Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherent diffraction imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Asymmetric nanoparticle oxidation observed in-situ by the evolution of diffraction contrast

Abstract The use of transmission electron microscopy (TEM) to observe real-time structural and compositional changes has proven to be a valuable tool for understanding the dynamic behavior of nanomaterials. However, identifying the nanoparticles of interest typically require an obvious change in position, size, or structure, as compositional changes may not be noticeable during the experiment. Oxidation or reduction can often result in subtle volume changes only, so elucidating mechanisms in real-time requires atomic-scale resolution or in-situ electron energy loss spectroscopy, which may not be widely accessible. Here, by monitoring the evolution of diffraction contrast, we can observe both structural and compositional changes in iron oxide nanoparticles, specifically the oxidation from a wüstite-magnetite (FeO@Fe 3 O 4 ) core – shell nanoparticle to single crystalline magnetite, Fe 3 O 4 nanoparticle. The in-situ TEM images reveal a distinctive light and dark contrast known as the ‘Ashby-Brown contrast’, which is a result of coherent strain across the core – shell interface. As the nanoparticles fully oxidize to Fe 3 O 4 , the diffraction contrast evolves and then disappears completely, which is then confirmed by modeling and simulation of TEM images. This represents a new, simplified approach to tracking the oxidation or reduction mechanisms of nanoparticles using in-situ TEM experiments.

36 MATERIALS SCIENCE↗

Sub-pixel high-resolution imaging of high-energy x-rays inspired by sub-wavelength optical imaging

We have developed and demonstrated an image super-resolution method—XR-UNLOC: X-Ray UNsupervised particle LOCalization—for hard x-rays measured with fast-frame-rate detectors that is an adaptation of the principle of photo-activated localization microscopy (PALM) and stochastic optical reconstruction microscopy (STORM), which enabled biological fluorescence imaging at sub-optical-wavelength scales. We demonstrate the approach on experimental coherent Bragg diffraction data measured with 52 keV x-rays from a nanocrystalline sample. From this sample, we resolve the fine fringe detail of a high-energy x-ray Bragg coherent diffraction pattern to an upsampling factor of 16 of the native pixel pitch of 30 μ m of a charge-integrating fastCCD detector. This was accomplished by analysis of individual photon locations in a series of “nearly-dark” instances of the diffraction pattern that each contain only a handful of photons. Central to our approach was the adaptation of the UNLOC photon fitting routine for PALM/STORM to the hard x-ray regime to handle much smaller point spread functions, which required a different statistical test for photon detection and for sub-pixel localization. A comparison to a photon-localization strategy used in the x-ray community (“droplet analysis”) showed that XR-UNLOC provides significant improvement in super-resolution. We also developed a metric by which to estimate the limit of reliable upsampling with XR-UNLOC under a given set of experimental conditions in terms of the signal-to-noise ratio of a photon detection event and the size of the point spread function for guiding future x-ray experiments in many disciplines where detector pixelation limits must be overcome.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microstructural features and domain formation in (Ba,Sr){sub 2}TiSi{sub 2}O{sub 8} fresnoites

The formation and co-existence of crystallographically modulated and non-modulated regions in (Ba,Sr){sub 2}TiSi{sub 2}O{sub 8} fresnoites is reviewed, particularly the dependence on local composition. It is shown that perturbations of the average fresnoite structure, determined from appreciable single crystals, are in some cases better described as nanometric domain intergrowths where departures from ideal stoichiometry are characteristics of incommensuration, while modulation is absent from volumes that are less perturbed chemically. Evidence for this differentiation is obtained from selected area electron diffraction (SAED) patterns and high-resolution transmission electron microscopy (HRTEM) images. The domains are readily distinguished by their unique contrast in bright field electron micrographs. Fourier reconstructions of HRTEM images collected from areas with darker contrast show that modulation can change within relatively small volumes. Nearby areas with lighter contrast were found by SAED to be free of structural disorder and incommensurate reflections. - Graphical abstract: Fresnoite layers contain SiO{sub 4} and TiO{sub 5} polyhedra that undergo run rotation and tilting to create 3D, 4D and 5D structural modulations that can be directly observed by electron diffraction and high resolution imaging. Highlights: {yields}(Ba,Sr){sub 2}TiSi{sub 2}O{sub 8} fresnoites contain commensurate and incommensurate domains. > Departures in stoichiometry promote the formation of nanostructured domains. > Domains formation may provide a means for reducing strain in single crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diffraction enhanced imaging utilizing a laser produced x-ray source

Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ~2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm 2 and 2 × 40 μm 2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.

3D printing↗

The PICASSO digital detector for Diffraction Enhanced Imaging at ELETTRA

A clinical mammography program is in progress at the medical beamline SYRMEP of the Italian synchrotron radiation laboratory ELETTRA in Trieste. A conventional screen-film system is utilized as detector for the examinations on patients. For the next experimental step a digital detector has been designed taking into account the essential requirements for mammography such as high spatial and contrast resolution, high efficiency for low dose examinations and high speed for short acquisition time. A double-layer prototype has already been tested in the frame of the PICASSO project. In addition, an analyzer crystal set-up for Diffraction Enhanced Imaging (DEI) has been available for many years at the SYRMEP beamline. Applying the DEI technique several successful experiments have been carried out in biomedical imaging and in particular in-vitro breast imaging utilizing commercially available detectors. Recently a system upgrade yielded a double-crystal analyzer set-up with improved stability and higher angular resolution. In this study the PICASSO detector has been utilized in combination with the new analyzer set-up for imaging in-vitro breast tissue samples. In order to test the potential of the combined system planar and tomographic images have been acquired and the first results are here presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrastable cathodes enabled by compositional and structural dual-gradient design

Cathodes for next-generation batteries are pressed for higher voltage operation (≥4.5 V) to achieve high capacity with long cyclability and thermal tolerance. Current cathodes fail to meet these requirements owing to structural and electrochemical strains at high voltages, leading to fast capacity fading. Here, in this work, we present a cathode with a coherent architecture ranging from ordered to disordered frameworks with concentration gradient and controllable Ni oxidation activities, which can overcome voltage ceilings imposed by existing cathodes. This design enables simultaneous high-capacity and high-voltage operation at 4.5 V without capacity fading, and up to 4.7 V with negligible capacity decay. Multiscale diffraction and imaging techniques reveal the disordered surface is electrochemically and structurally indestructible, preventing surface parasitic reactions and phase transitions. Structural coherence from ordering to disordering limits lattice parameter changes, mitigating lattice strain and enhancing morphological integrity. The dual-gradient design also notably improves thermal stability, driving the advancement of high-performance cathode materials.

36 MATERIALS SCIENCE↗

Electric Field Reconstruction in the Image Plane of a High-Contrast Coronagraph Using a Set of Pinholes around the Lyot Plane

In a setup similar to the self coherent camera, we have added a set of pinholes in the diffraction ring of the Lyot plane in a high-contrast stellar Lyot coronagraph. We describe a novel complex electric field reconstruction from image plane intensity measurements consisting of light in the coronagraph's dark hole interfering with light from the pinholes. The image plane field is modified by letting light through one pinhole at a time. In addition to estimation of the field at the science camera, this method allows for self-calibration of the probes by letting light through the pinholes in various permutations while blocking the main Lyot opening. We present results of estimation and calibration from the High Contrast Imaging Testbed along with a comparison to the pair-wise deformable mirror diversity based estimation technique. Tests are carried out in narrow-band light and over a composite 10% bandpass.

coronagraphs↗

Bragg projection ptychography on niobium phase domain

Here, we demonstrate that the highly sensitive phase-contrast properties of Bragg coherent diffraction measurements combined with the translational diversity of ptychography can provide a Bragg “dark field” imaging method capable of revealing the finger print of domain structure in metallic thin films. Experimental diffraction data was taken from a epitaxially grown niobium metallic thin film on sapphire; and analyzed with the help of a careful combination of implemented refinement mechanisms.

36 MATERIALS SCIENCE↗

Diffraction and coherence in breast ultrasound tomography: a study with a toroidal array

Ultrasound is commonly used as an adjunct to mammography for diagnostic evaluation of suspicions arising from breast cancer screening. As an alternative to conventional sonography that uses hand-held transducers, toroidal array probes that encircle the breast immersed in a water bath have been investigated for ultrasound tomography. In this paper, two sets of experiments performed with a prototype ultrasound scanner on a phantom and a human breast in vivo are used to investigate the effects of diffraction and coherence in ultrasound tomography. Reconstructions obtained with transmission diffraction tomography (TDT) are compared with conventional reflection imaging and computerized ultrasound tomography showing a substantial improvement. The in vivo tests demonstrate that TDT can image the complex boundary of a cancer mass and suggest that it can reveal the anatomy of milk ducts and Cooper's ligaments.

60 APPLIED LIFE SCIENCES↗

Distribution of unresolvable anisotropic microstructures revealed in visibility-contrast images using x-ray Talbot interferometry

X-ray Talbot interferometry has been widely used as a technique for x-ray phase imaging and tomography. We propose a method using this interferometry for mapping distribution of parameters characterizing anisotropic microstructures, which are typically of the order of {mu}m in size and cannot be resolved by the imaging system, in a sample. The method uses reduction in fringe visibility, which is caused by such unresolvable microstructures, in moire images obtained using an interferometer. We applied the method to a chloroprene rubber sponge sample, which exhibited uniaxial anisotropy of reduced visibility. We measured the dependencies of reduced visibility on both the Talbot order and the orientation of the sample and obtained maps of three parameters and their anisotropies that characterize the unresolvable anisotropic microstructures in the sample. The maps indicated that the anisotropy of the sample's visibility contrast mainly originated from the anisotropy of the microstructure elements' average size. Our method directly provides structural information on unresolvable microstructures in real space, which is only accessible through the ultra-small-angle x-ray scattering measurements in reciprocal space, and is expected to be broadly applied to material, biological, and medical sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-space observation of fluctuating antiferromagnetic domains

Magnetic domains play a fundamental role in physics of magnetism and its technological applications. Dynamics of antiferromagnetic domains is poorly understood, although antiferromagnets are expected to be extensively used in future electronic devices wherein it determines the stability and operational speed. Dynamics of antiferromagnets also features prominently in the studies of topological quantum matter. Real-space imaging of fluctuating antiferromagnetic domains is therefore highly desired but has never been demonstrated. We use coherent x-ray diffraction to obtain videos of fluctuating micrometer-scale antiferromagnetic domains in Ni 2 MnTeO 6 on time scales from 10 -1 to 10 3 s. In the collinear phase, thermally activated domain wall motion is observed in the vicinity of the Néel temperature. Unexpectedly, the fluctuations persist through the full range of the higher-temperature helical phase. These observations illustrate the high potential significance of the dynamic domain imaging in phase transition studies and in magnetic device research.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Noise diffraction patterns eliminated in coherent optical systems

Lens rotation technique of noise diffraction pattern elimination spreads diffracted energy, normally concentrated over small area of image, over much larger annular area. Technique advantages include simplified lens selecting process, reduced clean room requirements, and low cost equipment requirements.

Grebowsky, G. R.↗

Two-Dimensional Imaging of Gauge Fields in Optical Lattices

We propose a scheme to generate an arbitrary Abelian vector potential for atoms trapped in a two-dimensional optical lattice. By making the optical lattice potential dependent on the atomic state, we transform the problem into that of a two-dimensional imaging. It is shown that an arbitrarily fine pattern of the gauge field in the lattice can be realized without need of diffraction-limited imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Normalized Noise Power Spectrum of Full Field Digital Mammography System

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sacrificial Tamper Slows Down Sample Explosion in FLASH Diffraction Experiments

Intense and ultrashort x-ray pulses from free-electron lasers open up the possibility for near-atomic resolution imaging without the need for crystallization. Such experiments require high photon fluences and pulses shorter than the time to destroy the sample. We describe results with a new femtosecond pump-probe diffraction technique employing coherent 0.1 keV x rays from the FLASH soft x-ray free-electron laser. We show that the lifetime of a nanostructured sample can be extended to several picoseconds by a tamper layer to dampen and quench the sample explosion, making <1 nm resolution imaging feasible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-Contrast Imaging of Nanostructures with Incoherent Femtosecond Laser Driven Soft X-Ray Source

Application of polychromatic (1.5-15 nm) soft X-ray emission of a spatially large (>0.1 mm) bright femtosecond laser driven plasma source for propagation based phase contrast imaging of nanometer thick foils and biological samples is considered. Diffraction and phase contrast effects increased quality and contrast of the experimental images, registered by LiF crystal X-ray detector with submicron resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗