Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydrogen detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

HUT observations of carbon monoxide in the coma of Comet Levy (1990c)

Observations of comet Levy (1990c) were made with the Hopkins Ultraviolet Telescope during the Astro-1 Space Shuttle mission on 10 Dec. 1990. The spectrum, covering the wavelength range 415 to 1850 A at a spectral emission of 3 A (in first order), shows the presence of carbon monoxide and atomic hydrogen, carbon, and sulfur in the coma. Aside from H I Lyman-beta, no cometary features are detected below 1200 A, although cometary O I and O II would be masked by the same emissions present in the day airglow spectrum. The 9.4 x 116 arcsec aperture corresponds to 12,000 x 148,000 km at the comet. The derived production rate of CO relative to water, 0.13 + or - 0.02, compared with the same ratio derived from IUE observations (made in Sep. 1990) which sample a much smaller region of the coma, 0.04 + or - 0.01, suggests the presence of an extended source of CO, as was found in comet Halley. Upper limits on Ne and Ar abundance are within an order of magnitude or solar abundances.

Feldman, P. D.↗

Observations of Comet Levy (1990c) with the Hopkins Ultraviolet Telescope

Observations of Comet Levy (1990c) were made with the Hopkins Ultraviolet Telescope during the Astro-1 Space Shuttle mission on December 10, 1990. The spectrum, covering the wavelength range 415-1850 A at a spectral resolution of 3 A, shows the presence of carbon monoxide and atomic hydrogen, carbon, and sulfur in the coma. Aside from H I Lyman-beta, no cometary features are detected below 1200 A, although cometary O I and O II would be masked by the same emissions present in the day airglow spectrum. The 9.4 x 116 arcsecond aperture corresponds to 12,000 x 148,000 km at the comet. The derived production rate of CO relative to water is 0.11 + or - 0.02, compared with 0.04 + or - 0.01 derived from IUE observations (made in September 1990) which sample a much smaller region of the coma. This suggests the presence of an extended source of CO, as was found in comet Halley. Upper limits on Ne and Ar abundance are within one order of magnitude of solar abundances.

Feldman, P. D.↗

An application of a space technique for pollution detection.

Description of the hazardous gas detection system (HGDS) used during Apollo-Saturn launch tests for identifying and analyzing extremely minute amounts of gases escaping during cryogenic loading. These gases included hydrogen, helium, nitrogen, oxygen, nitrogen tetroxide, and hydrazine N2H3 radical. The heart of the HGDS is a mass spectrometer operating under high vacuum and capable to measure both qualitatively and quantitatively the presence and percentage of any gas whose molecular weight is between 2 and 150 atomic mass units. It is suggested that such a system could be utilized to detect environmental pollutants.

Hall, J. J.↗

Spectral energy distributions of the brightest Palomar-Green quasars at intermediate redshifts

We have combined low-dispersion International Ultraviolet Explorer (IUE) spectra with the optical/near-IR spectrophotometry of Neugebauer et al. (1987) in order to study the spectral energy distributions of seven of the brightest Palomar-Green (PG) quasars at intermediate redshifts (Z(sub em) greater than or equal to 0.9 and less than or equal to 1.5). Some of these PG quasars are barely detectable in long IUE exposures, so we have used the Gaussian Extraction (GEX) technique to maximize the signal-to-noise of the IUE data, and we have co-added all spectra available from the IUE archive for each QSO unless the ultraviolet spectra varied significantly from one exposure to the next. We have corrected the spectral energy distributions for Milky Way reddening using the observed neutral hydrogen column densities on each sight line and the gas-to-dust relation recently derived by Diplas & Savage. Six of the seven quasars are detected down to lambda much less than 700 A in the rest frame, and consequently continuum reddening due to dust in the immediate vicinity of the quasar can have a dramatic effect on the spectral energy distributions. In order to explore the possible importance of intrinsic continuum reddening, we have assembled a heuristic extinction curve which extends to lambda much less than 912 A. Using this heuristic extinction curve, we derive reasonable upper limits on the intrinsic E(B-V) for each quasar. We briefly discuss some of the implications of the derived intrinsic continuum reddening limits. We use geometrically thin accretion disk models to derive the black hole masses and accretion rates implied by the spectral energy distributions. Even if we neglect intrinsic reddening, we find that a large fraction of the quasars require super-Eddington accretion rates (which is not consistent with the thin disk assumption). Comparison of the data in this paper to a large body of data from the literature on the accretion disk M(sub BH) - M dot grid calculated by Wandel & Petrosian reveals that our quasars are among the brightest in the sky at 1450 A, and ostensibly suggests that the fraction of quasars which require super-Eddington accretion rates is much smaller than the fraction that we derive from our data alone. However, intrinsic continuum reddening has been ignored in this comparison, and a small amount of intrinsic reddening will push more of the quasars into the super-Eddington regime. We also plot the recent reverberation monitoring results on NGC 5548 and NGC 3783 on the Wandel & Petrosian grid, and we find that these Seyfert galaxies appear to vary along lines of constant M(sub BH). Continuum flux from two of the quasars in our main sample, PG 1338+416 and PG 1630+377, is detected at lambda(sub rest) less than 584 A. These quasars can in principle be used for the He I Gunn-Peterson test, but the S/N of IUE spectra of individual objects is usually too low to place interesting limits on the Gunn-Peterson optical depth. In order to improve the S/N, we have formed a composite spectrum from the spectra of five quasars detected with IUE at lambda(sub rest) less than 584 A, and we have used this composite spectrum to place a tighter limit on tau(sub GP, He I). We briefly discuss intermediate-redshift Lyman limit systems (Z(sub LL) greater than or equal to 0.5 and less than or equal to 1.6) detected in the IUE spectra of five quasars, including lower limits on N(H I) in each Lyman limit system.

Tripp, Todd M.↗

Two techniques for eliminating luminol interference material and flow system configurations for luminol and firefly luciferase systems

Two methods for eliminating luminol interference materials are described. One method eliminates interference from organic material by pre-reacting a sample with dilute hydrogen peroxide. The reaction rate resolution method for eliminating inorganic forms of interference is also described. The combination of the two methods makes the luminol system more specific for bacteria. Flow system designs for both the firefly luciferase and luminol bacteria detection systems are described. The firefly luciferase flow system incorporating nitric acid extraction and optimal dilutions has a functional sensitivity of 3 x 100,000 E. coli/ml. The luminol flow system incorporates the hydrogen peroxide pretreatment and the reaction rate resolution techniques for eliminating interference. The functional sensitivity of the luminol flow system is 1 x 10,000 E. coli/ml.

Thomas, R. R.↗

Carbon-rich particles in Comet Halley

The majority of particles detected in the coma of Comet Halley contain carbon atoms; many of these grains appear to consist preponderately or only of light elements. These light-element particles may be composed of organic compounds. Of the possible combinations of the elements hydrogen, carbon, nitrogen, and oxygen, numerous examples are found of particles containing the combinations (H,C,O,N), (H,C,N), (H,C,O), and (H,C). These results may bear on the recent detection of polyoxymethylene fragments, the observation of cyanojets (CN patterns consistent with release from solid particles), the possible presence of cyanopolyacetylenes or HCN polymer and the make-up of the CHON particles. If cometary matter could reach the surface of the earth without complete disruption, these diverse organic and mixed particles could create unique microenvironments, possibly with significant or even pivotal prebiotic chemical activity. Here a speculative insight into possible relationships between carbon in comets and carbon in life is given, as well as a brief overview of on-going analysis of data from the highly successful Particle Impact Analyzer (PIA) experiment flown on the Giotto spacecraft for the flyby of Comet Halley (development and implementation of PIA was under the direction of J. Kissel of the Max Planck Institute for Kernphysik, Heidelberg). PIA is a time-of-flight analyzer which obtains mass spectra of ions from individual particles impacting on a Pt-Ag foil target within the instrument.

Clark, Benton C.↗

The Summer of Hydrogen

Ground crew veterans at Kennedy Space Center still talk about what they call "the summer of hydrogen"-the long, frustrating months in 1990 when the shuttle fleet was grounded by an elusive hydrogen leak that foiled our efforts to fill the orbiter's external fuel tank. Columbia (STS-35) was on Launch Pad A for a scheduled May 30 launch when we discovered the hydrogen leak during - tanking. The external fuel tank is loaded through the orbiter. Liquid hydrogen flows through a 17-inch umbilical between the orbiter and the tank. During fueling, we purge the aft fuselage with gaseous nitrogen to reduce the risk of fire, and we have a leak-detection system in the mobile launch platform, which samples (via tygon tubing) the atmosphere in and around the vehicle, drawing it down to a mass spectrometer that analyzes its composition. When we progressed to the stage of tanking where liquid hydrogen flows through the vehicle, the concentration of hydrogen approached four percent-the limit above which it would be dangerously flammable. We had a leak. We did everything we could think of to find it, and the contractor who supplied the flight hardware was there every day, working alongside us. We did tanking tests, which involved instrumenting the suspected leak sources, and cryo-loaded the external tank to try to isolate precisely where the leak originated. We switched out umbilicals; we replaced the seals between the umbilical and the orbiter. We inspected the seals microscopically and found no flaws. We replaced the recirculation pumps, and we found and replaced a damaged teflon seal in a main propulsion system detent cover, which holds the prevalve-the main valve supplying hydrogen to Space Shuttle Main Engine 3 -in the open position. The seal passed leak tests at ambient temperature but leaked when cryogenic temperatures were applied. We added new leak sensors-up to twenty at a time and tried to be methodical in our placements to narrow down the possible sources of the problem. We even switched orbiters, sending Columbia back to the Vehicle Assembly Building and bringing out Atlantis, scheduled to fly as STS-38. Two shuttles on their mobile launchers passing in the night was a majestic sight, but not one you want to see if you're trying to get an orbiter launched. None of this told us where the leak was, or if we were dealing with more than one leak source.

Weber, Philip↗

Microbial Monitoring of New Cleanrooms Used to Curate Astrobiologically Relevant Asteroid Samples from Bennu and Ryugu

Introduction: NASA has constructed two new cleanrooms to house materials from the OSRIS-REx and Hayabusa2 missions to the asteroids Ryugu (162173) and Bennu (101955), respectively. In accordance with standard astromaterials curation practices, these cleanrooms will be monitored for particulate contamination and maintained to ISO 5 equivalent standards1. Since the samples in these collections are expected to contain prebiotic organic compounds that may help explain the origin of life on Earth, these labs will also be monitored for organic and biological contamination2. Samples from Ryugu arrived on Earth in December, 2020. After basic characterization in Japan, NASA received a subset of these samples at the astromaterials curation facility in Houston in December of 2021. OSIRIS-REx is expected to return samples in September, 2023. Here we present preliminary microbial monitoring results from monthly monitoring of these new labs and the connected microtomy and staging areas that support them, as they are being commissioned. We also compare these results to baseline values for other astromaterials curation labs. We will also briefly describe additional cleaning efforts employed to reduce the bioburden in these new cleanrooms. Methods: Microbial samples were collected from surfaces using a dry macrofoam swab (Puritan Brand 2518051PFRNDFD). Swabs were also opened in the lab but not touched to any surfaces to function as negative controls. Samples and controls were processed inside a class II biosafety cabinet to avoid inadvertent cross contamination. The swabs were suspended in 15 ml of PBS (Phosphate Buffered Saline) and vortexed for 20 seconds to remove cells from the swab surface. The PBS was used to inoculate Petri dishes filled with TSA (Tryptic Soy Agar), Blood Agar, or Reasoners 2 agar to check for microbial growth. Each plate was inoculated with 0.1 ml of PBS. The TSA and blood agar plates were incubated at 35˚C and the Reasoners 2 agar plates were incubated at 25˚C for seven days. Petri dishes filled with Potato dextrose agar, Saboraud dextrose agar, or Saboraud dextrose agar with 0.1 mg/ml of chloramphenicol, an antibiotic, were used to check for fungal growth. These plates were inoculated with 0.3 ml of PBS and incubated at 30˚C. The remaining PBS was frozen at -80 ˚C for DNA sequencing. After incubation, isolates were counted and reisolated for identification. Isolates were identified using the VITEK23 system or by sequencing a portion of the 16S rRNA gene for bacteria or the ribosomal internal transcribed spacer (ITS) for fungi. Sequencing was performed with an ABI 3500 Sanger sequencer. Results: During our initial sampling, six of the seven sites sampled (86%) displayed bacterial or fungal growth. Samples collected from the staging areas and microtomy labs are not included in this calculation since those areas are maintained at a lower ISO 7 equivalent cleanliness standard. A month later, only three of the seven sites (43%) displayed bacterial growth. No fungal growth was detected in the second sampling. Since new equipment had been introduced to the Hayabusa2 lab since the first round of sampling, an additional three sampling sites were included in the second round of sampling. None of these sites displayed microbial growth. These sites will be included in all future sampling efforts. Bacterial isolates have been identified from the following genera at multiple time points: Micrococcus, Staphylococcus, and Bacillus. Isolates from the genera: Microbacterium, Nocardioides, Methylocystis, and Microvirga were identified in the initial sampling, but were not present at later time points. Identification of fungal isolates is in progress. Results are summarized in Table 1. Discussion: The recovery rate or percentage of positive samples4 was initially 86%, which is higher than the median recovery rate for comparable ISO 5 equivalent curation labs like Stardust (33%), Hayabusa (33%), and Cosmic Dust (50%). However, after a month of operation, the recovery rate for these same sites decreased to 43%, which is similar to what we observe in comparable curation cleanrooms with no microbial control requirements. Adding in the new sampling sites further decreases the recovery rate to 30%. With the reduction in recovery rate, we also observed a decrease in microbial diversity. At the first time point, we observed at least 10 different bacterial species and at least two different fungi. This is a higher diversity than the median values for comparable ISO 5 equivalent labs (2-4 isolates per sampling event). After the second sampling, we observed at least 4 bacterial species and no fungi, which is more consistent with comparable labs. We expect the recovery rate and diversity in both labs to continue to decrease as routine operation continues. We will use ultrapure hydrogen peroxide to disinfect equipment and work areas prior to opening any sample containers. Most of the bacterial and fungal isolates were detected on samples from the cleanroom floors. This is consistent with baseline results from other curation labs. Organisms from the genera Bacillus, Staphylococcus, and Micrococcus that were repeatedly detected are common in cleanrooms and on human skin5,6. These organisms are generally thought to be introduced when people enter the cleanroom. Microbacterium, Nocardioides, and Microvirga have also previously been identified in astromaterials cleanrooms, but not as frequently as Bacillus, Staphylococcus, and Micrococcus. Methylocystis is a novel genus in the astromaterials cleanrooms, but it was identified with low accuracy (93% match in the sequenced region of the 16S rRNA gene) and further work is needed to confirm this identification. Microbacterium is a diverse genus with isolates identified from terrestrial and aquatic sediments. Some species of Microbacterium are capable of degrading complex organic compounds found in crude oil. The presence of these bacteria in the OSIRIS REx and Hayabusa2 cleanrooms should be closely monitored. Methylocystis is a genus of methanotrophic bacteria capable of oxidizing methane. If this identification proves to be correct and it is detected again, it should be closely monitored as well. Under nominal operating conditions, samples should not ever encounter the cleanroom floor or other high traffic areas. If we observe an increase in the bioburden in sensitive work areas that appears to be influenced by organism transfer from high traffic areas like the floors, we can employ additional hydrogen peroxide treatments to disinfect high traffic areas. Routine microbial monitoring of these labs will ensure that NASA’s astromaterials collections remain pristine and useful for scientific study. Table 1. Sampling Locations and Colony Counts Bacterial CFUa Fungal CFU Bacterial CFU Fungal CFU Lab - Location 11/2/2021 11/2/2021 12/13/2021 12/13/2021 H2b-Floor 4 8 1 0 H2-staging pass through 3 0 0 0 H2-microtomy pass through TNTCc 0 0 0 H2 Microscope 1 NA NA 0 0 H2 Microscope 2 NA NA 0 0 H2-Table NA NA 0 0 OREXd- microtomy pass through 0 0 6 0 OREX – Anteroom pass through 0 0 0 0 OREX – Floor 1 2 0 0 OREX Witness Foil Table 3 0 1 0 Staging-Floor 16 0 15 0 Microtomy-Floor 3 0 2 0 a: CFU = Colony Forming Unit b: H2 = Hayabusa2 Lab c: TNTC = too numerous to count d: OREX = OSIRIS-REx Lab References: 1. ISO 14644-1:2015 - Cleanrooms and associated controlled environments -- Part 1: Classification of air cleanliness by particle concentration. 37 (2015). 2. McCubbin, F. M. et al. Space Sci Rev 215, (2019). 3. Pincus, D. H. Encyclopedia of Rapid Microbiological Methods (2005). 4. The United States Pharmacopeial Convention. USP General Chapter <1116> 17, 784–794 (2013). 5. Sheraba, N. S., Yassin, A. S. & Amin, M. BMC Research Notes 3, 278 (2010). 6. Utescher, C. L. de A., Franzolin, M. R., Trabulsi, L. R. & Gambale, V. Brazilian Journal of Microbiology 38, 710–716 (2007).

A B Regberg↗

Transverse auroral ion energization observed on DE-1 with simultaneous plasma wave and ion composition measurements

Simultaneous high-time-resolution plasma-wave and ion-composition measurements obtained with DE-1 during a magnetospheric-cusp crossing on March 15, 1984 and during an evening auroral-zone crossing on January 4, 1984 are reported. The data are presented graphically and characterized in detail, with a focus on the transverse energization of H(+) and O(+) ions. An O(+) distribution observed during the cusp crossing is shown to be well represented by a bi-Maxwellian distribution with temperatures 180 eV parallel and 250 eV perpendicular to the local magnetic field and a bulk flow velocity of 27 km/s up the magnetic-field line. In the auroral-zone data a simultaneous transverse-energy increase is detected in both H(+) and O(+) components in the presence of plasma-wave emissions at multiples of the hydrogen gyrofrequency.

Peterson, W. K.↗

Evaluation of Various Depainting Processes on Mechanical Properties of 2024-T3 Aluminum Substrate

Alternate alkaline and neutral chemical paint strippers have been identified that, with respect to corrosion requirements, perform as well as or better than a methylene chloride baseline. These chemicals also, in general, meet corrosion acceptance criteria as specified in SAE MA 4872. Alternate acid chemical paint strippers have been identified that, with respect to corrosion requirements, perform as well as or better than a methylene chloride baseline. However, these chemicals do not generally meet corrosion acceptance criteria as specified in SAE MA 4872, especially in the areas of non-clad material performance and hydrogen embrittlement. Media blast methods reviewed in the study do not, in general, adversely affect fatigue performance or crack detectability of 2024-T3 substrate. Sodium bicarbonate stripping exhibited a tendency towards inhibiting crack detectability. These generalizations are based on a limited sample size and additional testing should be performed to characterize the response of specific substrates to specific processes.

McGill, P.↗

Chemistry Related to Possible Outgassing Sources on Mars

An earlier paper, Chemical markers of possible hot spots on Mars by A. S. Wong, S. K. Atreya and Th. Encrenaz, explored the modification of the atmosphere of Mars following an influx of methane, sulfur dioxide and hydrogen sulfide (CH4, SO2, H2S) from any outgassing sources which are referred to as hot spots. The feasibility of detection of the new species by Planetary Fourier Spectrometer on Mars Express is reported in a subsequent paper, Atmospheric photochemistry above possible martian hot spots by A. S. Wong, S. K. Atreya, V. Formisano, Th. Encrenaz and N. Ignatiev. This abstract is a follow-up on the previous two papers. Here we treat the effect of any outgassed halogens rigorously. We also make estimates of dilution factors relative to the source location following convection and meridional transport.

A S Wong↗

Two Azimuthally Separated Regions of Cusp Ion Injection Observed via Energetic Neutral Atoms

The low-energy neutral atom (LENA) imager on the IMAGE spacecraft can detect energetic neutral atoms produced by ion injection into the cusp through a charge exchange with the Earth's hydrogen exosphere. We examined the occurrence of the LENA cusp signal during positive IMF B(sub z) in terms of the arrival direction and the IMF clock angle theta(sub CA). Results of statistical analyses show that the occurrence frequency is high on the postnoon side when theta(sub CA) is between approximately 20 degrees and approximately 50 degrees. This is ascribed to ion injection caused by cusp reconnection typical of positive IMF B(sub z). Our results also show that there is another situation of high occurrence frequency, which can be identified with theta(sub CA) of approximately 30 degrees to approximately 80 degrees. When theta(sub CA) is relatively large (60 degrees - 80 degrees), occurrence frequencies are high at relatively low latitudes over a wide extent spanning both prenoon and postnoon sectors. This feature suggests that the ion injection is caused by reconnection at the dayside magnetopause. Its postnoon side boundary shifts toward the prenoon as theta(sub CA) decreases. When theta(sub CA) is less than approximately 50 degrees, the high occurrence frequency exists well inside the prenoon sector, which is azimuthally separated from the postnoon region ascribed to cusp reconnection. The prenoon region, which is thought due to ion injection caused by dayside reconnection, may explain the recent report that proton aurora brightening occurs in the unanticipated prenoon sector of the northern high-latitude ionosphere for IMF B(sub y) greater than 0 and B(sub z) greater than 0.

Abe, M.↗

Detection of Propadiene on Titan

The atmosphere of Titan, the largest moon of Saturn, is rich in organic molecules, and it has been suggested that the moon may serve as an analog for the pre-biotic Earth due to its highly reducing chemistry and existence of global hazes. Photochemical models of Titan have predicted the presence of propadiene (historically referred to as allene), CH2CCH2, an isomer of the well-measured propyne (also called methylacetylene) CH3CCH, but its detection has remained elusive due to insufficient spectroscopic knowledge of the molecule. This has recently been remedied with an updated spectral line list. Here we present the first unambiguous detection of the molecule in any astronomical object, observed with the Texas Echelle Cross Echelle Spectrograph on the NASA Infrared Telescope Facility in 2017 July. We model its emission line near 12 μm and measure a volume mixing ratio of (6.9 ± 0.8) × 10(exp −10) at 175 km, assuming a vertically increasing abundance profile as predicted in photochemical models. Cassini measurements of propyne made during 2017 April indicate that the abundance ratio of propyne to propadiene is 8.2 ± 1.1 at the same altitude. This initial measurement of the molecule in Titan's stratosphere paves the way toward constraining the amount of atomic hydrogen available on Titan, as well as future mapping of propadiene on Titan from 8 m and larger ground-based observatories, and future detection on other planetary bodies.

Propadiene or allene↗

The gaseous component of the disk around Beta Pictoris

Optical spectra of alpha Lyr, alpha PsA, and beta Pic have been obtained at a velocity resolution of 3 km/s. No circumstellar absorption lines of Ca II or Na I are detected toward alpha Lyr or alpha PsA at sensitive limits. In the favorable case of beta Pic, where the circumstellar disk imaged by Smith and Terrile (1984) is seen nearly edge-on, a strong, narrow, circumstellar Ca II K absorption line previously reported by Slettebak (1982) and weaker, still narrower circumstellar Na I D lines are detected. Negative results of high sensitivity also are obtained for the Ca I 4226 A and CH(+) 4232 A lines, along with upper limits on the Zn II 2026, 2062 A doublet from archival IUE spectra. Under assumptions which agree with other well-established observations of the gaseous abundances of calcium and zinc, the total gaseous column density of hydrogen along a radius of the circumstellar disk is between 10 to the 18th and 4 x 10 to the 20th/sq cm. Within the boundaries of the dust disk detected by Smith and Terrile (1984) the total gaseous mass then is less than about 2, or less than 1 percent of the mass of the planetary system. A simplified model of the density distribution in the gaseous disk yields a characteristic total density n(H) of about 100,000/cu cm, which exceeds that of all interplanetary gas at earth's position by a factor of about 10,000.

Hobbs, L. M.↗

Spectral Irradiance Measurements of Simulated Lightning in Planetary Atmospheres

Optical emissions from lightning provide information to estimate the altitude, latitude and longitude of lightning storms, the energy of the discharges, and the production of important trace species such as HCN and C2H2. Knowledge of the spectra of planetary lightning is needed to deduce the total energy dissipated by lightning (and thereby, the production of trace gases) and to help design experiments to detect and track lightning storms. Measurements of the spectral irradiance from approximately 380 to 820 nm are reported for laboratory simulations of lightning in the atmospheres of Venus, Jupiter, and Titan. In our laboratory, laser-induced plasmas (LIP) are used to simulate lightning discharges. This technique avoids contamination of the spectra by elect-ode material and maintains a safe environment while allowing the use of flammable gases, such as hydrogen and methane, found in outer planet atmospheres. The observations were made at I and 5 bars pressure for Venus and Jupiter and at 1 bar for the Titan mixture. At a pressure of one bar, our results show prominent lines from H(sub alpha), H(sub beta), H(sub gamma), and H(sub delta) lines of the Balmer Series of atomic hydrogen, a single line from Helium at 588 nm and strong continuum radiation. At pressures of 5 bars, the H(sub alpha) and H(sub beta) lines are wider, the H(sub gamma), and H(sub delta) lines merge into the continuum because of pressure broadening, and the helium line at 588 nm is no longer visible. The observed spectra of simulated lightning in the venusian atmosphere at 1 and 5 bars shows that the OI multiplet at 777.7 nm dominates the spectra, but weak features due to atomic carbon and singly excited and singly ionized oxygen atoms are also visible. Although lightning has not yet been observed on Titan, it conceivable that some form of lightning discharge could be occurring. Therefore experiments on a Titan atmosphere mixture were conducted. The most prominent features seen in the simulated spectra are the H(sub alpha) at 656 nm. from the dissociation of the methane and two strong features at 740 and 820 nm from singly excited nitrogen atoms. Most of the features between 400 and 656 nm are due to ionized nitrogen atoms. A broad, highly structured feature centered near 389 nm is molecular band radiation from CN molecules formed in the cooling plasma of atomic nitrogen, carbon, and hydrogen. It is observed in the lightning simulations of both the venusian and Titan atmospheres, For Venus, Jupiter, and Titan, narrow spectral features that are ideal for detecting lightning in the presence of sunlight are present in the spectra. These features could allow lightning to be detected and tracked by Earth-based instruments.

Borucki, W. J.↗

The detection of H2 in cool carbon stars

Spectra of several carbon stars in the two micron region are examined and compared with synthetic spectra from model atmospheres. Molecular hydrogen has been directly observed in carbon stars for the first time through the quadrupole 1-0 S(1) line at 4712.9/cm. It is definitely present in several Mira variables, and is definitely not present in several irregular variables and one Mira variable. A discrepancy between the predicted and observed line depths at different temperatures is shown. Resolution of the discrepancy by change of temperature alone would require an upward revision of the present effective temperature scale by at least 600 K. Several possible resolutions of the dilemma are briefly examined.

Goebel, J. H.↗

Texas Spectroscopic Search for Lyα Emission at the End of Reionization. III. The Lyα Equivalent-width Distribution and Ionized Structures at z > 7

Lyα emission from galaxies can be utilized to characterize the ionization state in the intergalactic medium (IGM). We report our search for Lyα emission at z > 7 using a comprehensive Keck/MOSFIRE near-infrared spectroscopic data set, as part of the Texas Spectroscopic Search for Lyα Emission at the End of Reionization Survey. We analyze data from 10 nights of MOSFIRE observations which together target 72 high-z candidate galaxies in the GOODS-N field, all with deep exposure times of 4.5–19 hr. Utilizing an improved automated emission-line search, we report 10 Lyα emission lines detected (>4σ) at z > 7, significantly increasing the spectroscopically confirmed sample. Our sample includes large equivalent-width (EW) Lyα emitters (>50 Å), and additional tentative Lyα emission lines detected at 3σ–4σ from five additional galaxies. We constrain the Lyα EW distribution at z ~ 7.6, finding a significant drop from z ≲ 6, suggesting an increasing fraction of neutral hydrogen (H I) in the IGM in this epoch. We estimate the Lyα transmission through the IGM (=EW(z)~7.6/EW(z~2–6)) and infer an IGM H I fraction (X(HI)) of 49 (+19,-19)% at z ~ 7.6, which is lower in modest tension (>1σ) with recent measurements at z ~ 7.6. The spatial distribution of the detected Lyα emitters implies the presence of a potential highly ionized region at z ~ 7.55, which hosts four Lyα emitters within a ∼40 cMpc spatial separation. The prominence of this ionized region in our data set could explain our lower inferred value of X(HI), though our analysis is also sensitive to the chosen reference Lyα EW distribution values and reionization models.

Intae Jung↗

Detection of nitric oxide in the dark cloud L134N

The first detection of interstellar nitric oxide (NO) in a cold dark cloud, L134N is reported. Nitric oxide was observed by means of its two 2 Pi 1/2, J = 3/2 - 1/2, rotational transitions at 150.2 and 150.5 GHz, which occur because of Lambda-doubling. The inferred column density for L134N is about 5 x 10 to the 14th/sq cm toward the SO peak in that cloud. This value corresponds to a fractional abundance relative to molecular hydrogen of about 6 x 10 to the -8th and is in good agreement with predictions of quiescent cloud ion-molecule chemistry. NO was not detected toward the dark cloud TMC-1 at an upper limit of 3 x 10 to the -8th or less.

Mcgonagle, D.↗