Search NASA⌕ Search

SEARCH · Search NASA

Results for “error bars”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Studies of sigma(e+ e- to hadrons) at BaBar using Initial State Radiation (ISR)

We present a review of BaBar results on e{sup +}e{sup -} {yields} hadrons using the initial state radiation technique. Cross sections over the {radical}s range from threshold to 4-5 GeV, with very small point-to-point systematic errors, are presented for the {pi}{sup +}{pi}{sup -}{pi}{sup 0}, 2({pi}{sup +}{pi}{sup -}), 2(K{sup +}K{sup -}), 3({pi}{sup +}{pi}{sup -}), 2({pi}{sup +}{pi}{sup -})2{pi}{sup 0}, 2({pi}{sup +}{pi}{sup -})K{sup +}K{sup -}, and p{bar p} final states. The preliminary results of e{sup +}e{sup -} {yields} K{sup +}K{sup -}{pi}{sup +}{pi}{sup -} and e{sup +}e{sup -} {yields} K{sup +}K{sup -}{pi}{sup 0}{pi}{sup 0} cross sections are also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical determination of bulk flow motions

We present here a new parameterization for the bulk motions of galaxies and clusters (in the linear regime) that can be measured statistically from the shape and amplitude of the two-dimensional two-point correlation function. We further propose the one-dimensional velocity dispersion (v{sub p}) of the bulk flow as a complementary measure of redshift-space distortions, which is model-independent and not dependent on the normalisation method. As a demonstration, we have applied our new methodology to the C4 cluster catalogue constructed from Data Release Three (DR3) of the Sloan Digital Sky Survey. We find v{sub p} = 270{sup +433} km/s (also consistent with v{sub p} = 0) for this cluster sample (at z-bar = 0.1), which is in agreement with that predicted for a WMAP5-normalised ΛCDM model (i.e., v{sub p}(ΛCDM) = 203 km/s). This measurement does not lend support to recent claims of excessive bulk motions ( ≅ 1000 km/s) which appear in conflict with ΛCDM, although our large statistical error cannot rule them out. From the measured coherent evolution of v{sub p}, we develop a technique to re-construct the perturbed potential, as well as estimating the unbiased matter density fluctuations and scale-independent bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Quartz conditioning crystal for X-ray rocking curve topography

A large α-quartz crystal designed to condition the monochromatic beam at beamline 1-BM of the Advanced Photon Source is presented. The purpose of this crystal was to provide a precise match to the Bragg angle of quartz crystals that are commonly used to make analyzers for plasma diagnostics. In order to characterize these analyzers, area detectors need to be positioned at distances from the analyzer at upwards of 1000 mm. As a result of this precise matching, a Bragg-reflected beam from such an analyzer is precisely parallel to the beam incident on the conditioning crystal. This situation alleviates the need to adjust the position of the area detector as the distance between the analyzer and the area detector is varied. That is, there is no need to account for vertical displacement of the diffracted-beam image as a function of this distance. Additionally, verification that the analyzer is set to the correct Bragg reflection is obtained by scanning this distance, because only for a spurious reflection will there be a vertical displacement. This is a very useful check. To commission the conditioning crystal, diffraction from a high-quality flat quartz crystal was mapped using a CCD. Bragg diffraction from the 40$\bar{40}$ reflection at 8.5 keV was studied over an area of 23 × 31 mm. The theoretical Darwin width of the flat sample in this case was 4.7 µrad. An FWHM value near 6 µrad was measured over almost the entire mapped area. These data demonstrate that the resolution function for this four-crystal arrangement is ~4 µrad. Data are also presented for a 0.1 mm-thick α-quartz wafer pressed into a concave form, having a nominal radius of 500 mm and intended for use as an analyzer. Because analyzers are bent crystals, diffraction occurs in narrow bands. When a multiple exposure is made as a function of rocking angle a striped pattern is obtained, which is commonly referred to as a zebra-stripe pattern. A series of zebra stripes from the 30$\bar{33}$ Bragg reflection of the bent wafer over its 25 mm-diameter area were recorded on a CCD. The zebra-stripe pattern was analyzed to show a uniform bending to a radius of 497.0 ± 0.3 mm, in support of the nominal value. An r.m.s. slope error of 7 µrad was also obtained from this analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device

Purpose: Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy of this device for the purpose of mouse brain irradiation. Methods: A mouse head holder was designed for a microCT couch using CAD software and printed in an acrylic based material. Ten mice received half-brain radiation while positioned in the 3D-printed head holder. Animal placement was achieved using on-board image guidance and computerized asymmetric collimators. To evaluate the precision of beam localization for half-brain irradiation, mice were sacrificed approximately 30 min after treatment and brain sections were stained for γ-H2AX, a marker for DNA breaks. The distance and angle of the γ-H2AX radiation beam border to longitudinal fissure were measured on histological samples. Animals were monitored for any possible trauma from the device. Results: Visualization of the radiation beam on ex vivo brain sections with γ-H2AX immunohistochemical staining showed a sharp radiation field within the tissue. Measurements showed a mean irradiation targeting error of 0.14 ± 0.09 mm (standard deviation). Rotation between the beam axis and mouse head was 1.2° ± 1.0° (standard deviation). The immobilization device was easily adjusted to accommodate different sizes of mice. No signs of trauma to the mice were observed from the use of tooth block and ear bars. Conclusions: The authors designed and built a novel 3D-printed mouse head holder with many desired features for accurate and reproducible radiation targeting. The 3D printing technology was found to be practical and economical for producing a small animal imaging and radiation restraint device and allows for customization for study specific needs.

60 APPLIED LIFE SCIENCES↗

Precision measurement of the top quark mass in the lepton + jets channel using a matrix element method with Quasi-Monte Carlo integration

This thesis presents a measurement of the top quark mass obtained from p$\bar{p}$ collisions at √s = 1.96 TeV at the Fermilab Tevatron using the CDF II detector. The measurement uses a matrix element integration method to calculate a t$\bar{t}$ likelihood, employing a Quasi-Monte Carlo integration, which enables us to take into account effects due to finite detector angular resolution and quark mass effects. We calculate a t$\bar{t}$ likelihood as a 2-D function of the top pole mass m t and Δ JES , where Δ JES parameterizes the uncertainty in our knowledge of the jet energy scale; it is a shift applied to all jet energies in units of the jet-dependent systematic error. By introducing Δ JES into the likelihood, we can use the information contained in W boson decays to constrain Δ JES and reduce error due to this uncertainty. We use a neural network discriminant to identify events likely to be background, and apply a cut on the peak value of individual event likelihoods to reduce the effect of badly reconstructed events. This measurement uses a total of 4.3 fb -1 of integrated luminosity, requiring events with a lepton, large E T , and exactly four high-energy jets in the pseudorapidity range |η| < 2.0, of which at least one must be tagged as coming from a b quark. In total, we observe 738 events before and 630 events after applying the likelihood cut, and measure m t = 172.6 ± 0.9 (stat.) ± 0.7 (JES) ± 1.1 (syst.) GeV/c 2 , or m t = 172.6 ± 1.6 (tot.) GeV/c 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Branching Fraction Measurement of B to omega l nu decays

We present a measurement of the B{sup +} {yields} {omega}{ell}{sup +}{nu} branching fraction based on a sample of 467 million B{bar B} pairs recorded by the BABAR detector at the SLAC PEP-II e{sup +}e{sup -} collider. We observe 1041 {+-} 133 signal decays, corresponding to a branching fraction of {Beta}(B{sup +} {yields} {omega}{ell}{sup +}{nu}) = (1.15 {+-} 0.15 {+-} 0.12) x 10{sup -4}, where the first error is statistical and the second is systematic. The dependence of the decay rate on q{sup 2}, the momentum transfer squared to the lepton system, is compared to QCD predictions of the form factors based on a quark model and light-cone sum rules.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A measurement of CMB cluster lensing with SPT and DES year 1 data

Clusters of galaxies gravitationally lens the cosmic microwave background (CMB) radiation, resulting in a distinct imprint in the CMB on arcminute scales. Measurement of this effect offers a promising way to constrain the masses of galaxy clusters, particularly those at high redshift. We use CMB maps from the South Pole Telescope Sunyaev-Zel'dovich (SZ) survey to measure the CMB lensing signal around galaxy clusters identified in optical imaging from first year observations of the Dark Energy Survey. The cluster catalog used in this analysis contains 3697 members with mean redshift of $\bar{z} = 0.45$. We detect lensing of the CMB by the galaxy clusters at $8.1\sigma$ significance. Using the measured lensing signal, we constrain the amplitude of the relation between cluster mass and optical richness to roughly $17\%$ precision, finding good agreement with recent constraints obtained with galaxy lensing. The error budget is dominated by statistical noise but includes significant contributions from systematic biases due to the thermal SZ effect and cluster miscentering.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation and study of baryonic B decays: B -> D(*) p pbar, D(*) p pbar pi, and D(*) p pbar pi pi

We present a study of ten B-meson decays to a D{sup (*)}, a proton-antiproton pair, and a system of up to two pions using BABAR's data set of 455 x 10{sup 6} B{bar B} pairs. Four of the modes {bar B}{sup 0} {yields} D{sup 0}p{bar p}, {bar B}{sup 0} {yields} D*{sup 0}p{bar p}, {bar B}{sup 0} {yields} D{sup +}p{bar p}{pi}{sup -}, {bar B}{sup 0} {yields} D{sup ast+}p{bar p}{pi}{sup -} are studied with improved statistics compared to previous measurements; six of the modes (B{sup -} {yields} D{sup 0}p{bar p}{pi}{sup -}, B{sup -} {yields} D*{sup 0}p{bar p}{pi}{sup -}, {bar B}{sup 0} {yields} D{sup 0}p{bar p}{pi}{sup -}{pi}{sup +}, {bar B}{sup 0} {yields} D*{sup 0}p{bar p}{pi}{sup -}{pi}{sup +}, B{sup -} {yields} D{sup +}p{bar p}{pi}{sup -}{pi}{sup -}, B{sup -} {yields} D{sup ast+}p{bar p}{pi}{sup -}{pi}{sup -}) are first observations. The branching fractions for 3- and 5-body decays are suppressed compared to 4-body decays. Kinematic distributions for 3-body decays show non-overlapping threshold enhancements in m(p{bar p}) and m(D{sup (*)0}p) in the Dalitz plots. For 4-body decays, m(p{pi}{sup -}) mass projections show a narrow peak with mass and full width of (1497.4 {+-} 3.0 {+-} 0.9)MeV/c{sup 2} and (47 {+-} 12 {+-} 4)MeV/c{sup 2}, respectively, where the first (second) errors are statistical (systematic). For 5-body decays, mass projections are similar to phase space expectations. All results are preliminary.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPACE VELOCITIES OF SOUTHERN GLOBULAR CLUSTERS. VII. NGC 6397, NGC 6626 (M28), AND NGC 6656 (M22)

We have measured the absolute proper motions of globular clusters NGC 6397, NGC 6626 (M22), and NGC 6656 (M28) as part of our ongoing Southern Proper-Motion Program. The reference system is the ICRS via Hipparcos stars for these three low-Galactic-latitude clusters. Formal errors range between {approx}0.3 and 0.7 mas yr{sup -1}. Notable is the result for NGC 6397, which differs by 2.5 mas yr{sup -1} from two Hubble Space Telescope determinations while agreeing with previous ground-based ones. We determine orbits for all three clusters in an axisymmetric and barred model of the Galaxy and discuss these in the context of globular-cluster formation. M22 is a well-known cluster with an iron abundance spread; such clusters are now believed to have formed in massive parent systems that can retain ejecta of core-collapsed supernovae. We find that the five currently accepted globular clusters with iron/calcium abundance spread show orbits unrelated to each other, thus suggesting at least five independent, massive progenitors that have contributed to the build-up of the Milky-Way halo.

79 ASTRONOMY AND ASTROPHYSICS↗

Integration and evaluation of a needle-positioning robot with volumetric microcomputed tomography image guidance for small animal stereotactic interventions

Purpose: Preclinical research protocols often require insertion of needles to specific targets within small animal brains. To target biologically relevant locations in rodent brains more effectively, a robotic device has been developed that is capable of positioning a needle along oblique trajectories through a single burr hole in the skull under volumetric microcomputed tomography (micro-CT) guidance. Methods: An x-ray compatible stereotactic frame secures the head throughout the procedure using a bite bar, nose clamp, and ear bars. CT-to-robot registration enables structures identified in the image to be mapped to physical coordinates in the brain. Registration is accomplished by injecting a barium sulfate contrast agent as the robot withdraws the needle from predefined points in a phantom. Registration accuracy is affected by the robot-positioning error and is assessed by measuring the surface registration error for the fiducial and target needle tracks (FRE and TRE). This system was demonstrated in situ by injecting 200 {mu}m tungsten beads into rat brains along oblique trajectories through a single burr hole on the top of the skull under micro-CT image guidance. Postintervention micro-CT images of each skull were registered with preintervention high-field magnetic resonance images of the brain to infer the anatomical locations of the beads. Results: Registration using four fiducial needle tracks and one target track produced a FRE and a TRE of 96 and 210 {mu}m, respectively. Evaluation with tissue-mimicking gelatin phantoms showed that locations could be targeted with a mean error of 154{+-}113 {mu}m. Conclusions: The integration of a robotic needle-positioning device with volumetric micro-CT image guidance should increase the accuracy and reduce the invasiveness of stereotactic needle interventions in small animals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of CP observables in B{sup {+-}{yields}D}{sub CP}K{sup {+-}}decays and constraints on the CKM angle {gamma}

Using the entire sample of 467x10{sup 6} {Upsilon}(4S){yields}BB decays collected with the BABAR detector at the PEP-II asymmetric-energy B factory at the SLAC National Accelerator Laboratory, we perform an analysis of B{sup {+-}}{yields}DK{sup {+-}}decays, using decay modes in which the neutral D meson decays to either CP-eigenstates or non-CP-eigenstates. We measure the partial decay rate charge asymmetries for CP-even and CP-odd D final states to be A{sub CP+}=0.25{+-}0.06{+-}0.02 and A{sub CP-}=-0.09{+-}0.07{+-}0.02, respectively, where the first error is the statistical and the second is the systematic uncertainty. The parameter A{sub CP+} is different from zero with a significance of 3.6 standard deviations, constituting evidence for direct CP violation. We also measure the ratios of the charged-averaged B partial decay rates in CP and non-CP decays, R{sub CP+}=1.18{+-}0.09{+-}0.05 and R{sub CP-}=1.07{+-}0.08{+-}0.04. We infer frequentist confidence intervals for the angle {gamma} of the unitarity triangle, for the strong phase difference {delta}{sub B}, and for the amplitude ratio r{sub B}, which are related to the B{sup -}{yields}DK{sup -} decay amplitude by r{sub B}e{sup i({delta}{sub B}-{gamma})}=A(B{sup -}{yields}D{sup 0}K{sup -})/A(B{sup -}{yields}D{sup 0}K{sup -}). Including statistical and systematic uncertainties, we obtain 0.24<r{sub B}<0.45 (0.06<r{sub B}<0.51) and, modulo 180 deg., 11.3 deg. <{gamma}<22.7 deg. or 80.8 deg. <{gamma}<99.2 deg. or 157.3 deg. <{gamma}<168.7 deg. (7.0 deg. <{gamma}<173.0 deg.) at the 68% (95%) confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VERA Core Simulator methodology for pressurized water reactor cycle depletion

This paper describes the methodology developed and implemented in the Virtual Environment for Reactor Applications Core Simulator (VERA-CS) to perform high-fidelity, pressurized water reactor (PWR), multicycle, core physics calculations. Depletion of the core with pin-resolved power and nuclide detail is a significant advance in the state of the art for reactor analysis, providing the level of detail necessary to address the problems of the U.S. Department of Energy Nuclear Reactor Simulation Hub, the Consortium for Advanced Simulation of Light Water Reactors (CASL). VERA-CS has three main components: the neutronics solver MPACT, the thermal-hydraulic (T-H) solver COBRA-TF (CTF), and the nuclide transmutation solver ORIGEN. This paper focuses on MPACT and provides an overview of the resonance self-shielding methods, macroscopic-cross-section calculation, two-dimensional/one-dimensional (2-D/1-D) transport, nuclide depletion, T-H feedback, and other supporting methods representing a minimal set of the capabilities needed to simulate high-fidelity models of a commercial nuclear reactor. Results are presented from the simulation of a model of the first cycle of Watts Bar Unit 1. The simulation is within 16 parts per million boron (ppmB) reactivity for all state points compared to cycle measurements, with an average reactivity bias of <5 ppmB for the entire cycle. Comparisons to cycle 1 flux map data are also provided, and the average 2-D root-mean-square (rms) error during cycle 1 is 1.07%. To demonstrate the multicycle capability, a state point at beginning of cycle (BOC) 2 was also simulated and compared to plant data. The comparison of the cycle 2 BOC state has a reactivity difference of +3 ppmB from measurement, and the 2-D rms of the comparison in the flux maps is 1.77%. Lastly, these results provide confidence in VERA-CS’s capability to perform high-fidelity calculations for practical PWR reactor problems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Internal Digital Image Correlation Technique for High-Strain Rate Dynamic Experiments

Full-field, quantitative visualization techniques, such as digital image correlation (DIC), have unlocked vast opportunities for experimental mechanics. However, DIC has traditionally been a surface measurement technique, and has not been extended to perform measurements on the interior of specimens for dynamic, full-scale laboratory experiments. This limitation restricts the scope of physics which can be investigated through DIC measurements, especially in the context of heterogeneous materials. The focus of this study is to develop a method for performing internal DIC measurements in dynamic experiments. The aim is to demonstrate its feasibility and accuracy across a range of stresses (up to 650 MPa), strain rates (10 3 - 10 6 s -1 ), and high-strain rate loading conditions (e.g., ramped and shock wave loading). Internal DIC is developed based on the concept of applying a speckle pattern at an inner-plane of a transparent specimen. The high-speed imaging configuration is coupled to the traditional dynamic experimental setups, and is focused on the internal speckle pattern. During the experiment, while the sample deforms dynamically, in-plane, two-dimensional deformations are measured via correlation of the internal speckle pattern. In this study, the viability and accuracy of the internal DIC technique is demonstrated for split-Hopkinson (Kolsky) pressure bar (SHPB) and plate impact experiments. The internal DIC experimental technique is successfully demonstrated in both the SHPB and plate impact experiments. In the SHPB setting, the accuracy of the technique is excellent throughout the deformation regime, with measurement noise of approximately 0.2% strain. In the case of plate impact experiments, the technique performs well, with error and measurement noise of 1% strain. The internal DIC technique has been developed and demonstrated to work well for full-scale dynamic high-strain rate and shock laboratory experiments, and the accuracy is quantified. Here, the technique can aid in investigating the physics and mechanics of the dynamic behavior of materials, including local deformation fields around dynamically loaded material heterogeneities.

36 MATERIALS SCIENCE↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

Observation of B 0 → χ c 0 K * 0 and evidence for B + → χ c 0 K * +

We present the observation of the decay B 0 → χ c 0 K * 0 as well as evidence of B + → χ c 0 K * + , with an 8.9 and a 3.6 standard deviation significance, respectively, using a data sample of 454&times;10 6 $Υ(4S)→B \bar{B}$ decays collected with the BABAR detector at the PEP-II B meson factory located at the Stanford Linear Accelerator Center (SLAC). The measured branching fractions are B ( B 0 → χ c 0 K * 0 )=(1.7±0. 3±0.2)×10 -4 and B (B + →χ c0 K* + )=(1.4±0. 5±0.2)×10 -4 , where the first quoted errors are statistical and the second are systematic. Finally, we obtain a branching fraction upper limit of B (B + →χ c0 K* + )<2.1×10 -4 at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

XO-2b: A HOT JUPITER WITH A VARIABLE HOST STAR THAT POTENTIALLY AFFECTS ITS MEASURED TRANSIT DEPTH

The transiting hot Jupiter XO-2b is an ideal target for multi-object photometry and spectroscopy as it has a relatively bright (V-mag = 11.25) K0V host star (XO-2N) and a large planet-to-star contrast ratio (R{sub p}/R{sub s} ≈ 0.015). It also has a nearby (31.″21) binary stellar companion (XO-2S) of nearly the same brightness (V-mag = 11.20) and spectral type (G9V), allowing for the characterization and removal of shared systematic errors (e.g., airmass brightness variations). We have therefore conducted a multiyear (2012–2015) study of XO-2b with the University of Arizona’s 61″ (1.55 m) Kuiper Telescope and Mont4k CCD in the Bessel U and Harris B photometric passbands to measure its Rayleigh scattering slope to place upper limits on the pressure-dependent radius at, e.g., 10 bar. Such measurements are needed to constrain its derived molecular abundances from primary transit observations. We have also been monitoring XO-2N since the 2013–2014 winter season with Tennessee State University’s Celestron-14 (0.36 m) automated imaging telescope to investigate stellar variability, which could affect XO-2b’s transit depth. Our observations indicate that XO-2N is variable, potentially due to cool star spots, with a peak-to-peak amplitude of 0.0049 ± 0.0007 R-mag and a period of 29.89 ± 0.16 days for the 2013–2014 observing season and a peak-to-peak amplitude of 0.0035 ± 0.0007 R-mag and 27.34 ± 0.21 day period for the 2014–2015 observing season. Because of the likely influence of XO-2N’s variability on the derivation of XO-2b’s transit depth, we cannot bin multiple nights of data to decrease our uncertainties, preventing us from constraining its gas abundances. This study demonstrates that long-term monitoring programs of exoplanet host stars are crucial for understanding host star variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncertainty Analysis on the Design of Thermal Conductivity Measurement by a Guarded Cut-Bar Technique

A technique adapted from the guarded-comparative-longitudinal heat flow method was selected for the measurement of the thermal conductivity of a nuclear fuel compact over a temperature range characteristic of its usage. This technique fulfills the requirement for non-destructive measurement of the composite compact. Although numerous measurement systems have been created based on the guarded comparative method, comprehensive systematic (bias) and measurement (precision) uncertainty associated with this technique have not been fully analyzed. Using finite element modeling, this paper presents the study of two types of error sources in the thermal conductivity measurement process: sample and system geometries and working conditions. The results and conclusions provide valuable reference for designing and operating an experimental measurement system using this technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation of Distortion and Residual Stress Development During Heat Treatment of Steel Castings

Heat treatment and associated processing, such as quenching, are critical during high strength steel casting production. These processes must be managed closely to prevent thermal and residual stresses that may result in distortion, cracking (particularly after machining), re-work, and weld repair. The risk of casting distortion limits aggressive quenching that can be beneficial to the process and yield an improved outcome. As a result of these distortions, adjustments must be made to the casting or pattern design, or tie bars must be added. Straightening castings after heat treatments can be both time-consuming and expensive. Residual stresses may reduce a casting's overall service performance, possibly resulting in catastrophic failure. Stress relieving may help, but expends additional energy in the process. Casting software is very limited in predicting distortions during heat treatment, so corrective measures most often involve a tedious trial-and-error procedure. An extensive review of existing heat treatment residual stress and distortion modeling revealed that it is vital to predict the phase transformations and microstructure of the steel along with the thermal stress development during heat treatment. After reviewing the state-of-the-art in heat treatment residual stress and distortion modeling, an existing commercial code was selected because of its advanced capabilities in predicting phase transformations, the evolving microstructure and related properties along with thermal stress development during heat treatment. However, this software was developed for small parts created from forgings or machined stock, and not for steel castings. Therefore, its predictive capabilities for heat treatment of steel castings were investigated. Available experimental steel casting heat treatment data was determined to be of insufficient detail and breadth, and so new heat treatment experiments were designed and performed, casting and heat treating modified versions of the Navy-C ring (a classical test shape for heat treatment experiments) for several carbon and low alloy steels in order to generate data necessary to validate the code. The predicted distortions were in reasonable agreement with the experimentally measured values. However, the final distortions in the castings were small, making it difficult to determine how accurate the predictions truly are. It is recommended that further validation of the software be performed with the aid of additional experiments with large production steel castings that experience significant heat treatment distortions. It is apparent from this research that the mechanical properties of the bonded sand used for cores and sand molds are key in producing accurate stress simulation results. Because of this, experiments were performed to determine the temperature-dependent elastic modulus of a resin-bonded sand commonly utilized in the steel casting industry. The elastic modulus was seen to vary significantly with heating and cooling rates. Also, the retained room temperature elastic modulus after heating was seen to degrade significantly when the sand was heated above 125°C. The elastic modulus curves developed in this work can readily be utilized in casting simulation software. Additional experiments with higher heating rates are recommended to determine the behavior of the elastic modulus in the sand close to the mold-metal interface. The commercial heat treatment residual stress and distortion code, once fully validated, is expected to result in an estimated energy savings of 2.15 trillion BTU's/year. Along with these energy savings, reduction of scrap and improvement in casting yield will result in a reduction of the environmental emissions associated with the melting and pouring of the metal which will be saved as a result of this technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗