Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionic liquid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Low temperature synthesis of CaO-SiO2 glasses having stable liquid-liquid immiscibility by sol-gel process

Calcium silicate glass compositions lying within the liquid-liquid immiscibility dome of the phase diagram, which could not have been prepared by the conventional melting method, were synthesized by the sol-gel process. Hydrolysis and polycondensation of tetraethyl orthosilicate (TEOS) solutions containing up to 20 mol percent calcium nitrate resulted in the formation of clear and transparent gels. The gel formation time decreased with increase in water:TEOS mole ratio, calcium content, and the reaction temperature. Smaller values of gel times in the presence of calcium nitrate are probably caused by lowering of the ionic charge on the sol particles by the salt present. The gelation activation energy, E(sub gel), was evaluated from temperature dependence of the gel time. Presence of Ca(2+) ions or the water:TEOS mole ratio did not have an appreciable effect on the value of E(sub gel). Presence of glycerol in the solution helped in the formation of crack-free monolithic gel specimens. Chemical and structural changes occurring in the gels, as a function of the heat treatments, have been monitored using DTA, TGA, IR-spectroscopy, x ray diffraction, surface area and pore size distribution measurements.

Bansal, Narottam P.↗

Low temperature synthesis of CaO-SiO2 glasses having stable liquid-liquid immiscibility by the sol-gel process

Calcium silicate glass compositions lying within the liquid-liquid immiscibility dome of the phase diagram, which could not have been prepared by the conventional melting method, were synthesized by the sol-gel process. Hydrolysis and polycondensation of tetraethyl orthosilicate (TEOS) solutions containing up to 20 mol percent calcium nitrate resulted in the formation of clear and transparent gels. The gel formation time decreased with increase in water: TEOS mole ratio, calcium content, and the reaction temperature. Smaller values of gel times in the presence of calcium nitrate are probably caused by lowering of the ionic charge on the sol particles by the salt present. The gelation activation energy, E(sub gel), was evaluated from temperature dependence of the gel time. Presence of Ca(2+) ions or the water:TEOS mole ratio did not have an appreciable effect on the value of E(sub gel). Presence of glycerol in the solution helped in the formation of crack-free monolithic gel specimens. Chemical and structural changes occurring in the gels, as a function of the heat treatments, have been monitored using DTA, TGA, IR-spectroscopy, X-ray diffraction, surface area and pore size distribution measurements.

Bansal, N. P.↗

Deposition, Accumulation, and Alteration of Cl(-), NO3(-), ClO4(-) and ClO3(-) Salts in a Hyper-Arid Polar Environment: Mass Balance and Isotopic Constraints

The salt fraction in permafrost soils/sediments of the McMurdo Dry Valleys (MDV) of Antarctica can be used as a proxy for cold desert geochemical processes and paleoclimate reconstruction. Previous analyses of the salt fraction in MDV permafrost soils have largely been conducted in coastal regions where permafrost soils are variably affected by aqueous processes and mixed inputs from marine and stratospheric sources. We expand upon this work by evaluating permafrost soil/sediments in University Valley, located in the ultraxerous zone where both liquid water transport and marine influences are minimal. We determined the abundances of Cl(-), NO3(-, ClO4(-)and ClO3(-)in dry and ice-cemented soil/sediments, snow and glacier ice, and also characterized Cl(-) and NO3(-) isotopically. The data are not consistent with salt deposition in a sublimation till, nor with nuclear weapon testing fall-out, and instead point to a dominantly stratospheric source and to varying degrees of post depositional transformation depending on the substrate, from minimal alteration in bare soils to significant alteration (photodegradation and/or volatilization) in snow and glacier ice. Ionic abundances in the dry permafrost layer indicate limited vertical transport under the current climate conditions, likely due to percolation of snowmelt. Subtle changes in ClO4(-)/NO3(-) ratios and NO3(-) isotopic composition with depth and location may reflect both transport related fractionation and depositional history. Low molar ratios of ClO3(-)/ClO4(-) in surface soils compared to deposition and other arid systems suggest significant post depositional loss of ClO3(-), possibly due to reduction by iron minerals, which may have important implications for oxy-chlorine species on Mars. Salt accumulation varies with distance along the valley and apparent accumulation times based on multiple methods range from approximately 10 to 30 kyr near the glacier to 70-200 kyr near the valley mouth. The relatively young age of the salts and relatively low and homogeneous anion concentrations in the ice-cemented sediments point to either a mechanism of recent salt removal, or to relatively modern permafrost soils (less than 1 million years). Together, our results show that near surface salts in University Valley serve as an end-member of stratospheric sources not subject to biological processes or extensive remobilization.

cold desert geochemical processes↗

Probing specific ion effects at air-aqueous dibutyl phosphate interfaces using vibrational sum frequency generation spectroscopy

Molecular properties at air–liquid and liquid–liquid interface hold the key to many processes involving molecular transport across phase boundaries from aerosol formation to carbon cycling and material separation using solvent extraction techniques. Using dibutyl phosphate (DBP) as a representative for partially aqueous soluble surfactants, the specific ion effect (SIE) of the Hofmeister series cations Cs + , Na + , Li + , and Mg 2+ on the partition and interaction between surfactant molecules and water molecules in the air–aqueous interface are investigated using vibrational sum frequency generation spectroscopy and surface tension measurements. In the presence of 1 mM and 1M bulk aqueous phase ionic strength salt concentrations, fundamental qualitative relationships are observed for the salting out of DBP relative to bulk aqueous phase nitrate salt concentrations and the specific cations species. At 1 mM ionic strength, the interfacial charge and hence the interfacial potential modulates the electrostatic interactions; in particular, the counter cations partially screen the negatively charged interface induced by the DBP in a direct Hofmeister order. At 1M ionic strength, the electric field at the interface or interfacial potential is effectively neutralized, and the counter cations promote the partitioning of DBP to the interface depending on their specific interaction with the DBP head group and metal ion hydration properties. The present results lay a foundation to study SIEs of heavier metals on hydrophobic-aqueous DBP interfaces.

Louie, Christina [Washington State University, Pul↗

Understanding the impact of SPMAK and PEGPEA in crosslinked PEGDA membranes: Methanol-carboxylate co-transport behavior and correlating structure-physicochemical-transport properties

Investigating multicomponent transport in dense, hydrated polymer membranes is necessary in applications such as fuel cells, electrolyzers, and desalination systems. Of particular interest are photoelectrochemical CO 2 reduction cells (PEC-CRC) which produce liquid products such as alcohols (methanol) and carboxylates (formate, acetate). Flux coupling and competitive sorption behavior of these products (solutes) have been found to affect permselectivity, thereby motivating us to investigate fundamental membrane structure-physicochemical-transport relationships. Past research has shown that systematic tuning of crosslinked cation exchange membranes (CEMs) with charge-neutral monoacrylate monomers containing alkyl and phenyl groups (i.e., poly(ethylene glycol) methacrylate (PEGMA), and poly(ethylene glycol) phenyl ether acrylate (PEGPEA)) can suppress acetate transport (permeability) in co-permeation with methanol. To further investigate this transport behavior and to enhance membrane ionic conductivities, 3-sulfopropyl methacrylate potassium (SPMAK), a sulfonated monoacrylate monomer is incorporated here. SPMAK content is varied with neutral PEGPEA and diacrylate crosslinker, poly (ethylene glycol) diacrylate (PEGDA) of two different chain lengths (n = 10 and 13) to prepare membranes of various compositions. Electrochemical and physicochemical properties including ionic conductivity, ion exchange capacity, and water uptake increase with increasing charged SPMAK content. Different states of water within hydrated membranes are probed using differential scanning calorimetry (DSC), where increasing intermediate (loosely bound) water is observed with increasing hydrophilic SPMAK content. The transport behavior of methanol and carboxylates (formate, acetate, propionate) are investigated, where permeabilities vary as methanol > formate > acetate ≈ propionate. Interestingly, permeabilities decrease with increasing PEGPEA content and are more dependent on solute diffusion than sorption. Permeabilities and diffusivities decrease while permselectivities increase with decreasing PEGDA chain length.

25 ENERGY STORAGE↗

Effect of Anoxic Iron Corrosion on WIPP Brine Geochemistry FY23 Final Report (U)

A 280-day study was completed to evaluate the effect of zero-valent iron (Fe 0 ) on the Waste Isolation Pilot Plant (WIPP) brine geochemistry under anticipated reducing conditions. Hydrogen (H 2 ) gas is expected to be present in the repository after closure due to the anoxic corrosion of a vast quantity of iron contained in the waste forms disposed at WIPP; therefore, a background argon atmosphere containing H 2 was chosen for this study. WIPP groundwater brine pH and E h will impact the mobility and fate of plutonium within the repository. Modeling and laboratory results for Castile WIPP brine indicate that equilibrium fa values relative to the standard hydrogen electrode (SHE) are 40 mV more reducing (i.e., more negative) than those for Salado WIPP brine (-480 mV vs. -440 mV, respectively) because of the higher pH of the Castile brine (pH 9 .3 for Castile vs. pH 8.8 for Salado). The E h and pH data were corrected for the effects of high ionic strength. The experimental results for both brines are consistent with thermodynamic predictions using OLI Systems' Mixed Solvent Electrolyte chemical equilibrium model. The measured and corrected pH and E h data from this study are provided in Table ES-I and Table ES-2, respectively. The experimental study, with four test conditions in triplicate, was performed in a dual glovebox with a nominally 3 vol.% H 2 in argon atmosphere (target H 2 range: 3 ± I vol.%). Simulants containing MgO only ( experimental control) and MgO+Fe 0 (WIPP base case) were prepared for both the Salado and Castile brines. MgO was included in all simulants to account for the use of bulk magnesium oxide in the WIPP repository. Fe 0 was included in some simulants to incorporate the effects of the anoxic corrosion of iron and in-situ hydrogen generation in the study. The brine compositions were developed by Sandia National Laboratory (SNL; Xiong, 2008) and have been used in previous WIPP evaluations. The test method (agitation, etc.) is partially based on ASTM D3987-12. Twelve rounds of periodic measurements of pH and E h were performed over the course of the study. Chemical analysis results for liquids and solids (ICP-MS, ICP-ES, IC Anion, TIC, SEM-EDX) are consistent with the pH, E h , and thermodynamic modeling results. This study included the following conditions that deviate from anticipated post-closure conditions following brine intrusion, but were selected to facilitate bench-scale testing to validate modeling of pH and E h for the post-closure WIP P repository: an anoxic glove box atmosphere containing ≤ 4 vol. % H 2 vs. substantially higher H 2 gas concentrations assumed in the WIPP Performance Assessment (PA); a significantly higher liquid-to-solid test ratio compared to the much lower phase ratio anticipated in the WIP P repository; agitation of the simulant bottles to maximize mass transfer; and finally the use of Fe 0 reagents having a much greater surface area than expected in the WIP P repository. Non-representative conditions were chosen for various reasons such as: to provide bounding conservative results, to provide a margin of safety for testing, or to facilitate simulant sub-sampling and analysis. In a parallel effort, aqueous electrolyte thermodynamic models were developed for the synthetic Salado and Castile brines to inform the experimental design, facilitate laboratory data interpretation, and allow extension of evaluations beyond the parameters tested. Thermodynamic modeling simulations including the MgO and Fe 0 additives that are directly relevant to the experimental measurements (e.g., pH calibration curve, ORP corrections) are included in this report. The measured fa of the simulants was close to the OLI model predictions for both brines and was largely controlled by the background H 2 partial pressure in the vapor phase as well as H 2 generated in situ in the aqueous phase by the Fe 0 corrosion. The H 2 gas-phase concentration tested and thermodynamically evaluated was much lower than is assumed in the WIPP PA; however, H 2 (g) concentrations significantly below this level are still predicted to result in very reducing conditions. In conclusion: • The experimental results are consistent with thermodynamic model predictions for fa, pH, and the effects of high ionic strength. • Evidence to date suggests that the H2 concentration in the glovebox atmosphere ultimately determined the final E h values of the simulants and resulted in highly reducing conditions. As a result, little difference was observed between the control simulants containing only MgO and the WIPP base-case simulants that contained MgO and Fe 0 . • This test methodology is recommended for future studies evaluating WIPP repository conditions. The methodology includes: (1) background H 2 in argon with agitation ( or could alternatively include in-situ-generated H 2 in sealed bottles); (2) carefully measured and corrected ORP data ( with much effort focused on allowing the probes to fully stabilize); and (3) ionic-strength-corrected pH data. Other best practices, such as simulant sparging/handling, ORP probe replacement, etc., should also be considered. • The coupling of experimental studies and thermodynamic modeling is also highly recommended because these methods inform and direct one another leading to greater confidence in and understanding of the results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of an ATP Assay to Quantify Bacterial Attachment to Surfaces in Reduced Gravity

Aim: To develop an assay to quantify the biomass of attached cells and biofilm formed on wetted surfaces in variable-gravity environments. Methods and Results: Liquid cultures of Pseudomonas aeruginosa were exposed to 30-35 brief cycles of hypergravity (< 2-g) followed by free fall (i.e., reduced gravity) equivalent to either lunar-g (i.e., 0.17 normal Earth gravity) or micro-g (i.e., < 0.001 normal Earth gravity) in an aircraft flying a series of parabolas. Over the course of two days of parabolic flight testing, 504 polymer or metal coupons were exposed to a stationary-phase population of P. aeruginosa strain ERC1 at a concentration of 1.0 x 10(exp 5) cells per milliliter. After the final parabola on each flight test day, half of the material coupon samples were treated with either 400 micro-g/L ionic silver fluoride (microgravity-exposed cultures) or 1% formalin (lunar-gravity-exposed cultures). The remaining sample coupons from each flight test day were not treated with a fixative. All samples were returned to the laboratory for analysis within 2 hours of landing, and all biochemical assays were completed within 8 hours of exposure to variable gravity. The intracellular ATP luminescent assay accurately reflected cell physiology compared to both cultivation-based and direct-count microscopy analyses. Cells exposed to variable gravity had more than twice as much intracellular ATP as control cells exposed only to normal Earth gravity.

Birmele, Michele N.↗

High temperature conductivity of potassium-beta(double prime)-alumina

Potassium beta(double prime)-alumina (BDPA) single crystals have been reported by several groups to leave higher ionic conductivity than sodium BDPA crystals at room temperature, and similar conductivities are obtained at temperatures up to 600-700 K. Potassium BDPA ceramics have been reported to have significantly poorer conductivities than those of sodium BDPA ceramics, but conductivity measurements at temperatures above 625 K have not been reported. In this study, K(+)-BDPA ceramics were prepared from Na(+)-BDPA ceramic using a modified version of the exchange reaction with KCl vapor reported by Crosbie and Tennenhouse (1982), and the conductivity has been measured in K vapor at temperatures up to 1223 K, using the method of Cole et al. (1979). The results indicate reasonable agreement with earlier data on K(+)-BDPA ceramic measured in a liquid K cell, but show that the K(+)-BDPA ceramic's conductivity approaches that of Na(+)-BDPA ceramic at higher temperatures, being within a factor of four at 700 K and 60 percent of the conductivity of Na(+)-BDPA at T over 1000 K. Both four-probe dc conductivity and four probe ac impedance measurements were used to characterize the conductivity. A rather abrupt change in the grain boundary resistance suggesting a possible phase change in the intergranular material, potassium aluminate, is seen in the ac impedance behavior.

Williams, R. M.↗

Reducing Ohmic Resistances in Membrane Capacitive Deionization Using Micropatterned Ion-Exchange Membranes, Ionomer Infiltrated Electrodes, and Ionomer-Coated Nylon Meshes

Membrane capacitive deionization (MCDI) is an emerging water desalination platform that is compact, electrified, and does not require high-pressure piping. Herein, highly conductive poly(phenylene alkylene) ion-exchange membranes (IEMs) are micropatterned with different surface geometries for MCDI. The micropatterned membranes increase the interfacial area with the liquid stream leading to a 700 mV reduction in cell voltage when operating at constant current (2 mA cm -2 ; 2000 ppm NaCl feed) while improving the energy normalized adsorbed salt (ENAS) value by 1.4 times. Combining the micropatterned poly(phenylene alkylene) IEMs with poly(phenylene alkylene) ionomer-filled electrodes reduces the cell voltage by 1000 mV and improves the ENAS values by 2.3 times relative to the base case. This reduction in cell voltage allows for higher current density operation (i.e., 3–4 mA cm -2 ) . The reduction in cell voltage is ascribed to the ameliorating ohmic resistances related to ion transport at the membrane-process stream interface and in the carbon cloth electrode. Finally, porous ionic conductors are implemented into the spacer channel with flat and micropatterned IEM configurations and ionomer infiltrated electrodes. For the configuration with flat IEMs, the porous ionic conductor improves ENAS values across the current density regime (2–4 mA cm -2 ), while for micropatterned IEMs it gets improved only at 4 mA cm -2 .

42 ENGINEERING↗

LiGa(OTf)(sub 4) as an Electrolyte Salt for Li-Ion Cells

Lithium tetrakis(trifluoromethane sulfo - nato)gallate [abbreviated "LiGa(OTf)4" (wherein "OTf" signifies trifluoro - methanesulfonate)] has been found to be promising as an electrolyte salt for incorporation into both liquid and polymer electrolytes in both rechargeable and non-rechargeable lithium-ion electrochemical cells. This and other ingredients have been investigated in continuing research oriented toward im proving the performances of rechargeable lithium-ion electrochemical cells, especially at low temperatures. This research at earlier stages, and the underlying physical and chemical principles, were reported in numerous previous NASA Tech Briefs articles. As described in more detail in those articles, lithiumion cells most commonly contain nonaqueous electrolyte solutions consisting of lithium hexafluorophosphate (LiPF6) dissolved in mixtures of cyclic and linear alkyl carbonates, including ethylene carbonate (EC), propylene carbonate (PC), dimethyl carbonate (DMC), diethyl carbonate (DEC), and ethyl methyl carbonate (EMC). Although such LiPF6-based electrolyte solutions are generally highly ionically conductive and electrochemically stable, as needed for good cell performance, there is interest in identifying alternate lithium electrolyte salts that, relative to LiPF6, are more resilient at high temperature and are less expensive. Experiments have been performed on LiGa(OTf)4 as well as on several other candidate lithium salts in pursuit of this interest. As part of these experiments, LiGa(OTf)4 was synthesized by the reaction of Ga(OTf)3 with an equimolar portion of LiOTf in a solvent consisting of anhydrous acetonitrile. Evaporation of the solvent yielded LiGa(OTf)4 as a colorless crystalline solid. The LiGa(OTf)4 and the other salts were incorporated into solutions with PC and DMC. The resulting electrolyte solutions exhibited reasonably high ionic conductivities over a relatively wide temperature range down to 40 C (see figure). In cyclic voltammetry measurements, LiGa(OTf)4 and the other salts exhibited acceptably high electrochemical stability over the relatively wide potential window of 0 to 5 V versus Li+/Li. 13C nuclear-magneticresonance measurements yielded results that suggested that in comparison with the other candidate salts, LiGa(OTf)4 exhibits less ion pairing. Planned further development will include optimization of the salt and solvent contents of such electrolyte solutions and incorporation of LiGa(OTf)4 into gel and solid-state polymer electrolytes. Of the salts, LiGa(OTf)4 is expected to be especially desirable for incorporation into lithium polymer electrolytes, wherein decreased ion pairing is advantageous and the large delocalized anions can exert a plasticizing effect.

Reddy, V. Prakash↗

Coupling Online Conductivity with Offline Ion Chromatography Measurements using the Particle-into-Liquid Sampler

A particle-into-liquid sampler has been combined with a flow through conductivity cell to provide a continuous, non-destructive, online measurement in support of offline ion chromatography analysis. The conductivity measurement provides a rapid assessment of the total ion concentration augmenting the slower batch data from the offline analysis and is developed primarily to assist airborne measurements, where fast time response is essential. A model of the conductivity was developed for measured ions and excellent closure is derived for laboratory-generated aerosols. The PILS-conductivity measurement was extensively tested during the NASA Cloud, Aerosol and Monsoon Processes: Philippines Experiment (CAMP2Ex) across nineteen research flights and the conductivity data was found to augment the temporal capability of the PILS instrument for assessing ionic species, allowing sub-minute variability to be resolved. Through the sampling of a diverse range of ambient aerosol, including biomass burning, fresh and aged urban pollution, the conductivity measurement offered additional useful information to untangle the composition of complex aerosol mixtures, specifically for assessing acidic aerosol conditions.

Ewan Colin Crosbie↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

A lyotropic liquid crystal-templated nanofiltration membrane with thermo- and pH-responsive 3D transport pathway

We produce controlled nanostructured membranes from cross-linking of self-assembled diacrylated poloxamers. At sufficiently high concentrations, poloxamers form lyotropic liquid crystals (LLCs), such as lamellar (L α ), cubic packing of spherical micelles, and hexagonal packing of rod-like micelles in water (H 1 ). We use the H 1 phase as a template to produce orderly packed nanofibrous membranes. The obtained membrane has a continuous 3D transport pathway and can alter its nanofiltration (NF) properties in response to changes in temperature and pH. The formulation includes Pluronic P84-diacrylate (P84DA), a thermoresponsive component that acts as both macromer and structure-directing amphiphile. P84DA facilitates changes in membrane pore size with temperature due to its thermoresponsiveness when it is in contact with water. Furthermore, the precursor contains acrylic acid (AAc) as the charged component, which upon copolymerization with P84DA, not only enables ion separation through Donnan exclusion but also imparts pH-responsive behavior for the separation of ionic species. The membrane performance is studied and compared with a commercial NF membrane (NF270). We show that the synthesized NF membrane has separation properties adjustable with temperature and pH with exceptional resistance to fouling by various solutes due to its highly hydrophilic surface. Furthermore, the membrane shows an outstanding sulfate over chloride ion selectivity, which is a requirement for salt fractionation applications. Deducted from separate experiments, the ideal chloride/sulfate selectivity for magnesium cation is about 2.38 at low ionic strengths. This study is done on a model system to show the capability of incorporating pH-responsiveness in LLC templated membranes, in which the pH-responsive range can be designed by changing the charged groups of comonomer in the formulation.

36 MATERIALS SCIENCE↗

Self-assembled nanofiltration membranes with thermo- and pH-responsive behavior

We produce controlled nanostructured membranes from cross-linking of self-assembled diacrylated poloxamers. At sufficiently high concentrations, poloxamers form lyotropic liquid crystals (LLCs), such as lamellar (L α ), cubic packing of spherical micelles, and hexagonal packing of rod-like micelles in water (H 1 ). We use the H 1 phase as a template to produce orderly packed nanofibrous membranes. The obtained membrane has a continuous 3D transport pathway and can alter its nanofiltration (NF) properties in response to changes in temperature and pH. The formulation includes Pluronic P84-diacrylate (P84DA), a thermoresponsive component that acts as both macromer and structure-directing amphiphile. P84DA facilitates changes in membrane pore size with temperature due to its thermoresponsiveness when it is in contact with water. Furthermore, the precursor contains acrylic acid (AAc) as the charged component, which upon copolymerization with P84DA, not only enables ion separation through Donnan exclusion but also imparts pH-responsive behavior for the separation of ionic species. The membrane performance is studied and compared with a commercial NF membrane (NF270). We show that the synthesized NF membrane has separation properties adjustable with temperature and pH with exceptional resistance to fouling by various solutes due to its highly hydrophilic surface. Furthermore, the membrane shows an outstanding sulfate over chloride ion selectivity, which is a requirement for salt fractionation applications. Deducted from separate experiments, the ideal chloride/sulfate selectivity for magnesium cation is about 2.38 at low ionic strengths. This study is done on a model system to show the capability of incorporating pH-responsiveness in LLC templated membranes, in which the pH-responsive range can be designed by changing the charged groups of comonomer in the formulation.

36 MATERIALS SCIENCE↗

Monitoring of Ionic Silver Biocide with Capacitively-Coupled Contactless Conductivity Detection (C4D)

Monitoring of biocide dosing in spacecraft potable water systems is desirable to ensure dosing system operation and resultant microbial control. Electrolytic conductivity is linearly related to the concentration ionic silver (Ag+, the baseline biocide for future NASA missions) chemically dosed into highly purified water, and could serve as a proxy measurement. Traditional conductivity cells rely on immersed metal or graphite electrodes, which may potentially be subject to significant current-induced or auto-galvanic deposition of Ag+. Furthermore, oxide fouling may potentially induce measurement errors. Capacitively-coupled contactless conductivity detection (C4D) is a promising alternative. C4D uses electrodes placed outside an inert, non-conductive flow path, potentially mitigating such problems. We identified and purchased a commercial C4D system with claimed performance (conductivity range: 20 nS/cm to 4 µS/cm) appropriate for this application. We characterized the instrument’s performance with conductivity standards and Ag+ solutions. We began investigations considering practical and long-term detector operation, including potential current-induced deposition of conductive deposits at the tubing wall. In addition, we designed a side-stream flow system to provide liquid flow through the narrow tubing (1/16” outer diameter) required by the detector and characterized the performance of the combined C4D detector/flow system. Finally, we completed theoretical modeling of expected conductivity change with multiple dosing techniques and water chemistries.

Lance Dean Delzeit↗

Liquid Metering Centrifuge Sticks (LMCS): A Centrifugal Approach to Metering Known Sample Volumes for Colorimetric Solid Phase Extraction (C-SPE)

Phase separation is one of the most significant obstacles encountered during the development of analytical methods for water quality monitoring in spacecraft environments. Removing air bubbles from water samples prior to analysis is a routine task on earth; however, in the absence of gravity, this routine task becomes extremely difficult. This paper details the development and initial ground testing of liquid metering centrifuge sticks (LMCS), devices designed to collect and meter a known volume of bubble-free water in microgravity. The LMCS uses centrifugal force to eliminate entrapped air and reproducibly meter liquid sample volumes for analysis with Colorimetric Solid Phase Extraction (C-SPE). C-SPE is a sorption-spectrophotometric platform that is being developed as a potential spacecraft water quality monitoring system. C-SPE utilizes solid phase extraction membranes impregnated with analyte-specific colorimetric reagents to concentrate and complex target analytes in spacecraft water samples. The mass of analyte extracted from the water sample is determined using diffuse reflectance (DR) data collected from the membrane surface and an analyte-specific calibration curve. The analyte concentration can then be calculated from the mass of extracted analyte and the volume of the sample analyzed. Previous flight experiments conducted in microgravity conditions aboard the NASA KC-135 aircraft demonstrated that the inability to collect and meter a known volume of water using a syringe was a limiting factor in the accuracy of C-SPE measurements. Herein, results obtained from ground based C-SPE experiments using ionic silver as a test analyte and either the LMCS or syringes for sample metering are compared to evaluate the performance of the LMCS. These results indicate very good agreement between the two sample metering methods and clearly illustrate the potential of utilizing centrifugal forces to achieve phase separation and metering of water samples in microgravity.

Gazda, Daniel B.↗

Efficient machine learning interatomic potentials robust for liquid and multiple solid polymorphs of NaF and KF

Achieving atomic-level understanding of crystallization of molten salts is of importance to a wide range of technological applications. Recent work [Fan et al., Proc. Natl. Acad. Sci. USA 122, e2425702122 (2025)] revealed that crystal nucleation in molten LiF salt is a multistage process according to the molecular-dynamics (MD) simulations based on an atomic cluster expansion (ACE) machine-learning interatomic potential (MLIP). In order to understand the influence of increasing cation size on nucleation pathways and nucleation rates of molten fluoride salts, here we develop two new ACE MLIPs for NaF and KF. The two ACE MLIPs feature DFT-SCAN-level accuracy for liquid and multiple solid polymorphs over a wide temperature (0–2000 K) and pressure (0–100 GPa) range, and also reproduce well a number of experimental data for solid and liquid equilibrium properties. The efficiency of the two ACE MLIPs enable million-atom-scale or microsecond-scale MD simulations. The two general-purpose ACE MLIPs are expected to be useful for atomistic simulations for different purposes, in addition to studying crystallization of molten NaF and KF salts.

Crystal melting↗

Progress in Development of Improved Ion-Channel Biosensors

Further improvements have recently been made in the development of the devices described in Improved Ion-Channel Biosensors (NPO-30710), NASA Tech Briefs, Vol. 28, No. 10 (October 2004), page 30. As discussed in more detail in that article, these sensors offer advantages of greater stability, greater lifetime, and individual electrical addressability, relative to prior ion-channel biosensors. In order to give meaning to a brief description of the recent improvements, it is necessary to recapitulate a substantial portion of the text of the cited previous article. The figure depicts one sensor that incorporates the recent improvements, and can be helpful in understanding the recapitulated text, which follows: These sensors are microfabricated from silicon and other materials compatible with silicon. Typically, the sensors are fabricated in arrays in silicon wafers on glass plates. Each sensor in the array can be individually electrically addressed, without interference with its neighbors. Each sensor includes a well covered by a thin layer of silicon nitride, in which is made a pinhole for the formation of a lipid bilayer membrane. In one stage of fabrication, the lower half of the well is filled with agarose, which is allowed to harden. Then the upper half of the well is filled with a liquid electrolyte (which thereafter remains liquid) and a lipid bilayer is painted over the pinhole. The liquid contains a protein that forms an ion channel on top of the hardened agarose. The combination of enclosure in the well and support by the hardened agarose provides the stability needed to keep the membrane functional for times as long as days or even weeks. An electrode above the well, another electrode below the well, and all the materials between the electrodes together constitute a capacitor. What is measured is the capacitive transient current in response to an applied voltage pulse. One notable feature of this sensor, in comparison with prior such sensors, is a relatively thick dielectric layer between the top of the well and the top electrode. This layer greatly reduces the capacitance of an aperture across which the ion channels are formed, thereby increasing the signal-to-noise ratio. The use of a relatively large aperture with agarose support makes it possible to form many ion channels instead of only one, thereby further increasing the signal-to-noise ratio and effectively increasing the size of the available ionic reservoir. The relatively large reservoir makes it possible to measure AC rather than DC. This concludes the recapitulation from the cited previous article.

Nadeau, Jay L.↗