Search NASA⌕ Search

SEARCH · Search NASA

Results for “design standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Magnetic, Mechanical and Thermal Modeling of Superconducting, Whole-Body, Actively Shielded, 3 T MRI Magnets Wound Using MgB 2 Strands for Liquid Cryogen Free Operation

Here we present magnetic, mechanical and thermal modeling results for a 3 Tesla actively shielded whole body MRI (Magnetic Resonance Imaging) magnet consisting of coils with a square cross section of their windings. The magnet design was a segmented coil type optimized to minimize conductor length while hitting the standard field quality and DSV (Diameter of Spherical Volume) specifications as well as a standard, compact size 3 T system. It had an overall magnet length and conductor length which can lead to conduction cooled designs comparable to NbTi helium bath cooled 3 T MRI magnets. The design had a magnetic field homogeneity better than 10 ppm (part-per-million) within a DSV (Diameter of Spherical Volume) of 48 cm and the total magnet winding length of 1.37 m. A new class of MgB 2 strand especially designed for MRI applications was considered as a possible candidate for winding such magnets. This work represents the first magnetic, mechanical and thermal design for a whole-body 3 T MgB 2 short (1.37 m length) MRI magnet based on the performance parameters of existing MgB 2 wire. 3 Tesla MRI magnet can operate at 20 K at 67% of its critical current.

43 PARTICLE ACCELERATORS↗

Converting Clinical Pathways to BPM+ Standards: A Case Study in Stable Ischemic Heart Disease

Clinical pathways (CPs) are structured healthcare plans designed to implement evidence-based clinical guidelines, medical algorithms, and protocols. In recent years, a community called BPM+ Health has worked to establish a shareable and computer-consumable representation of CP, leveraging standard notations. These notations, collectively referred to as BPM+, include the Business Process Management and Notation (BPMN), Case Management Model and Notation (CMMN), and Decision Model and Notation (DMN), which aim to support clinical management and standardized communication between different stakeholders. However, the adaptation of these notations for the existing guidelines has largely been left unexplored. This paper introduces procedural steps and criteria considerations to apply components of BPM+ notations to reconstruct a guideline for Stable Ischemic Heart Disease. This paper describes how each of the three different notations is mapped to a medical guideline and discusses the advantages and limitations of representing CPs with BPM+ as compared with paper-based medical guidelines.

Chae, Junghoon↗

State Indicators for Advancing Demand Flexibility and Energy Efficiency in Buildings - Part I [Slides]

This slide deck report identifies objectives and key indicators for state activities that advance demand flexibility in buildings — legislation, utility regulatory proceedings, executive orders and programs. It also illustrates progress to date and identifies trends, gaps, and opportunities. Part I of the report focuses on (1) demand response and (2) energy efficiency targeted to reduce peak demand or integrate with demand response. This section covers building energy codes, appliance and equipment standards, resource standards, utility planning, utility programs, advanced metering infrastructure and meter data, rate design, state programs, state energy planning, and related state policies and regulations. Part II of the report addresses traditional energy efficiency indicators, including utility and state programs, codes, and standards that support annual energy savings. See the additional links for an infographic, library of cited state documents on demand flexibility, and presentation to the NASEO-NARUC Grid-Interactive Efficient Buildings Working Group.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The state of the art for neutron irradiation experiments from the perspective of the High Flux Isotope Reactor (HFIR)

Irradiation experiment campaigns are critical to advancing nuclear energy technologies by providing data on material performance under relevant radiation conditions. Successful irradiation experiments require integrated design efforts that balance technical goals with facility constraints. Here, this paper presents an expert-informed overview of irradiation experiment design at the High Flux Isotope Reactor. It addresses the nuclear materials research and irradiation experiment communities to guide them toward developing technically sound, facility-compatible campaigns. The High Flux Isotope Reactor is a multipurpose reactor supporting isotope production, neutron scattering, and materials testing. Its high, steady-state neutron flux is ideal for irradiation experiments, but successful execution demands coordinated thermal, structural, and reactor physics analyses. The paper outlines the complete development workflow from concept definition and design optimization to safety qualification and post-irradiation examination. Standardized capsule platforms are also discussed in terms of flexibility, specimen capacity, and thermal performance. Common failure modes such as unanticipated geometric variations, can impact temperature-dose profiles and compromise data reliability. Therefore, detailed thermal modeling and accurate as-built characterization are essential for meaningful post-irradiation data interpretation. Key recommendations include early engagement all stakeholders, clearly defined design expectations, and alignment of specimen geometries with post-irradiation examination capabilities. This approach reduces design iterations, enhances data quality, and supports more efficient use of irradiation resources. Strategic and well-planned irradiation testing not only improves individual campaign success but also accelerates the deployment of advanced nuclear technologies. By closing critical data gaps and reducing development risks, the nuclear materials community can more effectively contribute to the future of clean, resilient energy systems.

Experiments↗

The waterSHED Model: User Guide

The ideal design and operation of small hydropower plants is a complex optimization problem with economic, social, and environmental objectives. The waterSHED (Water Allocation Tool Enabling Rapid Small Hydropower Environmental Design) model is a user-friendly tool that allows hydropower stakeholders to model the trade-offs among these objectives using the Standard Modular Hydropower (SMH) framework. The SMH framework employs modular technologies that can be represented as blackbox objects and combined within a river to create a hydropower facility. For a given site, the waterSHED model aims to determine which modules should be placed in a facility and how those modules should be operated. This user guide describes how to use the graphical user interface and related functionalities. This document also summarizes the background research and mathematical formulations that are explained indepth in the accompanying doctoral dissertation. This model is an early step toward a new hydropower design process that employs standardization and modularity to reduce costs, development timelines, and challenges regarding social and environmental mitigation measures for low-head, small hydropower development. The waterSHED model is a Python application that will require the ability to download a GitHub repository, import the necessary packages, and run a set of Python script files using an integrated development environment. The script produces a graphical user interface to coordinate inputs, simulate operation, and visualize results, so no coding experience is needed once the script is running. Additionally, the waterSHED Workbook is a Microsoft Excel file that works with the Python script to facilitate data entry

13 HYDRO ENERGY↗

A Risk-Informed Performance-Based Methodology to Manage Fire Protection Systems in Nuclear Facilities

Fire protection systems (FPSs) and features are installed in U.S. Department of Energy (DOE) Hazard Category 1, 2, or 3 nuclear facilities to protect property (maximum possible fire loss thresholds), life, and nuclear safety (i.e., structures, systems, and components). These FPSs and features are designed and maintained in accordance with the prescriptive guidance provided in applicable building codes and National Fire Protection Association codes and standards. Management, operations, and maintenance activities of FPSs involve significant effort. A DOE facility’s documented safety analysis or other safety basis document could also rely on FPSs to provide either a safety significant or safety class function to mitigate fire hazards and minimize radiological consequences. In some cases, the designation of safety significant or safety class may be determined to provide a layer of defense-in-depth to minimize nuclear safety risks independent of the fire risk. DOE standards allow the use of performance-based design alternatives developed by the fire industry but do not consider the defense-in-depth layers of protection provided in DOE facilities to prevent or mitigate the risks associated with unintended release of radioactive materials into the environment. Pacific Northwest National Laboratory developed a decision-making methodology tailored for DOE non-reactor nuclear facilities to manage FPSs and features by integrating nuclear safety risk insights into a performance-based analysis. This risk-informed, performance-based (RIPB) methodology can be used to provide the technical basis for classifying an FPS as safety class and safety significant, tailoring administrative controls (e.g., technical safety requirements), and ranking the importance of FPSs to prioritize maintenance, upgrades, and replacement activities. The RIPB methodology is a graded approach to inform DOE facility owners and Fire Protection Program managers of the most risk-significant FPSs and equipment, and those systems would be cost-beneficial to relax rigor if there is a need to re-design the FPS coverage or deviate from DOE and National Fire Protection Association standards for those systems that would be less significant. This paper describes the framework used to develop the RIPB methodology and the outcome of implementing this methodology in a use-case nuclear facility. This paper also discusses the impact to DOE policies and standards and the safety margins and defense-in-depth measures credited in nuclear safety assessments in a facility’s documented safety analysis and the benefits of implementing an RIPB methodology in lieu of a prescriptive method to comply with fire protection requirements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pilot-Scale Modular Research Facility for Acidic Water Pollution Cleanup and Domestic Production of Critical Minerals for National Security

A recent study by Penn State researchers revealed that Pennsylvania AMD streams originate from abandoned mines, with coal refuse piles of the lower Kittanning coal seam containing the most valuable heavy rare earth elements. Penn State has developed a three-stage process to recover these critical minerals, tested it for proof of concept, and secured a patent. Funded by the US DOE, a modular pilot-scale research and development unit has been designed and built to process 1,000 gallons per day of AMD from a site managed by the Pennsylvania Department of Environmental Protection (PA DEP). The system will selectively recover iron, aluminum, rare earth elements, and cobalt-nickel-manganese concentrates from AMD, followed by a proprietary downstream purification process. These operations aim to produce concentrates of critical minerals while treating acid mine drainage to meet environmental standards and evaluate different feedstocks. This presentation will describe the design, operation, and innovations of the proposed process and pilot facility, emphasizing its role in promoting sustainable recovery of critical minerals from legacy waste streams.

Pisupati, Sarma V [Center for Critical Minerals, T↗

Progress in the development of the community Particle Accelerator Lattice Standard (PALS)

The Particle Accelerator Lattice Standard (PALS) is a community effort to create an open standard to promote lattice information exchange for particle accelerators. PALS development is a community-wide international effort involving accelerator physicists from multiple institutions. While it started as a lattice standard for beam dynamics simulations, it is now being extended to support other particle accelerator activities, in particular accelerator operation. With new accelerators that are becoming more complex, larger collaborations and the increasing imprint of artificial intelligence in all accelerator activities (from design to operation to workforce development), the imperative for a common, standardized accelerator ontology has been transitioning from “nice-to-have” to “must-have”. We will present the status of the project, its relations to other projects, including to two of the particle accelerator projects of the newly announced US DOE Genesis Mission: the Multi-Office Accelerator Team (MOAT) project and the Nuclear physics AI-Ready Accelerator Data (NARAD) project.

Brynes, A. [Science and Technology Facilities Coun↗

Is 3D/2D Passivation a Secret to Success for Polycrystalline Thin-Film Solar Cells?

Three leading thin-film photovoltaic (PV) technologies - cadmium telluride (CdTe), CuIn1-xGaxSe2 (CIGS), and perovskite solar cells (PSCs) - are all polycrystalline, but otherwise appear to have little in common. A comprehensive examination of these technologies, however, reveals a common theme: the formation of two-dimensional (2D) van der Waals materials at three-dimensional (3D) absorber interfaces and grain boundaries. In CdTe, the 2D compound is CdCl2; in CIGS, it is XInSe2 (X= K, Rb, Cs) with X depending on the heavy-alkali post-deposition treatment used; and in lead halide PSCs, PbI2 forms naturally, but many new, more stable, 2D perovskites have also been incorporated. Generally, these 2D interfacial materials are present not by design, but instead have evolved from their 3D counterparts during standard device processing. Here, new data, together with evidence compiled from the literature, are presented to illustrate both the existence of 3D/2D interfaces in CdTe, CIGS, and PSCs, and their correlation with improved passivation and device performance. This suggests that 3D/2D passivation may be a heretofore unappreciated key to successful polycrystalline thin-film PV. Finally, the desired attributes of successful low-dimensional layers are presented with rational design strategies for next generation polycrystalline solar cells.

3D/2D↗

Analysis of Completion Design Impact on Cluster Efficiency and Pressure-Based Well Communication in HFTS-2 Delaware Basin

The Hydraulic Fracturing Test Site 2 (HFTS-2) is a joint industry project in the Delaware basin to advance hydraulic fracturing understanding and improve productivity in shale reservoirs. The project integrates multi-disciplinary approaches to evaluate different completion designs, well spacing, inter-well communication, and stimulated rock volume, among other factors. This paper focused on two major areas related to hydraulic fracture performance. First, an analysis of different completion designs on cluster efficiency based on near well Distributed Acoustic Sensing (DAS). Second, an evaluation of well and completion designs on inter-well fracture driven interactions (FDIs) based on downhole pressure monitoring. Fluid/sand distribution and cluster efficiency analyses were based on near wellbore DAS data collected from two adjacent horizontal wells completed in two different landing zones in the Wolfcamp formation. These wells had different completion designs aiming to evaluate the effect of normal vs. extended stage lengths, perforation hole tapering and limited entry. Standard deviation from ideal fluid/sand distribution and waterfall plots were used to evaluate cluster efficiency for each design and stage. Inter-well FDIs analysis was conducted among the horizontal wells and a vertical monitor well. One horizontal well served as the monitor well while the other horizontal well was being treated. The vertical well was instrumented with downhole pressure and temperature gauges to aid monitoring fracture height growth. The pressure response during and after fracturing was characterized based on maximum pressure increase value and slope. Pressure response vs. FDIs trigger factors such distance, cluster efficiency and stage fluid volume were also analyzed. Based on the different completion and perforation designs tested, DAS analysis suggests that limited entry design worked best. Extreme limited entry showed the potential of high perforation erosion and reduced cluster efficiency. Here, the limited entry and tapered perforation design demonstrated potential to improve the cluster efficiency for extended stage lengths. Pressure monitoring across formation units proved to be critical to understand fracture interactions and fracture vertical growth. Pressure communication across different formation units during hydraulic fracturing operation indicate fractures grew upwards during Wolfcamp wells fracturing. However, this pressure communication dissipated over time. High intensity FDIs were recorded when the frac stages Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/1-21URTC/D011S018R001/2477607/urtec-2021-5289-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5289 were closer to the pressure gauge location in the monitor wells. Some of these stages that produced high intensity FDIs also had high fluid volume per cluster and low cluster efficiency. The multi-disciplinary and high-quality data collected from HFTS-2 helped to further understand why completion approaches such as limited entry and tapered perforation design are successful in improving cluster efficiency. The DAS data combined with downhole high-resolution pressure measurements also helped to quantify the effect of lower cluster efficiency data on the incidence and intensity of FDIs.

58 GEOSCIENCES↗

Airborne Release Fractions from Surrogate Nuclear Waste Fires Containing Lanthanide Nitrates and Depleted Uranium Nitrate in 30% Tributyl Phosphate in Kerosene

Airborne contaminants from fires containing nuclear waste represent significant health hazards and shape the design and operation of nuclear facilities. Much of the data used to formulate DOE-HDBK-3010-94, “Airborne Release Fractions/Rates and Respirable Fractions for Nonreactor Nuclear Facilities,” from the U.S. Department of Energy, were taken over 40 years ago. The objectives of this study were to reproduce experiments from Pacific Northwest Laboratories conducted in June 1973 employing current aerosol measurement methods and instrumentation, develop an enhanced understanding of particulate formation and transport from fires containing nuclear waste, and provide modeling and experimental capabilities for updating current standards and practices in nuclear facilities. A special chamber was designed to conduct small fires containing 25 mL of flammable waste containing lutetium nitrate, ytterbium nitrate, or depleted uranium nitrate. Carbon soot aerosols showed aggregates of primary particles ranging from 20 to 60 nm in diameter. In scanning electron microscopy, ~200-nm spheroidal particles were also observed dispersed among the fractal aggregates. The 200-nm spherical particles were composed of metal phosphates. Airborne release fractions (ARFs) were characterized by leaching filter deposits and quantifying metal concentrations with mass spectrometry. The average mass-based ARF for 238 U experiments was 1.0 × 10 -3 with a standard deviation of 7.5 × 10 -4 . For the original experiments, DOE-HDBK-3010-94 states, “Uranium ARFs range from 2 × 10 -4 to 3 × 10 -3 , an uncertainty of approximately an order of magnitude.” Therefore, current measurements were consistent with DOE-HDBK-3010-94 values. ARF values for lutetium and ytterbium were approximately one to two orders of magnitude lower than 238 U. Furthermore, metal nitrate solubility may have varied with elemental composition and temperature, thereby affecting ARF values for uranium surrogates (Yb and Lu). In addition to ARF data, solution boiling temperatures and evaporation rates can also be deduced from experimental data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Genus Definition for Bacteria and Archaea Based on a Standard Genome Relatedness Index

In recent decades, the taxonomy of Bacteria and Archaea , and therefore genus designation, has been largely based on the use of a single ribosomal gene, the 16S rRNA gene, as a taxonomic marker. We propose an approach to delineate genera that excludes the direct use of the 16S rRNA gene and focuses on a standard genome relatedness index, the average nucleotide identity. Our findings are of importance to the microbiology community because the emergent properties of Bacteria and Archaea that are identified in this study will help assign genera with higher taxonomic resolution.

59 BASIC BIOLOGICAL SCIENCES↗

Muon to electron conversion search in the presence of Al nuclei at the Fermilab Mu2e experiment: Motivation, Design and Progress

The Mu2e experiment aims to find charged lepton flavor violation(CLFV) by measuring the monochromatic electrons from $\mu^- N\rightarrow e^- N$ conversion with an unprecedented single event sensitivity of $3 \times 10^{-17}$. When completed the experiment will improve the current limit by four orders of magnitude and make a previously unexplored phase space available for the search for beyond the standard model physics. Physics motivation for the experiment is discussed and design choices for the detectors and various sub systems are explained in this document. The construction of the Mu2e experiment is well underway and commissioning will begin in late 2022 with first data taking in late 2025 and 4-5 years of data taking thereafter to reach our goal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of digital acquisition for beam current monitor

As a part of the Proton Improvement Plan – II (PIP-II) at Fermilab, instrumentation systems are being modernized to take advantage of the higher speeds and ease of use offered by standardized embedded systems like MicroTCA. A rear-transition module (RTM) is being designed to interface with said embedded systems. In each of the four identical channels on the RTM, the differential signal from an alternating-current current transformer (ACCT) transimpedance amplifier will again be amplified by a differential operation-amplifier, then filtered by a low-pass topology. The conditioned signal is then digitized at a maximum of 10MS/s by an analog to digital converter (ADC) integrated circuit. After digitization, the ADC passes the data to an off the shelf AdvancedMC (AMC) Xilinx FPGA module using low voltage differential signals. This paper will describe the simulation of analog circuitry for signal conditioning, simulation of digital signal integrity based on physical design as well as verification of design characteristics critical to signal integrity. This work aims to create a methodology that can be applied to future RTMs requiring application of high-speed digital design principles.

White, R.Turner [Fermilab]↗

Design of Digital Acquisition for Beam Current Monitor

As a part of the Proton Improvement Plan II (PIP-II) at Fermilab, instrumentation systems are being modernized to take advantage of the higher speeds and ease of use offered by standardized embedded systems like MicroTCA. A rear-transition module (RTM) is being designed to interface with said embedded systems. In each of the four identical channels on the RTM, the differential signal from an alternating-current current transformer (ACCT) transimpedance amplifier will again be amplified by a differential operation-amplifier, then filtered by a low-pass topology. The conditioned signal is then digitized at a maximum of 10MS/s by an analog to digital converter (ADC) integrated circuit. After digitization, the ADC passes the data to an off the shelf AdvancedMC (AMC) Xilinx FPGA module using low voltage differential signals. This paper will describe the simulation of analog circuitry for signal conditioning, simulation of digital signal integrity based on physical design as well as verification of design characteristics critical to signal integrity. This work aims to create a methodology that can be applied to future RTMs requiring application of high-speed digital design principles.

White, Turner [Fermilab] (ORCID:0009000348159256)↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Towards a New μ→eγ Search with the MEG II Experiment: From Design to Commissioning

The MEG experiment represents the state of the art in the search for the Charged Lepton Flavour Violating μ + →e + γ decay. With its first phase of operations at the Paul Scherrer Institut (PSI), MEG set the most stringent upper limit on the BR (μ + →e + γ) ≤ 4.2×10 –13 at 90% confidence level, imposing one of the tightest constraints on models predicting LFV-enhancements through new physics beyond the Standard Model. An upgrade of the MEG experiment, MEG II, was designed and it is presently in the commissioning phase, aiming at a sensitivity level of 6×10 –14 . The MEG II experiment relies on a series of upgrades, which include an improvement of the photon detector resolutions, brand new detectors on the positron side with better acceptance, efficiency and performances and new and optimized trigger and DAQ electronics to exploit a muon beam intensity twice as high as that of MEG (7×10 7 μ + /s). This paper presents a complete overview of the MEG II experimental apparatus and the current status of the detector commissioning in view of the physics data taking in the upcoming three years.

79 ASTRONOMY AND ASTROPHYSICS↗

A systematic literature review on residential demand response with a focus on opportunities for low-income communities

Demand Response improves efficiency and grid stability, reducing peak load and total system costs. It can potentially contribute to other societal aspects, including mitigating climate change and improving air quality, health, stress levels, and comfort. This paper reviewed the literature on residential demand response programs in the United States, through the lens of the five energy justice principles, identifying and categorizing a set of 165 papers from 1960 to 2024. As a result, we observe significant progress in distributive justice, however, mostly focused on increasing participation rather than attending specific needs of historically marginalized communities. Concordantly, recognition and procedural justice dimensions are lagging, while cosmopolitan justice studies are scarce, underscoring a need to improve the measurement of impacts resulting from the implementation of demand response programs. Future research opportunities include the consolidation of standardized definitions and metrics, to better understand burdens and needs of diverse residential users. In terms of policy, collection and transparent access to standardized data is required as a condition to the design of flexible, customizable, transparent, and easy to navigate demand response programs. As a result, a better understanding of and engagement with customers has the potential to increase adoption rates, persistence in the program, and overall impacts for the system, households, and society.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗