Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Precision Linear Actuator for Space Interferometry Mission (SIM) Siderostat Pointing

'SIM PlanetQuest will exploit the classical measuring tool of astrometry (interferometry) with unprecedented precision to make dramatic advances in many areas of astronomy and astrophysics'(1). In order to obtain interferometric data two large steerable mirrors, or Siderostats, are used to direct starlight into the interferometer. A gimbaled mechanism actuated by linear actuators is chosen to meet the unprecedented pointing and angle tracking requirements of SIM. A group of JPL engineers designed, built, and tested a linear ballscrew actuator capable of performing submicron incremental steps for 10 years of continuous operation. Precise, zero backlash, closed loop pointing control requirements, lead the team to implement a ballscrew actuator with a direct drive DC motor and a precision piezo brake. Motor control commutation using feedback from a precision linear encoder on the ballscrew output produced an unexpected incremental step size of 20 nm over a range of 120 mm, yielding a dynamic range of 6,000,000:1. The results prove linear nanometer positioning requires no gears, levers, or hydraulic converters. Along the way many lessons have been learned and will subsequently be shared.

Cook, Brant↗

Wide-Field Imaging Using Nitrogen Vacancies

Nitrogen vacancies in bulk diamonds and nanodiamonds can be used to sense temperature, pressure, electromagnetic fields, and pH. Unfortunately, conventional sensing techniques use gated detection and confocal imaging, limiting the measurement sensitivity and precluding wide-field imaging. Conversely, the present sensing techniques do not require gated detection or confocal imaging and can therefore be used to image temperature, pressure, electromagnetic fields, and pH over wide fields of view. In some cases, wide-field imaging supports spatial localization of the NVs to precisions at or below the diffraction limit. Moreover, the measurement range can extend over extremely wide dynamic range at very high sensitivity.

Englund, Dirk Robert↗

Method for quantification of porcine type I interferon activity using luminescence, by direct and indirect means

Abstract Background Type I interferons are widely used in research applications and as biotherapeutics. Current assays used to measure interferon concentrations, such as plaque reduction assays and ELISA, are expensive, technically challenging, and may take days to provide results. We sought to develop a robust and rapid assay to determine interferon concentrations produced from transiently transfected cell cultures. Method Indirect quantification of recombinant interferon was evaluated using a novel bi-cistronic construct encoding the Foot-and-mouth disease virus 2A translational interrupter sequence to yield equimolar expression of Gaussia princeps luciferase and porcine interferon α. Direct quantification was evaluated by expression of a novel fusion protein comprised of Gaussia princeps luciferase and porcine type I interferon. Plasmids encoding constructs are transiently transfected into cell cultures and supernatant harvested for testing of luminescence, ELISA determined concentration, and anti-viral activity against vesicular stomatitis virus. Results Bi-cistronic constructs, utilized for indirect quantification, demonstrate both luciferase activity and anti-viral activity. Fusion proteins, utilized for direct quantification, retained secretion and luminescence however only the interferon α fusion protein had antiviral activity comparable to wildtype porcine interferon α. A strong linear correlation was observed between dilution and luminescence for all compounds over a dynamic range of concentrations. Conclusion The correlation of antiviral and luciferase activities demonstrated the utility of this approach, both direct and indirect, to rapidly determine recombinant interferon concentrations. Concentration can be determined over a more dynamic concentration range than available ELISA based assays using this methodology.

59 BASIC BIOLOGICAL SCIENCES↗

Technical Note: Initial characterization of the new EBT-XD Gafchromic film

Purpose: To assess the dosimetric accuracy and energy dependence of the new EBT-eXtended Dose (XD) Gafchromic film and to compare the lateral response artifact (LRA) between EBT-XD and EBT3 film. Methods: EBT3 and EBT-XD calibration curves were created by exposing films to known doses from 0 to 3000 cGy using a 6 MV beam. To assess the accuracy and dynamic range of EBT-XD, a 60° enhanced dynamic wedge (EDW) was used to deliver a dose range of approximately 200–2900 cGy. Comparison to treatment planning system (TPS) calculation was made using a gamma analysis with 2%/2 mm passing criteria. To assess and compare the LRA between EBT3 and EBT-XD, 21 × 21 cm{sup 2} open fields delivered doses of 1000, 2000, and 3000 cGy to both types of film. Films were placed at the center of the scanner, and ratios of measured to TPS predicted doses were calculated at 50 and 80 mm lateral from the scanner center in order to quantitatively assess the LRA. To evaluate the energy dependence of EBT-XD film, seven known doses ranging from 400 to 3000 cGy were delivered using both 6 and 18 MV beams and the resulting optical densities (ODs) compared. Results: The gamma passing rate was 99.1% for the 6 MV EDW delivery. EBT-XD film exhibited minimal LRA (<1%) up to 3000 cGy. In contrast, EBT3 demonstrated an under-response of 11.3% and 22.7% at lateral positions of 50 and 80 mm, respectively, for the 3000 cGy exposure. Differences between ODs of the EBT-XD films exposed to known doses from 6 to 18 MV beams were <0.8% suggesting minimal energy dependence throughout this energy range. Conclusions: The LRA of EBT-XD is greatly reduced when compared to EBT3. This in combination with its accuracy from 0 to 3000 cGy and minimal energy dependence from 6 to 18 MV makes EBT-XD film well suited for dosimetric measurements in high dose SRS/SBRT applications.

60 APPLIED LIFE SCIENCES↗

Generation of constant-amplitude radio-frequency sweeps at a tunnel junction for spin resonance STM

We describe the measurement and successful compensation of the radio-frequency transfer function of a scanning tunneling microscope over a wide frequency range (15.5–35.5 GHz) and with high dynamic range (>50 dB). The precise compensation of cabling resonances and attenuations is critical for the production of constant-voltage frequency sweeps for electric-field driven electron spin resonance (ESR) experiments. We also demonstrate that a well-calibrated tunnel junction voltage is necessary to avoid spurious ESR peaks that can arise due to a non-flat transfer function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of the feasibility of ultraviolet spectrometry for cometary missions

Ultraviolet spectra fo the comet West obtained by sounding rocket experiments in 1976 are reproduced and interpreted in order to estimate the expected brightness of the emission features and determine the spatial extent of these features for the proposed Halley Flyby/Tempel 2 rendezvous and the possible Halley or Encke flybys close to perihelion. A coma model was constructed and evaluated for the physical condition of candidate targets such as heliocentric distance, gas production, and composition. In addition to brightness profiles, the neutral and ion densities of the principal species are also dervied. The brightness profiles can be used to determine the feasibility of utilizing the space telescope to provide supporting observations during the mission. Basic parameters identified are spectral range, wavelength resolution, spatial resolution, sensitivity and dynamic range, rejection of scattered light, and integration or accumulation time.

Feldman, P. D.↗

Composition and structure of the Venus atmosphere - Results from Pioneer Venus

The composition of the Venusian atmosphere was studied using a mass spectrometer on the Pioneer Venus sounder probe. The single-focusing magnetic-sector spectrometer scanned the mass range from hydrogen through mercury with a dynamic range of six decades. Data taken by the mass spectrometer were compared with those of a gas chromatograph, resulting in slight discrepancies due to the use of a sputter ion pump acting as a sink for entry of rare gases through the inlet leak. A surprisingly large concentration of primordial Ar-36 and Ar-38 was discovered in a ratio of 5 to 1. It was concluded that the large excess of primordial argon was a valid result and that the mixing of HCl in the lower Venusian atmosphere was less than a few parts per million. Arguments against the sun as the source for excess primordial gases on Venus were presented. Concentrations of other elements such as Ne, Kr, He, S, and O were discussed. Although the mass peaks in the spectrum were real, it was not clear whether all of the chemical reactions (i.e., COS production) actually occurred in the atmosphere. Until further analysis can be made, it will be uncertain how the inlet system, which is at atmospheric temperature, affected the results.

Hoffman, J. H.↗

Mountain-Top-to-Mountain-Top Optical Link Demonstration

A mountain-top-to-mountain-top optical communications demonstration was conducted between the JPL Table Mountain Facility (TMF), Wrightwood, California, and Strawberry Peak (SP), Lake Arrowhead, California, during the months of August and September of 2000. The link was nearly horizontal at an altitude of 2 km and spanned a range of 46.8 km. A 780-nm multibeam beacon broadcast from TMF was received by the JPL Optical Communications Demonstrator (OCD) located at SP. The received beacon was utilized as a pointing reference to retransmit an 852-nm communications laser beam, modulated at 400 Mb/s by a PN7 pseudo-random bit stream (PRBS) sequence. The long atmospheric path resulted in atmospheric-turbulence-induced angle-of-arrival fluctuations of the beacon at the OCD aperture. A .ne-steering control loop was used to track the resulting beacon centroid motion and update the pointing of the communications laser beam transmitted from SP to TMF. Fried parameters, or r0, inferred from focal spot sizes received at SP were 4 to 5 cm whereas, using the spot sizes received at TMF, they were 2 to 3 cm. In both cases, theory predicts larger r0 values. The predicted angle-of-arrival fluctuations compare well with measured rms displacements exhibited by the focal spots at either end of the link. An uncompensated error of ~1.1 rad in the x-axis and ~2 rad in the y-axis was obtained using centroid data logged by the OCD. Average bit-error rates of 10-5 were recorded for extended periods of time. An atmospheric coherence length r0 of 3 to 5 cm was inferred using the focal-plane spot size measured on the CCD tracking sensor and compared to a predicted value of 5 to 7 cm using reasonable atmospheric models. The irradiance bounds required for the CCD tracking sensor to perform centroiding was found to range from 2000 to 3000 integrated pixel counts, although a more reliable range was 600 to 3000, indicating a dynamic range of 6 to 11 dB. The motion of the spot on the focal plane was also recorded and yielded rms angle-of-arrival-induced focal-plane displacement of 9 to 11 m, compared to a predicted value of 7.8 to 11 m. The irradiance measurements made with the OCD clearly indicate that best tracking performance is obtained when the mean received signal is 2000 to 2200 counts. The best tracking performance resulted in an rms uncompensated error of 1.1 rad. The uncompensated error appeared to increase with either an increase or decrease in mean beacon-signal level. The rms uncompensated error determined by deriving the beacon displacement power spectral density from the beacon centroid-versustime data and the rejection function of the control loop yielded a higher value of 3.4 rad.

Biswas, A.↗

Hysteresis Reduction in Tunneling Magnetoresistive Sensor With AC Modulation Magnetic Field

A simple and practical AC modulation method to reduce the hysteresis in tunneling magnetoresistive sensor is demonstrated. It is shown that with a suitable AC modulation magnetic field that is applied along the sensing direction of TMR sensor, the hysteresis in the sensor can be reduced to a negligible level. And depending on the amplitude of the modulation field, the sensitivity and the dynamic range of the TMR sensor can be tuned to meet practical requirements in specific applications. Here, the influence of the modulation on the noise of TMR sensor is also studied.

42 ENGINEERING↗

Measured daylighting potential of a static optical louver system under real sun and sky conditions

Side-by-side comparisons were made over solstice-to-solstice changes in sun and sky conditions between an optical louver system (OLS) and a conventional Venetian blind set at a horizontal slat angle and located inboard of a south-facing, small-area, clerestory window in a full-scale office testbed. Daylight autonomy (DA), window luminance, and ceiling luminance uniformity were used to assess performance. The performance of both systems was found to have significant seasonal variation, where performance under clear sky conditions improved as maximum solar altitude angles transitioned from solstice to equinox. Although the OLS produced fewer hours per day of DA on average than the Venetian blind, the OLS never exceeded the designated 2000 cd/m2 threshold for window glare. In contrast, the Venetian blind was found to exceed the visual discomfort threshold over a large fraction of the day during equinox conditions. Notably, these peak periods of visual discomfort occurred during the best periods of daylighting performance. Luminance uniformity was analyzed using calibrated high dynamic range luminance images. Under clear sky conditions, the OLS was found to increase the luminance of the ceiling as well as produce a more uniform distribution. Furthermore, compared to conventional venetian blinds, the static optical sunlight redirecting system studied has the potential to significantly reduce the annual electrical lighting energy demand of a daylit space and improve the quality from the perspective of building occupants by consistently transmitting useful daylight while eliminating window glare.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probing the interplay between lattice dynamics and short-range magnetic correlations in CuGeO 3 with femtosecond RIXS

Investigations of magnetically ordered phases on the femtosecond timescale have provided significant insights into the influence of charge and lattice degrees of freedom on the magnetic sub-system. However, short-range magnetic correlations occurring in the absence of long-range order, for example in spin-frustrated systems, are inaccessible to many ultrafast techniques. Here, we show how time-resolved resonant inelastic X-ray scattering (trRIXS) is capable of probing such short-ranged magnetic dynamics in a charge-transfer insulator through the detection of a Zhang–Rice singlet exciton. Utilizing trRIXS measurements at the O K-edge, and in combination with model calculations, we probe the short-range spin correlations in the frustrated spin chain material CuGeO 3 following photo-excitation, revealing a strong coupling between the local lattice and spin sub-systems.

36 MATERIALS SCIENCE↗

Harnessing the power of an X-ray laser for serial crystallography of membrane proteins crystallized in lipidic cubic phase

Serial femtosecond crystallography (SFX) with X-ray free-electron lasers (XFELs) has proven highly successful for structure determination of challenging membrane proteins crystallized in lipidic cubic phase; however, like most techniques, it has limitations. Here we attempt to address some of these limitations related to the use of a vacuum chamber and the need for attenuation of the XFEL beam, in order to further improve the efficiency of this method. Using an optimized SFX experimental setup in a helium atmosphere, the room-temperature structure of the adenosine A 2A receptor (A 2A AR) at 2.0 Å resolution is determined and compared with previous A 2A AR structures determined in vacuum and/or at cryogenic temperatures. Specifically, the capability of utilizing high XFEL beam transmissions is demonstrated, in conjunction with a high dynamic range detector, to collect high-resolution SFX data while reducing crystalline material consumption and shortening the collection time required for a complete dataset. The experimental setup presented herein can be applied to future SFX applications for protein nanocrystal samples to aid in structure-based discovery efforts of therapeutic targets that are difficult to crystallize.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visual Comfort Analysis of Innovative Interior and Exterior Shading Systems for Commercial Buildings using High Resolution Luminance Images

The objective of this study was to explore how calibrated high dynamic range (HDR) images (luminance maps) acquired in real world daylit environments can be used to characterize, evaluate, and compare visual comfort conditions of innovative facade shading and light-redirecting systems. Detailed (1536 x 1536 pixel) luminance maps were time-lapse acquired from two view positions in an unoccupied full scale testbed facility. These maps were analyzed using existing visual comfort metrics to quantify how innovative interior and exterior shading systems compare to conventional systems under real sun and sky conditions over a solstice-to-solstice test interval. The results provide a case study in the challenges and potential of methods of visualizing, evaluating and summarizing daily and seasonal variation of visual comfort conditions computed from large sets of image data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of a fourth-generation focal plane camera for use in plasma-source mass spectrometry

A fourth-generation focal plane camera containing 1696 Faraday-strip detectors was fitted to a Mattauch-Herzog mass spectrograph and characterized for its performance with inductively coupled plasma ionization. The camera provides limits of detection in the single to tens of ng L-1 range for most elements and has a linear dynamic range of at least nine orders of magnitude. Isotope-ratio precision better than 0.02% has also been achieved with this device, and this fourth-generation system features the broadest simultaneous mass range obtainable to date with this family of focal plane camera detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A solid-state converter for measurement of aircraft noise and sonic boom

A solid-state converter, used in a system of instrumentation for measuring aircraft noise and sonic boom, features a dual-gate FET mixer and an output stage designed for compatibility with a zero drive amplifier. With a half-inch condenser microphone the converter itself has an operating frequency range from dc-28 kHz (-3 dB), a dynamic range of 72 dB, and a noise floor of 50 dB in the band from 22.4 Hz to 22.4 kHz; the system requires no impedance matching networks and is insensitive to cable length up to at least 3000 ft.

Zuckerwar, A. J.↗

Unification of X-ray Winds in Seyfert Galaxies: From Ultra-fast Outflows to Warm Absorbers

The existence of ionized X-ray absorbing layers of gas along the line of sight to the nuclei of Seyfert galaxies is a well established observational fact. This material is systematically outflowing and shows a large range in parameters. However, its actual nature and dynamics are still not clear. In order to gain insights into these important issues we performed a literature search for papers reporting the parameters of the soft X-ray warm absorbers (WAs) in 35 type 1 Seyferts and compared their properties to those of the ultra-fast outflows (UFOs) detected in the same sample. The fraction of sources with WAs is >60 per cent, consistent with previous studies. The fraction of sources with UFOs is >34 per cent, >67 per cent of which also show WAs. The large dynamic range obtained when considering all the absorbers together, spanning several orders of magnitude in ionization, column, velocity and distance allows us, for the first time, to investigate general relations among them. In particular, we find significant correlations indicating that the closer the absorber is to the central black hole, the higher the ionization, column, outflow velocity and consequently the mechanical power. In all the cases, the absorbers continuously populate the whole parameter space, with the WAs and the UFOs lying always at the two ends of the distribution. These evidence strongly suggest that these absorbers, often considered of different types, could actually represent parts of a single large-scale stratified outflow observed at different locations from the black hole. The UFOs are likely launched from the inner accretion disc and the WAs at larger distances, such as the outer disc and/or torus. We argue that the observed parameters and correlations are, to date, consistent with both radiation pressure through Compton scattering and magnetohydrodynamic processes contributing to the outflow acceleration, the latter playing a major role. Most of the absorbers, especially the UFOs, show a sufficiently high mechanical power (at least approx 0.5 per cent of the bolometric luminosity) to provide a significant contribution to active galactic nuclei (AGN) feedback and thus to the evolution of the host galaxy. In this regard, we find possible evidence for the interaction of the AGN wind with the surrounding environment on large scales.

Unification↗

Intercomparison of the SNPP and NOAA-20 VIIRS DNB High-Gain Stage Using Observations of Bright Stars

The Visible Infrared Imaging Radiometer Suite (VIIRS) on board the Suomi-NPP (SNPP) and NOAA-20 (N20) spacecrafts is a multi-spectral Earth-observing instrument with bands covering wavelengths from visible to long-wave infrared. Among these bands is a panchromatic day/night band (DNB) with a broad spectral response ranging from 500􀀀900 nm, and a high dynamic range spanning over 7 orders of magnitude, allowing for observations to take place during both daytime and nighttime. The DNB operates at 3 gain levels, with low-, mid- , and high-gain stages. The high-gain stage (HGS) is capable of detecting dim city lights during Earth-view observations at night as well as bright stars through the instrument space-view port. Since SNPP and N20 are at opposite points of the same orbit, each VIIRS instrument is able to observe the same stars with the DNB in successive orbits. This will allow us to make a direct comparison of the relative calibration of each instrument using stars over a range of spectral classes. In this work, we develop methodology for accurately identifying target stars in order to make proper comparisons between the DNB HGS of each instrument. We then take observations from multiple stars in order to compute the ratio in the measured irradiance for each instrument as a function of spectral class. For K-type stars, which have the least spectral change over the DNB wavelength range, we measure a calibration bias between the SNPP and N20 DNB HGS of approximately 4%, which is stable over the duration of the N20 mission.

Truman Wilson↗