Search NASA⌕ Search

SEARCH · Search NASA

Results for “computational fluid dynamics simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A Computational Investigation of Engine Heat Transfer with Ducted Fuel Injection

Ducted fuel injection (DFI) is an innovative method that curtails or prevents soot formation in direct-injection compression-ignition engines. DFI uses a simple duct, positioned outside each injector hole, facilitating the fuel/charge gas mixing before ignition. This reduces the equivalence ratio below two, in the autoignition zone, which in turn decreases soot formation. But this method also reduces fuel-conversion efficiency. This study investigates the effects of DFI on in-cylinder heat transfer. Experiments with conventional diesel combustion (CDC) and DFI were performed at four different dilution levels. Computational fluid dynamics (CFD) simulations were carried out at conditions matching those of the experiments, and the simulations were validated by the experimental data. The CFD simulations enabled to examine of in-cylinder heat release and temperature distributions. The heat transfer to the piston, head, and cylinder was investigated. The results show that DFI increased the heat transfer to the walls compared to CDC under the same conditions. This could help explain why DFI has been observed to reduce fuel-conversion efficiency by approximately 1% (absolute) relative to CDC under certain conditions. The efficiency loss typically decreases with dilution, such that DFI can improve fuel-conversion efficiencies relative to CDC at higher dilution levels.

Şener, Ramazan↗

Assessment of design and location of an active prechamber igniter to enable mixing-controlled combustion of ethanol in heavy-duty engines

Here, this numerical study focuses on assessing the key design parameters of interest for use of an active prechamber igniter as an ignition assistance device to enable mixing-controlled combustion (MCC) of ethanol (E100) in a heavy-duty Caterpillar C9.3B engine. Computational fluid dynamic (CFD) simulations of a baseline diesel and prechamber retrofitted C9.3B at a gross indicated mean effective pressure (IMEPg) of 5 bar and 1800 rpm are carried out using CONVERGE. In particular, the sizing of the prechamber volume, sizing of total orifice cross sectional area (orifice diameter), and location of the prechamber relative to a centrally mounted common rail direct injector are varied to discern the appropriate operational and design characteristics to achieve robust ignition assistance at the selected conditions. Simulation results indicate that use of an active prechamber igniter with E100 as a standalone fuel source can replicate ignition delays and thermal efficiencies similar to diesel combustion at the same engine boundary conditions, thus not requiring any changes to the engine’s air handling system. Igniter mounting location, orifice sizing, and jet targeting were found to have the strongest influence on ignition assistance with preference toward larger orifice diameters that appropriately located heating contributions in near vicinity to the direct injector.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling the impact of the fuel injection strategy on the combustion and performance characteristics of a heavy-duty GCI engine

Gasoline compression ignition (GCI) is a promising strategy to achieve high thermal efficiency and low emissions with limited modifications to the conventional diesel engine hardware. It is a partially premixed concept, which derives its superiority from higher volatility and longer ignition delay of gasoline-like fuels combined with higher compression ratio typical of diesel engines. Here, the present study investigates the combustion process in a GCI engine operating with different injection strategies using computational fluid dynamics (CFD). Simulations are carried out on a single cylinder of a multi cylinder heavy-duty compression ignition engine, which operates at a compression ratio of 17:1 and an engine speed of 1038 rev/min. Two different injection strategies viz., late injection (LI), and early pilot injection (EP) are investigated to understand their impact on combustion and performance of the engine. Renormalized group (RNG) k-ε model is used to describe in-cylinder turbulence and KH RT model is used to simulate the fuel spray breakup. The developed CFD methodology is validated against relevant experimental data under a wide range of operating conditions for each injection strategy. The developed CFD methodology was found to capture the engine combustion behavior quite well. Based on the validated CFD model, the differences in the progress of combustion event for the two injection strategies is highlighted. It was found that a larger pilot fuel mass fraction results in a steeper rise in the initial heat release rate which in turn influences the transition to mixing controlled combustion. In line with the experimental data, the study showed that the late pilot injection strategy with three injection pulses, results in higher performance compared to the other conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Realistic fuel spray modeling for gasoline direct injection engine applications

Fuel spray modeling plays a critical role during modern gasoline direct injection (GDI) engine development due to fuel injection’s dominant impact on engine performance and emissions as well as the complex physical processes involved. In engineering three-dimensional (3D) computational fluid dynamics (CFD) simulations, the liquid-phase fuel atomization, evaporation, and mixing are usually modeled with the discrete droplet model (DDM) adopting a Lagrangian approach for multiphase CFD simulations. To this end, general practices heavily depend on the reduced order characterization of the injector nozzle flow. However, such simplified injector modeling may lead to insufficient representations of the complex spray dynamics. To tackle this problem, this study proposes a novel workflow to numerically evaluate GDI sub-cooled and flash-boiling sprays under engine-relevant conditions using a side-mounted GDI injector together with real gasoline fuel properties. The workflow introduces a one-way coupling (OWC) method leveraging high-fidelity nozzle flow simulations to provide realistic boundary conditions to the Lagrangian injector model. The proposed workflow was first verified in a constant volume chamber (CVC) environment and then implemented in a practical GDI engine setup to study spray morphology, fuel-air mixing, and wall-wetting propensity. In addition, detailed comparison was performed between the OWC method and the conventional rate of injection (ROI) routine. In conclusion, quantitative analysis of spray characteristics was conducted to highlight possible source of discrepancies of the conventional ROI method.

33 ADVANCED PROPULSION SYSTEMS↗

Development of prechamber enabled mixing-controlled combustion strategy for ultra-low methane emissions from lean burn natural gas engines

This numerical study explores the optimization of Prechamber Enabled Mixing-Controlled Combustion (PC-MCC) using natural gas in heavy-duty engines, aiming to enhance combustion efficiency to minimize methane slip and NOx emissions. The approach involves a prechamber ignition system, distinct from conventional spark ignition (SI) systems, to initiate combustion of direct injected natural gas. By leveraging the robust ignition characteristics of the prechamber, the PC-MCC method demonstrates significant potential in achieving efficient combustion akin to diesel engines but with lower greenhouse gas emissions. The research evaluates the effects of various geometric and operational parameters on the combustion process and emissions, including prechamber volume, nozzle diameter, direct injector (DI) geometry, and engine operating strategies. Computational Fluid Dynamics (CFD) simulations are utilized, focusing on a heavy-duty, single-cylinder engine modeled after the Caterpillar C9.3B engine. Key findings indicate that a prechamber volume of 3 cc, coupled with a nozzle diameter of 2.75 mm for two prechamber holes, strikes an optimal balance between combustion efficiency and emissions reduction. This configuration ensures robust combustion across a range of operating conditions while maintaining methane slip within targeted limits. Further investigation into DI geometry shows the significance of the injector umbrella angle and nozzle diameter in shaping the fuel-air mixing and combustion dynamics. An umbrella angle of 130° and a nozzle diameter of 300 microns are identified as optimal, promoting rapid and efficient combustion with minimized methane and NOx emissions. The study also investigates the impact of injection timing and pressure, highlighting their roles in controlling combustion timing and influencing emissions levels. Advanced injection timing is found to be crucial in achieving the desired low methane slip, whereas retarded injection timing assists to reduce NOx emissions while having a slight increase in methane emissions. Operating strategies incorporating various levels of Exhaust Gas Recirculation (EGR) are assessed for their effectiveness in further reducing emissions. The research demonstrates that a judicious combination of internal hot EGR and careful calibration of DI pressure and SOI timing can achieve significant reductions in NOx emissions while keeping methane slip under control. Specifically, an internal EGR level of 15%–25%, combined with DI pressures of 200–300 bar and injection timings at or after top dead center, is recommended. These findings contribute valuable insights into the development of advanced combustion techniques for natural gas engines, offering a viable pathway to reduce methane slip without compromising engine efficiency or performance. The PC-MCC system presents a promising solution for the future of heavy-duty natural gas engine technology to reduce methane emissions.

Nsaif, Osama↗

Advanced Distillation Final Report

The Advanced Distillation project was concluded on December 31, 2009. This U.S. Department of Energy (DOE) funded project was completed successfully and within budget during a timeline approved by DOE project managers, which included a one year extension to the initial ending date. The subject technology, Microchannel Process Technology (MPT) distillation, was expected to provide both capital and operating cost savings compared to conventional distillation technology. With efforts from Velocys and its project partners, MPT distillation was successfully demonstrated at a laboratory scale and its energy savings potential was calculated. While many objectives established at the beginning of the project were met, the project was only partially successful. At the conclusion, it appears that MPT distillation is not a good fit for the targeted separation of ethane and ethylene in large-scale ethylene production facilities, as greater advantages were seen for smaller scale distillations. Early in the project, work involved flowsheet analyses to discern the economic viability of ethane-ethylene MPT distillation and develop strategies for maximizing its impact on the economics of the process. This study confirmed that through modification to standard operating processes, MPT can enable net energy savings in excess of 20%. This advantage was used by ABB Lumus to determine the potential impact of MPT distillation on the ethane-ethylene market. The study indicated that a substantial market exists if the energy saving could be realized and if installed capital cost of MPT distillation was on par or less than conventional technology. Unfortunately, it was determined that the large number of MPT distillation units needed to perform ethane-ethylene separation for world-scale ethylene facilities, makes the targeted separation a poor fit for the technology in this application at the current state of manufacturing costs. Over the course of the project, distillation experiments were performed with the targeted mixture, ethane-ethylene, as well as with analogous low relative volatility systems: cyclohexane-hexane and cyclopentane-pentane. Devices and test stands were specifically designed for these efforts. Development progressed from experiments and models considering sections of a full scale device to the design, fabrication, and operation of a single-channel distillation unit with integrated heat transfer. Throughout the project, analytical and numerical models and Computational Fluid Dynamics (CFD) simulations were validated with experiments in the process of developing this platform technology. Experimental trials demonstrated steady and controllable distillation for a variety of process conditions. Values of Height-to-an-Equivalent Theoretical Plate (HETP) ranging from less than 0.5 inch to a few inches were experimentally proven, demonstrating a ten-fold performance enhancement relative to conventional distillation. This improvement, while substantial, is not sufficient for MPT distillation to displace very large scale distillation trains. Fortunately, parallel efforts in the area of business development have yielded other applications for MPT distillation, including smaller scale separations that benefit from the flowsheet flexibility offered by the technology. Talks with multiple potential partners are underway. Their outcome will also help determine the path ahead for MPT distillation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Platform Li-Ion Battery Risk Assessment Tool (CRADA Final Report)

The pressure within a lithium-ion cell changes due to various chemical reactions. When a battery undergoes an unintended short circuit, the pressure changes are drastic - and often lead to uncontrolled failure of the cells. As part of work for others with Oceanit Laboratories Inc. for the NAVY STTR, NREL built Computational Fluid Dynamic (CFD) simulations that can identify potential weak spots inthe battery during such events, as well as propose designs to control violent failure of batteries.

25 ENERGY STORAGE↗

Development of a Hydrogasification Process for Co-Production of Substitute Natural Gas (SNG) and Electric Power from Western Coals

This report presents the results of the research and development conducted on an Advanced Hydrogasification Process (AHP) conceived and developed by Arizona Public Service Company (APS) under U.S. Department of Energy (DOE) contract: DE-FC26-06NT42759 for Substitute Natural Gas (SNG) production from western coal. A double-wall (i.e., a hydrogasification contained within a pressure shell) down-flow hydrogasification reactor was designed, engineered, constructed, commissioned and operated by APS, Phoenix, AZ. The reactor is ASME-certified under Section VIII with a rating of 1150 pounds per square inch gage (psig) maximum allowable working pressure at 1950 degrees Fahrenheit (°F). The reaction zone had a 1.75 inch inner diameter and 13 feet length. The initial testing of a sub-bituminous coal demonstrated ~ 50% carbon conversion and ~10% methane yield in the product gas under 1625°F, 1000 psig pressure, with a 11 seconds (s) residence time, and 0.4 hydrogen-to-coal mass ratio. Liquid by-products mainly contained Benzene, Toluene, Xylene (BTX) and tar. Char collected from the bottom of the reactor had 9000-British thermal units per pound (Btu/lb) heating value. A three-dimensional (3D) computational fluid dynamic model simulation of the hydrodynamics around the reactor head was utilized to design the nozzles for injecting the hydrogen into the gasifier to optimize gas-solid mixing to achieve improved carbon conversion. The report also presents the evaluation of using algae for carbon dioxide (CO 2 ) management and biofuel production. Nannochloropsis, Selenastrum and Scenedesmus were determined to be the best algae strains for the project purpose and were studied in an outdoor system which included a 6-meter (6M) radius cultivator with a total surface area of 113 square meters (m 2 ) and a total culture volume between 10,000 to 15,000 liters (L); a CO 2 on-demand feeding system; an on-line data collection system for temperature, pH, Photosynthetically Activate Radiation (PAR) and dissolved oxygen (DO); and a ~2 gallons per minute (gpm) algae culture dewatering system. Among the three algae strains, Scenedesmus showed the most tolerance to temperature and irradiance conditions in Phoenix and the best self-settling characteristics. Experimental findings and operational strategies determined through these tests guided the operation of the algae cultivation system for the scale-up study. Effect of power plant flue gas, especially heavy metals, on algae growth and biomass adsorption were evaluated as well.

01 COAL, LIGNITE, AND PEAT↗

Temperature Trends in Coal Char Combustion under Oxy-fuel Conditions for the Determination of Kinetics

Oxy-fuel combustion technology with carbon capture and storage could significantly reduce global CO 2 emissions, a greenhouse gas. Implementation can be aided by computational fluid dynamics (CFD) simulations, which require an accurate understanding of coal particle kinetics as they go through combustion in a range of environments. To understand the kinetics of pulverized coal char combustion, a heated flow reactor was operated under a wide range of experimental conditions. We varied the environment for combustion by modifying the diluent gas, oxygen concentration, gas flow rate, and temperature of the reactor/reacting gases. Measurements of reacting particle temperatures were made for a sub-bituminous and bituminous coal char, in environments with CO 2 or N 2 as the diluent gas, with 12, 24, and 36 vol-% oxygen concentration, at 50, 80, 100, and 200 standard liters per minute flowing through the reactor, reactor temperatures of 1200, 1400 K, at pressures slightly above atmospheric. The data shows consistent increasing particle temperature with increased oxygen concentration, reactor temperature and higher particle temperatures for N 2 diluent than CO 2 . We also see the effects of CO 2 gasification when different ranks of coal are used, and how the reduction in the temperature due to the CO 2 diluent is greater for the coal char that has higher reactivity. Quantitative measurements for temperature are not yet complete due to ongoing calibration of detection systems.

01 COAL, LIGNITE, AND PEAT↗

V&V Of CFD Modeling Of The Argonne Bubble Experiment: FY15 Summary Report

In support of the development of accelerator-driven production of the fission product Mo 99, computational fluid dynamics (CFD) simulations of an electron-beam irradiated, experimental-scale bubble chamber have been conducted in order to aid in interpretation of existing experimental results, provide additional insights into the physical phenomena, and develop predictive thermal hydraulic capabilities that can be applied to full-scale target solution vessels. Toward that end, a custom hybrid Eulerian-Eulerian-Lagrangian multiphase solver was developed, and simulations have been performed on high-resolution meshes. Good agreement between experiments and simulations has been achieved, especially with respect to the prediction of the maximum temperature of the uranyl sulfate solution in the experimental vessel. These positive results suggest that the simulation methodology that has been developed will prove to be suitable to assist in the development of full-scale production hardware.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Computational Fluid Dynamic Analysis for the Proposed VHTR Lower Plenum Standard Problem

One of the reference designs for the Next Generation Nuclear Plant (NGNP) is a prismatic reactor configuration. A major concern in the operation of this design is the nature of the flow of hot gas as it exits the core into the lower plenum and then out the vessel exit duct. The two primary areas of concern are the impingement of hot jets onto the walls of the lower plenum and the degree of thermal mixing of the helium coolant as it flows out of the reactor vessel. Computational fluid dynamic (CFD) simulations have been proposed by general consensus to estimate the desired local fluid dynamic and temperature information. Successful CFD simulations require careful planning and extensive calculations to help ensure that they accurately represent the flow physics. An important aspect of the application of CFD is to validate the results against detailed validation data, for scaled problems that involve similar physics. A section of the lower plenum of the reference prismatic NGNP was employed to create a scaled model to use to obtain experimental data for use as validation data to compare with a CFD analysis. Extensive flow data were obtained from the scaled model while installed in the INL’s Matched Index of Refraction (MIR) test facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Risk Assessment of Catastrophic Leak Of R-452b From Package Unit into A Residential Space

With the effort to find alternative refrigerants with lower global warming potential (GWP), challenges have arisen due to the flammability risk for many of the alternatives. One of the new alternatives is R-452B, which is recommended as a replacement for R410A. R-452B is classified as a mildly flammable refrigerant (A2L) by ANSI/ASHRAE Standard 34. This paper summarizes a computational fluid dynamic (CFD) simulation study of a leak incident of R-452B from a 3-ton packaged unit which serves a 167 m 2 residence. The R-452B leak is assumed to be downstream of the evaporator coil. The simulated residence has four rooms and a hallway. The packaged unit distributes the conditioned air through a supply duct system delivering the air through registers. The dispersion of R-452B is characterized for two scenarios: one with underfloor supply air ducts and another with ceiling supply air ducts. The mass flow rate of R-452B exiting the duct outlets is quantified and the refrigerant volume fraction is monitored inside the residential space.

42 ENGINEERING↗

ECAR-5067 Computational Evaluation on Effect of Edge-rounding in Circular to Annular Flow Transitions within a Hexagonal Duct

In this ECAR, the computational fluid dynamics (CFD) simulation of the duct with a cross-section varying from circle to annulus was performed to evaluate the effect of edge-rounding of the internal edges. The edge of circular channel and the edge of inner annular channel were rounded with the radius of curvature ranged from 0 mm to 20 mm. The CFD results show that the pressure loss of the duct can be reduced by increasing the radius of the rounded edge. Case-A results showed that the pressure drop can be significantly reduced by the edge-rounding, e.g., the pressure drop was reduced approximately 56% by the radius of curvature of 5.0mm, and reduced 70% by the radius of curvature of 20.0 mm although its effectiveness would be attenuated as the radius of curvature of edge increases. Results from Case-B showed the impact of rounding the inlet edge was practically negligible compared to the outlet edge. This ECAR could provide a guideline to determine the optimum inlet module design of the VTR fuel rod bundle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Studies of Alternative Ventilation Configurations to Mitigate Airborne Exposure Risks in Office Spaces

The objective of this study was to evaluate the impact of alternative ventilation configurations on airflow patterns and potential exposure risks in office spaces. Two existing conference rooms at Sandia NM were modeled using Computational Fluid Dynamics (CFD) simulations to characterize airflow patterns and potential airborne exposure risks in well-mixed and once-through (through-flow) ventilation conditions. Multiple scenarios were studied to evaluate the impact of occupancy, Plexiglass barriers, and a modified-return airflow configuration. Experimental and visualization tests were also conducted to validate the well-mixed and through-flow models and findings. The simulations demonstrated that the modified-return airflow configuration that promoted through-flow conditions reduced pathogen concentrations within the space compared to the well-mixed airflow configuration; occupancy reduction only reduced the number of exposed individuals, and Plexiglass barriers had almost no effect. The experimentally measured air speeds at nine anemometer locations generally matched the simulated airflow velocities, and a fog-purge visualization test was also consistent with simulated results of plume movement and dissipation. The visualization tests demonstrated improvements in air change rate with the modified return, which promoted through-flow conditions, versus the original well-mixed ventilation configuration. The results of this study demonstrate that minor modifications to a space that promote through-flow conditions can improve air quality and reduce pathogen concentrations. Additional airflow modeling and testing of alternative occupied space configurations are recommended to further inform room designs that mitigate airborne exposure risks for occupants.

42 ENGINEERING↗

Computational and Experimental Validation of Fractal-Fin, Dimpled Solar Heat Collector

A 3 foot x 3 foot x 3 foot aluminum solar collector was manufactured using computer numerical control. The interior of the device included six triangular dimpled fins for enhanced heat transfer. The interior vertical wall on the south side was also dimpled. The solar collector working fluid was based on water, and the collector consisted solely of passive heat transfer mechanisms (no moving parts), making it ideal for off-the-grid and rural applications. Two types of heat transfer experiments were conducted. One experiment had external flat heaters attached on the top and the front side, while the other four sides were insulated. Except for the bottom surface, the second experiment had all its exterior surfaces sprayed with black solar paint to collect as much solar heat as possible. Temperature data as a function of time was collected using 14 thermocouples spread strategically throughout the solar collector. In addition, computational fluid dynamics (CFD) simulations were conducted using the dynamic Smagorinsky large eddy simulation turbulence model. The first simulation considered that both the top and front surfaces were exposed to a fixed temperature of 313.7 K (105 °F), while the remaining four surfaces were insulated. For the second simulation, all conditions were the same, except that the temperature for both heated surfaces was raised to 350 K (170.3 °F). The two temperatures are expected to bound the solar collector operational temperature during the late- Spring, Summer, and early-Fall months. The solar collector design, experimental data, CFD output, and a discussion of five manufacturing approaches and costs are documented in this report.

14 SOLAR ENERGY↗

Isolated Building Wake Experiment At Texas Tech University’s Wind Engineering Research Field Lab

Texas Tech University’s (TTU’s) Wind Engineering Research Field Lab (WERFL) building is an idealized rectangular building on the scale of a typical suburban house. It is surrounded almost entirely by unobstructed planes and is built on a turn table. WERFL is ideal for providing measurements of an idealized building under real-world conditions including atmospheric stability and variable relative wind angles. The intent of this data set is for verification and validation of computational fluid dynamics model simulations of flow around buildings. The primary focus of this dataset features 24 3D sonic anemometers (20 downwind and 4 upwind) and 10 2D sonic anemometers (9 downwind and 1 upwind) located in the immediate vicinity of the WERFL building. It also includes a variety of instruments intended to measure the ambient meteorological parameters and the undisturbed wind profile.

17 WIND ENERGY↗

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗