Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Online anomaly detection for multi‐source VMware using a distributed streaming framework

Summary Anomaly detection refers to the identification of patterns in a dataset that do not conform to expected patterns. Such non‐conformant patterns typically correspond to samples of interest and are assigned to different labels in different domains, such as outliers, anomalies, exceptions, and malware. A daunting challenge is to detect anomalies in rapid voluminous streams of data. This paper presents a novel, generic real‐time distributed anomaly detection framework for multi‐source stream data. As a case study, we investigate anomaly detection for a multi‐source VMware‐based cloud data center, which maintains a large number of virtual machines (VMs). This framework continuously monitors VMware performance stream data related to CPU statistics (e.g., load and usage). It collects data simultaneously from all of the VMs connected to the network and notifies the resource manager to reschedule its CPU resources dynamically when it identifies any abnormal behavior from its collected data. A semi‐supervised clustering technique is used to build a model from benign training data only. During testing, if a data instance deviates significantly from the model, then it is flagged as an anomaly. Effective anomaly detection in this case demands a distributed framework with high throughput and low latency. Distributed streaming frameworks like Apache Storm, Apache Spark, S4, and others are designed for a lower data processing time and a higher throughput than standard centralized frameworks. We have experimentally compared the average processing latency of a tuple during clustering and prediction in both Spark and Storm and demonstrated that Spark processes a tuple much quicker than storm on average. Copyright © 2016 John Wiley & Sons, Ltd.

Solaimani, Mohiuddin↗

In vivo kinetics of SARS-CoV-2 infection and its relationship with a person’s infectiousness

Significance Quantifying the kinetics of SARS-CoV-2 infection and individual infectiousness is important for understanding SARS-CoV-2 transmission and evaluating intervention strategies. Here, we developed within-host models of SARS-CoV-2 infection, and by fitting them to clinical data, we estimated key within-host viral dynamic parameters. We also developed a mechanistic model for viral transmission and show that the logarithm of the viral load in the upper respiratory tract serves as an appropriate surrogate for a person’s infectiousness. Using data on how viral load changes during infection, we further evaluated the effectiveness of PCR and antigen-based testing strategies for averting transmission and identifying infected individuals.

60 APPLIED LIFE SCIENCES↗

Advancing Dynamic Modeling of Grid-Connected PV Inverter Using Bi-LSTM-Based AI Model

Power electronic converters (PECs) are widely used in modern power systems to facilitate the interconnection between various AC or DC sources and loads. Because of the extensive integration, the power system has grown into a more dynamic system in which the dynamics of the PECs must be adequately modeled. The paper presents a new bidirectional long short-term memory (Bi-LSTM) method for evaluating grid-connected inverter-based resources (IBR) dynamics. The method is tested using real hardware data from a grid -connected commercial inverter in laboratory experiments. Results show the Bi-LSTM model accurately reproduces the detailed IBR model's dynamics, even when the internal structure is unknown and parameters are unknown, preventing the disclosure of the manufacturer's confidential data.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

An R&D program for milliampere spin-polarized electron beams

The electron injector driving the positron conversion target for Ce+BAF requires a spin-polarized beam with at least 1 mA of average current. While the parameters are not unusual from a beam dynamics point of view, the high average current is challenging due to the finite charge lifetime of the GaAs-based high-polarization photocathodes, even when operated in state-of-the-art load-lock photo-guns. We discuss the dominant limitations and present a systematic experimental program at the Gun Test Stand aiming to overcome them. With a multi-pronged approach involving a redesign of the photo-gun electrodes and an optimized drive laser profile, we hope to demonstrate a charge lifetime in excess of 1 kC from a high-polarization photocathode, mitigating one of the main risks in the injector design.

Bruker, Max [Thomas Jefferson National Accelerator↗

Improved battery parameter estimation method considering operating scenarios for HEV/EV applications

This study presents an improved battery parameter estimation method based on typical operating scenarios in hybrid electric vehicles and pure electric vehicles. Compared with the conventional estimation methods, the proposed method takes both the constant-current charging and the dynamic driving scenarios into account, and two separate sets of model parameters are estimated through different parts of the pulse-rest test. The model parameters for the constant-charging scenario are estimated from the data in the pulse-charging periods, while the model parameters for the dynamic driving scenario are estimated from the data in the rest periods, and the length of the fitted dataset is determined by the spectrum analysis of the load current. In addition, the unsaturated phenomenon caused by the long-term resistor-capacitor (RC) network is analyzed, and the initial voltage expressions of the RC networks in the fitting functions are improved to ensure a higher model fidelity. Simulation and experiment results validated the feasibility of the developed estimation method.

25 ENERGY STORAGE↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Instrumentation development and testing of a wind turbine blade for sub-scale wake studies

Wind turbine blade aerodynamics and the resulting wake flow are complex, and wind tunnel testing of these flows can provide critical insight. The data from such tests are also valuable for validation of numerical models. For experiments using sub-scale turbines to be useful, the blade aerodynamics and wakes must exhibit the important features observed in utility-scale turbine flows. In this work, ~1 m blades designed to produce physics relevant to larger scale turbines were manufactured and affixed to an existing turbine. One of the blades was instrumented for blade surface pressure measurements. Time-dependent surface pressure measurements coupled with instantaneous measurements of the inflow with Cobra probes and the wake with particle image velocimetry allowed for characterization of the inflow, blade flow, and near wake. The results demonstrate that the instrumentation was effective in characterizing the blade loading and the flow field. For the one test case discussed in this paper, the measurements of inflow, blade loading, and wake properties facilitate understanding of the wake's behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Smart Novel Semi-Active Tuned Mass Damper for Fixed-Bottom and Floating Offshore Wind (Paper)

The intention of this paper is to present the results of a novel smart semi-active tuned mass damper (SA-TMD), which mitigates unwanted loads for both fixed-bottom and floating offshore wind systems. The paper will focus on the most challenging water depths for both fixed-bottom and floating systems. A close to 38m Monopile and 55m Tension Leg Platform (TLP) will be considered. A technical development and trade-off analysis will be presented comparing the new system with existing passive non-linear TMD (N-TMD) technology and semi-active. TheSATMD works passively and activates itself with low power source under unwanted dynamic loading in less than 60msec. It is composed of both variable stiffness and damping elements coupled to a central pendulum mass. The analysis has been done numerically in both FAST(NREL) and Orcaflex (Orcina), and integrated in the Wind Turbine system employing CAD/CAE. The results of this work will pave the way for experimental testing to complete the technology qualification process. The load reductions under extreme and fatigue cases reach up significant levels at tower base, consequently reducing LCOE for fixed-bottom to floating wind solutions. The nacelle acceleration is reduced substantially under severe random wind and sea states, reducing the risks of failure of electromechanical components and blades at the rotor nacelle assembly. The SA-TMD system isa new technology that has not been applied previously in wind solutions. Structural damping devices aim to increase offshore wind turbine system robustness and reliability, which eases multiple substructures installations and global stability.

17 WIND ENERGY↗

Development of the TREAT M2 experiment as a transient benchmark

A transient benchmark based on the Transient Reactor Test Facility (TREAT) M2 Calibration experiment (M2-CAL) is under development. TREAT, at Idaho National Laboratory, is a graphite moderated air-cooled research reactor which has been used extensively for fuel material testing under extreme and accident conditions. Accurate benchmark models are a beneficial component in the operations, experimental planning, and development of TREAT. In this work, we present a transient benchmark model for the M2-CAL experiment core loading. The benchmark model incorporates the coupling between the Monte Carlo Code SERPENT and the computational fluid dynamics code OpenFOAM to capture the temperature feedback mechanism. The M2-CAL transient 2580 was simulated in this work. A pre-transient analysis was performed to determine the optimum core composition and conditions before the beginning of the transient. The analysis was validated against historic TREAT kinetic measurements and the worth of the transient rod T-2. The axial power distribution in the flux wire for the M2-CAL experiment was determined and contrasted with the experiment. The model was then used to simulate the M2-CAL transient 2580 experiment based on the reported pre-transient and transient conditions. Several transient observables were calculated and compared to the experiment. The model shows good agreement with the experimental power traces, period, and average increase of power at the power ramp (time > 7.8 s). Inverse point kinetics analysis was performed during the period of the power ramp for the model and the experiment based on that, the temperature feedback component was isolated and contrasted with the experimental feedback. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Distributed Automatic Generation Control Considering DPV Using T&D Dynamic Co-Simulation

The increasing adoption of distributed energy resources (DERs) over the last decade warrants a reconsideration of control of generation resources. This paper proposes a distributed Automatic Generation Control (AGC) using transmission-and-distribution (T&D) dynamic co-simulation framework for the efficient DPV frequency regulation services. The co-simulation framework allows AGC units to exchange the information for distributed AGC, based on their adopted communication network topology. As a result, a cost-effective automatic generation control is achieved with DPV and conventional generators. The proposed distributed AGC is based on the gossip algorithm in which the neighboring AGC units share the relevant local information with each other and updates their share of AGC regulation signal. Distributed photovoltaics (DPV) unit contribute to AGC response based on their headroom capacity via DER aggregators. The algorithm is tested on IEEE-14 bus transmission system under conditions of generation failure and random load variation to observe effective frequency regulations service offered by DPVs and other AGC units. The study shows that DPV can effectively participate in AGC with the proposed distributed control framework.

automatic generation control↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence N - Raw Data

Sequence N: Sin AOA, Rotating (P) This sequence was designed to quantify the blade 3-D unsteady aerodynamic response in the presence of rotational influences by varying blade pitch angle. Test sequence N used an upwind, rigid turbine with a 0° cone angle. The wind speed was 15 m/s, and the yaw angle was 0° throughout the sequence. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. Sinusoidal angle-of-attack histories were designed to emulate 2-D S809 dynamic data obtained at the Ohio State University (OSU) wind tunnel (Reuss Ramsey et al. 1995) and the 1P yawed flow angle-of-attack variations the turbine could be expected to encounter in routine operation. The reduced frequency (K), mean angle of attack (αm), and oscillation amplitude (αω) were computed for each of the five primary span locations. The file lengths varied according to the time required to complete 40 oscillations at the specified frequency. The file name convention used the sequence designation N, followed by two digits for the span location (30, 47, 63, 80, or 95), followed by two digits representing the condition specified in the test matrix, followed by the repetition digit. Due to time constraints, most of the test conditions corresponding to the 63% span location were eliminated. Test points with a static pitch angle of 3° were collected throughout the sequence to ascertain instrumentation fidelity.

17 WIND ENERGY↗

Field Demonstration of Automated Demand Response for Both Winter and Summer Events in Large Buildings in the Pacific Northwest

There are growing strains on the electric grid as cooling peaks grow and equipment ages. Increased penetration of renewables on the grid is also straining electricity supply systems and the need for flexible demand is growing. This paper summarizes results of a series of field test of automated demand response systems in large buildings in the Pacific Northwest. The objective of the research was two fold. One objective was to evaluate the use demand response automation technologies. A second objective was to evaluate control strategies that could change the electric load shape in both winter and summer conditions. Winter conditions focused on cold winter mornings, a time when the electric grid is often stressed. The summer test evaluated DR strategies in the afternoon. We found that we could automate both winter and summer control strategies with the open automated demand response communication standard. The buildings were able to provide significant demand response in both winter and summer events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal mitigation and control over power system dynamics for stochastic grid resilience

Optimal mitigation planning for highly disruptive contingencies to a transmission-level power system requires optimization with dynamic power system constraints, due to the key role of dynamics in system stability to major perturbations. We formulate a generalized disjunctive program to determine optimal grid component hardening choices for protecting against major failures, with differential algebraic constraints representing system dynamics (specifically, differential equations representing generator and load behavior and algebraic equations representing instantaneous power balance over the transmission system). We optionally allow stochastic optimal pre-positioning across all considered failure scenarios, and optimal emergency control within each scenario. This novel formulation allows, for the first time, analyzing the resilience interdependencies of mitigation planning, preventive control, and emergency control. Using all three strategies in concert is particularly effective at maintaining robust power system operation under severe contingencies, as we demonstrate on the western system coordinating council 9-bus test system using synthetic multi-device outage scenarios.

30 DIRECT ENERGY CONVERSION↗

Final Report on CFD and Thermal-Mechanical Stress Analysis of PWR Surge Line under Transient Condition Thermal Stratification and an Evolutionary Cyclic Plasticity Based Transformative Fatigue Evaluation Approach without Using S~N Curve: Rev. 1

This report presents an evolutionary cyclic plasticity based transformative approach for fatigue evaluation of safety critical components. This approach is generic which can be used not only for the present generation light water reactor components (which is our focus) but also for advanced reactor components. The approach is based on the fundamental concept of time-evolution of progressive fatigue damage rather than the end-of-life data based conventional S~N curve approaches. Series of fatigue tests on 316 stainless steel uniaxial specimens were conducted under strain-controlled and stress-controlled cyclic loading in two different environment such as in-air at 300 °C and PWR coolant water condition at 300 °C. Material models are developed to capture the uniaxial test data and are subsequently programmed into commercially available ABAQUS code to transform the uniaxial material behavior to multiaxial loading domain. The developed evolutionary cyclic-plasticity approach is verified by both analytical and 3D-FE modeling of uniaxial fatigue test specimens. Results show that the developed material models can capture the time-dependence of material hardening and softening with great accuracy. In addition, results show that the material models not only can capture the material behavior under constant amplitude loading but also can capture the load-sequence effect under variable and random amplitude loading. The ANL developed approach is one of its kind, which shows first in the fatigue research community that fatigue evaluation of a component (in our case verified for laboratory scale fatigue test specimens with great accuracy) can be performed for its entire fatigue life, including the hardening and softening behavior, without using a conventional S~N curve based approach. Additionally results are presented related to fatigue evaluation of real reactor components such as of a pressurized water reactor (PWR) surge line (SL), under upset transient conditions. SLs of PWR experience complex thermal stratification due to the mixing of differential temperature flow from hot leg and pressurizer. A detailed parametric study of thermal stratification in SL is performed through both standalone computational fluid dynamics (CFD) analysis and fluid-structure-interaction based coupled CFD and heat transfer analysis. Results show that the mass flow rate in SL substantially affects the extent of its thermal stratification. The resulting thermal boundaries conditioned are used as inputs for thermal-mechanical stress analysis and component level fatigue evaluation. Fatigue evaluation of SL pipe under example loading conditions was performed using the above-mentioned evolutionary-plasticity based approach and ASME code (for in-air life) and NUREG-6909 (for PWR environment life) based approaches. Results show that the evolutionary plasticity based approach estimate substantially different life compared to the conventional ASME based approach. To show the entirety of the proposed evolutionary fatigue-modeling framework, this report includes the results presented in semi-annual March report (ANL/LWRS-17/01). Sections 2-5 of March report are directly included as Sections 2-5 in this report, without any significant changes. However, Sections 6-9 of this report present the work performed during March-September of 2017. Whereas, Sections 1 and 10 present the organization of this report and the summary and future work, respectively. This report (ANL/LWRS-17/03 Rev. 1) is a slightly revised version of the earlier published report (ANL/LWRS-17/03). In this revised version, some of the results and associated discussion have been corrected/updated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Large-Scale Molecular Dynamics Simulation Studies on Deformation of Ni Nanowires: Surface Profile, Defects and Stacking Fault Width Analysis

We report large-scale molecular dynamics simulation deformation studies of Ni nanowire (NW) of size 100 Å (x) × 1000 Å (y) × 100 Å (z) comprising of 925,965 atoms. Surface and internal defects are introduced to study their effect on the surface profile, strength, fracture behavior and deformation mechanisms. Tensile tests have been carried out at a temperature of 10 K and at a strain rate of 10{sup 8} s{sup −1}. Periodic boundary condition is applied along the loading direction (y). Peak strength of 23 GPa is observed in the perfect NW, and the strength decreases with defects. The surface profiles of the deformed NWs show intrusion and extrusion regions corresponding to slip steps with wider valleys in the defect NWs. Several intrinsic and extrinsic parallel stacking faults (SFs) are generated after yielding by slip occurring on {111} planes. The calculated SF widths are in the range of 0.85-2.57 nm in the perfect NW. The dislocations are mainly Shockley partial dislocations of type 1/6 〈112〉, and Schmid’s factor (m) obtained is 0.471. Twinning dislocation of types 1/9 〈221〉 and 1/18 〈172〉 is also observed in the SFs. The density of Shockley partial dislocations is observed to be the maximum in all the NWs.

36 MATERIALS SCIENCE↗

Improving the Performance of Integrated Power-Hardware-in-the-Loop and Quasi-Static Time-Series Simulations

This paper introduces a novel multirate cosimulation architecture that overcomes previous challenges integrating faster real-time, microseconds-scale, power-hardware-in-the-loop (PHIL) with larger scale but slower, real-time, seconds-scale, quasi-static time-series (QSTS) simulation. Specifically, an intermediate reduced-equivalent electromagnetic transient (EMT) model duplicates the key power system topology to capture high-speed dynamics and converge hardware-power system interactions between QSTS updates. Exchanging multidimensional parameter vectors (loads, control status, etc.) between the QSTS and EMT models enables capturing the interactions of the rich, high-node-count (thousands of electrical nodes) QSTS model with the hardware. This architecture offers full spatial resolution from QSTS, including individual load dynamics, actual distribution management system controls, and nodal voltages. Simultaneously, the intermediate EMT model provides more detailed high-speed transients of key distributed energy resource hardware interactions. In addition, we use careful PHIL interface design and the exchange of complex power data, rather than current, to further improve performance. This cosimulation architecture is demonstrated by testing a simulated distribution system with an interconnected 500-kVA advanced photovoltaic (PV) inverter in PHIL. In conclusion, the architecture successfully captured PV local volt-volt ampere reactive (volt-VAR) control interactions with the larger network under time-varying electrical and weather conditions.

42 ENGINEERING↗

PDCI Wide-Area Damping Control: PSLF Simulations of the 2017 Test Plan - Light Summer Case

To demonstrate and validate the performance of the wide-area damping control system, the project plans to conduct closed-loop tests on the PDCI in spring/summer 2017. A test plan details the open and closed loop tests to be conducted on the PDCI using the wide-area damping control system. To ensure the appropriate level of preparedness, simulations were performed in order to predict and evaluate any possible unsafe operations before hardware experiments are attempted. This report contains the results from these simulations using the power system dynamics software PSLF (Power System Load Flow, trademark of GE). The simulations use the WECC (Western Electricity Coordinating Council) 2016 light summer and heavy summer base cases and the 2014 dual export base case. Because of the large volume of plots, the results were divided into three reports corresponding to the three base cases. This report contains results from the 2016 light summer base case.

25 ENERGY STORAGE↗

PDCI Wide-Area Damping Control: PSLF Simulations of the 2017 Test Plan - Heavy Summer Case

To demonstrate and validate the performance of the wide-area damping control system, the project plans to conduct closed-loop tests on the PDCI in spring/summer 2017. A test plan details the open and closed loop tests to be conducted on the PDCI using the wide-area damping control system. To ensure the appropriate level of preparedness, simulations were performed in order to predict and evaluate any possible unsafe operations before hardware experiments are attempted. This report contains the results from these simulations using the power system dynamics software PSLF (Power System Load Flow, trademark of GE). The simulations use the WECC (Western Electricity Coordinating Council) 2016 light summer and heavy summer base cases and the 2014 dual export base case. Because of the large volume of plots, the results were divided into three reports corresponding to the three base cases. This report contains results from the 2016 heavy summer base case.

25 ENERGY STORAGE↗