Search NASA⌕ Search

SEARCH · Search NASA

Results for “full scale testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

TPSAS-NF1676L-35020-DND

Low dimensionality materials continue to gain interest in the research community due to a combination of unique optical, electronic transport, and structural properties. Carbon Nanotubes and graphene are two such materials that are attractive for structural health monitoring applications. Single layer graphene is transparent, conductive, strong, flexible, and amenable to deposition by inkjet printing techniques. Carbon nanotubes are extremely strong and lightweight, and available in forms that can be printed, stitched or applied as a sensory patch on a structure. In this work the flexibility, conductivity, and processing capabilities of these low dimensionality carbon structures are coupled to produce directly printed strain sensors. Experimental results from coupon testing through full-scale flight tests are presented and a path toward structural systems with inherent health monitoring discussed.

Buzz Wincheski↗

Full-Scale Wind-Tunnel Tests on Several Metal Propellers Having Different Blade Forms

This report gives the full-scale aerodynamic characteristics of five different aluminum alloy propellers having four different blade forms. They were tested on an open cockpit fuselage with a radial air-cooled engine having conventional cowling. The results show that (1) the differences in propulsive efficiency due to the differences in blade form were small; (2) the form with the thinnest airfoil sections had the highest efficiency; (3) it is advantageous as regards propulsive efficiency for a propeller operating in front of a body, such as a radial engine, to have its pitch reduced toward the hub.

Weick, Fred E↗

Multi-mode evaluation of power-maximizing cross-flow turbine controllers

A general method for predicting and evaluating the performance of three candidate cross-flow turbine power-maximizing controllers is presented in this paper using low-order dynamic simulation, scaled laboratory experiments, and full-scale field testing. For each testing mode and candidate controller, performance metrics quantifying energy capture (ability of a controller to maximize power), variation in torque and rotation rate (related to drive train fatigue), and variation in thrust loads (related to structural fatigue) are quantified for two purposes. First, for metrics that could be evaluated across all testing modes, we considered the accuracy with which simulation or laboratory experiments could predict performance at full scale. Second, we explored the utility of these metrics to contrast candidate controller performance. For these turbines and set of candidate controllers, energy capture was found to only differentiate controller performance in simulation, while the other explored metrics were able to predict performance of the full-scale turbine in the field with various degrees of success. Finally, effects of scale between laboratory and full-scale testing are considered, along with recommendations for future improvements to dynamic simulations and controller evaluation.

13 HYDRO ENERGY↗

Crack Growth Simulation and Residual Strength Prediction in Airplane Fuselages

This is the final report for the NASA funded project entitled "Crack Growth Prediction Methodology for Multi-Site Damage." The primary objective of the project was to create a capability to simulate curvilinear fatigue crack growth and ductile tearing in aircraft fuselages subjected to widespread fatigue damage. The second objective was to validate the capability by way of comparisons to experimental results. Both objectives have been achieved and the results are detailed herein. In the first part of the report, the crack tip opening angle (CTOA) fracture criterion, obtained and correlated from coupon tests to predict fracture behavior and residual strength of built-up aircraft fuselages, is discussed. Geometrically nonlinear, elastic-plastic, thin shell finite element analyses are used to simulate stable crack growth and to predict residual strength. Both measured and predicted results of laboratory flat panel tests and full-scale fuselage panel tests show substantial reduction of residual strength due to the occurrence of multi-site damage (MSD). Detailed comparisons of n stable crack growth history, and residual strength between the predicted and experimental results are used to assess the validity of the analysis methodology. In the second part of the report, issues related to crack trajectory prediction in thin shells; an evolving methodology uses the crack turning phenomenon to improve the structural integrity of aircraft structures are discussed, A directional criterion is developed based on the maximum tangential stress theory, but taking into account the effect of T-stress and fracture toughness orthotropy. Possible extensions of the current crack growth directional criterion to handle geometrically and materially nonlinear problems are discussed. The path independent contour integral method for T-stress evaluation is derived and its accuracy is assessed using a p- and hp-version adaptive finite element method. Curvilinear crack growth is simulated in coupon tests and in full-scale fuselage panel tests. Both T-stress and fracture toughness orthotropy are found to be essential to predict the observed crack paths. The analysis methodology and software program (FRANC3D/STAGS) developed herein allows engineers to maintain aging aircraft economically while insuring continuous airworthiness. Consequently, it will improve the technology to support the safe operation of the current aircraft fleet as well as the design of more damage-tolerant aircraft for the next generation fleet.

Chen, Chuin-Shan↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of airframe design technology for crashworthiness.

This paper describes the NASA portion of a joint FAA-NASA General Aviation Crashworthiness Program leading to the development of improved crashworthiness design technology. The objectives of the program are to develop analytical technology for predicting crashworthiness of structures, provide design improvements, and perform full-scale crash tests. The analytical techniques which are being developed both in-house and under contract are described, and typical results from these analytical programs are shown. In addition, the full-scale testing facility and test program are discussed.

Kruszewski, E. T.↗

Inlet Performance of the NFAC 1/50th-scale 80- by 120- Foot Wind Tunnel

The National Full-Scale Aerodynamics Complex 80- by 120-Foot Wind Tunnel (80x120) was dedicated in 1987 and rated at 100 knots for full-scale aircraft testing at NASA Ames Research Center. The 80x120 is the world’s largest wind tunnel, designed as an open circuit tunnel with a large aerodynamically treated inlet open to the ambient atmospheric air. In 2017, damage was sustained within the wind tunnel drive system, opening a window to do testing using the existing 1/50th-scale model of the 80- by 120-Foot Wind Tunnel within the full-scale 80- by 120-Foot Wind tunnel test section. The objective of the research was to quantify the turbulence levels within the 1/50th-scale test section as a function of onset atmospheric wind direction (± 90 deg from tunnel center-line), variable test section speed (5 – 50 m/s) and purposeful obtrusion of wind flow into the inlet. The model wind tunnel inlet, contraction, and test section are geometrically identical to that of the full-scale wind tunnel and model testing provides aerodynamic performance characteristics under controlled test conditions allowing for insight into the full-scale test section flow quality. The test section turbulence levels are minimally affected by the onset direction of the ambient atmospheric wind, but are dramatically affected by the speed in the tunnel while operated in the presence of winds. Original design specifications were axial/vertical/lateral turbulence ≤ 0.5% at maximum test section speed, though early full scale tunnel testing determined that lateral turbulence would be ≤ 0.6%. For test section speeds ≥ 30 m/s the tunnel is within the design specification limits. Between 5 m/s and 30 m/s, the test section turbulence levels are dependent on the onset wind direction and test section speed where test section turbulence in the axial, vertical and lateral directions was seen to be between 0.5% and 1% and, at times, greater than 1%. Finally, testing was performed with blockage designs at the inlet to disrupt the wind flow quality entering the tunnel contraction zone in an attempt to create higher levels of turbulence for high turbulent test conditions simulating the earth’s boundary layer. The highest turbulence levels measured were 6% in the axial direction by use of large spires designed to obstruct ≈ 50% of the inlet area.

Inlet Performance↗

Post-test data report for the space shuttle full-scale AFRSI sequence of environments test (OS-305-1 to -5) in the NASA/Ames Research Center 11x11-foot wind tunnel

The Advanced Flexible Reusable Surface Insulation (AFRSI) test article was wind tunnel tested. The AFRSI was exposed to a simulated ascent airloads environment and data was obtained which could be used to support the AFRSI certification program. The AFRSI sequence of environments also included radiant heating (1500 degrees Fahrenheit) and wind/rain environments. The test article was wind/rain conditioned before each wind tunnel entry and was thermally conditioned after each wind tunnel entry. The AFRSI failed and the test was aborted before reaching the ascent environment. The AFRSI test article sequentially exposed to 50 wind/rain and 49 simulated entry thermal missions, as well as four wind tunnel entries equivalent to 40 ascent missions.

Marshall, B. A.↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Orion Crew Module Landing System Simulation and Verification

NASA Langley Research Center (LaRC) has developed a comprehensive test and analysis program to evaluate the ability of LS-DYNA to model the materials and the phenomena involved in soil and water landing impacts of the Orion crew module. Elemental, scale boilerplate, and full-scale prototype testing is being conducted in support of the simulation verification and validation approach. Aspects of the simulations evaluated against test data include soil constitutive properties, water equations of state, and contact algorithms. Subsystems tested include airbags, crushable energy absorbing honeycomb materials, and energy absorbing seat support struts. The procedures, instrumentation, and general observations from each test series are presented. Plans for a series of swing tests of a full-scale boilerplate into a purpose-built water basin are described. Further plans for swing tests of flight-like prototypes into the water basin are noted.

Vassilakos, Gregory J.↗

Thermal scale modeling of radiation-conduction-convection systems.

Investigation of thermal scale modeling applied to radiation-conduction-convection systems with particular emphasis on the spacecraft cabin atmosphere/cabin wall thermal interface. The 'modified material preservation,' 'temperature preservation,' 'scaling compromises,' and 'Nusselt number preservation' scale modeling techniques and their inherent limitations and problem areas are described. The compromised scaling techniques of mass flux preservation and heat transfer coefficient preservation show promise of giving adequate thermal similitude while preserving both gas and temperature in the scale model. The use of these compromised scaling techniques was experimentally demonstrated in tests of full scale and 1/4 scale models. Correlation of test results for free and forced convection under various test conditions shows the effectiveness of these scaling techniques. It is concluded that either mass flux or heat transfer coefficient preservation may result in adequate thermal similitude depending on the system to be modeled. Heat transfer coefficient preservation should give good thermal similitude for manned spacecraft scale modeling applications.

Shannon, R. L.↗

Study of Aircraft Structural Response and Occupant Loading During a Ditching Event Utilizing LS-DYNA Simulation

In this study, the capability of finite element model (FEM) analysis to assess aircraft structural response and occupant injury risk during aircraft water ditching conditions was evaluated. A FEM of the Fokker F28 aircraft, previously validated against full-scale crash test data, was simulated in a realistic water impact environment utilizing recorded conditions from the ditching of US Airways Flight 1549 into the Hudson River. The FEM of the F28 aircraft, was developed from a NASTRAN loads model provided by the vehicle manufacturer, calibrated using component fuselage drop-tests, and validated through test-analysis comparisons from a full-scale crash test of the F28 onto soil. Simulation results are presented in several categories: vehicle kinematics, structural accelerations, damage, occupant responses, and injury risk predictions. Results were consistent with the general outcomes of Flight 1549, indicating that the developed vehicle FEM, validated against land impact test data, may provide an effective tool for evaluating water ditching events.

Jacob Putnam↗

Southern Impact Testing Alliance (SITA)

Efforts to form this Alliance began in 2008 to showcase the impact testing capabilities within the southern United States. Impact testing customers can utilize SITA partner capabilities to provide supporting data during all program phases-materials/component/ flight hardware design, development, and qualification. This approach would allow programs to reduce risk by providing low cost testing during early development to flush out possible problems before moving on to larger scale1 higher cost testing. Various SITA partners would participate in impact testing depending on program phase-materials characterization, component/subsystem characterization, full-scale system testing for qualification. SITA partners would collaborate with the customer to develop an integrated test approach during early program phases. Modeling and analysis validation can start with small-scale testing to ensure a level of confidence for the next step large or full-scale conclusive test shots. Impact Testing Facility (ITF) was established and began its research in spacecraft debris shielding in the early 1960's and played a malor role in the International Space Station debris shield development. As a result of return to flight testing after the loss of STS-107 (Columbia) MSFC ITF realized the need to expand their capabilities beyond meteoroid and space debris impact testing. MSFC partnered with the Department of Defense and academic institutions as collaborative efforts to gain and share knowledge that would benefit the Space Agency as well as the DoD. MSFC ITF current capabilities include: Hypervelocity impact testing, ballistic impact testing, and environmental impact testing.

Hubbs, Whitney↗

Development and Operation of an Automatic Rotor Trim Control System for use During the UH-60 Individual Blade Control Wind Tunnel Test

A full-scale wind tunnel test to evaluate the effects of Individual Blade Control (IBC) on the performance, vibration, noise and loads of a UH-60A rotor was recently completed in the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel [1]. A key component of this wind tunnel test was an automatic rotor trim control system that allowed the rotor trim state to be set more precisely, quickly and repeatably than was possible with the rotor operator setting the trim condition manually. The trim control system was also able to maintain the desired trim condition through changes in IBC actuation both in open- and closed-loop IBC modes, and through long-period transients in wind tunnel flow. This ability of the trim control system to automatically set and maintain a steady rotor trim enabled the effects of different IBC inputs to be compared at common trim conditions and to perform these tests quickly without requiring the rotor operator to re-trim the rotor. The trim control system described in this paper was developed specifically for use during the IBC wind tunnel test

Theodore, Colin R.↗

Tests of a Full-Scale Model of the Republic XF-91 Airplane in the Ames 40- by 80-Foot Wind Tunnel. Force and Moment Data

Wind-tunnel tests of a full-scale model of the Republic XF-91 airplane having swept-back wings and a vee tail were conducted to determine both the stability and control characteristics of the model longitudinally, laterally, and directionally. Configurations of the model were investigated involving such variables as external fuel tanks, a landing gear, trailing-edge flaps, leading-edge slats, and a range of wing incidences and tail incidences.

Hunten, Lynn W.↗