Search NASA⌕ Search

SEARCH · Search NASA

Results for “inverted”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Axion domain walls, small instantons, and non-invertible symmetry breaking

Non-invertible global symmetry often predicts degeneracy in axion potentials and carries important information about the global form of the gauge group. When these symmetries are spontaneously broken they can lead to the formation of stable axion domain wall networks which support topological degrees of freedom on their worldvolume. Such non-invertible symmetries can be broken by embedding into appropriate larger UV gauge groups where small instanton contributions lift the vacuum degeneracy, and provide a possible solution to the domain wall problem. We explain these ideas in simple illustrative examples and then apply them to the Standard Model, whose gauge algebra and matter content are consistent with several possible global structures. Each possible global structure leads to different selection rules on the axion couplings, and various UV completions of the Standard Model lead to more specific relations. As a proof of principle, we also present an example of a UV embedding of the Standard Model which can solve the axion domain wall problem. The formation and annihilation of the long-lived axion domain walls can lead to observables, such as gravitational wave signals. Observing such signals, in combination with the axion coupling measurements, can provide valuable insight into the global structure of the Standard Model, as well as its UV completion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-invertible defects from the Conway SCFT to K3 sigma models. Part I. General results

We initiate the study of supersymmetry-preserving topological defect lines (TDLs) in the Conway moonshine module V f♮ . We show that the tensor category of such defects, under suitable assumptions, admits a surjective but non-injective ring homomorphism into the ring of $\mathbb{Z}$-linear maps of the Leech lattice into itself. This puts strong constraints on possible defects and their quantum dimensions. We describe a simple construction of non-invertible TDLs from orbifolds of holomorphic (super)vertex operator algebras, which yields non-trivial examples of TDLs satisfying our main theorem. We conjecture a correspondence between four-plane-preserving TDLs in V f♮ and supersymmetry-preserving TDLs in K3 non-linear sigma models, which extends the correspondence between symmetry groups to the level of tensor category symmetry. We establish evidence for this conjecture by constructing non-invertible TDLs in special K3 non-linear sigma models.

Conformal Field Models in String Theory↗

Evaluating the Feasibility of Transactive Approach for Voltage Management Using Inverters of a PV Plant

This article evaluates the feasibility of a double-auction-based Transactive Energy System (TES) for engaging the reactive power (Var) capability of inverters in a utility-scale pho¬tovoltaic (PV) plant for voltage management in distribution feed¬ers. In this approach, a PV plant owner (seller) provides Var supply curves in terms of price-quantity pairs consider¬ing the inverters’ P-Q capability, efficiency, opportunity cost for real power curtail¬ment, losses, etc. At the same time, the utility (buyer) proposes Var demand curves in price-quantity pairs exhibiting the marginal price of Var. Then, market clearing points are obtained from the intersection points of supply and demand curves which are then used to create Var dispatch sig-nals from the PV plant. To conduct a fea¬sibility study of this approach, an Australian distribution network with a utility-scale PV plant (capacity 3.275 MWP) is modeled in RSCAD and simu¬lated in real-time on MATLAB, RSCAD-RTDS co-simulation platform using real historical data. Consid¬ering a use case, namely, conservation voltage reduction (CVR), the operational feasibility along with cost-benefit analysis is demonstrated in software-in-the-loop (SIL) and hardware-in-the-loop (HIL) platform. Another use case, exploring the benefit from tap-change reduction of step-voltage-regulator, is investigated. These studies explore further use cases, e.g., PV hosting capacity, network reconfiguration, etc., to be incorporated in TES for experiencing substantial economic benefits.

Alam, Mollah Rezaul↗

2D kinetic-ion simulations of inverted corona fusion targets

Laser-driven “inverted corona” fusion targets have attracted interest as a low-convergence neutron source and platform for studying kinetic physics. The scheme consists of a hollow or gas-filled spherical shell made of deuterated plastic. The shell has one or more laser entrance holes (LEH), resembling a spherical hohlraum. The laser passes through the LEH’s and illuminates the interior surface of the shell, ablating a plasma that travels inward towards the target center. Long ion mean free paths in the converging plasma can lead to significant interpenetration, atomic mix, and other kinetic effects. Here, in this work we report on numerical simulations of inverted corona targets using the kinetic-ion, fluid–electron hybrid particle-in-cell (PIC) approach in 2D RZ geometry. 2D simulations suggest that shape effects do not have a significant impact on plasma evolution and observed yield trends are primarily the result of 1D kinetic mix mechanisms. Simulations are also compared against available experimental data recorded at the OMEGA laser facility. In particular, synthetic x-ray emission images show good qualitative agreement with experimental results, albeit with an apparent timing discrepancy for the two-sided vacuum target. More generally, we demonstrate the potential of hybrid-PIC simulations for full-system modeling and experimental design, including collisional absorption of laser energy, plasma evolution, mix, and fusion burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anomalously strong viscosity behavior in mixed oxy-sulfide Na 4 P 2 S 7-x O x invert glasses

In this paper, the first observations have been made of anomalously strong viscosity behavior and correspondingly strong bulk glass formation and resistance to crystallization in a melt quenched (MQ) prepared series of invert, modifier content greater than the glass former content, mixed oxy-sulfide Na 4 P 2 S 7-x O x , 0 ≤ x ≤ 5, (NaPSO) glasses. We find that these glasses even with 67 mole % modifier, Na 2 S, and only 33 mole% glass former P 2 S 5-x O x , exhibit a calorimetric fragility index, m cal , as small as 29 compared to typical values of ~ 60 to 80 for alkali silicate glasses with > 50 mole% SiO 2 and the theoretical minimum m cal of ~ 15. The m cal values were converted to kinetic viscosity fragility, m vis , values and used with the measured glass transition temperatures, T g s, to produce viscosity curves for the glasses using the Mauro-Yue-Ellison-Gupta-Allan (MYEGA) model. The viscosity of the glass with a minimum m cal value of x = 2.5 was then shown to exhibit a viscosity that was as strong as, and for some compositions stronger than, the viscosity of alkali aluminosilicate glasses which have three dimensional network structures compared to the one dimensional chain structures observed in these MOS invert glasses. Consistent with these small values of fragility indices and therefore predicted higher viscosity above the glass transition temperature, T g , in the supercooled liquid regime, these glasses are also particularly resistant to crystallization. For example, the x = 2.5 glass composition exhibits a crystallization temperature, T C , more than 150K above its T g . We find that the calorimetric fragility of these glasses varies systematically with the extent of network forming bridging oxygens (BOs) in the glasses. The structural change caused by incrementally replacing sulfur with oxygen has been found to have consistent, large effects on the thermal properties.

36 MATERIALS SCIENCE↗

Phase-stabilized 2D/3D hetero-bilayers via lattice matching for efficient and stable inverted solar cells

2D-on-3D (2D/3D) perovskite heterostructures with engineered energy landscapes offer the potential to realize efficient and stable inverted solar cells. However, managing the energy landscape using 2D perovskites with thicker inorganic layers n > 1 necessitates the usage of the chemically unstable methylammonium MA + . Here, we synthesized formamidinium (FA)-rich and pure-FA n = 3 Ruddlesden-Popper (RPP) and Dion-Jacobson perovskite (DJP) single crystals by identifying ligands with suitably lattice-matched organic and inorganic components of the 2D lattice. These crystals were translated onto 3D perovskites as capping layers, forming 2D/3D hetero-bilayers (HBs). Degradation studies revealed that HBs with butylammonium-based RPPs as capping layers rapidly phase segregate into non-perovskites under combined extrinsic stressors, compromising the underlying 3D layer, whereas FA-rich DJPs based on 3-aminomethylpiperidine retain their phase stability. The DJP HBs also possess a favorable energy landscape and electron transport at the 2D/3D interface, enabling inverted solar cells with a champion PCE of 25.33% and remarkable stability.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improving photovoltaic hosting capacity of distribution networks with coordinated inverter control: A case study of the EPRI J1 feeder

Abstract Adding photovoltaic (PV) systems in distribution networks, while desirable for reducing the carbon footprint, can lead to voltage violations under high solar‐low load conditions. The inability of traditional volt‐VAr control in eliminating all the violations is also well‐known. This article presents a novel coordinated inverter control methodology that leverages system‐wide situational awareness to significantly improve hosting capacity (HC). The methodology employs a real‐time voltage‐reactive power (VQ) sensitivity matrix in an iterative linear optimizer to calculate the minimum reactive power intervention from PV inverters needed for mitigating over‐voltage without resorting to active power curtailing or requiring step voltage regulator setting changes. The algorithm is validated using the EPRI J1 feeder under an extensive set of realistic use cases and is shown to provide 3x improvement in HC under all scenarios.

Dalal, Dhaval [School of Electrical, Computer, and↗

Photovoltaic inverter-based quantification of snow conditions and power loss

Snow is a significant challenge for photovoltaic (PV) systems at northern latitudes, where the pace of deployment is rapid but snow-related power losses can exceed 30% of annual production. Accurate snow-related power loss estimation methods for utility-scale sites can support snow mitigation strategies, inform resource planning and validate predictive snow-loss models. This study builds on our previous work on inverter-based detection of snow, and its implications for utility-scale power production, by validating the accuracy of our snow-loss method across different PV sites and system designs and highlighting its value in bringing greater visibility to PV plant operations in winter. Our estimation method is both novel and scalable, requiring only standard monitoring data to correlate snow-related losses with meteorological data. As demonstrated here, our validation method involved three main steps: 1) estimation of performance losses for multiple systems by comparing measured inverter data to modeled data; 2) application of a detection framework to identify which performance losses are snow-related; and 3) comparison of snow-related losses among three utility-scale sites differing in tilt angle. Results show that utility-scale systems at higher tilt angles consistently shed snow more quickly/completely than their lower-tilt counterparts. Further, monthly and seasonal snow losses are inversely and non-linearly correlated with tilt angle when normalized for cumulative snowfall. These results are consistent with the findings of previous studies and support the broad applicability of this method to fixed-tilt utility-scale PV systems around the world that routinely experience snow-related performance losses.

Cooper, Emma C. (ORCID:0000000190554098)↗

Digital Twin of an ANPC inverter with integrated Design-For-Trust

Reducing costs and increasing manufacturing output while creating reliable products are three essential components needed to keep a business competitive. In the past, having an asset that could address these three challenges at the same time would be challenging. However, recent advances in computer processing capabilities coupled with increases to network speeds allowed such a system to become possible; and this is known as a Digital Twin (DT), which represents a virtual copy of a production system or a product. Here, this work exhibits a DT application of an Active Neutral Point Clamped (ANPC) inverter using a controller. The controller emulates the ANPC responses of a new Digital Signal Processing (DSP) firmware and validates this new firmware by using Design-For-Trust (DFTr) characteristics. If the new firmware is malicious, then it should be rejected, thus adding preemptive protection measures for inverter based distributed energy resources.

cybersecurity↗

Harmonic Analysis of Common-mode Reduction Modulation for Three-level Inverter

This paper presents harmonic analysis of common-mode reduction (CMR) modulation for three-level voltage source inverters. The analytical model to calculate the harmonics of CMR modulation with arbitrary PWM sequence is developed. The impact of alternative PWM sequences of CMR modulation on harmonics is investigated. New three-state and four-state PWM sequences of CMR are proposed which spread the energy centered in the carrier frequency in the conventional CMR, and thus reduce the voltage peaks in frequency domain. Experiments are conducted on a three-level neutral point clamped inverter. Experiment results verify the developed analytical model and harmonic analysis.

Chen, Ruirui↗

Region-Based Stability Analysis of Resilient Distribution Systems with Hybrid Grid-Forming and Grid-Following Inverters

In this paper, distribution system stability considering mixed grid-forming (GFM) and grid-following (GFL) inverters is discussed. A holistic small-signal model of the distribution feeder accommodating both GFM and GFL inverters is derived. In contrast to conventional point-by-point stability analysis, a region-based stability assessment approach is proposed and implemented to evaluate small-signal system stability with both GFM and GFL controls. Furthermore, to enhance the computational efficiency, an Artificial Intelligence (AI) assisted Kernel Ridge Regression (KRR) approach is developed to obtain the stability region boundary. Therefore, with the derived stability region, the impact of critical parameters on system stability is intuitively shown, and more importantly, the relationship between the maximum penetration level and the corresponding feasible range of the selected control parameters can be quantified. The proposed approach has been validated using MATLAB/Simulink.

grid-following↗

Small-Signal Stability Support from Dynamically Configurable Grid-Forming/Following Inverters for Distribution Systems

The growth of inverter-based resources (IBRs) in modern power systems can challenge system stability since they do not natively provide inertia, prompting a need to develop new methods to address the potential instabilities. In this paper, a dynamically configurable grid-forming (GFM) and grid-following (GFL) control is proposed, which enables inverters to flexibly transition to support system needs. The operation mode transition between GFM and GFL controls is adopted as an additional degree of control flexibility to adjust the small-signal stability margin. In addition, a holistic and detailed small-signal model for a distribution feeder that captures the dynamics from both synchronous generators (SGs) and IBRs is also derived and used to evaluate the effectiveness of the proposed GFM/GFL controls to augment the system small-signal stability margin. Case studies with varying levels of IBRs were implemented in MATLAB/Simulink to demonstrate the effectiveness of the proposed approach.

grid-following control↗

Microgrid to Microgrid Synchronization with Grid-Forming Inverters: Challenges and Solution

Research on network microgrids has primarily focused on control and optimization. However, application aspects such as microgrid-to-microgrid synchronization have not been fully addressed in existing literature. This paper first addresses the challenges of networking microgrids with grid-forming inverter in droop control. Then, it proposes a pre-synchronization algorithm to improves the synchronization speed and transient stability. To improve the speed, the phase difference between adjacent microgrids is minimized. Transients such as inrush current and oscillations are effectively mitigated by increasing the virtual impedance during interconnection. The proposed strategy allows smooth transitions when reconfiguration of the microgrids is needed. The applicability of this strategy to today’s microgrid systems is demonstrated through a validation in a 480V three-phase network microgrid testbed with commercial-grade inverters, protective devices, and switchgear.

Ferrari Maglia, Max↗

Advancing Dynamic Modeling of Grid-Connected PV Inverter Using Bi-LSTM-Based AI Model

Power electronic converters (PECs) are widely used in modern power systems to facilitate the interconnection between various AC or DC sources and loads. Because of the extensive integration, the power system has grown into a more dynamic system in which the dynamics of the PECs must be adequately modeled. The paper presents a new bidirectional long short-term memory (Bi-LSTM) method for evaluating grid-connected inverter-based resources (IBR) dynamics. The method is tested using real hardware data from a grid -connected commercial inverter in laboratory experiments. Results show the Bi-LSTM model accurately reproduces the detailed IBR model's dynamics, even when the internal structure is unknown and parameters are unknown, preventing the disclosure of the manufacturer's confidential data.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Grey-Box System Identification of Grid-Forming Inverters

This paper demonstrates the use of grey-box system identification methods for simplifying and understanding the nonlinear power dynamics of grid-forming inverters (GFMs). The power and frequency outputs of complex high-order GFM models are fed into system identification software in order to fit them to a predetermined LTI system and learn system parameters such as (synthetic) inertia and droop constants. The same process is then run for a high-order synchronous generator model, and the outputs are fit to the same set of LTI equations. Simulation of a network of GFM inverters with diverse control architecture is also performed for the same process. The intent is threefold: first, to demonstrate the appropriateness of unified LTI models for describing the power and frequency dynamics of individual resources and connected networks, in order to facilitate analysis of larger heterogeneous networked systems; second, to discover the relationship between internal control parameters of GFMs and their externally observed values; and third, to validate that grey-box data-driven system identification techniques can be a valuable tool to discover the values of important parameters in the absence of explicit vendor models.

analytical models↗

Modeling and Simulation of Power-Electronic Inverters in Analog Electronic Circuit Simulators

This paper demonstrates how equivalent-circuit representations of grid-following power-electronic inverters can be realized within a SPICE-based development environment using common circuit components and VerilogA code. This facilitates computationally lean simulations of inverter networks leveraging the strengths of SPICE in large-scale simulations. We validate the approach with time-domain simulations for a modified version of the IEEE standard 118-bus system modeled in Virtuoso (a SPICE-based solver). Simulation results are compared-focusing on accuracy and computation speed-with results from a commonly used power-electronics simulation package. We note a significant decrease in simulation time with comparable signal resolution when simulating the network in SPICE.

Billmeyer, Ryan↗

Modeling of a Networked Community Microgrid with High Solar Penetration Considering Control Dynamics of Inverter-Based Resources

Microgrids help facilitate the integration of renewable energy in distribution-level grids and increase the resilience of the electric grid to extreme weather, especially in rural areas. Compared to traditional microgrids, a networked microgrid leverages multiple grid-forming sources to form a potential meshed grid and is more flexible in operation. This paper demonstrates the simulation modeling of an actual networked microgrid located in Adjuntas, Puerto Rico. The model contains representations of power inverters that connect the battery energy storage systems and photovoltaic generation systems to the networked microgrid and is capable of simulating fast grid transients as well as long-term operation of the networked microgrid. The modeling technique for power inverters allows the time-efficient simulation of the microgrid with a minimal penalty on model accuracy.

Li, Dingrui↗

Inverse Segmented Motor Drive Using Dual ANPC Inverters for Common-Mode Voltage and Neutral-Point Current Cancellation

This article proposes an inverse segmented motor drive (SgMD) utilizing dual active neutral point clamped (ANPC) inverters. In the proposed configuration, the neutral point current and common-mode (CM) voltage is topologically canceled, achieving zero total neutral point current and CM voltage under ideal conditions. Also, the zero total neutral point current minimizes the neutral point voltage imbalance in ANPC inverters. The mechanisms behind neutral point current and CM voltage cancellation in the proposed inverse SgMD are first introduced. The modifications to the motor windings for implementing the inverse SgMD are explained, showing that a standard motor can be readily adapted for the proposed configuration. A space vector modulation (SVM) scheme tailored for the proposed topology is presented, along with a carrier-based implementation. Simulation results validate that the proposed topology can achieve zero total CM voltage and neutral point current. It is also shown that the proposed inverse SgMD can reduce neutral point voltage fluctuation by about 90% and RMS current stress in the dc-link capacitors by about 43% compared to the conventional SgMD.

Lee, Sangwhee [ORNL] (ORCID:0000000335490057)↗