET) data. This determination rests on the assumption that the given scanner calibration is valid in vivo. In a previous study, we introduced a method to test this assumption. This method allows to identify discrepancies in quantitative accuracy in vivo by comparison of activity concentrations of urine samples measured in a well-counter with activity concentrations extracted from PET images of the bladder. In the present study, we have applied this method to the Philips Ingenuity-TF PET/MR since at the present stage, absolute quantitative accuracy of combined PET/MR systems is still under investigation. Methods: Twenty one clinical whole-body F18-FDG scans were included in this study. The bladder region was imaged as the last bed position and urine samples were collected afterward. PET images were reconstructed including MR-based attenuation correction with and without truncation compensation and 3D regions-of-interest (ROIs) of the bladder were delineated by three observers. To exclude partial volume effects, ROIs were concentrically shrunk by 8–10 mm. Then, activity concentrations were determined in the PET images for the bladder and for the urine by measuring the samples in a calibrated well-counter. In addition, linearity measurements of SUV vs singles rate and measurements of the stability of the coincidence rate of “true” events of the PET/MR system were performed over a period of 4 months. Results: The measured in vivo activity concentrations were significantly lower in PET/MR than in the well-counter with a ratio of the former to the latter of 0.756 ± 0.060 (mean ± std. dev.), a range of 0.604–0.858, and a P value of 3.9 ⋅ 10{sup −14}. While the stability measurements of the coincidence rate of “true” events showed no relevant deviation over time, the linearity scans revealed a systematic error of 8%–11% (avg. 9%) for the range of singles rates present in the bladder scans. After correcting for this systematic bias caused by shortcomings of the manufacturers calibration procedure, the PET to well-counter ratio increased to 0.832 ± 0.064 (0.668 –0.941), P = 1.1 ⋅ 10{sup −10}. After compensating for truncation of the upper extremities in the MR-based attenuation maps, the ratio further improved to 0.871 ± 0.069 (0.693–0.992), P = 3.9 ⋅ 10{sup −8}. Conclusions: Our results show that the Philips PET/MR underestimates activity concentrations in the bladder by 17%, which is 7 percentage points (pp.) larger than in the previously investigated PET and PET/CT systems. We attribute this increased underestimation to remaining limitations of the MR-based attenuation correction. Our results suggest that only a 2 pp. larger underestimation of activity concentrations compared to PET/CT can be observed if compensation of attenuation truncation of the upper extremities is applied. Thus, quantification accuracy of the Philips Ingenuity-TF PET/MR can be considered acceptable for clinical purposes given the ±10% error margin in the EANM guidelines. The comparison of PET images from the bladder region with urine samples has proven a useful method. It might be interesting for evaluation and comparison of the in vivo quantitative accuracy of PET, PET/CT, and especially PET/MR systems from different manufacturers or in multicenter trials.

60 APPLIED LIFE SCIENCES↗

A prediction interval method for uncertainty quantification of regression models

This paper considers calculation of prediction intervals (PIs) by neural networks (NNs) for quantifying uncertainty in regression tasks, so as to provide fast, accurate and robust emulators to accelerate scientific simulations. We propose a novel method to learn lower and upper bounds of the PI using independent NNs without defining an exclusive loss. Our method requires no distributional assumption, does not introduce extra hyper-parameters, and can effectively identify out-of-distribution samples and quantify their uncertainty. We demonstrate advantages of our method using a benchmark problem and two real-world scientific applications.

Zhang, Pei↗