Search NASA⌕ Search

SEARCH · Search NASA

Results for “best source selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Ambient monitoring to inform the protection of beneficial uses and achieve water quality goals in Sinclair and Dyes Inlets, Puget Sound, WA

Currently discharge limits enforced under the Clean Water Act are focused on meeting water quality standards at the end of the pipe and environmental performance is measured based on meeting the discharge limits; but meeting discharge limits has very little to do with achieving water quality goals for coastal and estuarine ecosystems. Therefore, an effective monitoring and assessment program is needed to assess continuous process improvement, evaluate the ecological conditions, and provide metrics that can inform effective management of coastal and estuarine water quality. As part of an integrated Environmental Investment (ENVVEST) project for Sinclair and Dyes Inlets (ENVVEST 2006; Johnston et al. 2009) a network of monitoring stations was established to characterize environmental conditions, assess potential impacts, and establish environmental quality trends within the Inlets. Water, sediment, and biota monitoring locations were selected that were co-located near suspected sources (industrial, waste water, and stormwater outfalls; marinas, stream mouths, and other sources) or were representative of ambient marine and nearshore conditions. Water column stations and effluents from industrial outfalls were sampled seasonally for trace metals (Cd, Cr, Cu, Hg, Pb, and Zn) using analytical procedures appropriate for seawater (Strivens, Brandenberger and Johnston, 2018), conventional parameters (salinity, dissolved and total organic carbon, total and suspended solids, dissolved O2, pH, turbidity, NO2+NO3, NH4, N, and P), and toxicity. Effluent and water column toxicity tests included mysid shrimp (Americamysis bahia) 96 hr survival, sand dollar (Dendraster excentricus) or purple sea urchin (Strongylocentrotus purpuratus) 96 hr embryo development, QwikLite – dinoflagellate (Pyrocystis lunula) 24 hr bioluminescence response, mussel larvae (Mytilus sp.) 48 hr larvae survival and development, and kelp (Macrocystis pyrifera) 48 hr growth and germination. Additionally, indigenous mussels (Mytilis spp.) were sampled biennially for contaminant residues of metals, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), lipid content, and stable isotopes of C and N. The mussel data were compared to benchmarks of ecological effects (Johnston et al. 2007, Applied Biomonitoring 2009), samples obtained from a local seafood market harvested from Penn Cove on Whidbey Island (PKPLPC), and data from the national mussel watch status and trends monitoring program (Kimbrough et al. 2008). Results from 2009-2016 showed that dissolved metals nearly always met water quality standards and that water quality in Navy nearshore areas appeared to improve after best management practices (BMPs) for industrial process improvements (US Navy 2012) were completed in Sept. 2013 (Figure 1). In general, toxicity from exposure to whole effluent samples was not observed and ambient water samples were not toxic to test organisms, except that ambient toxicity was only observed during the presence of algal blooms which showed that toxicity was highly correlated with the abundance of the toxic algae Gymnodinium splendens (Rosen et al. 2009). Overall, mussel tissue residues were below benchmarks at most locations (Figure 2), however there were locations that had elevated levels of PAHs, PCBs, Hg, and Cu. Results from the monitoring provide metrics that are being used to assess progress toward meeting environmental quality goals for the watershed.

ENVVEST, PSEMP↗

A review of atomic clock technology, the performance capability of present spaceborne and terrestrial atomic clocks, and a look toward the future

Clocks have played a strong role in the development of general relativity. The concept of the proper clock is presently best realized by atomic clocks, whose development as precision instruments has evolved very rapidly in the last decades. To put a historical prospective on this progress since the year AD 1000, the time stability of various clocks expressed in terms of seconds of time error over one day of operation is shown. This stability of operation must not be confused with accuracy. Stability refers to the constancy of a clock operation as compared to that of some other clocks that serve as time references. Accuracy, on the other hand, is the ability to reproduce a previously defined frequency. The issues are outlined that must be considered when accuracy and stability of clocks and oscillators are studied. In general, the most widely used resonances result from the hyperfine interaction of the nuclear magnetic dipole moment and that of the outermost electron, which is characteristic of hydrogen and the alkali atoms. During the past decade hyperfine resonances of ions have also been used. The principal reason for both the accuracy and the stability of atomic clocks is the ability of obtaining very narrow hyperfine transition resonances by isolating the atom in some way so that only the applied stimulating microwave magnetic field is a significant source of perturbation. It is also important to make resonance transitions among hyperfine magnetic sublevels where separation is independent, at least to first order, of the magnetic field. In the case of ions stored in traps operating at high magnetic fields, one selects the trapping field to be consistent with a field-independent transition of the trapped atoms.

Vessot, Robert F. C.↗

Subaru weak-lensing survey of dark matter subhalos in the Coma cluster: Subhalo mass function and statistical properties

We present a 4 deg{sup 2} weak gravitational lensing survey of subhalos in the very nearby Coma cluster using the Subaru/Suprime-Cam. The large apparent size of cluster subhalos allows us to measure the mass of 32 subhalos detected in a model-independent manner, down to the order of 10{sup –3} of the virial mass of the cluster. Weak-lensing mass measurements of these shear-selected subhalos enable us to investigate subhalo properties and the correlation between subhalo masses and galaxy luminosities for the first time. The mean distortion profiles stacked over subhalos show a sharply truncated feature which is well-fitted by a Navarro-Frenk-White (NFW) mass model with the truncation radius, as expected due to tidal destruction by the main cluster. We also found that subhalo masses, truncation radii, and mass-to-light ratios decrease toward the cluster center. The subhalo mass function, dn/dln M {sub sub}, in the range of 2 orders of magnitude in mass, is well described by a single power law or a Schechter function. Best-fit power indices of 1.09{sub −0.32}{sup +0.42} for the former model and 0.99{sub −0.23}{sup +0.34} for the latter, are in remarkable agreement with slopes of ∼0.9-1.0 predicted by the cold dark matter paradigm. The tangential distortion signals in the radial range of 0.02-2 h {sup –1} Mpc from the cluster center show a complex structure which is well described by a composition of three mass components of subhalos, the NFW mass distribution as a smooth component of the main cluster, and a lensing model from a large scale structure behind the cluster. Although the lensing signals are 1 order of magnitude lower than those for clusters at z ∼ 0.2, the total signal-to-noise ratio, S/N = 13.3, is comparable, or higher, because the enormous number of background source galaxies compensates for the low lensing efficiency of the nearby cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

A fission-fusion hybrid reactor in steady-state L-mode tokamak configuration with natural uranium

This work develops a conceptual design for a fusion-fission hybrid reactor operating in steady-state L-mode tokamak configuration with a subcritical natural or depleted uranium pebble bed blanket. A liquid lithium-lead alloy breeds enough tritium to replenish that consumed by the D-T fusion reaction. The fission blanket augments the fusion power such that the fusion core itself need not have a high power gain, thus allowing for fully non-inductive (steady-state) low confinement mode (L-mode) operation at relatively small physical dimensions. A neutron transport Monte Carlo code models the natural uranium fission blanket. Maximizing the fission power gain while breeding sufficient tritium allows for the selection of an optimal set of blanket parameters, which yields a maximum prudent fission power gain of approximately 7. A 0-D tokamak model suffices to analyze approximate tokamak operating conditions. This fission blanket would allow the fusion component of a hybrid reactor with the same dimensions as ITER to operate in steady-state L-mode very comfortably with a fusion power gain of 6.7 and a thermal fusion power of 2.1 GW. Taking this further can determine the approximate minimum scale for a steady-state L-mode tokamak hybrid reactor, which is a major radius of 5.2 m and an aspect ratio of 2.8. This minimum scale device operates barely within the steady-state L-mode realm with a thermal fusion power of 1.7 GW. Basic thermal hydraulic analysis demonstrates that pressurized helium could cool the pebble bed fission blanket with a flow rate below 10 m/s. The Brayton cycle thermal efficiency is 41%. This reactor, dubbed the Steady-state L-mode non-Enriched Uranium Tokamak Hybrid (SLEUTH), with its very fast neutron spectrum, could be superior to pure fission reactors in terms of breeding fissile fuel and transmuting deleterious fission products. It would likely function best as a prolific plutonium breeder, and the plutonium it produces could actually be more proliferation-resistant than that bred by conventional fast reactors. Furthermore, it can maintain constant total hybrid power output as burnup proceeds by varying the neutron source strength.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computational prediction of ?/?-selectivities in the pyrolysis of oxygen substituted phenethyl phenyl ethers

Lignin is a potential renewable source of oxygenated chemicals and liquid fuels, its reaction pathways are often studied using model compounds. Phenethyl phenyl ether (PPE; PhCH2CH2OPh)) is the simplest model for the most common -O-4 linkage in lignin. Previously, we developed a computational scheme to calculate the / -product selectivity in the pyrolysis of PPE by systematically exploiting error cancellation in the computation of relative rate constants. The / -selectivity is defined as the selectivity between the competitive hydrogen abstraction reaction paths on the - and -carbon of PPE. We use density functional theory and employ transition state theory where we include diagonal anharmonic correction in the vibrational partition functions for low frequency modes for which a semi-classical expression is used. In this work we investigate the effect of oxygen substituents (hydroxy, methoxy) in the para-position on the phenethyl-ring of PPE on the / -selectivities. The total / -selectivity increases when substituents are introduced and is larger for the methoxy than the hydroxy substituent. The strongest effect of the substituents is observed for the -pathway of the hydrogen abstraction by the phenoxyl chain carrying radical for which the rate increases. For the -pathway and the abstraction by the R-benzyl radical (R=OH,OCH3) the rate decreases with the introduction of the substituents. These findings are compared with results from recent experimental studies.

08 HYDROGEN↗

Rotation-Enabled 7-Degree of Freedom Seismometer for Geothermal Resource Development. Phase 1 Final Report

Under this Department of Energy (DOE) grant, A-Tech Corporation d.b.a. Applied Technology Associates (ATA), seeks to develop a seven-degree-of-freedom (7-DOF) seismic measurement tool for high-temperature geothermal applications. The Rotational-Enabled 7-DOF Seismometer includes a conventional tri-axial accelerometer, a conventional pressure sensor or hydrophone, and a tri-axial rotational sensor. The rotational sensing capability is novel, based upon ATA's innovative research in rotational sensing technologies. The geothermal industry requires tools for high-precision seismic monitoring of crack formation associated with Enhanced Geothermal System (EGS) stimulation activity. Currently, microseismic monitoring is conducted by deploying many seismic tools at different depth levels along a 'string' within drilled observation wells. Costs per string can be hundreds of thousands of dollars. Processing data from the spatial arrays of linear seismometers allows back-projection of seismic wave states. In contrast, a Rotational-Enabled 7-DOF Seismometer would simultaneously measure p-wave velocity, s-wave velocity, and incident seismic wave direction all from a single point measurement. In addition, the Rotational-Enabled 7-DOF Seismometer will, by its nature, separate p- and s-waves into different data streams, simplifying signal processing and facilitating analysis of seismic source signatures and geological characterization. By adding measurements of three additional degrees-of-freedom at each level and leveraging the information from this new seismic observable, it is likely that an equally accurate picture of subsurface seismic activity could be garnered with fewer levels per hole. The key cost savings would come from better siting of the well due to increased information content and a decrease in the number of confirmation wells drilled, also due to the increase in information per well. Improved seismic tools may also increase knowledge, understanding, and confidence, thus removing some current blocks to feasibility and significantly increasing access to potential geothermal sites. During the Phase 1 effort summarized in this final report, the ATA Team modeled and built two TRL 3 proof-of-concept test units for two competing rotational sensor technologies. The two competing technologies were based on ATA's angular rate and angular displacement measurement technologies; Angular rate: ATA's Magnetohydrodynamic Angular Rate Sensor (Seismic MHD); and Angular displacement: ATA's Low Frequency Improved Torsional Seismometer (LFITS). In order to down-select between these two technologies and formulate a go / no go decision, the ATA Team analyzed and traded scientific performance requirements and market constraints against sensor characteristics and components, acquiring field data where possible to validate the approach and publishing results from these studies of rotational technology capability. Based on the results of Phase 1, the ATA Team finds that the Seismic MHD (SMHD) technology is the best choice for enabling rotational seismometry and significant technical potential exists for micro-seismic monitoring using a downhole 7-DOF device based on the SMHD. Recent technical papers and field data confirm the potential of rotational sensing for seismic mapping, increasing confidence that cost-reduction benefits are achievable for EGS. However, the market for geothermal rotational sensing is small and undeveloped. As a result, this report recommends modifying the Phase 2 plan to focus on prototype development aimed at partnering with early adopters within the geothermal industry and the scientific research community. The highest public benefit will come from development and deployment of a science-grade SMHD rotational seismometer engineered for geothermal downhole conditions and an integrated test tool for downhole measurements at active geothermal test sites.

15 GEOTHERMAL ENERGY↗

Cosmological inference from an emulator based halo model. II. Joint analysis of galaxy-galaxy weak lensing and galaxy clustering from HSC-Y1 and SDSS

Here, we present high-fidelity cosmology results from a blinded joint analysis of galaxy-galaxy weak lensing (ΔΣ) and projected galaxy clustering (w p ) measured from the Hyper Suprime-Cam Year-1 (HSC-Y1) data and spectroscopic Sloan Digital Sky Survey (SDSS) galaxy catalogs in the redshift range 0.15 < z < 0.7. We define luminosity-limited samples of SDSS galaxies to serve as the tracers of w p in three spectroscopic redshift bins, and as the lens samples for ΔΣ. For the ΔΣ measurements, we select a single sample of 4×10 6 source galaxies over 140 deg 2 from HSC-Y1 with photometric redshifts (photo z) greater than 0.75, enabling a better handle of photo- z errors by comparing the ΔΣ amplitudes for the three lens redshift bins. The deep, high-quality HSC-Y1 data enable significant detections of the ΔΣ signals, with integrated signal-to-noise ratio S/N ~ 15 in the range 3 ≤ R/[h –1 Mpc] ≤ 30 for the three lens samples, despite the small area coverage. For cosmological parameter inference, we use an input galaxy-halo connection model built on the dark emulator package (which uses an ensemble set of high-resolution N-body simulations and enables fast, accurate computation of the clustering observables) with a halo occupation distribution that includes nuisance parameters to marginalize over modeling uncertainties. We model the ΔΣ and wp measurements on scales from R≃3 and 2h –1 Mpc , respectively, up to 30 h –1 Mpc (therefore excluding the baryon acoustic oscillations information) assuming a flat Λ CDM cosmology, marginalizing over about 20 nuisance parameters and demonstrating the robustness of our results to them. With various tests using mock catalogs described in Miyatake et al. [preceding paper, Phys. Rev. D 106, 083519 (2022)], we show that any bias in the clustering amplitude S 8 ≡ σ 8 (Ω m /0.3) 0.5 due to uncertainties in the galaxy-halo connection is less than ~ 50 % of the statistical uncertainty of S 8 , unless the assembly biaseffect is unexpectedly large. Our best-fit models have S 8 = 0.795$_{-0.042}^{+0.049}$ (mode and 68% credible interval) for the flat Λ CDM model; we find tighter constraints on the quantity S 8 (α = 0.17)≡σ 8 (Ω m /0.3) 0.17 = 0.745$_{-0.031}^{+0.039}$.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-BRA-13: Knowledge-Based Treatment Planning for Prostate LDR Brachytherapy Based On Principle Component Analysis

Purpose: To create a knowledge-based algorithm for prostate LDR brachytherapy treatment planning that standardizes plan quality using seed arrangements tailored to individual physician preferences while being fast enough for real-time planning. Methods: A dataset of 130 prior cases was compiled for a physician with an active prostate seed implant practice. Ten cases were randomly selected to test the algorithm. Contours from the 120 library cases were registered to a common reference frame. Contour variations were characterized on a point by point basis using principle component analysis (PCA). A test case was converted to PCA vectors using the same process and then compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. The seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Computational time was recorded. Any subsequent modifications were recorded that required input from a treatment planner to achieve an acceptable plan. Results: The computational time required to register contours from a test case and evaluate PCA similarity across the library was approximately 10s. Five of the ten test cases did not require any seed additions, deletions, or moves to obtain an acceptable plan. The remaining five test cases required on average 4.2 seed modifications. The time to complete manual plan modifications was less than 30s in all cases. Conclusion: A knowledge-based treatment planning algorithm was developed for prostate LDR brachytherapy based on principle component analysis. Initial results suggest that this approach can be used to quickly create treatment plans that require few if any modifications by the treatment planner. In general, test case plans have seed arrangements which are very similar to prior cases, and thus are inherently tailored to physician preferences.

60 APPLIED LIFE SCIENCES↗

Tc-99 Adsorption on Selected Activated Carbons - Batch Testing Results

CH2M HILL Plateau Remediation Company (CHPRC) is currently developing a 200-West Area groundwater pump-and-treat system as the remedial action selected under the Comprehensive Environmental Response, Compensation, and Liability Act Record of Decision for Operable Unit (OU) 200-ZP-1. This report documents the results of treatability tests Pacific Northwest National Laboratory researchers conducted to quantify the ability of selected activated carbon products (or carbons) to adsorb technetium-99 (Tc-99) from 200-West Area groundwater. The Tc-99 adsorption performance of seven activated carbons (J177601 Calgon Fitrasorb 400, J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, J177612 Norit GAC830, J177613 Norit GAC830, and J177617 Nucon LW1230) were evaluated using water from well 299-W19-36. Four of the best performing carbons (J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, and J177613 Norit GAC830) were selected for batch isotherm testing. The batch isotherm tests on four of the selected carbons indicated that under lower nitrate concentration conditions (382 mg/L), Kd values ranged from 6,000 to 20,000 mL/g. In comparison. Under higher nitrate (750 mg/L) conditions, there was a measureable decrease in Tc-99 adsorption with Kd values ranging from 3,000 to 7,000 mL/g. The adsorption data fit both the Langmuir and the Freundlich equations. Supplemental tests were conducted using the two carbons that demonstrated the highest adsorption capacity to resolve the issue of the best fit isotherm. These tests indicated that Langmuir isotherms provided the best fit for Tc-99 adsorption under low nitrate concentration conditions. At the design basis concentration of Tc 0.865 µg/L(14,700 pCi/L), the predicted Kd values from using Langmuir isotherm constants were 5,980 mL/g and 6,870 mL/g for for the two carbons. These Kd values did not meet the target Kd value of 9,000 mL/g. Tests conducted to ascertain the effects of changing pH showed that at pH values of 6.5 and 7.5, no significant differences existed in Tc-adsorption performance for three of the carbons, but the fourth carbon performed better at pH 7.5. When the pH was increased to 8.5, a slight decline in performance was observed for all carbons. Tests conducted to ascertain the temperature effect on Tc-99 adsorption indicated that at 21 ºC, 27 ºC, and 32 ºC there were no significant differences in Tc-99 adsorption for three of the carbons. The fourth carbon showed a noticeable decline in Tc-99 adsorption performance with increasing temperature. The presence of volatile organic compounds (VOCs) in the source water did not significantly affect Tc-99 adsorption on either of two carbons tested. Technetium-99 adsorption differed by less than 15% with or without VOCs present in the test water, indicating that Tc-99 adsorption would not be significantly affected if VOCs were removed from the water prior to contact with carbon.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of the Effect of Surface Finish on High-Cycle Fatigue of SLM-IN718

The surface finish of parts produced by additive manufacturing processes is much rougher than the surface finish generated by machining processes, and a rougher surface can reduce the fatigue strength of a part. This paper discusses an effort to quantify that reduction of strength in high-cycle fatigue for selective laser melt (SLM) coupons. A high-cycle fatigue (HCF) knockdown factor was estimated for Inconel 718, manufactured with the SLM process. This factor is the percentage reduction from the maximum stress in fatigue for low-stress ground (LSG) specimens to the maximum stress of those left with the original surface condition at the same fatigue life. Specimens were provided by a number of vendors, free to use their "best practice"; only one heat treat condition was considered; and several test temperatures were characterized, including room temperature, 800F, 1000F, and 1200F. The 1000F data had a large variance, and was omitted from consideration in this document. A first method used linear approximations extracted from the graphs, and only where data was available for both. A recommended knockdown factor of the as-built surface condition (average roughness of approximately 245 micro-inches/inch) versus low-stress ground condition (roughness no more than 4 micro-inches/inch) was established at approximately 1/3 or 33%. This is to say that for the as-built surface condition, a maximum stress of 2/3 of the stress for LSG can be expected to produce a similar life in the as-built surface condition. In this first evaluation, the knockdown factor did not appear to be a function of temperature. A second approach, the "KP method", incorporated the surface finish measure into a new parameter termed the pseudo-stress intensity factor, Kp, which was formulated to be similar to the fracture mechanics stress intensity factor. Using Kp, the variance seemed to be reduced across all sources, and knockdown factors were estimated using Kp over the range where data occurred. A plot of the results suggests that the knockdown factor is a function of temperature, and that for low lives the knockdown might be lower than the knockdown observed above about one million cycles, where it tended to stabilize. This was not universal for all temperatures tested. The higher temperature tests are thought to be influenced by the test temperature, which perhaps continued the aging process. Further evaluation of the method is suggested.

Lambert, D. M.↗

Workshop introduction

The Department of Energy's National Nuclear Security Administration's Global Threat Reduction Initiative (GTRI) has three subprograms that directly reduce the nuclear/radiological threat; Convert (Highly Enriched Uranium), Protect (Facilities), and Remove (Materials). The primary mission of the Off-Site Source Recovery Project (OSRP) falls under the 'Remove' subset. The purpose of this workshop is to provide a venue for joint-technical collaboration between the OSRP and the Nuclear Radiation Safety Service (NRSS). Eisenhower's Atoms for Peace initiative and the Soviet equivalent both promoted the spread of the paradoxical (peaceful and harmful) properties of the atom. The focus of nonproliferation efforts has been rightly dedicated to fissile materials and the threat they pose. Continued emphasis on radioactive materials must also be encouraged. An unquantifiable threat still exists in the prolific quantity of sealed radioactive sources (sources) spread worldwide. It does not appear that the momentum of the evolution in the numerous beneficial applications of radioactive sources will subside in the near future. Numerous expert studies have demonstrated the potentially devastating economic and psychological impacts of terrorist use of a radiological dispersal or emitting device. The development of such a weapon, from the acquisition of the material to the technical knowledge needed to develop and use it, is straightforward. There are many documented accounts worldwide of accidental and purposeful diversions of radioactive materials from regulatory control. The burden of securing sealed sources often falls upon the source owner, who may not have a disposal pathway once the source reaches the end of its useful life. This disposal problem is exacerbated by some source owners not having the resources to safely and compliantly store them. US Nuclear Regulatory Commission (NRC) data suggests that, in the US alone, there are tens of thousands of high-activity (IAEA Category I and II) sources in thousands of devices; and there are many more tens of thousands of smaller sources scattered among thousands of other NRC licensees. As a result of the ubiquitous nature and undeterminable number of current and legacy sources, even in developed countries they can be abandoned, disposed of in a haphazard manner, lost, stolen, and/or otherwise fallout of regulatory control. Supply and demand of sources, being market based, is more or less fluid. Normative security of radioactive sources exists, but varies in each country, and is loosely implemented through non-legally binding recommendations and standards provided by International Atomic Energy Agency technical documents and cooperation and through bilateral efforts such as this workshop where we share best-practices with one another. Much of the reason for the difficulty in securing sealed sources rests in the enormous need for their beneficial applications in the medical, industrial, and agricultural sectors. Alternative technologies to replace high-risk sources continue to be explored, but very few of these alternative solutions have reached the development stage for common usage and distribution. The beneficial uses of sources must be allowed to continue; however, to minimize the potential for their misuse, current controls and regulating mechanisms must be constantly evaluated to ensure the benefits gained outweigh potential risks. From a global perspective, an evaluation and modification of requirements over the entire life cycle of sources from their manufacture to their final disposition is required. The proper removal and disposal of vulnerable disused or orphan sources is essential to maintaining a safe operating environment. One of our goals in this workshop is to share our methodologies for recovering sources and learn how they differ or are similar to the challenges faced in recovering, storing, and disposing of sources in the Republic of Georgia . The suggestions we will make are flexible in allowing for the imperfect situations and capabilities we have all encountered in source recovery efforts. We have designed a table-top exercise specifically to address your concerns about the prevention and mitigation of contaminated facilities, soil, containers, and sources. Our discussion begins with an overview and video of the OSRP along with a brief on our projects ongoing international cooperation and activities. A presentation will be given by the NRSS illustrating the successes and challenges of source management in Georgia. A brief overview will be given of selected significant cases of the intentional misuse of sources. This will be followed by two comprehensive discussions focusing on the decontamination from the facility perspective down to the issues of container and source leakage. The second day will begin with the abovementioned table-top exercise on contamination control. On the third day, a second presentation from the NRSS will open up the session.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Electromagnetic Pain Relief/Blocking: Feasibility Assessment

Context/Background: Astronauts use pharmaceuticals during spaceflight to manage acute and chronic pain, but use of analgesics will have drawbacks for exploration-class missions because the shelf life of these medications is limited, resupply will be curtailed, astronauts may develop tolerance and/or addiction to these medications, and side effects can include impairment of cognitive abilities. Electromagnetic devices have been developed that treat pain terrestrially by affecting neuromodulation–dubbed “electroceuticals”, these devices have varied mechanisms of action that either stimulate or suppress neural activity in the central nervous system or peripheral nerves. Objective/Purpose: The available literature was reviewed and FDA-approved pain treatments (both pharmacological and non-pharmacological), as well as those currently under development, were assessed for their suitability for use in exploration class spaceflight missions. Data Sources: Due to the COVID-19 pandemic and the resulting closure of libraries, data sources were restricted to those available digitally. Online database searches included PubMed, U.S. Patent and Trademark Office, federal grant award databases (National Aeronautics and Space Administration (NASA), Department of Defense (DoD), National Institutes of Health (NIH)), and general internet searches. More than 1,600 records were reviewed in this effort. Study Selection/Eligibility Criteria: Targeted searches included different aspects of pain management. Priority was given to review studies, to cover as much of the available literature as possible in this limited effort. Study Appraisal and Synthesis Methods/Data Extraction and Data Synthesis: The titles of the studies and the awards that were obtained by searching online databases were reviewed and further information was sought for the relevant titles. Abstracts or award summaries were generally available online; for journal abstracts, full text articles were either available online or were requested via interlibrary loan. Results: An overwhelming majority of the literature focuses on the treatment of chronic rather than acute pain because it is assumed that acute pain only rarely fails to resolve and instead transitions into chronic pain when the central nervous system becomes hypersensitized. The available electromagnetic devices marketed for pain treatment have varying levels of invasiveness, use different mechanisms of action, and have demonstrated varying efficacy when evaluated scientifically. A truly noninvasive, highly efficient device is desired for use during spaceflight. One portable, self-contained, FDA-approved device was identified that, from preliminarily assessment, best met these criteria; the device noninvasively applies pulsed shortwave therapy (PSWT) to modify pain signals from peripheral nerves, however, the device has limited battery life and the effects are relatively non-selective in type of neural signal modified. Limitations: This current effort, although extensive, did not identify a comprehensive list of all alternatives for pain treatment. Once the pandemic limitations are lifted, a longer, more thorough effort may find additional options. Conclusions/Implications: The ideal electromagnetic pain treatment device for use on exploration-class spaceflight missions does not yet exist, but it may be available soon. It is not feasible for NASA to develop medical devices due to the schedule constraints for pending exploration-class missions, but adapting a promising device that is already FDA-approved might be an option. Monitoring research that is ongoing at other federal agencies is recommended, and further review of the candidate PSWT device identified in this current effort may be warranted.

Carol Mullenax↗

Electromagnetic Pain Relief/Blocking: Feasibility Assessment

CONTEXT/BACKGROUND Astronauts use pharmaceuticals during spaceflight to manage acute and chronic pain, but use of analgesics will have drawbacks for exploration-class missions because the shelf life of these medications is limited, resupply will be curtailed, astronauts may develop tolerance and/or addiction to these medications, and side effects can include impairment of cognitive abilities. Electromagnetic devices have been developed that treat pain terrestrially by affecting neuromodulation–dubbed “electroceuticals”, these devices have varied mechanisms of action that either stimulate or suppress neural activity in the central nervous system or peripheral nerves. OBJECTIVE/PURPOSE The available literature was reviewed and FDA-approved pain treatments (both pharmacological and non-pharmacological), as well as those currently under development, were assessed for their suitability for use in exploration class spaceflight missions. DATA SOURCES Due to the COVID-19 pandemic and the resulting closure of libraries, data sources were restricted to those available digitally. Online database searches included PubMed, U.S. Patent and Trademark Office, federal grant award databases (National Aeronautics and Space Administration (NASA), Department of Defense (DoD), National Institutes of Health (NIH)), and general internet searches. More than 1,600 records were reviewed in this effort. STUDY SELECTION/ELIGIBILITY CRITERIA Targeted searches included different aspects of pain management. Priority was given to review studies, to cover as much of the available literature as possible in this limited effort. STUDY APPRAISAL AND SYNTHESIS METHODS/DATA EXTRACTION AND DATA SYNTHESIS The titles of the studies and the awards that were obtained by searching online databases were reviewed and further information was sought for the relevant titles. Abstracts or award summaries were generally available online; for journal abstracts, full text articles were either available online or were requested via interlibrary loan. RESULTS An overwhelming majority of the literature focuses on the treatment of chronic rather than acute pain because it is assumed that acute pain only rarely fails to resolve and instead transitions into chronic pain when the central nervous system becomes hypersensitized. The available electromagnetic devices marketed for pain treatment have varying levels of invasiveness, use different mechanisms of action, and have demonstrated varying efficacy when evaluated scientifically. A truly noninvasive, highly efficient device is desired for use during spaceflight. One portable, self-contained, FDA-approved device was identified that, from preliminarily assessment, best met these criteria; the device noninvasively applies pulsed shortwave therapy (PSWT) to modify pain signals from peripheral nerves, however, the device has limited battery life and the effects are relatively non-selective in type of neural signal modified. LIMITATIONS This current effort, although extensive, did not identify a comprehensive list of all alternatives for pain treatment. Once the pandemic limitations are lifted, a longer, more thorough effort may find additional options. CONCLUSIONS/IMPLICATIONS The ideal electromagnetic pain treatment device for use on exploration-class spaceflight missions does not yet exist, but it may be available soon. It is not feasible for NASA to develop medical devices due to the schedule constraints for pending exploration-class missions, but adapting a promising device that is already FDA-approved might be an option. Monitoring research that is ongoing at other federal agencies is recommended, and further review of the candidate PSWT device identified in this current effort may be warranted.

C A Mullenax↗

Cross-cultural comparison of concrete recycling decision-making and implementation in construction industry

Waste management is pressing very hard with alarming signals in construction industry. Concrete waste constituents major proportions of construction and demolition waste of 81% in Australia. To minimize concrete waste generated from construction activities, recycling concrete waste is one of the best methods to conserve the environment. This paper investigates concrete recycling implementation in construction. Japan is a leading country in recycling concrete waste, which has been implementing 98% recycling and using it for structural concrete applications. Hong Kong is developing concrete recycling programs for high-grade applications. Australia is making relatively slow progress in implementing concrete recycling in construction. Therefore, empirical studies in Australia, Hong Kong, and Japan were selected in this paper. A questionnaire survey and structured interviews were conducted. Power spectrum was used for analysis. It was found that 'increasing overall business competitiveness and strategic business opportunities' was considered as the major benefit for concrete recycling from Hong Kong and Japanese respondents, while 'rising concrete recycling awareness such as selecting suitable resources, techniques and training and compliance with regulations' was considered as the major benefit from Australian respondents. However, 'lack of clients' support', 'increase in management cost' and 'increase in documentation workload, such as working documents, procedures and tools' were the major difficulties encountered from Australian, Hong Kong, and Japanese respondents, respectively. To improve the existing implementation, 'inclusion of concrete recycling evaluation in tender appraisal' and 'defining clear legal evaluation of concrete recycling' were major recommendations for Australian and Hong Kong, and Japanese respondents, respectively.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation Analysis of NASA SMAP L3 and L4 and SPoRT-LIS Soil Moisture Data in the United States

Soil moisture has a critical role in the development, frequency and persistence of climatic and hydrologic extremes such as drought, heat wave and flooding events. In situ soil moisture data are uneven and sparse in time and space. This highlights the need to utilize other soil moisture sources to fill this spatiotemporal gap. The goal of this study is to validate one satellite-based and two model-based soil moisture datasets with in situ data across the United States. Soil moisture information from the Soil Moisture Active Passive (SMAP) enhanced level 3 (L3) (SMAP L3) and modeled level 4 (L4) (SMAP L4) data at 9-km resolution and Short-term Prediction Research and Transition-Land Information System (SPoRT-LIS) modeled at 3-km resolution were selected for evaluation. SPoRT-LIS is a near real-time, high resolution operational land analysis data. Ground-based data were obtained from the North American Soil Moisture Database (NASMD) for 362 stations. Seven statistical indicators including anomaly, Spearman, and Pearson correlation coefficients, the systematic error (Bias), root mean square error (RMSE), unbiased root mean square error (ubRMSE), and normalized standard deviation (SDV) were used to evaluate the satellite- and model-derived soil moisture data. In addition, the triple collocation (TC) error model was used to measure the error among SMAP L4, SPoRT-LIS and ground-based data. This study assesses which satellite or modeled dataset is most appropriate for specific times and locations to use as a surrogate for in situ observations. Temporal and spatial analysis demonstrated that, overall, SMAP L4 performed better than SMAP L3 and SPoRT-LIS. Strong agreement was observed between SMAP L4 and in situ observations (ρ = 0.53, Bias = −0.006) in all seasons and most regions with various land covers, especially in winter and in the central regions of the United States. For croplands, SMAP L4 presented the best agreement with in situ data, analyzing all period (ρ = 0.60) and non-winter period (ρ = 0.61) separately.

Tavakol, Ameneh↗

Optimal dimensionality selection for independent component analysis of transcriptomic data

Independent component analysis is an unsupervised machine learning algorithm that separates a set of mixed signals into a set of statistically independent source signals. Applied to high-quality gene expression datasets, independent component analysis effectively reveals both the source signals of the transcriptome as co-regulated gene sets, and the activity levels of the underlying regulators across diverse experimental conditions. Two major variables that affect the final gene sets are the diversity of the expression profiles contained in the underlying data, and the user-defined number of independent components, or dimensionality, to compute. Availability of high-quality transcriptomic datasets has grown exponentially as high-throughput technologies have advanced; however, optimal dimensionality selection remains an open question. We computed independent components across a range of dimensionalities for four gene expression datasets with varying dimensions (both in terms of number of genes and number of samples). We computed the correlation between independent components across different dimensionalities to understand how the overall structure evolves as the number of user-defined components increases. We then measured how well the resulting gene clusters reflected known regulatory mechanisms, and developed a set of metrics to assess the accuracy of the decomposition at a given dimension. We found that over-decomposition results in many independent components dominated by a single gene, whereas under-decomposition results in independent components that poorly capture the known regulatory structure. From these results, we developed a new method, called OptICA, for finding the optimal dimensionality that controls for both over- and under-decomposition. Specifically, OptICA selects the highest dimension that produces a low number of components that are dominated by a single gene. We show that OptICA outperforms two previously proposed methods for selecting the number of independent components across four transcriptomic databases of varying sizes. OptICA avoids both over-decomposition and under-decomposition of transcriptomic datasets resulting in the best representation of the organism’s underlying transcriptional regulatory network.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-C-204-05: Simulations of a Portal Imaging System for Conformal and Intensity Modulated Fast Neutron Therapy

Purpose: The University of Washington Medical Center offers neutron therapy for the palliative and definitive treatment of selected cancers. In vivo field verification has the potential to improve the safe and effective delivery of neutron therapy. We propose a portal imaging method that relies on the creation of positron emitting isotopes (11C and 15O) through (n, 2n) reactions with a PMMA plate placed below the patient. After field delivery, the plate is retrieved from the vault and imaged using a reader that detects annihilation photons. The spatial pattern of activity produced in the PMMA plate provides information to reconstruct the neutron fluence map needed to confirm treatment delivery. Methods: We used MCNP to simulate the accumulation of 11C activity in a slab of PMMA 2 mm thick, and GATE was used to simulate the sensitivity and spatial resolution of a prototype imaging system. BGO crystal thicknesses of 1 cm, 2 cm and 3 cm were simulated with detector separations of 2 cm. Crystal pitches of 2 mm and 4 mm were evaluated. Back-projection of the events was used to create a planar image. The spatial resolution was taken to be the FWHM of the reconstructed point source image. Results: The system sensitivity for a point source in the center of the field of view was found to range from 58% for 1 cm thick BGO with 2 mm crystal pitch to 74% for the 3 cm thick BGO crystals with 4 mm crystal pitch. The spatial resolution at the center of the field of view was found to be 1.5 mm for the system with 2 mm crystal pitch and 2.8 mm for the system with the 4 mm crystal pitch. Conclusion: BGO crystals with 4 mm crystal pitch and 3 cm length would offer the best sensitivity reader.

07 ISOTOPE AND RADIATION SOURCES↗

HydraGNN_Predictive_GFM_2024 - Ensemble of predictive graph foundation models for ground state atomistic materials modeling

We provide the ensemble of fifteen pre-trained graph foundation models (GFMs) for atomistic materials modeling applications. Each one of the fifteen GFMs has been trained on five open-source datasets that (once aggregated) amount to over 154 million atomistic structures, which cover over two-thirds of the natural elements of the periodic table and that comprises a broad set of organic and inorganic compounds. This vast set of atomistic structures comprises ground state configurations that are dynamically stable (i.e., equilibrated structures with atomic forces approximately close to zero values) as well as dynamically unstable structures (i.e., non-equilibrium structures with non-negligible non-zero values of atomic forces). The ensemble of datasets aggregated does NOT include excited states. The datasets have been curated to remove atomistic structures with spectral norm of the force tensor above 100 eV/angstrom. Moreover, a linear term of the energy was computed for each dataset using a linear regression model that uses the chemical concentration of each natural element as regressor. The linear term predicted by the linear regression model has been subtracted from each original energy value to perform a re-alignment of the energy values across different electronic structures approximation theories performed to generate the diverse multi-source, multi-fidelity datasets. The folder "ADIOS_files" contains the set of pre-processed datasets in Adaptable I/O System (ADIOS) format (https://www.exascaleproject.org/research-project/adios/) that have been used for the development and training of GFMs in this work. The "ADIOS_files" directory contains 6 sub-directories named as follows: - ANI1x-v3.bp - MPTrj-v3.bp - OC2020-20M-v3.bp - OC2020-v3.bp - OC2022-v3.bp - qm7x-v3.bp Each sub-directory contains the pre-processed datasets converted in Adaptable I/O System (ADIOS) format (https://www.exascaleproject.org/research-project/adios/) that have been used to the development, training, and performance testing of the ensemble go predictive graph foundation models. Each GFM was developed using HydraGNN (https://github.com/ORNL/HydraGNN) as underlying graph neural network (GNN) architecture. The multi-task learning (MTL) capability of HydraGNN was used to simultaneously train the GFMs on labeled values for direct predictions of energy (a total system property of an atomistic structure that measures the chemical stability) and atomic forces (an atomic level property of an atomistic structure that measures the dynamical stability). The hyper parameters of the GFM have been tuned using scalable hyperparameter optimization (HPO) algorithms implemented in the software DeepHyper (https://github.com/deephyper/deephyper). The pre-training of each HPO trial was performed using distributed data parallelism (DDP) to scale the training across 128 compute nodes of the exascale OLCF supercomputer Frontier. Each HPO trial was trained only for 10 epochs and an early stopping was performed to avoid wasting significant computational resources on GNN architectures that were clearly underperforming. For each HPO trial, the 'omnistat' tool developed by (AMD Research - Advanced Micro Device) was used to measure the total energy consumption in kWh. The ensemble of GFMs was obtained by selecting the fifteen best performing HPO trials. Four models have been selected for their clear advantage in accuracy, and these are the GFMs with IDs 229, 156, 147, 260. Additional eleven models have been selected based on judicious balance between accuracy and energy consumption needed for training, and these are the GFMs with IDs 165, 78, 137, 1, 175, 171, 181, 67, 179, 167, 351. Each selected GFM of the ensemble was continued to cumulate a total of at most 30 epochs. In some cases, the total number of epochs actually performed was les than 30 due to two combined factors: (1) the size of the GFM (i.e., the number of model parameters to train) and (2) the total wall-clock time for which the computational resources could be allocated on OLCF-Frontier. The "Ensemble_of_models" directory contains 15 sub-directories named as follows: - gfm_0.229 - gfm_0.156 - gfm_0.147 - gfm_0.260 - gfm_0.165 - gfm_0.78 - gfm_0.137 - gfm_0.1 - gfm_0.175 - gfm_0.171 - gfm_0.181 - gfm_0.67 - gfm_0.179 - gfm_0.167 - gfm_0.351 Each one of these sub-directories refers to one of the fifteen HPO trials that have been selected to continue the pre-training with at most 30 epochs. With each sub-directory associated with a specific HPO trial, the following files can be found: - config.json: file for argument parsing to develop and train an HydraGNN architecture - gfm_0.ID_epoch_N.pk: file with model parameters for HPO ID trial after N epochs of training The ensemble of fifteen GFM architectures was used for (1) ensemble averaging to stabilize the predictions of energy and atomic forces after pre-training for post-processing analysis and (2) ensemble uncertainty quantification (UQ). The code used to develop, pre-train, and load the pre-trained models for post-processing analysis is available on the ORNL-GitHub at the following link: https://github.com/ORNL/HydraGNN/tree/Predictive_GFM_2024

36 MATERIALS SCIENCE↗