Search NASA⌕ Search

SEARCH · Search NASA

Results for “high resolution detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Diffused trenches for high fill-factor Low-Gain Avalanche Diodes

Low-Gain Avalanche Diodes (LGADs) are a class of silicon detectors that have been specifically designed for the fast detection of minimum ionizing particles (mips) in High-Energy Physics experiments. While they provide timing resolution on the order of a few tens of picoseconds, they cannot achieve high spatial resolution due to the intrinsic characteristics of their structures. Thus, active R&D is on-going to develop detectors based on LGADs to improve their spatial resolution while maintaining the timing performance of the LGADs. Such devices are, for example, AC-coupled LGADs and Deep-Junction LGADs. Another device option is the Trench-Isolated LGAD (TI LGAD), where trenches etched at the periphery of the pixels isolate them while providing a high fill-factor. Here, in this paper, we present a variation of this latter approach, demonstrating its feasibility by means of 2-dimensional TCAD simulations.

47 OTHER INSTRUMENTATION↗

Design of High-Performance Photon-Number-Resolving Photodetectors Based on Coherently Interacting Nanoscale Elements

A number of applications in basic science and technology would benefit from high-fidelity photon-number-resolving photodetectors. While some recent experimental progress has been made in this direction, the requirements for true photon number resolution are stringent, and no design currently exists that achieves this goal. Here we employ techniques from fundamental quantum optics to demonstrate that detectors composed of subwavelength elements interacting collectively with the photon field can achieve high-performance photon number resolution. We propose a new design that simultaneously achieves photon number resolution, high efficiency, low jitter, low dark counts, and high count rate. Finally, we discuss specific systems that satisfy the design requirements, pointing to the important role of nanoscale device elements.

47 OTHER INSTRUMENTATION↗

A cosmic and solar X-ray and gamma-ray instrument for a scout launch

An overview is presented for a set of simple and robust X-ray and gamma ray instruments which have both cosmic and solar objectives. The primary solar scientific objective is the study of the beaming of energetic electrons and ions in solar flares. The instrument will measure spectra and polarization of flare emissions up to 10 MeV. At X-ray energies both the directly emitted flux and the reflected albedo flux will be measured with a complement of six X-ray sensors. Each of these detectors will have a different high Z filter selected to optimize both the energy resolution and high rate capabilities in the energy band 10 to 300 keV. At energies greater than 100 keV seven 7.6 x 7.6 cm NaI and a set of 30 concentric plastic scattering detectors will record the spectra and polarization of electron bremsstrahlung and nuclear gamma rays. All of the components of the instrument are in existence and have passed flight tests for earlier space missions. The instrument will use a spinning solar oriented Scout spacecraft. The NaI detectors will act as a self-modulating gamma ray detector for cosmic sources in a broad angular band which lies at 90 degrees to the Sun-Earth vector and hence will scan the entire sky in 6 months.

Forrest, D. J.↗

Neutrino Oscillations at the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment located at Fermi National Accelerator Laboratory (Fermilab) in Batavia, IL, USA. Its main goal is to extract neutrino oscillation parameters by examining the disappearance of $\nu_\mu \ (\bar{\nu}_\mu)$ and the appearance of $\nu_e \ (\bar{\nu}_e)$ at its far detector. The experiment uses the NuMI beamline at Fermilab, which delivers a high-purity neutrino and antineutrino beam. NOvA consists of two functionally similar, high-resolution liquid scintillator tracking calorimeters, both placed 14.6 milliradians off the beam axis. The near detector, positioned 100 m underground and 1 km from the beam's origin, captures unoscillated $\nu_\mu (\bar{\nu}_\mu)$ and instrinsic beam $\nu_e \ (\bar{\nu}_e)$ events. The far detector, located 810 km away from the beam source in Ash River, Minnesota, measures both unoscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and those that have oscillated into $\nu_\mu \ (\bar{\nu}_\mu) \to \nu_e \ (\bar{\nu}_e)$. This poster will cover the latest results on three-flavor neutrino oscillation parameters, derived from an exposure of neutrino beam of $26.60 \times 10^{20}$ POT and anti-neutrino beam exposure of $12.50\times 10^{20}$ POT including an additional low energy $\nu_e$ sample.

Singh, Ishwar [Delhi U.]↗

Monte Carlo Modeling and Design of Photon Energy Attenuation Layers for >10× Quantum Yield Enhancement in Si-Based Hard X-ray Detectors

High-energy (>20 keV) X-ray photon detection at high quantum yield, high spatial resolution, and short response time has long been an important area of study in physics. Scintillation is a prevalent method but limited in various ways. Directly detecting high-energy X-ray photons has been a challenge to this day, mainly due to low photon-to-photoelectron conversion efficiencies. Commercially available state-of-the-art Si direct detection products such as the Si charge-coupled device (CCD) are inefficient for >10 keV photons. Here, we present Monte Carlo simulation results and analyses to introduce a highly effective yet simple high-energy X-ray detection concept with significantly enhanced photon-to-electron conversion efficiencies composed of two layers: a top high-Z photon energy attenuation layer (PAL) and a bottom Si detector. We use the principle of photon energy down conversion, where high-energy X-ray photon energies are attenuated down to ≤10 keV via inelastic scattering suitable for efficient photoelectric absorption by Si. Our Monte Carlo simulation results demonstrate that a 10–30× increase in quantum yield can be achieved using PbTe PAL on Si, potentially advancing high-resolution, high-efficiency X-ray detection using PAL-enhanced Si CMOS image sensors.

47 OTHER INSTRUMENTATION↗

High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure

High-resolution submillimeter/terahertz spectroscopy is important for studying atmospheric and interstellar molecular gaseous species. It typically uses heterodyne receivers where an unknown (weak) signal is mixed with a strong signal from the local oscillator (LO) operating at a slightly different frequency. The non-linear mixer devices for this frequency range are unique and are not off-the-shelf commercial products. Three types of THz mixers are commonly used: Schottky diode, superconducting hot-electron bolometer (HEB), and superconductor-insulation-superconductor (SIS) junction. A HEB mixer based on the two-dimensional electron gas (2DEG) formed at the interface of two slightly dissimilar semiconductors was developed. This mixer can operate at temperatures between 100 and 300 K, and thus can be used with just passive radiative cooling available even on small spacecraft.

Karasik, Boris S.↗

Studies of Avalanche Photodiodes (APDS) as Readout Devices for Scintillating Fibers for High Energy Gamma-Ray Astronomy Telescopes

New gamma ray and charged particle telescope designs based on scintillating fiber arrays could provide low cost, high resolution, lightweight, very large area and multi radiation length instrumentation for planned NASA space exploration. The scintillating fibers low visible light output requires readout sensors with single photon detection sensitivity and low noise. The sensitivity of silicon Avalanche Photodiodes (APDS) matches well the spectral output of the scintillating fibers. Moreover, APDs have demonstrated single photon capability. The global aim of our work is to make available to NASA a novel optical detector concept to be used as scintillating fiber readouts and meeting the requirements of the new generations of space-borne gamma ray telescopes. We proposed to evaluate the feasibility of using RMD's small area APDs ((mu)APD) as scintillating fiber readouts and to study possible alternative (mu)APD array configurations for space borne readout scintillating fiber systems, requiring several hundred thousand to one million channels. The evaluation has been conducted in accordance with the task description and technical specifications detailed in the NASA solicitation "Studies of Avalanche Photodiodes (APD as readout devices for scintillating fibers for High Energy Gamma-Ray Astronomy Telescopes" (#8-W-7-ES-13672NAIS) posted on October 23, 1997. The feasibility study we propose builds on recent developments of silicon APD arrays and light concentrators advances at RMD, Inc. and on more than 5 years of expertise in scintillating fiber detectors. In a previous program we carried out the initial research to develop a high resolution, small pixel, solid-state, silicon APD array which exhibited very high sensitivity in the UV-VIS spectrum. This (mu)APD array is operated in Geiger mode and results in high gain (greater than 10(exp 8)), extremely low noise, single photon detection capability, low quiescent power (less than 10 (mu)W/pixel for 30 micrometers sensitive area diameter) and output in the 1-5 volt range. If successful, this feasibility study will make possible the development of a scintillating fiber detector with unsurpassed sensitivity, extremely low power usage, a crucial factor of merit for space based sensors and telescopes.

Vasile, Stefan↗

X-Ray Detector Research at MSFC for Space Applications

NASA's Vision for Space Exploration has specific goals aimed at exploring the Solar System. This vision, under presidential mandate includes landing humans on the moon before the end of the next decade, paving the way for eventual journeys to Mars and beyond. The first missions to the moon will be in the form of both Orbiters and Landers, with the goal of paving the way for human return. One of the instruments we are currently working on,in collaboration with Brookhaven National Laboratory, is a lunar orbiter fluorescent x-ray spectrometer to finely map the light elements (down to Carbon) on surface of the moon. Funded NASA s Planetary Instrument Definition and Development Program the instrument is based on silicon drift detector arrays read out by custom ASICs. These offer the promise of high spectral resolution, necessary for resolving weak lines against a strong background continuum, and very low power requirements, necessary for large areas (greater than 500 square centimeters) required for future lunar missions. Further, the inherent radiation hardness of these detectors makes them ideal candidates for exploring the Jovian system, where the harsh radiation environment from Jupiter s radiation belts creates unfavorable detector conditions. Looking beyond our solar system, in the hard x-ray regime (20-80keV.), we are studying Cadmium-Zinc-Telluride pixilated detectors as feasible candidates for focal plane detectors of a hard x-ray telescope. This energy region bridges the gap between thermal and non-thermal x-ray emission from astronomical sources, will allow us to better understand supernovae nucleosynthesis (such as through the Ti-44 lines at 68keV and 78keV), Active Galactic Nuclei and other compact objects, more completely. The detectors that we are characterizing are 2mm in thickness and are pixilated with a 16x16 array of 300 micrometer pitch pixels (50micometer gap). These detectors are designed at Rutherford Appleton Laboratory, material is from eV Products, and polymer flip-chip assembly was performed by a commercial vendor. An energy resolution of 2.0% at 60keV (or better) should allow us to sufficiently distinguish lines of interest from background continuum, and the detector spatial resolution should be fine enough to over-sample the focal spot from the x-ray focusing optics by about a factor of two. Full technical details of these developments will be presented.

Gaskin, Jessica↗

Improving ICARUS track reconstruction algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino program at Fermilab. Its primary objective is to explore the possible existence of sterile neutrinos in the O(1 eV) mass range and to clarify the anomalies observed in the Liquid Scintillator Neutrino Detector and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber, capable of producing high-resolution 3D images and precise calorimetric measurements of ionizing particles. This technology allows for a detailed study of neutrino interactions across a broad energy range, from a few keV to several hundred GeV. The track reconstruction is achieved through a software framework that applies a series of pattern recognition algorithms, transforming raw detector signals into fully reconstructed event topologies. This process involves identifying interaction vertices, particle tracks, and electromagnetic showers within the TPC. However, in certain cases, these algorithms may mistakenly break a single particle track into several shorter segments, interpreting each as a distinct particle. Since track length is used to estimate the particle's energy, such fragmentation can result in an energy underestimation of several hundred MeV. Furthermore, when a track is split into multiple segments, the particle identification (which relies on analyzing the energy loss as a function of the residual range) may fail, potentially leading to the loss of the entire event. To mitigate this problem, we have developed a dedicated algorithm designed to identify and reconnect (“stitch”) the tracks that were erroneously divided into multiple segments.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Effective Area of the AXAF High Resolution Camera (HRC)

The AXAF High-Resolution Camera (HRC) was calibrated at NASA MSFC's X-Ray Calibration Facility (XRCF) during 1997 March and April. We have undertaken an analysis of the HRC effective area using all data presently available from the XRCF. We discuss our spectral fitting of the beam-normalization detectors (BNDs), our method of removing higher order contamination lines present in the spectra, and corrections for beam non-uniformities. We apply a model of photon absorption depth in order to fit a smooth curve to the quantum efficiency of the detector. This is then combined with the most recent model of the AXAF High-Resolution Mirror Assembly (HRMA) to determine the ensemble effective area versus energy for the HRC. We also address future goals and concerns.

Patnaude, Daniel↗

Lithium source for focused ion beam implantation and analysis

In this work, we present a new Li source for focused ion beam applications. Based on an AuSi eutectic alloy, Li is added as an impurity to minimize effects from degradation when exposed to air. We show the source is stable over the course of an hour and spot sizes ≲10 nm can be achieved. The Li beam can achieve hundreds of nanometer ranges in semiconductors with minimal damage being generated along the path length. The source performance is evaluated through a high-resolution ion beam induced charge collection experiment on an Si-based detector. Further application of the source for ion beam analysis is numerically explored; the example investigated is based on probing a semiconductor heterostructure through a Rutherford backscattering experiment, where the Li beam can reveal information that is inaccessible with either low energy or high energy He projectiles used as probes.

36 MATERIALS SCIENCE↗

Broad band X-ray astronomical spectroscopy

The Broad Band X-Ray Telescope (BBXRT) experiment has been designed for high sensitivity, moderate resolution spectrophotometry of cosmic sources in the range 0.5 to 12 keV. Principal elements are two co-aligned imaging telescopes with cooled Si(Li) detectors at each focus. The mirror design uses an approximate geometry of tightly nested, conical, foil reflectors that allow a large filling factor (high throughput) at small grazing angles (high energy response). Each detector consists of a cluster of five elements defined with grooves on a single crystal. This arrangement affords some spatial resolution as well as a means of substantial background reduction. Shuttle borne measurements will typically be of 2000 s duration for sources with a flux of 10 to the -12 erg/sq cm-s.

Serlemitsos, P. J.↗

LBNF/DUNE Cryostats and Cryogenics Infrastructure for the DUNE Far Detector (Design Report)

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on both a near detector and a cryogenic far detector. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines many tens-of-kilotons of fiducial mass with sub-centimeter spatial resolution to collect neutrino events and image them with high precision. Given its size, this detector will be implemented as a set of up to four modules, each of which will require its own cryostat that will contain approximately 17.5 metric kilotons of ultra-pure liquid argon (LAr). The cryogenics infrastructure to support the detector modules includes systems to receive, transfer, store, purify, and maintain the LAr. This design report describes the cryostats and the cryogenics infrastructure required for the first two detector modules; this infrastructure is designed to support expansion to up to four far detector modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Dot Based Solid-State Radiation Detectors

The detection and accurate identification of nuclear material is critical to the advancement of national security, medical technology, and environmental prosperity. The gold standard solid-state detector HPGe, suffers from high manufacturing costs and the need to operate at cryogenic temperatures to ensure reliable energy resolution. The other most common solid-state detector, cadmium zinc telluride (CZT), has the ability to operate at room temperature, but the grow process results in impurities decreasing performance. In this paper we have developed a continuous flow synthesis able to mass produce targeted size cadmium selenide quantum dots. The implementation of these QDs in QD/MEH-PPV composites has the ability to rival HPGe energy resolution at room temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗