Analytical and experimental investigation of stator endwall countouring in a small axial-flow turbine
An experimental and analytical investigation was conducted to determine the effect of stator endwall contouring on turbine stage performance. In this investigation three stator configurations were evaluated using a common rotor. The three stator configurations were a cylindrical endwall design and two contoured endwall designs, one having a S-shaped outer wall profile and the other having a conical-shaped outer wall profile. Experimental data were obtained over a range of equivalent speeds, total pressure ratios, and rotor tip clearances for each stator-rotor combination. Detailed analytical loss assessments were conducted to aid in the determination of the contouring effect on turbine performance.