Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Residual-gas-ionization beam profile monitors in RHIC

Four ionization profile monitors (IPMs) are in RHIC to measure vertical and horizontal beam profiles in the two rings. These work by measuring the distribution of electrons produced by beam ionization of residual gas. During the last two years both the collection accuracy and signal/noise ratio have been improved. An electron source is mounted across the beam pipe from the collector to monitor microchannel plate (MCP) aging and the signal electrons are gated to reduce MCP aging and to allow charge replenishment between single-turn measurements. Software changes permit simultaneous measurements of any number of individual bunches in the ring. This has been used to measure emittance growth rates on six bunches of varying intensities in a single store. Also the software supports FFT analysis of turn-by-turn profiles of a single bunch at injection to detect dipole and quadrupole oscillations.

43 PARTICLE ACCELERATORS↗

Science Requirements and Conceptual Design for a Polarized Medium Energy Electron-Ion Collider at Jlab

Researchers have envisioned an electron-ion collider with ion species up to heavy ions, high polarization of electrons and light ions, and a well-matched center-of-mass energy range as an ideal gluon microscope to explore new frontiers of nuclear science. In its most recent Long Range Plan, the Nuclear Science Advisory Committee (NSAC) of the US Department of Energy and the National Science Foundation endorsed such a collider in the form of a 'half-recommendation.' As a response to this science need, Jefferson Lab and its user community have been engaged in feasibility studies of a medium energy polarized electron-ion collider (MEIC), cost-effectively utilizing Jefferson Lab's already existing Continuous Electron Beam Accelerator Facility (CEBAF). In close collaboration, this community of nuclear physicists and accelerator scientists has rigorously explored the science case and design concept for this envisioned grand instrument of science. An electron-ion collider embodies the vision of reaching the next frontier in Quantum Chromodynamics - understanding the behavior of hadrons as complex bound states of quarks and gluons. Whereas the 12 GeV Upgrade of CEBAF will map the valence-quark components of the nucleon and nuclear wave functions in detail, an electron-ion collider will determine the largely unknown role sea quarks play and for the first time study the glue that binds all atomic nuclei. The MEIC will allow nuclear scientists to map the spin and spatial structure of quarks and gluons in nucleons, to discover the collective effects of gluons in nuclei, and to understand the emergence of hadrons from quarks and gluons. The proposed electron-ion collider at Jefferson Lab will collide a highly polarized electron beam originating from the CEBAF recirculating superconducting radiofrequency (SRF) linear accelerator (linac) with highly polarized light-ion beams or unpolarized light- to heavy-ion beams from a new ion accelerator and storage complex. Since the very beginning, the design studies at Jefferson Lab have focused on achieving high collider performance, particularly ultrahigh luminosities up to 10{sup 34} cm{sup -2}s{sup -1} per detector with large acceptance, while maintaining high polarization for both the electron and light-ion beams. These are the two key performance requirements of a future electron-ion collider facility as articulated by the NSAC Long Range Plan. In MEIC, a new ion complex is designed specifically to deliver ion beams that match the high bunch repetition and highly polarized electron beam from CEBAF. During the last two years, both development of the science case and optimization of the machine design point toward a medium-energy electron-ion collider as the topmost goal for Jefferson Lab. The MEIC, with relatively compact collider rings, can deliver a luminosity above 10{sup 34} cm{sup -2}s{sup -1} at a center-of-mass energy up to 65 GeV. It offers an electron energy up to 11 GeV, a proton energy up to 100 GeV, and corresponding energies per nucleon for heavy ions with the same magnetic rigidity. This design choice balances the scope of the science program, collider capabilities, accelerator technology innovation, and total project cost. An energy upgrade could be implemented in the future by adding two large collider rings housed in another large tunnel to push the center-of-mass energy up to or exceeding 140 GeV. After careful consideration of an alternative electron energy recovery linac on ion storage ring approach, a ring-ring collider scenario at high bunch repetition frequency was found to offer fully competitive performance while eliminating the uncertainties of challenging R&D on ampere-class polarized electron sources and many-pass energy-recovery linacs (ERLs). The essential new elements of an MEIC facility at Jefferson Lab are an electron storage ring and an entirely new, modern ion acceleration and storage complex. For the high-current electron collider ring, the upgraded 12 GeV CEBAF SRF linac will serve as a full-energy injector, and, if needed, provide top-off refilling. The CEBAF fixed-target nuclear physics program can be simultaneously operated since the filling time of the electron ring is very short. The ion complex for MEIC consists of sources for polarized light ions and unpolarized light to heavy ions, an SRF ion linac with proton energy up to 280 MeV, a 3 GeV prebooster synchrotron, a large booster synchrotron for proton energy up to 20 GeV, and a medium-energy collider ring with energy up to 100 GeV. The ion complex can accelerate other species of ions with corresponding energies at each accelerating stage. There are three collision points planned for MEIC. Two of them are for collisions with medium-energy ions; the third is for low energy ion beams stored in a dedicated low-energy compact storage ring, as a possible follow-on project.

43 PARTICLE ACCELERATORS↗

Synthesis of bismuth tungstate (Bi{sub 2}WO{sub 6}) nanoflakes and their field emission investigation

The nanoflakes of Bismuth Tungstate (Bi{sub 2}WO{sub 6}) were successfully synthesized by a one-step facile hydrothermal route without using any templates or surfactants and field emission investigations of the Bi{sub 2}WO{sub 6} nanoflakes emitter are reported. Structural and morphological analysis of as-synthesized Bi{sub 2}WO{sub 6} nanoflakes has been carried out using X-ray diffraction (XRD) and scanning electron microscope (SEM). Moreover, the field emission characteristics of the Bi{sub 2}WO{sub 6} nanoflakes are found to be superior to the other semiconductor emitters. The synthesized Bi{sub 2}WO{sub 6} nanoflakes emitter delivers current density of ~222.35 μA/cm{sup 2} at an applied electric field of ~7.2 V/μm. The emission current stability investigated at pre-set value of ~2 μA is observed to be fairly good. These observed results demonstrate potential candidate of the Bi{sub 2}WO{sub 6} cathode as an electron source for practical applications in vacuum microelectronic device.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Robust RF Photocathodes (Phase II Final Report)

This program addressed requirements for photocathodes with high quantum efficiency (QE) and long lifetimes. Currently, photocathodes with QEs above 1% exhibit lifetimes measured in a few hours. This is unacceptable for commercial devices using photocathodes as the electron source. This includes accelerators for industrial, medical, defense, and educational applications as well as emerging applications, such as time resolved electron microscopy. Calabazas Creek Research, Inc. (CCR) and the University of Maryland (UMD) attempted to develop reservoir photocathodes that dramatically increased lifetime and increased the ability to recover from contaminating events, such as loss of system vacuum. The Phase I program demonstrated the viability of the reservoir approach for higher QE cathodes. The Phase II program focused on design, fabrication, and delivery. This included increasing understanding of photocathode physics, investigating design options, addressing performance issues, and developing fabrication and packaging techniques leading to commercial products. The initial task identified specific photocathode materials that provide high QE and are compatible with the reservoir approach. The goal was that these photocathodes be manufacturable in a production environment, understanding that the “environment” is highly specialized. The photocathode geometry was modified to address several photogun performance issues related primarily to emittance. A goal was to reduce or eliminate thermal emittance issues arising from the reservoir heater. The program developed fabrication, handling, and transport techniques and facilities to allow commercial photocathode production for certain materials. Not only was complex chemistry involved, but practical issues of transporting and installing the cathodes into user systems were addressed. A critical goal was demonstration of reservoir photocathodes in operating RF guns, where performance could be directly measured. Success depended on clear demonstration that the cathodes could be produced, delivered, installed, and provide the required performance. The principal effort in this program was to develop reservoir cesium antimonide photocathodes. Cesium antimonide cathodes provide a work function in excess of the 1% goal, while the current generation exhibits lifetimes measured in hours. The reservoir in CCRs’ controlled porosity reservoir (CPR) cathodes provides a mechanism for replacing cesium evaporating from the surface by transporting replacement cesium from the reservoir. This is accomplished by gently heating the reservoir to induce cesium diffusion through micron-scale pores in the reservoir cap and photocathode emitter. Experiments at the UMD determined that cesium diffused from the reservoir would only react with antimony on the surface if the temperature exceeded 300C. At this temperature, however, the surface cesium evaporated faster than it could be replenished from the reservoir. Consequently, the QE decreased each time recessiation was attempted. This appears to be a fundamental problem with this approach. The sections below provide information on accomplishments for each task in the program. Once the issue with cesium antimonide cathodes was identified, CCR refocused the program to begin investigation of graphene coated photocathodes in collaboration with SLAC National Accelerator Laboratory (SLAC). The photocathode test chamber developed in the program was transferred to SLAC for use in the graphene research. This is described below in a task added to the program.

43 PARTICLE ACCELERATORS↗

High-intensity polarized electron gun featuring distributed Bragg reflector GaAs photocathode

The polarized electron source is a critical component in accelerator facilities such as the electron–ion collider, which requires a polarized electron gun with higher voltage and higher bunch charge than existing sources. One challenge we faced was the surface charge limit of the distributed Bragg reflector GaAs/GaAsP superlattice (DBR-SL-GaAs) photocathode. We suppressed this effect by optimizing the surface doping and heat cleaning procedures. We achieved up to 11.6 nC bunch charge of polarized electron beam. In this report, we discuss the performance of tests of a DBR-SL-GaAs photocathode in the high voltage direct current gun. Possible reasons for the observed peak quantum efficiency wavelength shift are analyzed, and we addressed it by using a wavelength tunable laser. In addition, the impact of the DBR layer and laser on the lifetime is investigated in this paper. The optimal DBR-SL-GaAs operating zone has been proposed, which gave us a long lifetime and high polarization at 30 μA operation. Finally, the success of this polarized gun will be key to the future of the nuclear sciences.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of target irradiation and diagnostic chamber to study ps-laser generated plasma as a source of singly charged ions for external injection into an electron beam ion source

High repetition-rate (~10 kHz) ps-lasers are becoming available on the market with reasonable cost and may offer several advantages compared to ns-lasers by generating nearly continuous beams of singly charged ions appropriate for the “slow” injection mode into the Electron Beam Ion Source (EBIS). To evaluate these advantages, we will perform studies of a ps-laser generated plasma using a laser with a pulse duration of 8 ps and energy up to 5 mJ per pulse. A vacuum chamber equipped with a 3D target positioner, a focusing lens, and a Faraday Cup has been designed and built for this study. Lens-to-target distance variations have been measured using a laser tracker over the whole range of horizontal and vertical translation for all five targets we will use. The variations were found to be within ±150 µm. This level of “target flatness” should be acceptable for our experimental conditions. Ion currents and ion pulse durations of various elements (from Al to Ta) will be measured for different target irradiation conditions (focal spot size and laser pulse energy). The results obtained will allow us to specify all parameters and geometry of a laser ion source based on a ps-laser to provide external ion injection into the relativistic heavy ion collider EBIS

43 PARTICLE ACCELERATORS↗

Note: Portable rare-earth element analyzer using pyroelectric crystal

We report a portable rare-earth element analyzer with a palm-top size chamber including the electron source of a pyroelectric crystal and the sample stage utilizing cathodoluminescence (CL) phenomenon. The portable rare-earth element analyzer utilizing CL phenomenon is the smallest reported so far. The portable rare-earth element analyzer detected the rare-earth elements Dy, Tb, Er, and Sm of ppm order in zircon, which were not detected by scanning electron microscopy-energy dispersive X-ray spectroscopy analysis. We also performed an elemental mapping of rare-earth elements by capturing a CL image using CCD camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-278: Realization of Dose Verification Tool for IMRT Plan Based On DPM

Purpose: To build a Monte Carlo dose verification tool for IMRT Plan by implementing a irradiation source model into DPM code. Extend the ability of DPM to calculate any incident angles and irregular-inhomogeneous fields. Methods: With the virtual source and the energy spectrum which unfolded from the accelerator measurement data,combined with optimized intensity maps to calculate the dose distribution of the irradiation irregular-inhomogeneous field. The irradiation source model of accelerator was substituted by a grid-based surface source. The contour and the intensity distribution of the surface source were optimized by ARTS (Accurate/Advanced Radiotherapy System) optimization module based on the tumor configuration. The weight of the emitter was decided by the grid intensity. The direction of the emitter was decided by the combination of the virtual source and the emitter emitting position. The photon energy spectrum unfolded from the accelerator measurement data was adjusted by compensating the contaminated electron source. For verification, measured data and realistic clinical IMRT plan were compared with DPM dose calculation. Results: The regular field was verified by comparing with the measured data. It was illustrated that the differences were acceptable (<2% inside the field, 2–3mm in the penumbra). The dose calculation of irregular field by DPM simulation was also compared with that of FSPB (Finite Size Pencil Beam) and the passing rate of gamma analysis was 95.1% for peripheral lung cancer. The regular field and the irregular rotational field were all within the range of permitting error. The computing time of regular fields were less than 2h, and the test of peripheral lung cancer was 160min. Through parallel processing, the adapted DPM could complete the calculation of IMRT plan within half an hour. Conclusion: The adapted parallelized DPM code with irradiation source model is faster than classic Monte Carlo codes. Its computational accuracy and speed satisfy the clinical requirement, and it is expectable to be a Monte Carlo dose verification tool for IMRT Plan. Strategic Priority Research Program of the China Academy of Science(XDA03040000); National Natural Science Foundation of China (81101132)

60 APPLIED LIFE SCIENCES↗

Dynamics of Longitudinal Phase-Space Modulations in an rf Compressor for Electron Beams

Free Electron Lasers (FELs) operating in the UV or x-ray radiation spectrum require peak beam currents that are generally higher than those obtainable by present electron sources, thus making bunch compression necessary. Compression, however, may heighten the effects of collective forces and degrade the beam quality. In this paper they provide a framework for investigating some of these effects in rf compressors by focusing on the longitudinal dynamics of small-amplitude density perturbations, which have the potential to cause the disruptive appearance of the so-called microbunching instability. They develop a linear theory valid for low-to-moderate compression factors under the assumption of a 1D impedance model of longitudinal space charge and provide validation against macroparticle simulations.

43 PARTICLE ACCELERATORS↗

High Intensity Polarized Electron Gun Studies at MIT-Bates

A proposed new high-luminosity electron-ion collider requires a polarized electron source of extremely high intensity. An ion back bombardment of the cathode is the main factor limiting the intensity of modern polarized electron guns. This study examines the possibility of building a very high intensity polarized electron gun.

43 PARTICLE ACCELERATORS↗

Concept for a fourth generation electron cyclotron resonance ion source

A fourth generation electron cyclotron resonance ion source with an operating frequency between 40 and 56 GHz has the potential to quadruple the heavy-ion beam currents and provide a cost effective upgrade path for heavy ion drivers in use or in the planning stage at radioactive beam facilities. Design studies show it is feasible to produce the required magnetic fields in the plasma chamber, 7 T axially and 4 T in the radial direction with a magnetic structure using commercially available Nb{sub 3}Sn superconducting materials. In this paper we describe the design of such a magnet structure including a 3D analysis of the Lorentz forces generated by the magnetic fields and the necessary clamping structure to stabilize the conductor against these forces.

43 PARTICLE ACCELERATORS↗

PHYSICS RESULTS OF THE NSLS-II LINAC FRONT END TEST STAND

The Linac Front End Test Stand (LFETS) was installed at the Source Development Laboratory (SDL) in the fall of 2011 in order to test the Linac Front End. The goal of these tests was to test the electron source against the specifications of the linac. In this report, we discuss the results of these measurements and the effect on linac performance.

43 PARTICLE ACCELERATORS↗

Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay

One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

43 PARTICLE ACCELERATORS↗

Effect of activation temperature on quantum efficiency and lifetime of NEA truncated nanocone array GaAs photocathode

This study investigates the quantum efficiency (QE) and operational lifetime of a negative electron affinity GaAs truncated nanocone array (TNCA) photocathode benchmarked against a conventional flat GaAs photocathode under varying activation temperatures. The TNCA structure demonstrated a QE of up to 13.6% at 590 nm with room temperature (RT) activation—approximately 1.5 times higher than its flat counterpart. This enhancement is due to Mie resonance effects within the nanostructure, as confirmed by finite-difference time-domain simulations. Moreover, the TNCA photocathode exhibits significantly extended charge lifetime, with enhancement factors of ∼6.1 and ∼19.8 under RT and 50 °C activations, respectively. These gains are primarily attributed to increased effective surface area and optimized dipole layer formation at elevated temperatures. In addition, shorter excitation wavelengths further contribute to lifetime improvements. These findings underscore the TNCA GaAs photocathode’s potential as a high QE, long lifetime electron source for many large-scale electron accelerators.

Cs-NF3 activation↗

One-step model of photoemission from single-crystal surfaces

In our paper, we present a three-dimensional one-step photoemission model that can be used to calculate the quantum efficiency and momentum distributions of electrons photoemitted from ordered single-crystal surfaces close to the photoemission threshold. Using Ag(111) as an example, we also show that the model can not only calculate the quantum efficiency from the surface state accurately without using any ad hoc parameters, but also provides a theoretical quantitative explanation of the vectorial photoelectric effect. This model in conjunction with other band structure and wave function calculation techniques can be effectively used to screen single-crystal photoemitters for use as electron sources for particle accelerator and ultrafast electron diffraction applications.

36 MATERIALS SCIENCE↗

Electron diffraction using ultrafast electron bunches from a laser-wakefield accelerator at kHz repetition rate

We show that electron bunches in the 50-100 keV range can be produced from a laser wakefield accelerator using 10 mJ, 35 fs laser pulses operating at 0.5 kHz. It is shown that using a solenoid magnetic lens, the electron bunch distribution can be shaped. The resulting transverse and longitudinal coherence is suitable for producing diffraction images from a polycrystalline 10 nm aluminum foil. The high repetition rate, the stability of the electron source, and the fact that its uncorrelated bunch duration is below 100 fs make this approach promising for the development of sub-100 fs ultrafast electron diffraction experiments.

43 PARTICLE ACCELERATORS↗

Improved charge breeding efficiency of light ions with an electron cyclotron resonance ion source

The Californium Rare Isotope Breeder Upgrade is a new radioactive beam facility for the Argonne Tandem Linac Accelerator System (ATLAS). The facility utilizes a {sup 252}Cf fission source coupled with an electron cyclotron resonance ion source to provide radioactive beam species for the ATLAS experimental program. The californium fission fragment distribution provides nuclei in the mid-mass range which are difficult to extract from production targets using the isotope separation on line technique and are not well populated by low-energy fission of uranium. To date the charge breeding program has focused on optimizing these mid-mass beams, achieving high charge breeding efficiencies of both gaseous and solid species including 14.7% for the radioactive species {sup 143}Ba{sup 27+}. In an effort to better understand the charge breeding mechanism, we have recently focused on the low-mass species sodium and potassium which up to present have been difficult to charge breed efficiently. Unprecedented charge breeding efficiencies of 10.1% for {sup 23}Na{sup 7+} and 17.9% for {sup 39}K{sup 10+} were obtained injecting stable Na{sup +} and K{sup +} beams from a surface ionization source.

43 PARTICLE ACCELERATORS↗

Refractory rf ovens and sputter probes for electron cyclotron resonance ion source

Beams from electron cyclotron resonance ion source (ECRIS) with radio frequency ovens for refractory material (using a Mo coil) were recently demonstrated; results for Ti and V are here discussed, with temperature T{sub s}{>=}2300 K stably maintained and extracted current of about 1000 nA for V{sup 8+} and V{sup 9+}. The status of sputter probes is also reported, and the reason why trapping efficiency may be lower than in the oven case are investigated. The simple tubular probe concept show typical currents of Sn{sup 18+} about 250 nA, for the most abundant isotopes, but an operating pressure of about 300 {mu}Pa may be required. Some preliminary experiments were performed with Penning probes, showing that transmission of Sn or Pr from Penning cathode to ECRIS plasma is limited. Placement of tin onto anticathode and use of collimator between Penning and ECRIS are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗