Search NASA⌕ Search

SEARCH · Search NASA

Results for “boundary condition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow $Q^{avg}_{Ao}$, maximum aortic root flow $Q^{max}_{Ao}$, average LVAD flow $Q^{avg}_{VAD}$, and maximum LVAD flow $Q^{max}_{VAD}$; (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive.

59 BASIC BIOLOGICAL SCIENCES↗

Update on the Investigation of Commercial Drying Cycles Using the Advanced Drying Cycle Simulator

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents a new test apparatus, the Advanced Drying Cycle Simulator (ADCS). This apparatus was built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. These waterproof heaters are the next generation design to heater rods developed and tested at Sandia National Laboratories in FY20. This report describes the ADCS vessel build that was completed late in FY22, including the receipt of the prototypic length waterproof heater rods and construction of the fuel basket and the pressure vessel components. In addition, installations of thermocouples, emissivity coupons, pressure and vacuum lines, pressure transducers, and electrical connections were completed. Preliminary power functionality testing was conducted to demonstrate the capabilities of the ADCS. In FY23, a test plan for the ADCS will be developed to implement a drying procedure based on measurements from the process used for the High Burnup Demonstration Project. While applying power to the simulated fuel rods, this procedure is expected to consist of filling the ADCS vessel with water, draining the water with applied pressure and multiple helium blowdowns, evacuating additional water with a vacuum drying sequence at successively lower pressures, and backfilling the vessel with helium. Additional investigations are expected to feature failed fuel rod simulators with engineered cladding defects and guide tubes with obstructed dashpots to challenge the drying system with multiple water retention sites.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Simulations of Commercial Drying Cycles Using the Advanced Drying Cycle Simulator

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents fiscal year 2023 (FY23) updates on the Advanced Drying Cycle Simulator (ADCS). This apparatus was built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. These waterproof heaters are the next generation design to heater rods developed and tested at Sandia National Laboratories in FY20. In FY23, a series of four simulated commercial drying tests was completed. This report presents the temperature and pressure histories of the drying tests as well as axial temperature profiles that can be compared to data from the Electric Power Research Institute (EPRI) High Burnup Demonstration TN-32B cask. Water content measurements and dew point calculations from a Hiden Analytical HPR-30 mass spectrometer are also presented in this report. Due to familiarization with this first-of-a-kind system, refinements to equipment calibration and test procedures have been identified to better match commercial drying cycles for future simulated tests. However, the presented data demonstrate the successful construction and operation of a viable research platform for quantifying residual water content closely approaching that expected in dry storage canisters during commercial drying procedures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling low cycle fatigue (LCF) of additively manufactured Hastelloy X using An accelerated crystal plasticity fatigue damage model

This paper presents a microstructure-based model for low cycle fatigue (LCF) behavior and life of Nickel-based alloy Hastelloy X manufactured using laser-powder bed fusion (L-PBF) additive manufacturing (AM). AM Hastelloy X, a solution-strengthened alloy, is tested at elevated temperature under fully reversed LCF conditions at different strain levels. A generalized plane strain finite element model is generated from electron backscatter diffraction (EBSD) characterization. The constitutive behavior of the material under fatigue is modeled using crystal plasticity and calibrated with both monotonic tensile and cyclic stress–strain data. The fatigue micro-crack initiation and propagation in the microstructure is modeled using a modified Chaboche fatigue damage model. An embedded boundary condition with a homogenous medium is used to apply the cyclic deformation and prevent numerically introduced over-constraints during fatigue simulation. A ‘cycle-jump’ method is used to accelerate the fatigue simulation and reduce the computational cost. The simulation results are compared to LCF experiments, showing satisfactory matches in cyclic stress behavior and number of cycles to macro-crack initiation for all applied strain ranges. In addition, the model illustrates the potential for quantifying microscale fatigue life impacting factors such as microstructure and surface roughness, which is needed to accurately quantify the reliability of AM components in service.

36 MATERIALS SCIENCE↗

Investigation of species-mass diffusion in binary-species boundary layers at high pressure using direct numerical simulations

Here, direct numerical simulations of single-species and binary-species temporal boundary layers at high pressure are performed with special attention to species-mass diffusion. The working fluids are nitrogen or a mixture of nitrogen and methane. Mean profiles and turbulent fluctuations of mass fraction show that their qualitative characteristics are different from those of streamwise velocity and temperature, due to the different boundary conditions. In a wall-parallel plane near the wall, the streamwise velocity and temperature have streaky patterns and the fields are similar. However, the mass fraction field at the same location is different from the streamwise velocity and temperature fields indicating that species-mass diffusion is not similar to the momentum and thermal diffusion. In contrast, at the centre and near the edge of the boundary layer, the mass fraction and temperature fields have almost the same pattern, indicating that the similarity between thermal and species-mass diffusion holds away from the wall. The lack of similarity near the wall is traced to the Soret effect that induces a temperature-gradient-dependent species-mass flux. As a result, a new phenomenon has been identified for a non-isothermal binary-species system – uphill diffusion, which in its classical isothermal definition can only occur for three or more species. A quadrant analysis for the turbulent mass flux reveals that near the wall the Soret effect enhances the negative contributions of the quadrants. Due to the enhancement of the negative contributions, small species-concentration fluid tends to be trapped near the wall.

42 ENGINEERING↗

Tencoder: tensor-product encoder-decoder architecture for predicting solutions of PDEs with variable boundary data

It is widely hoped that artificial intelligence will boost data-driven surrogate models in science and engineering. However, fundamental spatial aspects of AI surrogate models remain under-studied. We investigate the ability of neural-network surrogate models to predict solutions to PDEs under variable boundary values. We do not wish to retrain the model when the boundary values change but to make them inputs to the model and infer the solution of the PDE under those boundary conditions. Such a capability is essential to making AI-based surrogate models practically useful. While simple feedforward networks are used for one-dimensional (1D) Poisson equation, an encoder-decoder architecture with a tensor-product layer is developed for the two-dimensional Poisson equation posed on a rectangular domain. We show that it is indeed possible to infer solutions to PDEs from variable boundary data using neural networks in this relatively simple setting, and point to future directions.

Kashi, Aditya↗

Dynamically Downscaled (WRF) 1km, Hourly Meteorological Conditions 1987-2020. East/Taylor Watersheds

This dataset contains meteorological output from the Weather Research and Forecasting (WRF) version 3.8.1. This dataset has been created to 1) investigate hydrometeorological processes impacting the East River and water-delivery to the Critical Zone, and 2) provide meteorological forcing data for distributed Earth-science modeling applications in the East River watershed. Variables have a 1 kilometer spatial resolution and hourly temporal resolution and encompass a rectangular region encompassing the East and Taylor River watersheds, Colorado, near the town of Crested Butte. WRF was forced using Climate Forecast System Reanalysis (CFSR) lateral boundary conditions. Each .zip file contains one "water year" of data (October 1 -- September 30; i.e. water year 2017 starts October 1, 2016 and ends September 30, 2017). Each zip folder contains 12 netcdf (.nc) files containing one month of hourly data each and are approximately 250mb. Model timestamps are in UTC time.The files contain the following data variables:EAST_MASK: binary mask of the watershed regionTAYLOR_MASK: binary mask of the watershed regionGLW downwelling longwave radiation (w/m2)HR_PRCP: Hourly Precipitation Rate (mm/hr). Includes all hydrometeors (solid+liquid). HFX NoahMP LSM total grid-cell modelled sensible heat flux (w/m2) [positive towards atmosphere]LH NoahMP LSM total grid-cell modelled latent heat flux (w/m2) [positive towards atmosphere; can be converted to ET]PSFC Surface Barometric Pressure (hPa)Q2 Two-meter specific humidity (kg/kg)SWDOWN Downwelling shortwave solar radiation (w/m2)SWNORM Terrain-normal downwelling shortwave radiation (w/m2)T2 Two-meter air temperature (deg K)U10 10-m U-component of wind velocity (m/s)V10 10m V-component of wind velocity (m/s)XLAT Latitude of grid-center point XLONG Longitude of grid-center point XTIME Model timestamp, **in UTC**

54 ENVIRONMENTAL SCIENCES↗

An open source fast fluid dynamics model for data center thermal management

Although computational fluid dynamics (CFD) has been widely adopted to improve data center thermal management, the high computational demand limits its applications, such as multivariate optimal design and operation. Fast fluid dynamics (FFD), which has been applied for fast airflow simulation, shows great potential. However, few research applied FFD for optimal design and operation of data center thermal management. This research improves the FFD model for data centers and conducts a comprehensive evaluation and demonstration. First, the FFD model is improved by solving the advection and diffusion equations together using an upwind scheme instead of a semi-Lagrangian advection solver in the conventional FFD model. Second, new features for data centers are added, such as a pressure correction method to simulate plenum airflow and dynamic boundary conditions for IT racks. The new FFD model is first validated with two indoor environment cases and the results show that the new FFD model has slightly better overall prediction accuracy and faster speed compared to the conventional FFD model. It is also observed that both FFD models achieve acceptable accuracy, except for a few localized disparities with experimental data, which might be due to simplified handling of turbulence viscosity near the boundaries. Furthermore, validation with a real data center shows that the FFD model achieves a similar level of accuracy as CFD when compared to the experimental measurements with some level of uncertainties. It is then demonstrated for data center optimal design and operation, which saves 53.4–58.8% of annual energy while still meeting the thermal requirements. In conclusion, with a much faster speed and comparable accuracy compared to CFD, the FFD model parallelized on a graphics processing unit is promising for practical model-based data center early design and operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A non-intrusive framework using acoustic signals and deep learning for boiling diagnostics in visual-limited environments

Accurate monitoring of boiling heat transfer is critical for safeguarding high-power systems operating in environments where conventional optical diagnostics are hindered by radiation fields or restricted visual accessibility. This study presents a non-intrusive framework that integrates hydroacoustic sensing with deep learning to infer near-wall boiling characteristics and enable predictive thermal assessment without visual access. In a prototypical subcooled flow-boiling facility representative of the Isotope Production Facility (IPF) at Los Alamos, hydrophones capture boiling-induced acoustic emissions that are transformed into background-removed Short-Time Fourier Transform (STFT) spectrograms. A convolutional neural network (CNN) then regresses heat flux, wall superheat, and key bubble parameters directly from these spectrograms. The CNN achieved predictive accuracy under nominal conditions and demonstrated robustness and generalization under acoustic noise for Signal-to-Noise Ratios (SNRs) down to approximately 0 dB. When integrated into an ANSYS CFX wall-boiling model, the acoustically inferred parameters reproduced boiling curve and critical heat flux (CHF) values consistent with image-based benchmarks. Furthermore, the model retained reliable performance under moderate variations in bulk temperature, flow rate, and hydrophone placement, confirming its generalizability across practical boundary conditions. These results demonstrate the feasibility of hydroacoustic-based deep learning as a viable path toward real-time, radiation-tolerant boiling diagnostics and predictive thermal safety assessment in inaccessible systems such as the IPF.

42 ENGINEERING↗

Investigating the Causes and Impacts of Convective Aggregation in a High Resolution Atmospheric GCM

Abstract A ∼50 km resolution atmospheric general circulation model (GCM) is used to investigate the impact of radiative interactions on spatial organization of convection, the model's mean state, and extreme precipitation events in the presence of realistic boundary conditions. Mechanism‐denial experiments are performed in which synoptic‐scale feedbacks between radiation and dynamics are suppressed by overwriting the model‐generated atmospheric radiative cooling rates with its monthly varying climatological values. When synoptic‐scale radiative interactions are disabled, the annual mean circulation and precipitation remain almost unchanged, however tropical convection becomes less aggregated, with an increase in cloud fraction and relative humidity in the free troposphere but a decrease in both variables in the boundary layer. Changes in cloud fraction and relative humidity in the boundary layer exhibit more sensitivity to the presence of radiative interactions than variations in the degree of aggregation. The less aggregated state is associated with a decrease in the frequency of extreme precipitation events, coincident with a decrease in the dynamical contribution to the magnitude of extreme precipitation. At regional scales, the spatial contrast in radiative cooling between dry and moist regions diminishes when radiative interactions are suppressed, reducing the upgradient transport of energy, degree of aggregation, and frequency of extreme precipitation events. However, the mean width of the tropical rain belt remains almost unaffected when radiative interactions are disabled. These results offer insights into how radiation‐circulation coupling affects the spatial organization of convection, distributions of clouds and humidity, and weather extremes.

54 ENVIRONMENTAL SCIENCES↗

Plasma radiation behavior approaching high-radiation scenarios in W7-X

The W7-X stellarator has so far performed experiments under both limiter and divertor conditions. The plasma is mostly generated by ECR-heating with powers up to 6.5 MW, and the plasma density is usually limited by the radiation losses from low-Z impurities (such as carbon and oxygen) released mainly from the graphite targets. The present work first summarizes the radiation loss fractions f rad achieved in quasi-stationary hydrogen plasmas in both operational phases, and then shows how impurity radiation behaves differently with the two different boundary conditions as the plasma density increases. The divertor operation is emphasized and some beneficial effects (with respect to impurity radiation) are highlighted: (1) intensive radiation is located at the edge (r/a > 0.8) even at high radiation loss fractions, (2) the plasma remains stable up to f rad approaching unity, (3) the reduction in the stored energy is about 10% for high f rad scenarios. Moreover, effects of wall boronisation on impurity radiation profiles are also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

$2+1$ dimensional Floquet systems and lattice fermions: Exact bulk spectral equivalence

A connection has recently been proposed between periodically driven systems known as Floquet insulators in continuous time and static fermion theories in discrete time. This connection has been established in a (1+1) ( 1 + 1 ) -dimensional free theory, where an explicit mapping between the spectra of a Floquet insulator and a discrete-time Dirac fermion theory has been formulated. Here we investigate the potential of static discrete-time theories to capture Floquet physics in higher dimensions, where so-called anomalous Floquet topological insulators can emerge that feature chiral edge states despite having bulk bands with zero Chern number. Starting from a particular model of an anomalous Floquet system, we provide an example of a static discrete-time theory whose bulk spectrum is an exact analytic match for the Floquet spectrum. The spectra with open boundary conditions in a particular strip geometry also match up to finite-size corrections. However, the models differ in several important respects. The discrete-time theory is spatially anisotropic, so that the spectra do not agree for all lattice terminations, e.g. other strip geometries or on half spaces. This difference can be attributed to the fact that the static discrete-time model is quasi-one-dimensional in nature and therefore has a different bulk-boundary correspondence than the Floquet model.

Iadecola, Thomas (ORCID:0000000251456441)↗

Laboratory evaluation of cyclic underground hydrogen storage in the Temblor sandstone of the San Joaquin Basin, California

Underground Hydrogen Storage (UHS) in depleted oil and gas reservoirs could provide a cost-effective solution to balance seasonal fluctuations in renewable energy generation. However, data and knowledge on UHS at subsurface conditions are limited so it is difficult to estimate how effective this type of storage could be. In this study, we perform high pressure experiment to measure the effectiveness of cyclic hydrogen (H 2 ) storage in a specimen of Temblor sandstone retrieved from the San Joaquin Basin of California. Our experiment mimics reservoir pressure conditions to measure H 2 -brine relative permeability and fluid-rock interactions over the course of ten charging and discharging cycles. Initial gas breakthrough occurred at 15 % to 25 % H2 saturation in the specimen with 3 % NaCl brine as the resident fluid. Continuing injecting to 4 pore volumes (PV) of H 2 yielded an asymptotic H 2 saturation of 38 % to 41 %, a level often referred to as the irreducible gas saturation based on two-phase flow. The boundary condition in this study mimics the near wellbore region, which experiences bi-directional H 2 flow. This bi-directional flow led to evaporative drying of the specimen resulting in 94 % H 2 saturation at the end of 10th cycle. This indicates that cyclic flow and evaporative drying can lead to more efficient reservoir storage where a larger fraction of the reservoir porosity is usable to store H 2 . The produced gas stream consisted of H 2 mixed with 8 % to 22 % H 2 O, indicating formation dry-out by evaporation. Meanwhile, produced water chemistry indicated calcite and silicate dissolution, with calcite sourced from fossil fragments. This led to a loss of cementation and weakened the rock sample. Combined, our results indicate dry-out, compaction, increased H 2 saturation, rock weakening, and permeability loss during cyclic UHS. Overall, we anticipate that the combined effects should lead to higher than anticipated UHS storage efficiency per volume of sandstone reservoir rock.

08 HYDROGEN↗

Quantification of Residual Water in Spent Fuel Dry Storage Canisters Using Mass Spectrometry

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal, such as fuel degradation; cladding corrosion, embrittlement, or breaching; and the creation of a flammable environment via radiolysis of water. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents details on the quantification of residual water in the Advanced Drying Cycle Simulator (ADCS), an apparatus built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. The ADCS is outfitted with thermocouples to measure the thermal response of the ADCS to simulated decay heats and internal helium fill pressures relevant to commercial drying procedures. The ADCS is also instrumented with pressure transducers to measure the pressures and vacuum levels observed during simulated commercial drying. The most unique instrumentation used for quantifying residual water in the ADCS is a Hiden Analytical HPR-30 mass spectrometer (MS), which measures gas compositions of the ADCS internal free volume, based on partial pressures calculated from relative proportions of gas molecules detected by the MS. This report details the methodology used to implement MS measurements in quantifying residual water in the ADCS. This methodology includes the calibration of the HPR-30 MS to a Buck Research Instruments CR-4 chilled mirror hygrometer, which itself is calibrated to a NIST-traceable standard. Data collected by both the MS and the chilled mirror hygrometer from water/helium mixtures ranging from 150 to 500,000 ppmv water in helium were used to generate calibration curves, establishing a source of verification of MS measured water contents. Details regarding water content measurement uncertainties are included in this report, defining the accuracy and verifiability of the HPR-30 MS in measuring residual water content in simulated dry storage canister environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermomechanical Stress and Creep-Fatigue Analysis of a High-Temperature Prototype Receiver for Heating Particles

This work presents a three-dimensional (3D) thermomechanical model of a prototype-scale enclosed light trapping solar receiver for heating particles. Results of the thermoelastic model are used to estimate receiver lifetime under maximum flux conditions. A computational fluid dynamics (CFD) model is first developed to predict the temperature fields in a multi-panel assembly under steady operating conditions. Solar flux distributions on the receiver are obtained from the software package SolTrace and applied to the 3D thermal model. The subsequent particle heating is captured through a simplified 1D energy balance. Panel reradiation is considered through a surface-to-surface radiation model and natural convection loss to the surrounding air is captured in a representative fluid domain surrounding the receiver. The resulting temperature fields from the CFD analysis are used as inputs for a thermoelastic mechanical model with representative boundary conditions. With the resultant temperature and stress fields, a creep-fatigue damage and lifetime analysis is performed using the linear damage accumulation (LDA) theory. The Manson-Coffin formula and Larson Miller correlation are used to calculate the fatigue and creep, respectively. A maximum damage (corresponding to a 30-year service life) is defined for design assessment. The model was first developed and verified in detail by comparing with published results in the literature (temperature and stress profiles and distributions, and creep/fatigue damage fractions) for tubular solar receivers with supercritical carbon dioxide as the working fluid. It was then implemented to model a planar-cavity receiver with various design parameters. Specifically, three different design geometries are considered, and the results show that a maximum temperature of approximately 1200 K could be reached for each design with the given incident solar flux, with the main difference being the distribution of these temperatures. Preliminary resulting stresses for the small-scale prototype without design optimization vary from 20 MPa to 250 MPa for each design, with the maximum stresses occurring on the front face and concave geometry on the side of the panel. In future work, the developed methodology shown here will be applied to analyze a full-scale (50-150 MWth) receiver.

concentrated solar power↗

CFD modeling of natural circulation in LiCl-KCl molten salt closed loop

Characterizing flow within a molten salt closed-loop system is crucial for assessing system requirements, evaluating performance, and identifying potential flaws. Direct flow measurement using instrumentation is challenging due to extreme environmental conditions and the limitations associated with measuring molten salt flow under natural convection. Here, this study aims to provide comprehensive insights into the thermal-hydraulic behavior of a closed loop, with a particular focus on temperature distribution and velocity prediction. The Computational Fluid Dynamics (CFD) model demonstrated the capability to effectively simulate and predict both temperature distributions and flow velocities within the molten salt loop. The CFD model's predictive capability was validated by its ability to replicate temperature measurements under varying boundary conditions. The analysis revealed that the CFD model tends to underpredict temperatures in the cold leg and overpredict them in the hot leg, highlighting the need for continuous model refinement and acknowledging the limitations of using a steady-state approach. Furthermore, the potential of using external temperature measurements to estimate internal molten salt temperatures and predict flow velocity was explored, revealing that this approach could introduce up to a 5.5% error in flow velocity calculations. Line probes mapping temperature distributions across the tube's cross-section and molten salt provided valuable insights into temperature gradients, emphasizing the need for a thermal conductivity equation for molten salt with lower uncertainty to achieve more accurate temperature predictions of the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Computational fluid dynamic modeling to determine the indoor environment of an electron-ion collider service building

The design for the Electron-Ion Collider (EIC) calls for several service buildings that house various power supplies and control electronics for the collider ring itself. In order to operate within specified conditions, the ambient air entering the power supplies needs to be within a certain temperature range while dissipating the heat from losses. Proper cooling is therefore a necessity in the service buildings to ensure that every aspect of the EIC works as intended. Since the EIC is in the design stage, we are evaluating the indoor environment of the service building using the current design specifications. We have researched multiple forms of literature and performed the necessary calculations to compile a list of boundary conditions that accurately represent the situation at hand. We are using computational fluid dynamics modeling to solve the conservation equations for mass, momentum, and energy (Navier-Stokes). This allows us to perform a finite element analysis which will give us the flow distribution in the room as well as temperature profiles throughout the building. We have obtained a simulation result giving us the temperature profiles for the building and it shows that the placement of the racks and supply vents are essential to obtaining an even temperature distribution. This model will provide a basis for design decisions which will affect the overall cooling of the service building without extending the schedule and avoiding a costly reworking of the cooling system.

43 PARTICLE ACCELERATORS↗

Modeling Efforts to Gain Insight into Historical Leak Events from the Single-Shell Tank A-105 in the Hanford 241-A Tank Farm - 20113

The 241-A Tank Farm is a single-shell tank (SST) farm constructed to store process waste from Hanford nuclear operations. Millions of gallons of nuclear waste were stored in the 241-A Tank Farm SSTs and some of the SSTs leaked in the past. In addition, spills and pipeline leaks during transfers and storage and intentional discharges to cribs and trenches resulted in releasing waste to the ground. Tank liner leaks are referred to as 'leaks' and all other discharges to the soil are referred to as 'releases.' Liquid waste that could be removed by pumping has been removed from all of the SSTs to reduce the potential for future leaks. The most significant historical leak event in 241-A Tank Farm occurred in 1965 when tank A-105 experienced a pressurized steam event. This event resulted in damage to the inner steel liner flooring of A-105, which was separated from the sidewalls over part of its circumference and buckled up to 2.5 m, vertically. During this event up to 7,570 L of contaminated liquid may have leaked to the adjacent soil. This leak occurred under extreme temperature and pressure conditions. Modeling efforts to better understand the nature and extent of historical leaks from subsurface SSTs that were used to store highly radioactive, self-boiling liquid wastes at 241-A Tank Farm have recently been undertaken. These efforts have compiled the available historical information to support a preliminary non-isothermal, multiphase flow and chemical transport modeling effort to re-create the conditions under which the leaks occurred and to formulate a conceptual model as to the extent and distribution of leaked radioactive contaminants in the adjacent soil material. The focus of this work was on developing an understanding of the key features, processes and bounding conditions related to tank A-105 leak events that occurred in the 1960's. The activities include estimation of leak composition, non-isothermal multiphase flow and transport modeling, and geochemical modeling. The STOMP{sup C} Water-Air-Energy modeling code was utilized to implement the three-dimensional representation of the subsurface tank and the surrounding flow field. Once constructed, the model was used to evaluate the conceptual understanding of leaks originating from different parts of the tank under the elevated temperature boundary conditions that were imposed by surrounding tanks at the time of the historical leaks. The chemical evolution of the liquid waste was also evaluated as it leaked from the tank under transient pressure and temperature gradients. The results of the preliminary evaluation suggested the presence of a heat-pipe effect beneath tank A-105 in which water vapor at an elevated temperature is driven away from the base of the tank to a position where water vapor cools, condenses and is then drawn back toward the tank by the strong capillary attraction of the dry soil. A non-sorbing contaminant (Tc-99) was introduced into this flow field to better understand the potential distribution patterns of leaked contaminants that may have occurred during the historical leak events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗