Search NASA⌕ Search

SEARCH · Search NASA

Results for “automatic loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Developing Ultrahigh-Resolution E3SM Land Model for GPU Systems

Designing and refactoring complex scientific code, such as the E3SM land model (ELM), for new computing architectures is challenging. This paper presents design strategies and technical approaches to develop a data-oriented, GPU-ready ELM model using compiler directives (OpenACC/OpenMP). We first analyze the datatypes and processes in the original ELM code. Then we present design considerations for ultrahigh-resolution ELM (uELM) development for massive GPU systems. These techniques include the global data-oriented simulation workflow, domain partition, code porting and data copy, memory reduction, parallel loop restructure and flattening, and race condition detection. We implemented the first version of uELM using OpenACC targeting the NVidia GPUs in the Summit supercomputer at Oak Ridge National Laboratory. During the implementation, we developed a software tool (named SPEL) to facilitate code generation, verification, and performance tuning using these techniques. The first uELM implementation for Nvidia GPUs on Summit delivered promising results: 1) over 98% of the ELM code was automatically generated and tuned by scripts. Most ELM modules had better computational performances than the original ELM code for CPUs. The GPU-ready uELM is more scalable than the CPU code on fully-loaded Summit nodes. Example profiling results from several modules are also presented to illustrate the performance improvements and race condition detection. The lessons learned and toolkit developed in the study are also suitable for further uELM deployment using OpenMP on the first US exascale computer, Frontier, equipped with AMD CPUs and GPUs.

Schwartz, Peter↗

The PR2D (Place, Route in 2-Dimensions) automatic layout computer program handbook

Place, Route in 2-Dimensions is a standard cell automatic layout computer program for generating large scale integrated/metal oxide semiconductor arrays. The program was utilized successfully for a number of years in both government and private sectors but until now was undocumented. The compilation, loading, and execution of the program on a Sigma V CP-V operating system is described.

Edge, T. M.↗

Control system for an induction motor with energy recovery

A control circuit for an induction motor powered system is disclosed in which a power factor controlled servo loop is used to control, via the phase angle of firing of a triac, the power input to the motor, as a function of load placed on the motor by machinery of the powered system. Then, upon application of torque by this machinery to the motor, which tends to overspeed the motor, the firing angle of the triac is automatically set to a fixed, and relatively short, firing angle.

Nola, F. J.↗

BWR Anticipated Transients Without Scram Leading to Instability

Anticipated transients without scram (ATWS) in aboiling water reactor (BWR) were simulated in order to understand reactor response and determine the effectiveness of automatic and operator actions to mitigate this beyond-design-basis accident. The events of interest herein are initiated by a turbine trip when the reactor is operating in the expanded operating domainMELLLA+ [maximum extended load line limit plus]. In these events the reactor may initially be at up to 120% of the original licensed thermal power (OLTP) and at flow rates as low as 80% of rated.For these (and similar) ATWS events the concern isthat when the reactor power decreases in response to a dual recirculation pump trip, the core will become unstable and large amplitude oscillations will begin. The occurrence of these power oscillations, if left unmitigated, may result in fuel damage, and the amplitude of the poweroscillations may hamper the effectiveness of the injection of dissolved neutron absorber through the standby liquid control system (SLCS).

42 ENGINEERING↗

Stochastic Multi-Timescale Power System Operations With Variable Wind Generation

This paper describes a novel set of stochastic unit commitment and economic dispatch models that consider stochastic loads and variable generation at multiple operational timescales. The stochastic model includes four distinct stages: stochastic day-ahead security-constrained unit commitment (SCUC), stochastic real-time SCUC, stochastic real-time security-constrained economic dispatch (SCED), and deterministic automatic generation control (AGC). These sub-models are integrated together such that they are continually updated with decisions passed from one to another. The progressive hedging algorithm (PHA) is applied to solve the stochastic models to maintain the computational tractability of the proposed models. Comparative case studies with deterministic approaches are conducted in low wind and high wind penetration scenarios to highlight the advantages of the proposed methodology, one with perfect forecasts and the other with current state-of-the-art but imperfect deterministic forecasts. The effectiveness of the proposed method is evaluated with sensitivity tests using both economic and reliability metrics to provide a broader view of its impact.

17 WIND ENERGY↗

DISTRI: Distributed Multi-Facility HPC Simulator (DISTRI) v2.1

DISTRI is an advanced network simulator designed for multi-facility computational infrastructures with agentic behavior. It simulates HPC facilities where computational resources act as autonomous agents, making intelligent decisions about job scheduling, load balancing, and resource allocation. The simulator focuses on developing and testing decentralized algorithms that promote resilience and efficiency in multi-facility environments. Key Features: - Agentic Resource Behavior: Processors and DTNs act as autonomous agents with decision-making capabilities - Pheromone-Based Load Balancing: Decentralized load balancing inspired by ant colony optimization - Dual Topology Support: Mesh (normal operations) and Dumbell (network testing) topologies - Comprehensive TCP Simulation: Realistic TCP implementations with multiple congestion control algorithms - Failure Resilience Testing: Processor failure simulation with automatic job reassignment - Extensive Visualization: Detailed performance analysis and metrics collection - Research-Ready: Designed for algorithm development and benchmarking

Bez, Jean Luca [Lawrence Berkeley National Laborat↗

Power-Factor Controller With Regenerative Braking

Modified power-factor motor-control circuit operates motor as a phase-controlled generator when load attempts to turn at higher than synchronous speed. An induction motor is required to act at times as a brake. Circuit modification allows power-factor controller to save energy in motoring mode and convert automatically to an induction-generator controller in generating, or braking, mode.

Nola, F. J.↗

Control Electronics for Solar/Flywheel Power Supply

Control circuit automatically directs flow of electrical energy to and from motor with flywheel that constitutes storage element of solar-power system. When insolation is sufficient for charging, power is supplied by solar-cell array to load and motor. During periods of darkness, motor made to act as generator, drawing kinetic energy from flywheel and supplying it to load.

Nola, F. J.↗

Ultrasonic Ranging System With Increased Resolution

Master-oscillator frequency increased. Ultrasonic range-measuring system with 0.1-in. resolution provides continuous digital display of four distance readings, each updated four times per second. Four rangefinder modules in system are modified versions of rangefinder used for automatic focusing in commercial series of cameras. Ultrasonic pulses emitted by system innocuous to both people and equipment. Provides economical solutions to such distance-measurement problems as posed by boats approaching docks, truck backing toward loading platform, runway-clearance readout for tail of airplane with high angle attack, or burglar alarm.

Meyer, William E.↗

Proof that timing requirements of the FDDI token ring protocol are satisfied

The fiber distributed data interface (FDDI) is an ANSI draft proposed standard for a 100 Mbit/s fiber-optic token ring. The FDDI timed token access protocol provides dynamic adjustment of the load offered to the ring, with the goal of maintaining a specified token rotation time and of providing a guaranteed upper bound on time between successive arrivals of the token at a station. FDDI also provides automatic recovery when errors occur. The bound on time between successive token arrivals is guaranteed only if the token rotates quickly enough to satisfy timer requirements in each station when all ring resources are functioning properly. Otherwise, recovery would be initiated unnecessarily. The purpose of this paper is to prove that FDDI timing requirements are satisfied, i.e., the token rotates quickly enough to prevent initiation of recovery unless there is failure of a physical resource or unless the network management entity within a station initiates the recovery process.

Johnson, Marjory J.↗

Applications of photogrammetry to structural assessment

Photogrammetry is a method developed in the early XIXth century. Nowadays, with digital photography associated to the development of image processing and its automation, this technique has become appealing in different fields of application. In this paper, the authors analysed the current feasibility and advantages of using photogrammetry in structural monitoring. First, the method was calibrated using two laboratorial tests: (1) monitoring of failure and creep tests of long-span reinforced concrete beams; and (2) monitoring of steel beam-to-column connections. Then, the method was tested on site, namely, in monitoring the deformations of a footbridge subjected to different loading situations. It was concluded that photogrammetry can be used in structural monitoring with accuracy and exhibiting additional advantages in relation to traditional methods, namely: (1) an almost unlimited number of measuring points can be considered and automatically processed; and (2) hardware is unnecessary and, therefore, it can be used under almost any situation where traditional methods cannot be employed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Training and subjective workload in a category search task

This study examined automaticity as a means by which training influences mental workload. Two groups were trained in a category search task. One group received a training paradigm designed to promote the development of automaticity; the other group received a training paradigm designed to prohibit it. Resultant performance data showed the expected improvement as a result of the development of automaticity. Subjective workload assessments mirrored the performance results in most respects. The results supported the position that subjective mental workload assessments may be sensitive to the effect of training when it produces a lower level of cognitive load.

Vidulich, Michael A.↗

Electrical performance characteristics of high power converters for space power applications

The first goal of this project was to investigate various converters that would be suitable for processing electric power derived from a nuclear reactor. The implementation is indicated of a 20 kHz system that includes a source converter, a ballast converter, and a fixed frequency converter for generating the 20 kHz output. This system can be converted to dc simply by removing the fixed frequency converter. This present study emphasized the design and testing of the source and ballast converters. A push-pull current-fed (PPCF) design was selected for the source converter, and a 2.7 kW version of this was implemented using three 900 watt modules in parallel. The characteristic equation for two converters in parallel was derived, but this analysis did not yield any experimental methods for measuring relative stability. The three source modules were first tested individually and then in parallel as a 2.7 kW system. All tests proved to be satisfactory; the system was stable; efficiency and regulation were acceptable; and the system was fault tolerant. The design of a ballast-load converter, which was operated as a shunt regulator, was investigated. The proposed power circuit is suitable for use with BJTs because proportional base drive is easily implemented. A control circuit which minimizes switching frequency ripple and automatically bypasses a faulty shunt section was developed. A nonlinear state-space-averaged model of the shunt regulator was developed and shown to produce an accurate incremental (small-signal) dynamic model, even though the usual state-space-averaging assumptions were not met. The nonlinear model was also shown to be useful for large-signal dynamic simulation using PSpice.

Stuart, Thomas A.↗

Thermal Vacuum Testing of a Proto-flight Miniature Loop Heat Pipe with Two Evaporators and Two Condensers

This paper describes thermal vacuum testing of a proto-flight miniature loop heat pipe (MLHP) with two evaporators and two condensers designed for future small systems applications requiring low mass, low power and compactness. Each evaporator contains a wick with an outer diameter of 6.35 mm, and each has its own integral compensation chamber (CC). Miniaturization of the loop components reduces the volume and mass of the thermal system. Multiple evaporators provide flexibility for placement of instruments that need to be maintained at the same temperature, and facilitate heat load sharing among instruments, reducing the auxiliary heater power requirement. A flow regulator is used to regulate heat dissipations between the two condensers, allowing flexible placement of radiators on the spacecraft. A thermoelectric converter (TEC) is attached to each CC for control of the operating temperature and enhancement of start-up success. Tests performed include start-up, power cycle, sink temperature cycle, high power and low power operation, heat load sharing, and operating temperature control. The proto-flight MLHP demonstrated excellent performance in the thermal vacuum test. The loop started successfully and operated stably under various evaporator heat loads and condenser sink temperatures. The TECs were able to maintain the loop operating temperature within b1K of the desired set point temperature at all power levels and all sink temperatures. The un-powered evaporator would automatically share heat from the other powered evaporator. The flow regulator was able to regulate the heat dissipation among the radiators and prevent vapor from flowing into the liquid line.

Ku, Jentung↗

KG-Hub—building and exchanging biological knowledge graphs

Knowledge graphs (KGs) are a powerful approach for integrating heterogeneous data and making inferences in biology and many other domains, but a coherent solution for constructing, exchanging, and facilitating the downstream use of KGs is lacking. Here we present KG-Hub, a platform that enables standardized construction, exchange, and reuse of KGs. Features include a simple, modular extract–transform–load pattern for producing graphs compliant with Biolink Model (a high-level data model for standardizing biological data), easy integration of any OBO (Open Biological and Biomedical Ontologies) ontology, cached downloads of upstream data sources, versioned and automatically updated builds with stable URLs, web-browsable storage of KG artifacts on cloud infrastructure, and easy reuse of transformed subgraphs across projects. Current KG-Hub projects span use cases including COVID-19 research, drug repurposing, microbial–environmental interactions, and rare disease research. KG-Hub is equipped with tooling to easily analyze and manipulate KGs. KG-Hub is also tightly integrated with graph machine learning (ML) tools which allow automated graph ML, including node embeddings and training of models for link prediction and node classification.

59 BASIC BIOLOGICAL SCIENCES↗

Space Station Freedom main truss thermal analysis

The main truss structure of the Permanently Manned Capability configuration of the Space Station Freedom is analyzed in order to evaluate orbital heating loads and determine the temperature distributions and temperature gradients in the structure. The results are to be utilized in a thermal/structure analysis in the determination of thermal stresses and deflections in the truss members caused by solar heating loads and by shadowing of the truss members by other segments of the Space Station as it moves around the orbit. A SINDA thermal finite different model and a TRASYS radiation interchange model of the truss were generated automatically from a NASTRAN finite element structural model. The analysis yielded transient temperature distribution in the truss structure around the orbit, indicating large temperature gradients in the structure.

Warren, Andrew H.↗

Risk-Aware Planetary Rover Operation: Autonomous Terrain Classification and Path Planning

Identifying and avoiding terrain hazards (e.g., soft soil and pointy embedded rocks) are crucial for the safety of planetary rovers. This paper presents a newly developed groundbased Mars rover operation tool that mitigates risks from terrain by automatically identifying hazards on the terrain, evaluating their risks, and suggesting operators safe paths options that avoids potential risks while achieving specified goals. The tool will bring benefits to rover operations by reducing operation cost, by reducing cognitive load of rover operators, by preventing human errors, and most importantly, by significantly reducing the risk of the loss of rovers.

Ono, Masahiro↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗