Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical connectivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Too Much of a Good Thing? Global Trends in the Curtailment of Solar PV

Solar photovoltaic (PV) systems generate electricity with no marginal costs or emissions. As a result, PV output is almost always prioritized over other fuel sources and delivered to the electric grid. However, PV curtailment is increasing as PV composes greater shares of grid capacity. In this paper, we present a novel synthesis of curtailment in four key countries: Chile, China, Germany, and the United States. We find that about 6.5 million MWh of PV output was curtailed in these countries in 2018. We find that: Policy and grid planning practices influence where, when, and how much PV is curtailed; Some PV curtailment is attributable to limited transmission capacity connecting remote solar resources to load centers; PV curtailment peaks in the spring and fall, when PV output is relatively high but electricity demand is relatively low. We discuss available measures to reduce PV curtailment as well as increasing PV curtailment in the contexts of evolving grids and energy technologies.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High Altitude Electromagnetic Pulse Testing of Photovoltaic Modules

This report details the test setup, process, and results for radiated susceptibility testing of multicrystalline silicon photovoltaic (PV) modules as part of the EMP-Resilient Electric Grid Grand Challenge Laboratory Directed Research and Development (LDRD) project at Sandia National Laboratories. Testing was conducted over October 10-17, 2019, where 8 photovoltaic modules were exposed to E1 transient pulses with peak field levels up to 100 kV/m. Modules were terminated in a resistive load representing connected components. State of health testing conducted via I-V curve tracing of the photovoltaic modules showed no observable loss of device function due to large electric field transients. Differential mode currents were measured on the order of 10's of amps for up to a microsecond following the radiated field pulse. Common mode currents took the form of a damped sinusoid with a maximum peak of 10's to 100's of amps with a resonance near 60 MHz.

14 SOLAR ENERGY↗

Connecting Risk and Resilience for a Power System Using the Portland Hills Fault Case Study

Active seismic faults in the Pacific Northwest area have encouraged electric utilities in the region to deeply contemplate and proactively intervene to support grid resilience. To further this effort this research introduces Monte Carlo (MC)-based power system modeling as a means to inform the Performance Based Earthquake Engineering method and simulates 100,000 sample earthquakes of a 6.8 magnitude (M6.8) Portland Hills Fault (PHF) scenario in the Portland General Electric (PGE) service territory as a proof of concept. This paper also proposes the resilience metric Seismic Load Recovery Factor (SLRF) to quantify the recovery of a downed power system and thus can be used to quantify earthquake economic risk. Using MC results, the SLRF was evaluated to be 19.7 h and the expected economic consequence cost of a M6.8 PHF event was found to be $\$180$ million with an annualized risk of $\$90,000$ given the event’s 1 in 2000 year probability of occurrence. The MC results also identified the eight most consequential substations in the PGE system—i.e., those that contributed to maximum load loss. This paper concludes that retrofitting these substations reduced the expected consequence cost of a M6.8 PHF event to $117 million.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neoclassical transport and profile prediction in transport barriers

Strong gradient regions in tokamaks, such as the pedestal or internal transport barriers, are regions of reduced turbulence where neoclassical transport can play a dominant role. However, standard neoclassical transport theory assumes that the gradient length scales of density, temperature, and potential are of the order of the system size. In the pedestal, gradient length scales are much shorter and are measured to be of the order of the ion poloidal gyroradius. We present an extension of neoclassical theory that is applicable in transport barriers of large aspect ratio tokamaks. We show that particle and momentum transport are connected in such a way that a source of parallel momentum can drive a significant neoclassical ion particle flux. In strong gradient regions, density, electric potential, mean parallel flow, and ion temperature are shown to no longer be flux functions. Instead, they have a small but important poloidally varying piece that modifies the transport equations to lowest order. This introduces a nonlinearity in the transport problem through the coupling with quasineutrality that yields multiple co-existing solutions when solving for the plasma profiles. The different solutions could be connected to low and high transport states and jumps between solutions could provide a new neoclassical explanation for H-L back-transitions.

Trinczek, Silvia [Princeton Plasma Physics Laborat↗

Opportunities for Clean Energy in Natural Gas Well Operations

The oil and gas industry is increasingly seeking operational improvements to reduce both costs and emissions while improving resilience against electric grid outages. This study describes techno-economic analysis of opportunities for distributed energy generation and storage technologies to support companies’ energy cost savings, clean energy, and energy resiliency goals. Specifically, the analysis evaluates solar photovoltaics (PV), distributed wind energy, and battery energy storage at hypothetical upstream well sites in the Marcellus Shale in Pennsylvania, both grid-connected and off-grid. Results indicate opportunity for solar PV to reduce operational costs. Additionally, these technologies reduce the site’s consumption of grid electricity and natural gas and thus can help reduce Scope 1 and 2 emissions associated with electricity and natural gas consumption. For each emissions reduction scenario, a cost of avoided emissions was calculated; these values can be compared to internal organizational value placed on emissions reductions, compared to other emissions reduction strategies such as energy efficiency, reducing flaring, and direct carbon capture and sequestration, and compared to existing (albeit limited) U.S. carbon markets such as California’s Low Carbon Fuel Standard. Results indicate that the associated costs of emissions reductions via distributed renewables are competitive with these options and markets. The study also explores the ability of these electric clean energy technologies to support site resiliency against utility outages.

42 ENGINEERING↗

Opportunities for Clean Energy in Natural Gas Well Operations

The oil and gas industry is increasingly seeking operational improvements to reduce both costs and emissions while improving resilience against electric grid outages. This study describes techno-economic analysis of opportunities for distributed energy generation and storage technologies to support companies' energy cost savings, clean energy, and energy resiliency goals. Specifically, the analysis evaluates solar photovoltaics (PV), distributed wind energy, and battery energy storage at hypothetical upstream well sites in the Marcellus Shale in Pennsylvania, both grid-connected and off-grid. Results indicate opportunity for solar PV to reduce operational costs. Additionally, these technologies reduce the site's consumption of grid electricity and natural gas and thus can help reduce Scope 1 and 2 emissions associated with electricity and natural gas consumption. For each emissions reduction scenario, a cost of avoided emissions was calculated; these values can be compared to internal organizational value placed on emissions reductions, compared to other emissions reduction strategies such as energy efficiency, reducing flaring, and direct carbon capture and sequestration, and compared to existing (albeit limited) U.S. carbon markets such as California's Low Carbon Fuel Standard. Results indicate that the associated costs of emissions reductions via distributed renewables are competitive with these options and markets. The study also explores the ability of these electric clean energy technologies to support site resiliency against utility outages.

42 ENGINEERING↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electric Vehicle Charging Data Falsification Attacks Utilizing Behavioral Models

A charging station (CS) and its associated electric vehicle supply equipment (EVSE) and charging electric vehicle (EV) interactions are potential targets for data falsification attacks since CSs are typically unmanned public facilities that are connected to the internet and EVs incorporate the vulnerable CAN bus network, which are both susceptible to remote attacks. The research question being addressed is how is the EV owner and CS negatively affected by CAN bus EV battery current sensor and battery temperature sensor data falsification attacks. Negative effects include economic losses from reduced life span of the battery, battery thermal runaway and fire (and potential loss of surrounding structure), and reduced utilization of the CS due to delayed departure time (longer charging times).

25 ENERGY STORAGE↗

Characterization of multiterminal tandem photovoltaic devices and their subcell coupling

Three-terminal (3T) and four-terminal (4T) tandem photovoltaic (PV) devices using various materials have been increasingly reported in the literature, but measurement standards are lacking. Here, multiterminal devices measured as functions of two load variables are characterized unambiguously as functions of three device voltages or currents on hexagonal plots. We demonstrate these measurement techniques using two GaInP/GaAs tandem solar cells, with a middle contact between the two subcells, as example 3T devices with both series-connected and reverse-connected subcells. Coupling mechanisms between the subcells are quantified within the context of a simple equivalent optoelectronic circuit. Electrical and optical coupling mechanisms are most clearly revealed using coupled dark measurements. These measurements are sensitive enough to observe very small luminescent coupling from the bottom subcell to the top subcell in the prototype 3T device. Quick simplified measurement techniques are also discussed within the context of the complete characterization.

14 SOLAR ENERGY↗

MaDEVIoT: Cyberattacks on EV Charging Can Disrupt Power Grid Operation

Extensive roll-out of electric vehicles (EVs) requires large-scale deployment of high-power EV Charging Stations (EVCSs). EVCSs are connected to the internet using Internetof- Things (IoT) such as smartphones, to improve the charging experience of users and increase their profitability. This paper studies the feasibility of demand-side cyberattacks launched on power grids via such internet-connected highpower EVCSs. The attack mechanism distorts power grid frequency and voltage, and has the potential to trigger systemwide outages. The case study, based on the power grid and EV deployment plans in Manhattan, New York, illustrates potential impacts of such attacks. The results show that such attacks will become feasible in Manhattan, New York in 2030, as EV adoption increases. Furthermore, the attacks in 2030 are feasible even compromising a single company’s EVCS server in Manhattan, New York. The attacks can cause line overloads and trip over-frequency protection relays, causing system-side blackout in the power grid in Manhattan, New York. The paper informs planning authorities and power grid operators involved with the roll-out of EV charging infrastructure about potential cyberthreats to power grids via manipulating internet-connected high-power EVCSs.

Acharya, Samrat S.↗

Editorial for Special Issue: Grid-Interactive Efficient Buildings - Part 1

We are pleased to present starting with this volume of ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC), a series of peer-reviewed papers related to some of ongoing research projects and applications of Grid-interactive Efficient Buildings (GEBs). As part of a new program initiated by the Building Technology Office (BTO) with the US Department of Energy (DOE), GEBs are characterized as highly energy-efficient buildings that are equipped with smart technologies and distributed energy resources that can be dynamically controlled to meet grid needs and minimize electricity system costs, while meeting occupants’ comfort and productivity requirements. In simple terms,DOE defines GEBs as efficient, connected, smart, and flexible buildings. The GEB technologies touch on the main topical areas of JESBC aimed at fostering sustainable buildings and cities by providing results of evaluation studies and demonstration projects. Indeed, one of the main goals for JESBC is to disseminate solutions to enhance the built environment energy efficiencies, low carbon services, inter-connectivity services, resilient multi-services, and healthy and comfortable living spaces.

buildings↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

SCUC-DER Integration Report: Integrating Distributed Energy Resources (DER) Using Advanced Unit Commitment Models and DER Aggregation Methodologies

Distributed energy resources (DERs) are continuing to grow due to regulatory, policy, and market shifts, and it needs to be ensured that small DERs are given a level playing field with traditional resources. Legacy market processes such as unit-commitment problems were designed for a power grid consisting largely of centralized power plants. In contrast, DERs consist of many small devices with distinct operating characteristics that may or may not be connected at the transmission interconnection points, limiting their visibility to the independent system operators (ISOs) who operate wholesale electricity markets. This report details the development and initial results from a simulation platform that integrates state-of-the-art security-constrained unit commitment software, detailed feeder models, and a DER aggregator model to quantify potential DER integration issues. Quantitative results to date illustrate potential infeasible scheduling solutions from SCUC when the DERA includes aggregations of energy-limited energy storage resources. Likewise, if aggregations are not penalized for dispatch deviations, they may have incentives to deviate from the SCUC-determined resource schedules. Assumptions about the amount of aggregated demand response resources (DRRs) and the ability of DERAs to follow profit incentives have an important impact – DRRs have significant flexibility and can typically feasibly meet their SCUC schedule, but on the other hand, their profit incentives can cause unscheduled increases in load before and after DRR dispatch. Computation time results on the SCUC solver and simulation platform only show a modest increase in SCUC solution time as the number of DERAs is increased, but results to date only reflect the RTS-GMLC test system; results may show more significant solver slowdown in larger transmission systems. The largest contribution to simulation time is attributed to the DERA offer generation method, which is suggested for future improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

H3 Final Design and Technical Report

The goal of this Project was to develop a standards-compliant, fabrication-ready design of Columbia Power Technologies’ (C·Power) next-generation wave energy converter (WEC), the StingRAY H3p. The H3p is a design iteration of C·Power’s StingRAY WEC and is intended for electrical power generation suitable for micro-grids or remote loads. The H3p was designed for grid-connection and at least two years of continuous testing and operation at the proposed PacWave-South (PWS) test site.

16 TIDAL AND WAVE POWER↗

Newberry SHR Demonstration Project – Bipartisan Infrastructure Law Enhanced Geothermal (EGS) Pilot Demonstration (Abstract)

This project will create an Engineered Geothermal System (EGS) comprising two or more wells drilled to a depth of 4.25 km into superhot rock (SHR) with a temperature of 425 °C at Newberry Volcano in Central Oregon. An EGS is a manufactured heat exchanger in which water is injected in a deep injection well, or injector, to extract heat from the hot rock at depth and steam is returned to the surface in a production well, or producer, to generate electricity. In this project, the SHR EGS will be made using new methods and technologies to stimulate and connect hydraulic and natural fractures to enable multiple flow pathways between wells, allowing for optimal heat mining from the reservoir rock. The new technologies are designed to operate at rock temperatures much higher than those encountered in traditional geothermal. Following EGS completion, water will be injected into the injector well and steam extracted from the producer well in a long-term connectivity flow test demonstrating SHR reservoir evolution with time and use. Success will be measured by demonstrating the efficacy of new technologies and by producing economic quantities of steam (>40 MWth).

15 GEOTHERMAL ENERGY↗

Electro-Thermal Characterization of Dynamical VO 2 Memristors via Local Activity Modeling

We report translating the surging interest in neuromorphic electronic components, such as those based on nonlinearities near Mott transitions, into large-scale commercial deployment faces steep challenges in the current lack of means to identify and design key material parameters. These issues are exemplified by the difficulties in connecting measurable material properties to device behavior via circuit element models. Here, the principle of local activity is used to build a model of VO 2 /SiN Mott threshold switches by sequentially accounting for constraints from a minimal set of quasistatic and dynamic electrical and high-spatial-resolution thermal data obtained via in situ thermoreflectance mapping. By combining independent data sets for devices with varying dimensions, the model is distilled to measurable material properties, and device scaling laws are established. The model can accurately predict electrical and thermal conductivities and capacitances and locally active dynamics (especially persistent spiking self-oscillations). The systematic procedure by which this model is developed has been a missing link in predictively connecting neuromorphic device behavior with their underlying material properties, and should enable rapid screening of material candidates before employing expensive manufacturing processes and testing procedures.

36 MATERIALS SCIENCE↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

Visualization of defects in single-crystal and thin-film PdCoO 2 using aberration-corrected scanning transmission electron microscopy

Single-crystal delafossite PdCoO 2 is known to have an extremely low intrinsic impurity concentration of ~0.001%, demonstrating extraordinarily high conductivity with a mean free path of ~20 μm at low temperatures. However, when grown as thin films, the resistivity at room temperature increases by a factor of 3–80 times, depending on the film thickness. Using scanning transmission electron microscopy, we identify different classes of defects for the single crystal vs epitaxial thin film. The dominant defect for single-crystal PdCoO 2 is found to be ribbonlike defects. For the thin films, we identify different types of defects arising in epitaxial thin films mainly due to substrate termination that disrupt the lateral connectivity of the conducting planes. Further, our results are consistent with the high conductivity of single crystals and increased electrical resistivity of the thin films compared to that of single crystals, suggesting that selecting a proper substrate, improving surface quality, and reducing the step density are the keys to enhance the film quality for utilizing PdCoO 2 as a platform for future applications.

36 MATERIALS SCIENCE↗