Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Field Geologic Observation and Sample Collection Strategies for Planetary Surface Exploration: Insights from the 2010 Desert RATS Geologist Crewmembers

Observation is the primary role of all field geologists, and geologic observations put into an evolving conceptual context will be the most important data stream that will be relayed to Earth during a planetary exploration mission. Sample collection is also an important planetary field activity, and its success is closely tied to the quality of contextual observations. To test protocols for doing effective planetary geologic field- work, the Desert RATS(Research and Technology Studies) project deployed two prototype rovers for two weeks of simulated exploratory traverses in the San Francisco volcanic field of northern Arizona. The authors of this paper represent the geologist crew members who participated in the 2010 field test.We document the procedures adopted for Desert RATS 2010 and report on our experiences regarding these protocols. Careful consideration must be made of various issues that impact the interplay between field geologic observations and sample collection, including time management; strategies relatedtoduplicationofsamplesandobservations;logisticalconstraintson the volume and mass of samples and the volume/transfer of data collected; and paradigms for evaluation of mission success. We find that the 2010 field protocols brought to light important aspects of each of these issues, and we recommend best practices and modifications to training and operational protocols to address them. Underlying our recommendations is the recognition that the capacity of the crew to flexibly execute their activities is paramount. Careful design of mission parameters, especially field geologic protocols, is critical for enabling the crews to successfully meet their science objectives.

Hurtado, Jose M., Jr.↗

A Phase 1/2 Trial of a Combination of Paclitaxel and Trastuzumab With Daily Irradiation or Paclitaxel Alone With Daily Irradiation After Transurethral Surgery for Noncystectomy Candidates With Muscle-Invasive Bladder Cancer (Trial NRG Oncology RTOG 0524)

Purpose: Bladder preservation therapy is an effective treatment for muscle-invasive urothelial carcinoma (UC). In this study we treated noncystectomy candidates with daily radiation and weekly paclitaxel for 7 weeks. Patients whose tumors showed her2/neu overexpression were additionally treated with weekly trastuzumab. Methods and Materials: Sixty-eight evaluable patients were treated with radiation therapy and either paclitaxel + trastuzumab (group 1) or paclitaxel alone (group 2). Groups were assigned on the basis of her2/neu immunohistochemistry results. Patients received 1.8-Gy fractions to a total dose of 64.8 Gy. The primary endpoint of the study was treatment-related toxicity, and secondary endpoints included complete response (CR) rate, protocol completion rate, and survival. Results: A total of 20 evaluable patients were treated in group 1 and 46 patients in group 2. Acute treatment-related adverse events (AEs) were observed in 7 of 20 patients in group 1 (35%) and 14 of 46 patients in group 2 (30.4%). Protocol therapy was completed by 60% (group 1) and 74% (group 2) of patients. Most incompletions were due to toxicity, and the majority of AEs were gastrointestinal, including 1 grade 5 AE (group 1). Two other deaths (both in group 2) were unrelated to protocol therapy. No unexpected cardiac, hematologic, or other toxicities were observed. The CR rate at 1 year was 72% for group 1 and 68% for group 2. Conclusions: In patients with muscle-invasive UC who are not candidates for cystectomy, daily radiation combined with paclitaxel is an effective treatment strategy with a high completion rate and moderate toxicity. In patients with her2/neu-positive tumors, a group generally considered to have worse outcomes, the addition of trastuzumab appears to result in comparable efficacy and toxicity. Further biomarker-driven trials should be undertaken in advancing treatment of this challenging disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ATM QoS Experiments Using TCP Applications: Performance of TCP/IP Over ATM in a Variety of Errored Links

Asynchronous Transfer Mode (ATM) Quality of Service (QoS) experiments using the Transmission Control Protocol/Internet Protocol (TCP/IP) were performed for various link delays. The link delay was set to emulate a Wide Area Network (WAN) and a Satellite Link. The purpose of these experiments was to evaluate the ATM QoS requirements for applications that utilize advance TCP/IP protocols implemented with large windows and Selective ACKnowledgements (SACK). The effects of cell error, cell loss, and random bit errors on throughput were reported. The detailed test plan and test results are presented herein.

Frantz, Brian D.↗

Recovery of postural equilibrium control following space flight

DSO 605 represents the first large study of balance control following spaceflight. Data collected during DSO 605 confirm the theory that postural ataxia following short duration spaceflight is of vestibular origin. We used the computerized dynamic posturography technique developed by Nashner et al. to study the role of the vestibular system in balance control in astronauts during quiet stance before and after spaceflight. Our results demonstrate unequivocally that balance control is disrupted in all astronauts immediately after return from space. The most severely affected returning crew members performed in the same way as vestibular deficient patients exposed to this test battery. We conclude that otolith mediated spatial reference provided by the terrestrial gravitational force vector is not used by the astronauts balance control systems immediately after spaceflight. Because the postflight ataxia appears to be mediated primarily by CNS adaptation to the altered vestibular inputs caused by loss of gravitational stimulation, we believe that intermittent periods of exposure to artificial gravity may provide an effective in-flight countermeasure. Specifically, we propose that in-flight centrifugation will allow crew members to retain their terrestrial sensory-motor adapted states while simultaneously developing microgravity adapted states. The dual-adapted astronaut should be able to make the transition from microgravity to unit gravity with minimal sensory-motor effects. We have begun a ground based program aimed at developing short arm centrifuge prescriptions designed to optimize adaptation to altered gravitational environments. Results from these experiments are expected to lead directly to in-flight evaluation of the proposed centrifuge countermeasure. Because our computerized dynamic posturography system was able to (1) quantify the postflight postural ataxia reported by crew members and observed by flight surgeons and scientists, (2) track the recovery of normal (preflight) balance control, (3) differentiate between rookie and veteran subjects, and (4) provide normative and clinical databases for comparison, and because our study successfully characterized postflight balance control recovery in a large cross-section of Shuttle crew members, we recommend that this system and protocol be adopted as a standard dependent measure for evaluating the efficacy of countermeasures and/or evaluating the postflight effects of changing mission durations or activities.

Paloski, William H.↗

MO-B-BRB-00: Optimizing the Treatment Planning Process

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-01: Optimize Treatment Planning Process in Clinical Environment

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-02: Maintain the Quality of Treatment Planning for Time-Constraint Cases

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-03: Systems Engineering Tools for Treatment Planning Process Optimization in Radiation Medicine

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

An Approach to Evaluate Precision and Inter-Laboratory Variability of Flammability Test Methods for Aerospace Materials

Materials selection for spacecraft is based on conventional flammability or ignition sensitivity acceptance tests. Current procedures for determining the inter-laboratory repeatability and reproducibility of aerospace materials flammability tests are not considering the dependence of data variability on test conditions and consequently attempts to characterize the precision of these methods were not successful. The inter-laboratory data variability is determined with tests conducted under arbitrary conditions, which consequently may not provide sufficient information to enable adequate determination of a method's precision. For evaluating the precision of NASA's flammability test methods, the protocol recommended includes selecting critical parameters and determining the 50% failure point by considering the specific failure criteria of each method using the critical parameter as a variable. Upon performing inter-laboratory round robin testing using this approach, the laboratories' performance could be evaluated by comparing the repeatability of the 50% failure point and/or the repeatability of critical conditions where the probabilities of passing and failing are unity, i.e., the transition zone repeatability. When a sufficient amount of data has been acquired with this method, an adequate estimation of precision of aerospace materials flammability test methods will be possible.

Hirsch, David↗

A Simple XML Producer-Consumer Protocol

This document describes a simple XML-based protocol that can be used for producers of events to communicate with consumers of events. The protocol described here is not meant to be the most efficient protocol, the most logical protocol, or the best protocol in any way. This protocol was defined quickly and it's intent is to give us a reasonable protocol that we can implement relatively easily and then use to gain experience in distributed event services. This experience will help us evaluate proposals for event representations, XML-based encoding of information, and communication protocols. The next section of this document describes how we represent events in this protocol and then defines the two events that we choose to use for our initial experiments. These definitions are made by example so that they are informal and easy to understand. The following section then proceeds to define the producer-consumer protocol we have agreed upon for our initial experiments.

Smith, Warren↗

Simulation of Isotopic Concentrations and Gamma Spectra from Dynamic Fission Sources

A tool was developed to rapidly generate synthetic gamma-ray spectra to evaluate safeguards material control and accounting methods for liquid-fueled molten salt reactors. Molten salt reactor operations pose unique challenges to nuclear safeguards methods and protocols compared to deployed reactors designs (e.g., light water reactors). This research evaluates the use of gamma-ray spectroscopy to monitor fission product isotopic flow through a reactor model to understand expected operations and investigate changes to the spectra with material diversion scenarios. The large design space of molten salt reactors (e.g., liquid-fueled, liquid-cooled, online separations) could potentially lead to many measurement points within the reactor system. The developed analytical tool generates and evaluates synthetic gamma-ray spectra from dynamic reactor simulations by extracting isotopic inventory to generate source terms. An implementation in the Gamma Detector Response and Analysis Software (GADRAS) Application Program Interface (API) uses the source terms, a model of the reactor component, a detector response function, and measurement plan to quickly generate and analyze spectra. Prospective measurements are then evaluated in the more accurate but slower Geant4 simulations. Utilization of the developed modeling tool and analysis of the subsequent spectra enables optimization of collimation, shielding requirements, and expected count rates that are used to determine key measurement points in the modeled reactor design.

O'Brien, Sean↗

Protocol for assembling and operating bipolar membrane water electrolyzers

Renewable energy-driven bipolar membrane water electrolyzers (BPMWEs) are a promising technology for sustainable production of hydrogen from seawater and other impure water sources. Here, we present a protocol for assembling BPMWEs and operating them in a range of water feedstocks, including ultra-pure deionized water and seawater. We describe steps for membrane electrode assembly preparation, electrolyzer assembly, and electrochemical evaluation. For complete details on the use and execution of this protocol, please refer to Marin et al. (2023).

Rios Amador, Isabela↗

Evaluating Synthetic Smart Meter Locations For Communication System Modeling

An important part of good communication models for smart grid applications, particularly when wireless protocols are used, is the location information of the nodes. We’ve developed metrics to assist in evaluating whether a given model with such information is representative of feeders found in the world. These metrics are applied to a set of feeder models with known good location information for the smart meter locations and compared to a set of feeder models with similar location information that is not expected to be representative of real-world feeders. The comparison reveals that the suspect models do not pass statistical tests utilizing the developed metrics, providing initial validation of the analysis technique.

smart meter, feeder model, GridLAB-D↗

Tools and Technologies Needed for Conducting Planetary Field Geology While On EVA: Insights from the 2010 Desert RATS Geologist Crewmembers

Observation is the primary role of all field geologists, and geologic observations put into an evolving conceptual context will be the most important data stream that will be relayed to Earth during a planetary exploration mission. Sample collection is also an important planetary field activity, and its success is closely tied to the quality of contextual observations. To test protocols for doing effective planetary geologic fieldwork, the Desert RATS (Research and Technology Studies) project deployed two prototype rovers for two weeks of simulated exploratory traverses in the San Francisco volcanic field of northern Arizona. The authors of this paper represent the geologist crewmembers who participated in the 2010 field test. We document the procedures adopted for Desert RATS 2010 and report on our experiences regarding these protocols. Careful consideration must be made of various issues that impact the interplay between field geologic observations and sample collection, including time management; strategies related to duplication of samples and observations; logistical constraints on the volume and mass of samples and the volume/transfer of data collected; and paradigms for evaluation of mission success. We find that the 2010 field protocols brought to light important aspects of each of these issues, and we recommend best practices and modifications to training and operational protocols to address them. Underlying our recommendations is the recognition that the capacity of the crew to "flexibly execute" their activities is paramount. Careful design of mission parameters, especially field geologic protocols, is critical for enabling the crews to successfully meet their science objectives.

Young, Kelsey↗

NIST Efforts to Quality-Assure Gunpowder Measurements

In the past few years, the National Institute for Standards and Technology (NIST) has been promoting the idea of quantitatively determining the additives in smokeless gunpowder using micellar capillary electrophoresis as a means of investigating the criminal use of hand guns and pipe bombs. As a part of this effort, we have evaluated both supercritical fluid and ultrasonic solvent extractions for the quantitative recovery of nitroglycerin (NG), diphenylamine (DPA), N-nitrosodiphenylamine (NnDPA), and ethyl centralite (EC) from gunpowder. Recoveries were evaluated by repeat extraction and matrix spiking experiments. The final extraction protocol provides greater than 95 percent recoveries. To help other researches validate their own analytical method for additive determinations, NIST is exploring the development of a standard reference material, Additives in Smokeless Gunpowder. The evaluated method is being applied to two double-base (NG-containing) powders, one stabilized with diphenylamine and the other with ethyl centralite. As part of this reference material development effort, we are conducting an interlaboratory comparison exercise among the forensic and military gunpowder measurement community.

MacCrehan, William A.↗

Poster - 10: QA of Ultrasound Images for Prostate Brachytherapy

Purpose: The current QA protocol of ultrasound systems used in prostate brachytherapy (TG128) addresses geometrical verifications, but the scope of evaluation of image quality is limited. We recognized importance of the latter in routine practice, and designed a protocol for QA of the images. Methods: Images of an ultrasound prostate phantom (CIRS053) were collected with BK Flex Focus 400. The images were saved as bmp after adjusting the gain to 50% for consistent results. Mean pixel values and signal to noise ratio were inspected in the representative sections of the phantom, including the mock prostate and the unechoic medium. Constancy of these numbers over a one year period was looked at. Results: The typical intensity in the mock prostate region in the transverse images ranged between 95 and 118 (out of 256), and the signal to noise was about 10. The intensity in the urethra region was about 170±40, and the unechoic medium was 2±2. The mean and the signal to noise ratio remained almost unchanged after a year, while the signal in the unechoic medium increased to about 7±4. Similar values were obtained in the sagittal images. Conclusions: The image analysis discussed above allows quick evaluation of constancy of the image quality. This may be also useful in troubleshooting image-quality problems during routine exams, which might not be due to deterioration of the US system, but other reasons, e.g. variations in tissue properties or air being trapped between the probe and the anatomy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-81: Assessment of CT Radiation Dose and Image Quality for An Automated Tube Potential Selection Algorithm Using Adult Anthropomorphic and ACR Phantoms

Purpose: To assess the impact of General Electrics (GE) automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of an adult anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, Auto mA (180 to 380 mA), noise index (NI) = 14, adaptive iterative statistical reconstruction (ASiR) of 20%, 0.8s rotation time. Image quality was evaluated by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACR CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document. NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: The CNR for the adult male was found to decrease from CNR = 0.912 ± 0.045 for the baseline protocol without kVa to a CNR = 0.756 ± 0.049 with kVa activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.903 ± 0.023. The difference in the central liver dose with and without kVa was found to be 0.07%. Conclusion: Dose reduction was insignificant in the adult phantom. As determined by NPS analysis, ASiR of 40% produced images with similar noise texture to the baseline protocol. However, the CNR at ASiR of 40% with kVa fails to meet the current ACR CNR passing requirement of 1.0.

60 APPLIED LIFE SCIENCES↗

Evaluating alternative refrigerants for high ambient temperature environments

According to the Montreal Protocol, developing countries have started the phase out schedule of the ozone depleting substances, including HCFC refrigerants, in 2015 and expect them to reach 35% reduction in 2020. This commitment to the start the phase out of HCFC refrigerants, especially R-22, in developing countries is seen as an opportunity to introduce lower Global Warming Potential (GWP) refrigerants. Furthermore, this paper summarizes an investigation into the performance of lower GWP refrigerants in high ambient temperature environments, experienced in some of the developed countries, in mini-split air conditioning units.

54 ENVIRONMENTAL SCIENCES↗