Search NASA⌕ Search

SEARCH · Search NASA

Results for “filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Filter Aerosol Measurements for ARM

The goal of this study was to determine the best filter media for use in Atmospheric Radiation Measurement (ARM) particle soot absorption photometers (PSAPs) following the manufacturer discontinuation of the current filter media. The study comprised multiple experiments to assess four potential replacement filter medium relative to the Pallflex E-70, which is being discontinued, and is documented in ARM’s ServiceNow system under ENG0003846. The experiments laid out in the document ‘180504 Filter Aerosol Measurements for ARM.docx’ and several subsequent tests suggest that the Pallflex Emfab media is the best candidate for ongoing ARM filter-based absorbance measurements. Other media were ruled out based on particle capture efficiency for small particles. In tests with Nigrosin, Emfab exceeded all other media. Tests were done measuring reported absorbance for all media in PSAPs operated in parallel sampling under several conditions: ambient air, three sizes of black-dyed PSL (polystyrene latex) spheres, and Nigrosin particles. These tests indicate a different factor of reported absorbance for each media relative to the original Pallflex E70 filter. The factor for the Azumi media was consistent with unpublished work by Ogren (National Oceanic and Atmospheric Administration [NOAA]). The tests described here were not exhaustive and were complicated by time-varying differences among the PSAPs used. However, it is concluded that they are sufficient to justify ARM switching to Emfab filter media for future ARM PSAP measurements. The remaining store of E70 will be reserved to quantitatively characterize differences between Emfab and E70 (and Azumi?) in both laboratory and field side-by-side tests as put forth in a succeeding ENG. This future work will empirically identify correction factors applicable to Emfab and quantify the uncertainty in comparing the historical E70 measurements with ongoing Emfab measurements. Comparison of PSAP measurements with an independent absolute ‘reference’ for aerosol absorbance, i.e., photo thermal interferometry or difference measurements of cavity attenuated phase shift extinction (CAPS) minus nephelometry scattering, would be valuable but exceed the scope of ARM Infrastructure. While the characterization of correction factors is required for maintaining and improving accuracy in future absorption measurements, it was beyond the scope of the current study.

aerosol observing system↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

The compensated Kalman filter.

This paper introduces the compensated Kalman filter, a suboptimal state estimator which can be used to eliminate steady-state bias errors when it is used in conjunction with the mismatched steady-state (asymptotic) time-invariant Kalman-Bucy filter. The uncompensated mismatched steady state Kalman-Bucy filter exhibits bias errors whenever the nominal plant parameters used in the filter design are different from the actual plant parameters. The approach used relies on the utilization of the residual (innovations) process of the mismatched filter to estimate, via a Kalman-Bucy filter, the state estimation errors and subsequent improvements of the state estimate. The compensated Kalman filter augments the mismatched steady state Kalman-Bucy filrby the introduction of additional dynamics and feedforward integral compensation channels.

Athans, M.↗

A biased filter for linear discrete dynamic systems.

A recursive estimator, the ridge filter, was developed for the linear discrete dynamic estimation problem. Theorems were established to show that the ridge filter can be, on the average, closer to the expected value of the system state than the Kalman filter. On the other hand, Kalman filter, on the average, is closer to the instantaneous system state than the ridge filter. The ridge filter has been formulated in such a way that the computational features of the Kalman filter are preserved.

Chang, J. W.↗

Effect of filtering on noise and timing in nuclear particle detection

The relations between signal shaping, noise, and timing resolution in nuclear particle detection systems are examined in this paper. Mathematical analysis of five commonly used types of filters leads to numerical results for system noise components arising from sources in the preamplifier, detector, and bias resistors. These results are presented in the form of design curves for the various filters, showing the dependence of each output noise component on both the magnitude of the noise sources and the filter time constants. Three of the filters considered are simple RC types; the remaining two are combinations of delay lines and RC elements. The quantitative calculations specifically assume a silicon detector and a field-effect-transistor preamplifier. Those filters that exhibit bipolar step response are analyzed in terms of crossover timing resolution, based on the earlier noise calculations. Again, the results are summarized in sets of design curves for each filter. Finally, the comparative performance of the various filter types is discussed, and specific examples are given.

Gary, S. A.↗

Fourier plane filters

An electrically addressed liquid crystal Fourier plane filter capable of real time optical image processing is described. The filter consists of two parts: a wedge filter having forty 9 deg segments and a ring filter having twenty concentric rings in a one inch diameter active area. Transmission of the filter in the off (transparent) state exceeds fifty percent. By using polarizing optics, contrast as high as 10,000:1 can be achieved at voltages compatible with FET switching technology. A phenomenological model for the dynamic scattering is presented for this special case. The filter is designed to be operated from a computer and is addressed by a seven bit binary word which includes an on or off command and selects any one of the twenty rings or twenty wedge pairs. The overall system uses addressable latches so that once an element is in a specified state, it will remain there until a change of state command is received. The drive for the liquid crystal filter is ? 30 V peak at 30 Hz to 70 Hz. These parameters give a rise time for the scattering of 20 msec and a decay time of 80 to 100 msec.

Oliver, D. S.↗

The Lockheed alternate partial polarizer universal filter

A tunable birefringent filter using an alternate partial polarizer design has been built. The filter has a transmission of 38% in polarized light. Its full width at half maximum is .09A at 5500A. It is tunable from 4500 to 8500A by means of stepping motor actuated rotating half wave plates and polarizers. Wave length commands and thermal compensation commands are generated by a PPD 11/10 minicomputer. The alternate partial polarizer universal filter is compared with the universal birefringent filter and the design techniques, construction methods, and filter performance are discussed in some detail. Based on the experience of this filter some conclusions regarding the future of birefringent filters are elaborated.

Title, A. M.↗

An RC active filter design handbook

The design of filters is described. Emphasis is placed on simplified procedures that can be used by the reader who has minimum knowledge about circuit design and little acquaintance with filter theory. The handbook has three main parts. The first part is a review of some information that is essential for work with filters. The second part includes design information for specific types of filter circuitry and describes simple procedures for obtaining the component values for a filter that will have a desired set of characteristics. Pertinent information relating to actual performance is given. The third part (appendix) is a review of certain topics in filter theory and is intended to provide some basic understanding of how filters are designed.

Deboo, G. J.↗

Development of birefringent filters for spaceflight

The critical problem for flight of a birefringent filter is the shock mounting of the calcite. The design presented here bonds the calcite block with silicon rubbers to the calcite holder. The calcite together with its all necessary polarizers and rotating achromatic plates are mounted together in units called a filter module. By using a set of modules containing calcite crystals of differing lengths, a filter can be produced. A description of the modules is given. Also described is a container for the filter modules, which can be used both to hermetically seal the system or contain an index matching oil. The response of a filter element while being controlled by the Lockheed Temperature Control is described and the determination of the wavelength sensitivity to temperature of calcite is explained. Operation of the filter using a software control algorithm instead of a hardware temperature controller is shown. Some radiation considerations of filter systems are given.

Title, A. M.↗

Estimation and filter stability of stochastic delay systems

Linear and nonlinear filtering for stochastic delay systems are studied. A representation theorem for conditional moment functionals is obtained, which, in turn, is used to derive stochastic differential equations describing the optimal linear or nonlinear filter. A complete characterization of the optimal filter is given for linear systems with Gaussian noise. Stability of the optimal filter is studied in the case where there are no delays in the observations. Using the duality between linear filtering and control, asymptotic stability of the optimal filter is proved. Finally, the cascade of the optimal filter and the deterministic optimal quadratic control system is shown to be asymptotically stable as well.

Kwong, R. H.↗

Input filter compensation for switching regulators

The problems caused by the interaction between the input filter, output filter, and the control loop are discussed. The input filter design is made more complicated because of the need to avoid performance degradation and also stay within the weight and loss limitations. Conventional input filter design techniques are then dicussed. The concept of pole zero cancellation is reviewed; this concept is the basis for an approach to control the peaking of the output impedance of the input filter and thus mitigate some of the problems caused by the input filter. The proposed approach for control of the peaking of the output impedance of the input filter is to use a feedforward loop working in conjunction with feedback loops, thus forming a total state control scheme. The design of the feedforward loop for a buck regulator is described. A possible implementation of the feedforward loop design is suggested.

Lee, F. C.↗

Tunable birefringent filters

This article reviews the types and capabilities of birefringent filters. The general operating principles of Lyot (perfect polarizers), partial polarizing, and Solc (no internal polarizers) filters are introduced. Appropriate techniques for tuning each filter type are presented. Field of view of birefringent filters is discussed and is compared to Fabry-Perot and interference filters. The transmission and throughput advantages of birefringent filters are shown. Finally, the current state of the art in practical filters is reviewed.

Title, A. M.↗

A preliminary assessment of the problems in the use of interference filter photometers to determine total ozone

In the spring of 1979 an investigation was started involving the intercomparison of five ground based instruments designed to measure total ozone. The instruments considered include the Dobson spectrometer, the Russian M-83 ozonometer, the Brewer Ozone Spectrophotometer, the New Zealand (Canterbury) filter photometer, and the SenTran Company filter photometer. Three of these instruments use optical filters to make spectrophotometric determinations of total atmospheric ozone. The M-83 uses glass absorption filters to isolate the ultraviolet bands used. The Canterbury and the SenTran instruments use narrow-bandpass dielectric interference filters for the same purpose. Instruments employing optical filters are very appealing since they can be made small, rugged, and relatively inexpensive. However, the results of the reported investigation show that serious problems must be resolved before any filter instrument can be considered reliable enough for the conduction of long term, meaningful ozone measurements.

Gerlach, J. C.↗

Effect of RF Filtering on the Performance of Uncoded PCM/PM Telemetry Channels

A method for calculating the increase in received telemetry signal power required to compensate for the use of a radio frequency interference (RFI) filter in front of the DSN receiving system low-noise amplifier is described. The telemetry system for which the degradation is calculated is an uncoded PCM/PM system in which the NRZ data directly modulates the carrier at a modulation level which leaves a discrete carrier. A phase-locked loop in the RF receiver tracks the discrete carrier and coherently demodulates the PCM data. The RFI filter may be a series of Butterworth, Tchebychev, or Bessel low-pass, high-pass, band-pass, or band-reject filters, each with arbitrary bandwidth, number of poles, and, for band-pass or band-reject filters, resonant frequency. The only restriction is that the RFI filter must have only simple poles. Numerical results are presented for the RFI filters the DSN plans to place in front of the S-band FET, S-band maser, and X-band maser low noise amplifiers. The main conclusion is that the filters will produce negligible degradation at data rates below 4 Mbps.

Koerner, M. A.↗

An allpass filter design for luminance and chrominance separation of NTSC signals

Abstract- Digital techniques for separation of luminance and chrominance components from composite NTSC broadcast television signals are explored. First, comb filters are introduced. Secondly, filters based on linear regression are developed. Finally, a third filtering form, the allpass filter is considered. Techniques are compared based on mean squared error criteria and subjective testing. It is demonstrated that the allpass filtering technique is superior to both the comb filtering as well as the regression filtering.

Border, D. A.↗

Range filtering for sequential GPS receivers with external sensor augmentation

The filtering of the satellite range and range-rate measurements from single channel sequential Global Positioning System receivers is usually done with an extended Kalman filter which has state variables defined in terms of an orthogonal navigation reference frame. An attractive suboptimal alternative is range-domain filtering, in which the individual satellite measurements are filtered separately before they are combined for the navigation solution. The main advantages of range-domain filtering are decreased processing and storage requirements and simplified tuning. Several range filter mechanization alternatives are presented, along with an innovative approach for combining the filtered range-domain quantities to determine the navigation state estimate. In addition, a method is outlined for incorporating measurements from auxiliary sensors such as altimeters into the navigation state estimation scheme similarly to the satellite measurements. A method is also described for incorporating inertial measurements into the navigation state estimator as a process driver.

Paielli, Russell↗

A nonlinear filtering process diagnostic system for the Space Station

A nonlinear filtering process diagnostic system, terrestrial simulation and real time implementation studies is presented. Possible applications to Space Station subsystem elements are discussed. A process diagnostic system using model based nonlinear filtering for systems with random structure was shown to provide improvements in stability, robustness, and overall performance in comparison to linear filter based systems. A suboptimal version of the nonlinear filter (zero order approximation filter, or ZOA filter) was used in simulation studies, initially, with a pressurized water reactor model and then with water/steam heat exchanger models. Finally, a real time implementation for leak detection in a water/steam heat exchanger was conducted using the ZOA filter and heat exchanger models.

Yoel, Raymond R.↗

Range filtering for sequential GPS receivers

The filtering of the satellite range and range-rate measurements from single channel sequential Global Positioning System receivers is usually done with an extended Kalman filter which has state variables defined in terms of an orthogonal navigation reference frame. An attractive suboptimal alternative is range-domain filtering, in which the individual satellite measurements are filtered separately before they are combined for the navigation solution. The main advantages of range-domain filtering are decreased processing and storage requirements and simplified tuning. Several range filter mechanization alternatives are presented, along with an innovative approach for combining the filtered range-domain quantities to determine the navigation state estimate. In addition, a method is outlined for incorporating measurements from auxiliary sensors such as altimeters into the navigation state estimation scheme similarly to the satellite measurements. A method is also described for incorporating inertial measurements into the navigation state estimator as a process driver.

Paielli, Russell↗