Search NASA⌕ Search

SEARCH · Search NASA

Results for “active source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Distribution Substation Planning Toolkit (dsp-toolkit) v1.0

The Distribution Substation Planning Toolkit (DSP Toolkit) is a software suite designed to streamline the planning and optimization of distribution substations. This toolkit offers a comprehensive set of tools and APIs for data curation, short-term electric load forecasting, and weather-sensitive load adjustment, making it an essential resource for utility companies, engineers, and researchers. Features • Data Preprocessing and Curation: Efficiently manage and preprocess large datasets to ensure high-quality input for analysis. • Short-Term Load Forecasting: Utilize data-driven models to predict short-term electric loads accurately. • Weather-Sensitive Modeling: Automatically adjust load forecasts based on weather data to predict future peak demands more precisely. Uses The DSP Toolkit is ideal for planning and optimizing distribution substations, providing a user-friendly interface and comprehensive documentation. It is suitable for both novice and experienced users, facilitating efficient and accurate planning processes. Advantages • Efficiency: Automates complex planning tasks, reducing manual effort and minimizing errors. • Scalability: Handles large datasets and complex models, making it suitable for large-scale projects. • Community and Support: Open-source with active community contributions, ensuring continuous improvement and support. • Extensibility: Easily extendable with custom modules and plugins, allowing users to tailor the toolkit to their specific needs. The DSP Toolkit stands out by offering a robust, flexible, and user-friendly solution for distribution substation planning. Public Abstract

Li, Han [Lawrence Berkeley National Laboratory (LB↗

Brady's Geothermal Field DAS Vibroseis Data

The submitted data correspond to the monitored vibrations caused by a vibroseis seismically exciting the ground in the vertical direction and captured by the DAS horizontal and vertical arrays during the PoroTomo Experiment. The data also include a file with the acceleration record at the Vibroseis. Vibroseis Sweep Details: Sweep on location T84 Stage 4 (Mode P 60 s long record ) Time: 2016-03-25 14:01:15 (UTC) Location: 39.80476089N, -119.0027625W Elevation: 1272.0M (on ground surface at the site) Sweep length: 20 seconds Frequencies: 5 Hz to 20 Hz

15 GEOTHERMAL ENERGY↗

Brady's Geothermal Field - Map of DAS, Nodal, Vibroseis and Reftek Station Deployment

Map of DAS, nodal, vibroseis and Reftek stations during March 2016 deployment. The plot on the left has nodal stations labeled; the plot on the right has vibroseis observations labeled. Stations are shown in map-view using Brady's rotated X-Y coordinates with side plots denoting elevation with respect to the WGS84 ellipsoid. Blue circles denote vibroseis data, x symbols denote DAS (cyan for horizontal and magenta for vertical), black asterisks denote Reftek data, and red plus signs denote nodal data. This map can be found on UW-Madison's askja server at /PoroTomo/DATA/MAPS/Deployment_Stations.pdf

15 GEOTHERMAL ENERGY↗

Utah FORGE: 2D and 3D Seismic Data

This set of data contains raw and Initially-processed 2D and 3D seismic data from the Utah FORGE study area near Roosevelt Hot Springs. Reprocessed versions of these data can be accessed at the linked submission in the Resources section titled "Reprocessed Seismic Reflection Data." The zipped archives numbered from 1-100 to 1001-1122 contain 3D seismic uncorrelated shot gatherers SEG-Y files. The zipped archives numbered from 1-100C to 1001-1122C contain 3D seismic correlated shot gatherers SEG-Y files. Other data have intuitive names.

15 GEOTHERMAL ENERGY↗

Brady Hot Springs Seismic Modeling Data for Push-Pull Project

This submission includes synthetic seismic modeling data for the Push-Pull project at Brady Hot Springs, NV. The synthetic seismic is all generated by finite-difference method regarding different fracture and rock properties.

15 GEOTHERMAL ENERGY↗

2D Seismic Profiles, Nevada Play Fairway - Granite Springs Valley

This data is associated with the Nevada Play Fairway project and contains 2D seismic profile data in cropped jpegs and tiffs, both interpreted and uninterpreted. Seismic data owned or controlled by Seismic Exchange, Inc.; interpretation is that of the University of Nevada, Reno.

15 GEOTHERMAL ENERGY↗

Brady's Geothermal Field Nodal Seismometer Data

This submission includes links to raw data, field notes, metadata, and p-wave arrival auto-picks from processed data (not provided) from the nodal seismometer array deployed at the PoroTomo Natural Laboratory in Brady's Hot Springs, Nevada during the March 2016 testing. The data is available as continuous or windowed (to vibroseis sweep) files and is stored in an AWS S3 bucket. Note: No raw data was recovered from stations 73 and 82. These data are available for download without login credentials through the free and publicly accessible Open Energy Data Initiative (OEDI) data viewer which allows users to browse and download individual or groups of files.

15 GEOTHERMAL ENERGY↗

On the mechanisms of stress relaxation and intensification at the lithium/solid-state electrolyte interface

Under electrochemical cycling, stress intensification and relaxation within small volumes at the lithium/solid-state electrolyte (SSE) interface are thought to be critical factors contributing to mechanical failure of the SSE and subsequent short-circuiting of the device. Nanoindentation has been used to examine the diffusion-limited pressure lithium can support in the absence of active dislocation sources at high homologous temperatures. Based on the underlying physics of this deformation mechanism, a simple perturbation model coupling local current density, elastic stress, and diffusional creep relaxation is introduced. Combining this analysis with the indentation results, it is possible to describe a defect length scale which is too large for effective diffusional creep relaxation, but too small for efficient dislocation multiplication. In this instance, the properties of the SSE may become critical, and relevant indentation results of the SSE are described. Lastly, the final outcome of the proposed analysis is a newly developed deformation mechanism map.

36 MATERIALS SCIENCE↗

Collaborative Research. Atmospheric Pressure Microplasma Chemistry-Photon Synergies

Combining the effects of low temperature, atmospheric pressure microplasmas and microplasma photon sources offers the promise of greatly expanding the range of applications for each of them. The plasma sources create active chemical species and these can be activated further by the addition of photons and the associated photochemistry. There are many ways to combine the effects of plasma chemistry and photochemistry, especially if there are multiple phases present. This project combined the construction of appropriate test experimental systems, various spectroscopic diagnostics and mathematical modeling. Through a continuous discussion and co-design process with the UC-Berkeley Team, we have successfully completed the fabrication and testing of all components for a microplasma array-assisted system designed for photon-activated plasma chemistry research. Microcavity plasma lamps capable of generating more than 20 mW/cm 2 at 172 nm (Xe dimer) were fabricated with a custom form factor to mate to the plasma chemistry setup, and a lamp was current being installed by the Berkeley team so as to investigate plasma chemistry-photon synergies at a higher photon energy (~7.2 eV) as compared to the UVA treatment that is afforded by UV LEDs operating at 365 nm. In particular, motivated by the promising results from the Berkeley team with UVA treatment, we also produced the first generation of lamps that can generate photons in the 300-370 nm wavelength range. Another set of experiments, conducted under the auspices of this grant, involved the use of plasma microjet arrays. The combination of the photons and excited radicals produced by the plasma column resulted in broad area deactivation of bacteria.

99 GENERAL AND MISCELLANEOUS↗

Collaborative Research: Atmospheric Pressure Microplasma Chemistry-Photon Synergies Final Report

Combining the effects of low temperature, atmospheric pressure microplasmas and microplasma photon sources shows greatly expanded range of applications of each of them. The plasma sources create active chemical species and these can be activated further by addition of photons and associated photochemistry. There are many ways to combine the effects of plasma chemistry and photochemistry, especially if there are multiple phases present. The project combines construction of appropriate test experimental systems, various spectroscopic diagnostics and mathematical modeling.

47 OTHER INSTRUMENTATION↗

Final report of a scalable, automated, semipermanent seismic array (SASSA) method for detecting CO 2 extent during geologic CO 2 injection

The scalable, automated, semipermanent seismic array (SASSA) project led and managed by the Energy & Environmental Research Center (EERC) was designed as a 3-year proof-of-concept study to evaluate and demonstrate an innovative application of the seismic method. The concept was to use a sparse surface array of 96 nodal seismic sensors paired with a single, remotely operated active seismic source at a fixed location to monitor for CO 2 saturation changes in a subsurface reservoir by processing the data for time-lapse changes at individual, strategically chosen reservoir reflection points. The combination of autonomous equipment and modern processing algorithms was used to apply the seismic method in a manner different from the normal paradigm of collecting a spatially dense data set to produce an image. It was used instead to monitor individual, strategically chosen reservoir reflection points for detectable signal character changes that could be attributed to the passing of a CO 2 saturation front or, possibly, changes in reservoir pressure. Data collection occurred over the course of 1 year at an oil field undergoing CO 2 injection for enhanced oil recovery (EOR) and focused on four overlapping “five-spot” EOR injector–producer patterns. Selection, procurement, configuration, installation, and testing of project equipment and collection of five baseline data sets were completed in advance of CO 2 injection within the study area. Weekly remote data collection produced 41 incremental time-lapse records for each of the 96 nodes. Validation was provided by two methods: 1) a conventional 2-D seismic line acquired through the center of the study area before injection started and again after the project ended and processed in a time-lapse manner and 2) by CO 2 saturation maps created from reservoir simulations based on injection and production history matching. Interpreted results were encouraging but mixed, with indications of changes likely due to the presence of CO 2 on some node reflection points where and when effects would be expected and noneffects where no CO 2 was expected, while results at some locations where simulation outputs suggested CO 2 should be present were ambiguous. Acquisition noise impacted interpretation of data at several locations. Many lessons learned were generated by the study to inform and improve results on a follow-up study. The ultimate aim of the project was to evaluate whether deployment of a SASSA technology can provide a useful and cost-effective monitoring solution for future CO 2 injection projects. The answer appears to be affirmative, with the expectation that lessons learned applied to future iterations, together with technology advances, will likely result in significant improvements.

58 GEOSCIENCES↗

Probabilistic Economic Valuation of Safety Margin Management

The goal of this project was to explore a new methodology for evaluation of potential safety margin upgrades to add a new instrument to the Risk Informed Safety Margin Characterization (RISMC) toolkit. To this end, the RAVEN code developed by the Idaho National Laboratory was used to perform a cost-benefit analysis of several potential power plant safety upgrades to compare the material cost of the upgrades with the probabilistic benefit of avoiding accident scenario consequences to find the most cost-effective safety upgrades. By coupling RAVEN to MELCOR to drive Monte-Carlo method stochastic parameter analysis and using data from existing nuclear codes, as well as MELCOR’s radionuclide relocation tracking capabilities, the radionuclide release source term activity in a severe accident scenario can be estimated. Severe Accident Mitigation upgrades were benchmarked against the Hardened Containment Ventilation upgrade mandated by the USNRC for Mk1 BWRs using dollars spent per Curie of release prevented as a metric by which to evaluate the economic efficacy of the upgrades. Additionally, Fault Tree/Event Tree-based analyses were performed to compare older methods of evaluation to the methodology pioneered in this work, and Monthly Operating Report (MORP) outage data was analyzed for insights into power plant outage optimization and reduction.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report of the Sixth Regional Review Meeting of the Radiological Security Partnership.

The Sri Lanka Atomic Energy Regulatory Commission (AERC) and the United States Department of Energy (U.S. DOE) co-hosted the 6th Regional Review Meeting on Radiological Security involving representatives from over 20 countries, the International Atomic Energy Agency (IAEA), the International Criminal Police Organization (INTERPOL), and the World Institute for Nuclear Security. The purpose of the event was to discuss the implementation of, and plans for, high-activity radioactive source security (RSS). The U.S. DOE’s National Nuclear Security Administration (NNSA) Office of Radiological Security (ORS) fully sponsored this review meeting. Participants were welcomed to Colombo, Sri Lanka, and the meeting was formally opened by Nirmali Karunarathna of the Sri Lanka Atomic Energy Regulator Council who emphasized the strong partnerships among the participants. The opening Ceremony and Lamp Lighting included dignitaries from the sponsoring countries. Robert Hilton, Deputy Chief of Mission at the U.S. Embassy in Colombo, and Kristin Hirsch of the ORS gave other opening remarks that highlighted the social benefit from radiological sources in medicine, industry, and agriculture, while stressing the importance of addressing the risks associated with the malicious use of radiological sources. Emphasis was placed on the importance of partnerships among all the participants to help ensure the success of securing radiological materials throughout the world and the opportunity to share information and experiences. AERC was acknowledged with special thanks for hosting this event. A participant list is included as Attachment A, and the meeting agenda is provided as Attachment B. All presentations were made available to participants. The following sections summarize the meeting’s presentations, discussions, issues, suggestions, and recommendations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Oak Ridge National Laboratory Shutdown Dose Rate Code Suite

The Oak Ridge National Laboratory (ORNL) shutdown dose rate (SDDR) code suite calculates gamma dose rates at a location of interest due to activation of materials. The code suite is based on the rigorous two-step (R2S) method that involves two radiation transport calculations: (1) neutron radiation transport to determine neutron fluxes in the material for which activation calculations will be performed and (2) gamma radiation transport to determine dose rates at a location of interest, due to material activation. The ORNL SDDR code suite is used to determine an importance function that characterizes the neutron’s importance to the final SDDR when the Monte Carlo radiation transport method is used. This report demonstrates how the ORNL SDDR code suite is implemented through the following codes: Monte Carlo N-Particle (MCNP) code Version 5-1.60, Oak Ridge Isotope Generator (ORIGEN), MSX suite of utilities, Neutron Activation Gamma Source Sampler (NAGSS), and Automated Variance Reduction Generator (ADVANTG). For this demonstration, the International Thermonuclear Experimental Reactor (ITER) SDDR benchmark problem is used and the dose rate result is compared to previously published work.

61 RADIATION PROTECTION AND DOSIMETRY↗

United States Nuclear Data Program Annual Report for FY2021

The US Nuclear Data Program (USNDP) Annual Report for Fiscal Year 2021 (FY21) summarizes the work of USNDP for the period of October 1, 2020 through September 30, 2021, with respect to the Work Plan for FY21 that was prepared in 2019. The Work Plan and Final Report for USNDP are prepared for the DOE Office of Science, Office of Nuclear Physics. The support for the nuclear data activity from sources outside the nuclear data program is described in the staffing table and in Appendix A. This leverage amounts to about 3.24 FTE scientific, to be compared with 25.095 FTEs at USNDP units funded by the DOE Office of Science, Office of Nuclear Physics. Since it is often difficult to separate accomplishments funded by various sources, some of the work reported in the present report was accomplished with nuclear data program support leveraged by other funding.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rapid, Approximate Multi-Axis Vibration Testing [Slides]

Sequential single-axis testing provides a poor approximation of service environments. Multi-axis vibration tests are not yet standard practice. How good do multi-axis tests need to be to replace single-axis testing in practice? Is the simplest possible multi-axis test close to single-axis testing in test quality? Can single-axis testing techniques provide a sufficient rapid approximation to a multi-axis test? How much can we improve multi-axis test quality by optimizing passive test fixture hardware instead of adding active excitation sources?

42 ENGINEERING↗