Search NASA⌕ Search

SEARCH · Search NASA

Results for “comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A comparison of the velocity parameters of SiO V = 1, J = 1 − 0, and J = 2 − 1 maser emission in semiregular variables

We have determined and compared the SiO maser velocity parameters of semiregular variables in the v = 1, J = 1 − 0 (J10{sup 1}) and the v = 1, J = 2 − 1 (J21) transitions. Fourteen sources in the Mopra SiO Maser Catalogue are classified as semiregular variables of types SR, SRa, SRb, or SRc. (L2 Puppis, an SRa star with an unusual SiO maser spectrum, has been analyzed individually.) We have previously presented the overall and phase dependent velocity parameters of SiO masers associated with long period variables (LPVs) of well-established periods and maxima. A comparison of the velocity centroid (VC) difference, VC21–VC10, shows mixed results for the variable types. Some differences are negative and some positive. The SRc difference is negative, large, and relatively stable. The SRb difference has the widest distribution. The velocity ranges (VRs) of the maser emission have been compared using arithmetic averages, Gaussian fits to the distributions, and Weibull fits to the distributions. For LPVs, SRs, SRas, and SRcs the VR10 is one to a few km s{sup −1} greater than the VR21. SRcs have the largest VRs by a factor of two or three indicating the greater range over which the conditions necessary for masers to originate exist in these supergiant stars. SRbs are the only classification of semiregular variable in which the VR21 exceeds the VR10. The larger VR21 compared to VR10 for SRbs appears in all comparisons. The difference in the SRb SiO maser velocity parameters may be due to a difference in the oscillation mechanism of the star. The suggested overtone oscillations of SRbs may affect the circumstellar cloud dynamics. Little theoretical work has specifically addressed the masers in semiregular variables. Qualitative comparisons of the data with the existing models of the SiO masers in LPVs are made.

79 ASTRONOMY AND ASTROPHYSICS↗

VALIDATION OF OBSERVATIONS OBTAINED WITH A LIQUID MIRROR TELESCOPE BY COMPARISON WITH SLOAN DIGITAL SKY SURVEY OBSERVATIONS

The results of a search for peculiar astronomical objects using very low resolution spectra obtained with the NASA Orbital Debris Observatory (NODO) 3 m diameter liquid mirror telescope (LMT) are compared with results of spectra obtained with the Sloan Digital Sky Survey (SDSS). The main purpose of this comparison is to verify whether observations taken with this novel type of telescope are reliable. This comparison is important because LMTs are an inexpensive novel type of telescope that is very useful for astronomical surveys, particularly surveys in the time domain, and validation of the data taken with an LMT by comparison with data from a classical telescope will validate their reliability. We start from a published data analysis that classified as peculiar only 206 of the 18,000 astronomical objects observed with the NODO LMT. A total of 29 of these 206 objects were found in the SDSS. The reliability of the NODO data can be seen through the results of the detailed analysis that, in practice, incorrectly identified less than 0.3% of the 18,000 spectra as peculiar objects, most likely because they are variable stars. We conclude that the LMT gave reliable observations, comparable to those that would have been obtained with a telescope using a glass mirror.

79 ASTRONOMY AND ASTROPHYSICS↗

FAR-ULTRAVIOLET SPECTRAL IMAGES OF THE VELA SUPERNOVA REMNANT: SUPPLEMENTS AND COMPARISONS WITH OTHER WAVELENGTH IMAGES

We present the improved far-ultraviolet (FUV) emission-line images of the entire Vela supernova remnant (SNR) using newly processed Spectroscopy of Plasma Evolution from Astrophysical Radiation/Far-Ultraviolet Imaging Spectrograph (SPEAR/FIMS) data. The incomplete C III {lambda}977 and O VI {lambda}{lambda}1032, 1038 images presented in the previous study are updated to cover the whole region. The C IV {lambda}{lambda}1548, 1551 image with a higher resolution and new images at Si IV {lambda}{lambda}1394, 1403, O IV] {lambda}1404, He II {lambda}1640.5, and O III] {lambda}{lambda}1661, 1666 are also shown. Comparison of emission-line ratios for two enhanced FUV regions reveals that the FUV emissions of the east-enhanced FUV region may be affected by nonradiative shocks of another very young SNR, the Vela Jr. SNR (RX J0852.0-4622, G266.6-1.2). This result is the first FUV detection that is likely associated with the Vela Jr. SNR, supporting previous arguments that the Vela Jr. SNR is close to us. The comparison of the improved FUV images with soft X-ray images shows that an FUV filamentary feature forms the boundary of the northeast-southwest asymmetrical sections of the X-ray shell. The southwest FUV features are characterized as the region where the Vela SNR is interacting with slightly denser ambient medium within the dim X-ray southwest section. From a comparison with the H{alpha} image, we identify a ring-like H{alpha} feature overlapped with an extended hot X-ray feature of similar size and two local peaks of C IV emission. Their morphologies are expected when the H{alpha} ring is in direct contact with the near or far side of the Vela SNR.

79 ASTRONOMY AND ASTROPHYSICS↗

Kinetic simulation of a low-pressure helium discharge with comparison to experimental measurements

Modern computational validation efforts rely on comparison of known experimental quantities such as current, voltage, particle densities, and other plasma properties with the same values determined through simulation. A discrete photon approach for radiation transport was recently incorporated into a particle-in-cell/direct simulation Monte Carlo code. As a result, spatially and temporally resolved synthetic spectra may be generated even for non-equilibrium plasmas. The generation of this synthetic spectra lends itself to potentially new validation opportunities. In this work, initial comparisons of synthetic spectra are made with experimentally gathered optical emission spectroscopy. A custom test apparatus was constructed that contains a 0.5 cm gap distance parallel plane discharge in ultra high purity helium gas (99.9999%) at a pressure of 75 Torr. Plasma generation is initiated with the application of a fast rise-time, 100 ns full-width half maximum, 2.0 kV voltage pulse. Transient electrical diagnostics are captured along with time-resolved emission spectra. A one-dimensional simulation is run under the same conditions and compared against the experiment to determine if sufficient physics are included to model the discharge. To sync the current measurements from experiment and simulation, significant effort was undertaken to understand the kinetic scheme required to reproduce the observed features. Additionally, the role of the helium molecule excimer emission and atomic helium resonance emission on photocurrent from the cathode are studied to understand which effect dominates photo-feedback processes. Results indicate that during discharge development, atomic helium resonance emission dominates the photo-flux at the cathode even though it is strongly self-absorbed. A comparison between the experiment and simulation demonstrates that the simulation reproduces observed features in the experimental discharge current waveform. Here, the synthesized spectra from the kinetic method produces more favorable agreement with the experimental data than a simple local thermodynamic equilibrium calculation and is a first step towards using spectra generated from a kinetic method in validation procedures. The results of this study produced a detailed compilation of important helium plasma chemistry reactions for simulating transient helium plasma discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of measurement and simulation of ATLAS cavern radiation background

Sixteen Medipix2 pixel detector based (MPX) devices were operated at various positions within the ATLAS detector and cavern continuously from early 2008 up to 2013. In addition to photons, each MPX detector is capable to detect charged particles, and neutrons as it is covered with a mask of converter materials dividing its area into regions sensitive to thermal or fast neutrons. The MPX detector network was effectively used for real-time measurements of the spectral characteristics and composition of complex radiation fields in ATLAS. This article reports comparison of the results of measurements performed with MPX detectors during the LHC operation period in 2010 and 2011 with Monte Carlo simulations results from the FLUGG and GCALOR codes. For the purpose of this comparison, the MPX detectors were operated in tracking mode with low threshold (8–10 keV) allowing one to distinguish among particle categories based on the recognition of track patterns left by the particles in the MPX sensitive layer. The comparison of measurements with simulations shows that the agreement between measured and simulated data is satisfactory in most cases within a factor of two.

47 OTHER INSTRUMENTATION↗

POGO-DB—a database of pairwise-comparisons of genomes and conserved orthologous genes

POGO-DB (http://pogo.ece.drexel.edu/) provides an easy platform for comparative microbial genomics. POGO-DB allows users to compare genomes using pre-computed metrics that were derived from extensive computationally intensive BLAST comparisons of >2000 microbes. These metrics include (i) average protein sequence identity across all orthologs shared by two genomes, (ii) genomic fluidity (a measure of gene content dissimilarity), (iii) number of ‘orthologs’ shared between two genomes, (iv) pairwise identity of the 16S ribosomal RNA genes and (v) pairwise identity of an additional 73 marker genes present in >90% prokaryotes. Users can visualize these metrics against each other in a 2D plot for exploratory analysis of genome similarity and of how different aspects of genome similarity relate to each other. The results of these comparisons are fully downloadable. In addition, users can download raw BLAST results for all or user-selected comparisons. Therefore, we provide users with full flexibility to carry out their own downstream analyses, by creating easy access to data that would normally require heavy computational resources to generate. POGO-DB should prove highly useful for researchers interested in comparative microbiology and benefit the microbiome/metagenomic communities by providing the information needed to select suitable phylogenetic marker genes within particular lineages.

59 BASIC BIOLOGICAL SCIENCES↗

Colloquium: Comparison of astrophysical and terrestrial frequency standards

The stability of pulse arrival times from pulsars and white dwarfs have been reanalyzed using several analysis tools for measuring the noise characteristics of sampled time and frequency data. The best terrestrial artificial clocks are shown to substantially exceed the performance of astronomical sources as timekeepers in terms of accuracy (as defined by cesium primary frequency standards) and stability. This superiority in stability can be directly demonstrated over time periods up to 2 years, where there is high quality data for both. Beyond 2 years there is a deficiency of data for clock-to-clock comparisons, and both terrestrial and astronomical clocks show equal performance being equally limited by the quality of the reference time scales used to make the comparisons. Nonetheless, the detailed accuracy evaluations of modern terrestrial clocks imply that these new clocks are likely to have a stability better than any astronomical source up to comparison times of at least hundreds of years. This article is intended to provide a correct appreciation of the relative merits of natural and artificial clocks. The use of natural clocks as tests of physics under the most extreme conditions is entirely appropriate; however, the contention that these natural clocks, particularly white dwarfs, can compete as timekeepers against devices constructed by mankind is shown to be doubtful.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-throughput computation of pairwise sequence similarities for multiple genome comparison using ScalaBLAST

Genome sequence comparisons of exponentially growing data sets form the foundation for the comparative analysis tools provided by community biological data resources such as the Integrated Microbial Genome (IMG) system at the Joint Genome Institute (JGI). For a genome sequencing center to provide multiple-genome comparison capabilities, it must keep pace with exponentially growing collection of sequence data, both from its own genomes, and from public genomes. We present an example of how ScalaBLAST, a high-throughput sequence analysis program, harnesses increasingly critical high-performance computing to perform sequence analysis, enabling, for example, all vs. all BLAST runs across 2 million protein sequences within a day using thousands of processors as opposed to conventional comparison methods that would take years to complete.

59 BASIC BIOLOGICAL SCIENCES↗

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to subhourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

accuracy↗

Land-use change trajectories up to 2050. Insights from a global agro-economic model comparison

Changes in agricultural land use have important implications for environmental services. Previous studies of agricultural land-use futures have been published indicating large uncertainty due to different model assumptions and methodologies. In this article we present a first comprehensive comparison of global agro-economic models that have harmonized drivers of population, GDP, and biophysical yields. The comparison allows us to ask two research questions: (1) How much cropland will be used under different socioeconomic and climate change scenarios? (2) How can differences in model results be explained? The comparison includes four partial and six general equilibrium models that differ in how they model land supply and amount of potentially available land. We analyze results of two different socioeconomic scenarios and three climate scenarios (one with constant climate). Most models (7 out of 10) project an increase of cropland of 10–25% by 2050 compared to 2005 (under constant climate), but one model projects a decrease. Pasture land expands in some models, which increase the treat on natural vegetation further. Across all models most of the cropland expansion takes place in South America and sub-Saharan Africa. In general, the strongest differences in model results are related to differences in the costs of land expansion, the endogenous productivity responses, and the assumptions about potential cropland.

54 ENVIRONMENTAL SCIENCES↗

Construction and comparison of three reference-quality genome assemblies for soybean

Here, we report reference-quality genome assemblies and annotations for two accessions of soybean (Glycine max) and for one accession of Glycine soja, the closest wild relative of G. max. The G. max assemblies provided are for widely used US cultivars: the northern line Williams 82 (Wm82) and the southern line Lee. The Wm82 assembly improves the prior published assembly, and the Lee and G. soja assemblies are new for these accessions. Comparisons among the three accessions show generally high structural conservation, but nucleotide difference of 1.7 single-nucleotide polymorphisms (snps) per kb between Wm82 and Lee, and 4.7 snps per kb between these lines and G. soja. snp distributions and comparisons with genotypes of the Lee and Wm82 parents highlight patterns of introgression and haplotype structure. Comparisons against the US germplasm collection show placement of the sequenced accessions relative to global soybean diversity. Analysis of a pan-gene collection shows generally high conservation, with variation occurring primarily in genomically clustered gene families. We found approximately 40-42 inversions per chromosome between either Lee or Wm82v4 and G. soja, and approximately 32 inversions per chromosome between Wm82 and Lee. We also investigated five domestication loci. For each locus, we found two different alleles with functional differences between G. soja and the two domesticated accessions. The genome assemblies for multiple cultivated accessions and for the closest wild ancestor of soybean provides a valuable set of resources for identifying causal variants that underlie traits for the domestication and improvement of soybean, serving as a basis for future research and crop improvement efforts for this important crop species.

59 BASIC BIOLOGICAL SCIENCES↗

Numerical Simulation Comparison of Two Reactor Configurations for Chemical Looping Combustion and Chemical Looping With Oxygen Uncoupling

Chemical looping with oxygen uncoupling (CLOU) is a carbon capture technology that utilizes a metal oxide as an oxygen carrier to selectively separate oxygen from air and release gaseous O 2 into a reactor where fuel, such as coal, is combusted. Previous research has addressed reactor design for CLOU systems, but little direct comparison between different reactor designs has been performed. This study utilizes Barracuda-VR® for comparison of two system configurations, one uses circulating fluidized beds (CFB) for both the air reactor (AR) and fuel reactor (FR) and another uses bubbling fluidized beds for both reactors. Initial validation of experimental and computational fluid dynamic (CFD) simulations was performed to show that basic trends are captured with the CFD code. The CFD simulations were then used to perform comparison of key performance parameters such as solids circulation rate and reactor residence time, pressure profiles in the reactors and loopseals, and particle velocities in different locations of the reactor as functions of total solids inventory and reactor gas flows. Here, using these simulation results, it was determined that the dual CFB system had larger range for solids circulation rate before choked flow was obtained. Both systems had similar particle velocities for the bottom 80% of particle mass, but the bubbling bed (BB) obtained higher particle velocities as compared to the circulating fluidized-bed FR, due to the transport riser. As a system, the results showed that the dual CFB configuration allowed better control over the range of parameters tested.

30 DIRECT ENERGY CONVERSION↗

Geometric interpretation of the {gamma} dose distribution comparison technique: Interpolation-free calculation

The {gamma} dose comparison tool has been used by numerous investigators to quantitatively compare multidimensional dose distributions. The {gamma} tool requires the specification of dose and distance-to-agreement (DTA) criteria for acceptable variations between the dose distributions. The tool then provides a comparison that simultaneously evaluates the dose difference and distance to agreement of the two dose distributions. One of the weaknesses of the tool is that the comparison requires one of the dose distributions to have a relatively high spatial resolution, with points spaced significantly closer than the DTA criterion. The determination of {gamma} involves an exhaustive search process, so the computation time is significant if an accurate {gamma} is desired. The reason for the need for high spatial resolution lies with the fact that the {gamma} tool measures the closest point in one of the dose distributions (the evaluated distribution) with individual points of the other distribution (the reference distribution) when the two distributions are normalized by the dose difference and DTA criteria for the dose and spatial coordinates, respectively. The closest point in the evaluated distribution to a selected reference distribution point is the value of {gamma} at that reference point. If individual evaluated dose distribution points are compared, the closest point may not accurately reflect the closest value of the evaluated distribution as if it were interpolated on an infinite resolution grid. Therefore, a reinterpretation of the {gamma} distribution as the closest geometric distance between the two distributions is proposed. This is conducted by subdividing the evaluated distribution into simplexes; line segments, triangles, and tetrahedra for one, two, and three-dimensional (3D) dose distributions. The closest distance between any point and these simplexes can be straightforwardly computed using matrix multiplication and inversion without the need of interpolating the original evaluated distribution. While an exhaustive search is still required, not having to interpolate the evaluated distribution avoids the drastic growth of calculation time incurred by interpolation and makes the {gamma} tool more practical and more accurate. In our experiment, the geometric method accurately computes {gamma} distributions between 3D dose distributions on a 200x200x50 grid within two minutes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of arc-modulated cone beam therapy and helical tomotherapy for three different types of cancer

Purpose: Arc-modulated cone beam therapy (AMCBT) is a fast treatment technique deliverable in a single rotation with a conventional C-arm shaped linac. In this planning study, the authors assess the dosimetric properties of single-arc therapy in comparison to helical tomotherapy for three different tumor types. Methods: Treatment plans for three patients with prostate carcinoma, three patients with anal cancer, and three patients with head and neck cancer were optimized for helical tomotherapy and AMCBT. The dosimetric comparison of the two techniques is based on physical quantities derived from dose-volume histograms. Results: For prostate cancer, the quality of dose distributions calculated for AMCBT was of equal quality as that generated for tomotherapy with the additional benefits of a faster delivery and a lower integral dose. For highly complex geometries, the plan quality achievable with helical tomotherapy could not be achieved with arc-modulated cone beam therapy. Conclusions: Rotation therapy with a conventional linac in a single arc is capable to deliver a high and homogeneous dose to the target and spare organs at risk. Advantages of this technique are a fast treatment time and a lower integral dose in comparison to helical tomotherapy. For highly complex cases, e.g., with several target regions, the dose shaping capabilities of AMCBT are inferior to those of tomotherapy. However, treatment plans for AMCBT were also clinically acceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of GEANT4 very low energy cross section models with experimental data in water

Purpose: The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H{sup 0}, H{sup +}) and (He{sup 0}, He{sup +}, He{sup 2+}), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so-called ''GEANT4-DNA'' physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re-engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. Methods: An evaluation of the closeness between the total and differential cross section models available in the GEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov-Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. Results: The authors have assessed the compatibility of experimental data with GEANT4 microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series exhibit significant deviations from each other. Conclusions: The GEANT4-DNA physics models available in the GEANT4 toolkit have been compared in this article to available experimental data in the water vapor phase as well as to several published recommendations on the mass stopping power. These models represent a first step in the extension of the GEANT4 Monte Carlo toolkit to the simulation of biological effects of ionizing radiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Use of volumetric features for temporal comparison of mass lesions in full field digital mammograms

Purpose: Temporal comparison of lesions might improve classification between benign and malignant lesions in full-field digital mammograms (FFDM). The authors compare the use of volumetric features for lesion classification, which are computed from dense tissue thickness maps, to the use of mammographic lesion area. Use of dense tissue thickness maps for lesion characterization is advantageous, since it results in lesion features that are invariant to acquisition parameters. Methods: The dataset used in the analysis consisted of 60 temporal mammogram pairs comprising 120 mediolateral oblique or craniocaudal views with a total of 65 lesions, of which 41 were benign and 24 malignant. The authors analyzed the performance of four volumetric features, area, and four other commonly used features obtained from temporal mammogram pairs, current mammograms, and prior mammograms. The authors evaluated the individual performance of all features and of different feature sets. The authors used linear discriminant analysis with leave-one-out cross validation to classify different feature sets. Results: Volumetric features from temporal mammogram pairs achieved the best individual performance, as measured by the area under the receiver operating characteristic curve (A{sub z} value). Volume change (A{sub z} = 0.88) achieved higher A{sub z} value than projected lesion area change (A{sub z} = 0.78) in the temporal comparison of lesions. Best performance was achieved with a set that consisted of a set of features extracted from the current exam combined with four volumetric features representing changes with respect to the prior mammogram (A{sub z} = 0.90). This was significantly better (p = 0.005) than the performance obtained using features from the current exam only (A{sub z} = 0.77). Conclusions: Volumetric features from temporal mammogram pairs combined with features from the single exam significantly improve discrimination of benign and malignant lesions in FFDM mammograms compared to using only single exam features. In the comparison with prior mammograms, use of volumetric change may lead to better performance than use of lesion area change.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer

Purpose: To compare contribution and accuracy of delivery for two flattening filter free (FFF) beams of the nominal energy 6 and 10 MV and a 6 MV flattened beam for early stage lung cancer. Methods: For each of 11 patients with stage I nonsmall cell lung cancer three volumetric modulated arc therapy plans were prepared utilizing a 6 MV flattened photon beam (X6FF) and two nonflattened beams of nominal energy 6 and 10 MV (X6FFF, X10FFF). Optimization constraints were set to produce dose distributions that meet the criteria of the RTOG-0915 protocol. The radiation schedule used for plan comparison in all patients was 50 Gy in five fractions. Dosimetric parameters of planning target volume (PTV) and organs-at-risk and delivery times were assessed and compared. All plans were subject to verification using Delta{sup 4} unit (Scandidos, Sweden) and absolutely calibrated gafchromic films in a thorax phantom. Results: All plans had a qualitatively comparable outcome. Obtained dose distributions were conformal (CI < 1.17) and exhibited a steep dose fall-off outside the PTV. The ratio of monitor units for FFF versus FF plans in the authors' study ranged from 0.95 to 1.21 and from 0.93 to 1.25 for X6FFF/X6FF and X10FFF/X6FF comparisons, respectively. The ratio systematically increased with increasing size of the PTV (up to +25% for 150 cm{sup 3} PTV). Yet the integral dose to healthy tissue did not follow this trend. Comparison of cumulative dose volume histograms for a patient's body showed that X6FFF plans exhibit improved conformity and reduced the volume of tissue that received more than 50% of the prescription dose. Parameters related to dose gradient showed statistically significant improvement. CI{sub 50%}, CI{sub 60%}, CI{sub 80%}, and CI{sub 100%} were on average reduced by 4.6% (p < 0.001), 4.6% (p = 0.002), 3.1% (p = 0.002), and 1.2% (p = 0.039), respectively. Gradient measure was on average reduced by 4.2% (p < 0.001). Due to dose reduction in the surrounding lung tissue, the V{sub 20} {sub Gy} and V{sub 12.5} {sub Gy} were reduced by 5.5% (p = 0.002) and 4.5% (p < 0.001). These dosimetric improvements in the fall-off were not observed for the X10FFF plans. Differences in sparing of normal tissues were not found to be statistically significant for either of the two FFF beams. Mean beam-on times were 111 s (2SD = 11 s) for X10FFF, 128 s (2SD = 19 s) for X6FFF, and X6FF plans required on average 269 s (2SD = 71 s). While the mean dose rate was 1555 ± 264 and 1368 ± 63 MU/min, for X10FFF and X6FFF, plans using the conventional X6FF were delivered with the constant maximum dose rate of 600 MU/min. Verification of all plans showed acceptable and comparable results for all plans in homogeneous as well as heterogeneous phantoms. Mean GS (3%, 2 mm) using the Delta{sup 4} phantom were 98.9% (2SD = 3.2%), 99.2% (2SD = 2.3%), and 99.2% (2SD = 2.3%) for X6FFF, X6FF, and X10FFF modalities. Verification using a thorax phantom showed GS > 98% in all cases. Conclusions: The use of FFF beams for stereotactic radiation therapy of nonsmall cell lung cancer patients yielded dose distributions qualitatively comparable to flattened beams and significantly reduced treatment delivery time. Utilizing the X6FFF beam improved conformity of dose distribution. On the other hand, X10FFF beam offered a slight improvement in treatment efficiency, and lower skin and peripheral dose. All effects were relatively small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-80: Comparison of Fluence-Based RapidArc QAs Using EPID and MapCHECK 2

Purpose: To compare the Varian aS-1000 EPID imager to the isocentrically mounted MapCHECK 2 diode array for RapidArc QAs as a function of photon beam energy. Methods: A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire RapidArc QA images for 13 patient plans; each plan QA was performed at 6, 8, 10 and 15MV energies. The Portal Dose Image Prediction algorithm in the Varian Eclipse treatment planning system (TPS) was used to create the comparison image for the EPID acquisition. A Sun Nuclear MapCHECK 2 diode array on an isocentric mounting fixture with 5 cm water-equivalent buildup was also used for the RapidArc QAs. A composite dose plane was taken from the Eclipse TPS for comparison to the MapCHECK 2 measurements. A gamma test was implemented in the Sun Nuclear Patient software with 10% threshold and absolute comparison for both QA methods. The two-tailed paired t-test was employed to analyze the statistical significance between two methods at the 95% confidence level. Results: The average gamma passing rates were greater than 95% at 3%/3mm using both methods for all four energies. The average passing rates were within 2.5% and 1.1% of each other when analyzed at 2%/2mm and 3%/3mm conditions, respectively. The EPID passing rates were somewhat better than the MapCHECK 2 when analyzed at 1%/1mm condition; this difference decreased with increasing energy (9.1% at 6MV to 2.7% at 15MV). The differences were not statistically significant for all criteria and energies (p-value ã 0.05). Conclusion: EPID-based RapidArc QA results are comparable to MapCHECK 2 when using 3%/3mm criteria at all four energies. EPID-based QA shows potential for being the superior device under strict gamma criteria.

60 APPLIED LIFE SCIENCES↗