Search NASASearch

SEARCH · Search NASA

Results for “lhs-1”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

490 records · Page 26

The active CGCG 077-102 NED02 galaxy within the Abell 2063 galaxy cluster

Context.Within the framework of investigating the link between the central super massive black holes in the cores of galaxies and the galaxies themselves, we detected a variable X-ray source in the center of CGCG 077-102 NED02, which is a member of the CGCG 077-102 galaxy pair within the Abell 2063 cluster of galaxies. Aims.Our goal is to combine X-ray and optical data to demonstrate that this object harbors an active super massive black hole in its core, and to relate this to the dynamical status of the galaxy pair within the Abell 2063 cluster. Methods.We usedChandraandXMM-Newtonarchival data to derive the X-ray spectral shape and variability. We also obtained optical spectroscopy to detect the expected emission lines that are typically found in active galactic nuclei. Finally, we used public ZTF imaging data to investigate the optical variability. Results.There is no evidence of multiple X-ray sources or extended components within CGCG 077-102 NED02. Single X-ray spectral models fit the source well. We detect significant, nonrandom inter-observation 0.5–10 keV X-ray flux variabilities, for observations separated by ∼4 days for short-term variations and by up to ∼700 days for long-term variations. Optical spectroscopy points toward a passive galaxy for CGCG 077-102 NED01 and a Seyfert for CGCG 077-102 NED02. The classification of CGCG 077-102 NED02 is also consistent with its X-ray luminosity of over 10 42 erg s −1 . We do not detect short-term variability in the optical ZTF light curves. However, we find a significant long-term stochastic variability in theg-band that can be well described by the damped random walk model with a best-fit characteristic damping timescale ofτ DRW = 30 −12 +28 days. Finally, the CGCG 077-102 galaxy pair is deeply embedded within the Abell 2063 potential, with a long enough history within this massive structure to have been affected by the influence of this cluster for a long time. Conclusions.Our observations point toward a moderately massive black hole in the center of CGCG 077-102 NED02 of ∼10 6 M ⊙ . As compared to another similar pair in the literature, CGCG 077-102 NED02 is not heavily obscured, perhaps because of the surrounding intracluster medium ram-pressure stripping.

Astronomy & Astrophysics

Photoelectrochemical Proton-Coupled Electron Transfer of TiO 2 Thin Films on Silicon

TiO 2 thin films are often used as protective layers on semiconductors for applications in photovoltaics, molecule–semiconductor hybrid photoelectrodes, and more. Experiments reported here show that TiO 2 thin films on silicon are electrochemically and photoelectrochemically reduced in buffered acetonitrile at potentials relevant to photoelectrocatalysis of CO 2 reduction, N 2 reduction, and H 2 evolution. On both n-type Si and irradiated p-type Si, TiO 2 reduction is proton-coupled with a 1e – :1H + stoichiometry, as demonstrated by the Nernstian dependence of the Ti 4+/3+ E 1/2 on the buffer pK a . Experiments were conducted with and without illumination, and a photovoltage of ∼0.6 V was observed across 20 orders of magnitude in proton activity. The 4 nm films are almost stoichiometrically reduced under mild conditions. The reduced films catalytically transfer protons and electrons to hydrogen atom acceptors, based on cyclic voltammogram, bulk electrolysis, and other mechanistic evidence. TiO 2 /Si thus has the potential to photoelectrochemically generate high-energy H atom carriers. Characterization of the TiO 2 films after reduction reveals restructuring with the formation of islands, rendering TiO 2 films as a potentially poor choice as protecting films or catalyst supports under reducing and protic conditions. Altogether, this work demonstrates that atomic layer deposition TiO 2 films on silicon photoelectrodes undergo both chemical and morphological changes upon application of potentials only modestly negative of RHE in these media. While the results should serve as a cautionary tale for researchers aiming to immobilize molecular monolayers on “protective” metal oxides, the robust proton-coupled electron transfer reactivity of the films introduces opportunities for the photoelectrochemical generation of reactive charge-carrying mediators.

Electrodes

Tuning the Mechanical Properties of Crosslinked Copolymers via Sequence and Solvent‐Selective Swelling for Vat Photopolymerization

Block copolymers (BCPs) offer distinct advantages for vat photopolymerization by enabling mechanically programmable network structures through microphase-separated morphologies that can be kinetically trapped during curing, yielding properties unattainable in homogeneous resins. However, the respective roles of repeat-unit sequence and solvent environment, together with their interplay in directing network formation and mechanical performance, remain unclear. Here, we synthesize a series of CO 2 -based polycarbonate copolymers comprising a crosslinkable glassy poly(vinyl cyclohexene carbonate) (PVCHC, A block) and a non-crosslinkable soft poly(propylene carbonate) (PPC, B block). The polymer sequence is systematically varied (ABA, BAB, and statistical), and solvent choice controls block-selective swelling to jointly control gelation behavior, microphase morphology, and mechanical response through changes in the accessibility and local environment of photocrosslinkable vinyl groups during network formation, as revealed by photorheology and small angle x-ray scattering. By tuning polymer sequence and curing solvent, we transform nominally identical formulations from brittle to highly ductile materials, achieving a three-orders-of-magnitude range in toughness (0.003 to 9.1 MJ m −3 ). These results establish clear structure–processing–property relationships and identify polymer sequence and selective solvation as powerful strategies for programming both printability and performance of block copolymer resins for additive manufacturing.

additive manufacturing

Understanding Discharge‐Driven Growth of Cathode Impedance in Ni‐Rich NMC Cathodes

Degradation of LiNi x Mn y Co 1-x-y O 2 (NMC)-based lithium-ion batteries depends strongly on cut-off voltage ranges. In addition to the high upper cut-off voltage, a high depth of discharge (i.e., lower cut-off voltage) significantly worsens cathode impedance growth and capacity fade during long-term cycling. However, there is currently no consensus on the mechanism behind the negative role of a deep discharge. Here, this phenomenon was investigated in graphite||NMC cells with single-crystal cathodes (LiNi 0.6 Co 0.2 Mn 0.2 O 2 (NMC622) or LiNi 0.76 Co 0.14 Mn 0.10 O 2 (NMC76)) using targeted aging protocols (constant high-voltage holds vs. charge–discharge cycling), while monitoring transition-metal (TM) dissolution, cathode-electrolyte interface (CEI) impedance, and NMC surface composition. We demonstrate a correlation between discharge-driven CEI impedance growth and increased TM dissolution. Furthermore, this degradation pathway is more pronounced in lower-Ni NMC622 than in higher-Ni (NMC76) under comparable delithiation states at charge, with both compositions undergoing the H2→H3 phase transition. X-ray photoelectron spectroscopy (XPS) reveals NMC composition-dependent evolution of surface lattice oxygen and restructured surface layer composition between charged and discharged states. These findings add mechanistic depth to the role of discharge as an active driver of interfacial degradation and provide new insights into its composition dependence.

25 ENERGY STORAGE

Advancing Protein Display on Bacterial Spores through an Extensive Survey of Coat Components

The profound stability of bacterial spores makes them a promising platform for biotechnological applications like biocatalysis, bioremediation, drug delivery, etc. However, though the Bacillus subtilis spore is composed of >40 types of proteins, only ∼12 have been explored as fusion carriers for protein display. Here, we assessed the suitability of 33 spore proteins (SPs) as enzyme display carriers by direct allele tagging at native genomic loci. Of the 33 SPs investigated, 26 formed functional fusions with β-glucuronidase (GUS)─a ∼272 kDa homotetramer. This almost triples the number of SPs assessed for enzyme display and doubles the number of functional fusions documented in the literature. We quantitatively assessed 1) SP promoter activation dynamics, 2) GUS activity on spores, 3) surface availability, and 4) protection from thermal and proteolytic degradation. Multicopy expression and pairwise coexpression of the most promising SP-GUS fusions highlighted the complexity of spore structure/assembly and the difficulty in predicting compatibility between different SP fusions. We also assessed the suitability of engineered spores to degrade PET (polyethylene terephthalate) films and found that surface-exposed SPs were most effective. Beyond the broad survey, a key outcome of our work was the identification of SscA (small spore coat assembly protein A) as an effective spore display carrier. SscA supported enzyme activity at least 4-fold higher than any other SP, including the well-established anchor, CotY. We attribute this to its promoter, which demonstrated early and sustained activation relative to other SPs and its small size (∼3 kDa), which likely minimally interferes with enzyme folding, oligomerization, and activity. Labeling and genetic studies, its hydrophobic nature, and low surface availability suggest that SscA assembles within the inner spore coat, which makes it stabilizing and suitable for many biocatalytic applications. Overall, this work serves as a knowledge base to advance the biotechnological utility of B. subtilis spores.

Bacillus subtilis

Deep Learning and Photogrammetric Reconstruction for Automated Crack Detection and Dimensional Measurement in Mining Operations

Surface crack detection and dimensional measurement at active mining sites present significant safety and operational challenges. Manual inspection methods are labor-intensive, spatially incomplete, and expose personnel to hazardous environments, while existing automated approaches have been developed primarily for concrete civil infrastructure and have not been validated on the complex, variable surfaces characteristic of mining environments. This dissertation presents an automated pipeline that integrates deep learning semantic segmentation with Structure-from-Motion photogrammetry to detect surface cracks and measure their aperture, length, and vertical displacement from standard RGB imagery acquired during routine Uncrewed Aerial Vehicle (UAV) survey operations, without requiring additional sensor hardware or manual measurement. The pipeline combines a U-Net architecture with an EfficientNet-B0 encoder, pretrained on the SDNET2018 concrete crack dataset and fine-tuned on a mining-specific dataset spanning laboratory concrete specimens, coal refuse impoundment embankments, and post-blast limestone quarry benches. Photogrammetric reconstruction is performed using COLMAP Structure-from-Motion and Multi-View Stereo, with crack segmentation masks projected into the reconstructed point cloud to enable three-dimensional vertical displacement measurement through local plane fitting and bimodal surface detection. The pipeline was validated across 36 controlled laboratory specimens at three imaging distances and four vertical displacement levels, achieving aperture measurement RMSE of 0.047 cm and R² of 0.954, and vertical displacement RMSE of 0.140 cm and R² of 0.966, against independent caliper measurements. Field application at a coal refuse impoundment in southwestern Pennsylvania detected 71 crack components across the embankment crest, with a dominant longitudinal crack exhibiting aperture values reaching 28 cm and a 95th percentile vertical displacement of 35.53 cm, consistent in magnitude and spatial distribution with simultaneously acquired LiDAR-derived estimates. Application across four post-blast limestone quarry bench datasets in California successfully characterized blast-induced fracture networks at ground sampling distances ranging from 0.59 to 1.23 cm/pixel, with detected crack geometries physically consistent with observable surface conditions at each site. The results demonstrate that deep learning-based crack detection and photogrammetric measurement can be integrated into routine UAV inspection workflows at mining sites, providing repeatable, scalable, and quantitative crack characterization across surface types, crack scales, and displacement magnitudes not previously addressed in the literature. The pipeline requires no dedicated surveying equipment beyond the UAV platforms already deployed at mine sites for survey and monitoring purposes, supporting practical adoption within existing operational workflows.

Crack detection, Dimensional Measurement

Visualizing Crystallization Dynamics and Transformation Pathways of Disordered Rocksalt Oxides During Thermally Activated Sol–Gel Synthesis

Sol–gel synthesis is a wet-chemical processing route for fabricating functional materials with control over composition and microstructure at relatively low temperatures compared to conventional solid-state synthesis. While sol–gel process initiates with intermixed molecular precursors, the early-stage nucleation pathways are insufficiently understood. Here, in this study, the chemical and structural transformation of ion disordered rocksalt (DRX) Li 1.2 Mn 0.4 Ti 0.4 O 2 (LMTO), a promising cathode material for lithium batteries, is studied by multiscale characterizations. In situ heating transmission electron microscopy (TEM) using a liquid cell visualizes and identifies crystallization pathways at the nanoscale. While some regions follow a classical multi-step transition through thermodynamically stable intermediates, others exhibit a kinetic shortcut via a localized amorphous matrix to directly form the DRX structure. Macroscale Fourier transform infrared spectroscopy corroborates the findings and reveals that transition metal ions are more strongly incorporated into the acetate-coordinated network than lithium. Although in situ heating TEM captures diverse local transformation pathways, in situ synchrotron X-ray diffraction indicates that the macroscopic transformation proceeds predominantly through spinel LMTO and lithium titanates toward DRX-LMTO. The findings uncover the spatiotemporal chemical and structural transformations in sol–gel derived DRX-LMTO materials, and call for fine-tuning of such sol–gel chemistries to manipulate the crystallization pathways and achieve target material homogeneity more efficiently.

cathode material

Mild-Annealed Molecular Layer Deposition (MLD) Tincone Thin Film as Photoelectrochemically Stable and Efficient Electron Transport Layer for Si Photocathodes

Metalcone thin films, composed of inorganic–organic hybrids, are synthesized using molecular layer deposition (MLD) through reactions between organometallic precursors (e.g., Sn, Al, and Ti) and organic reactants (e.g., ethylene glycol and glycerol). Despite their unique properties, metalcones exhibit significant vulnerability to water due to their organic components, limiting their potential in electrochemical applications. This study focuses on enhancing the photoelectrochemical stability of tincone thin films in aqueous electrolyte while preserving their hybrid characteristics through mild annealing in air at 250 °C. As-deposited and vacuum-annealed tincone thin films exhibited significant degradation under these conditions, while high-temperature-annealed (500 °C) tincone thin films offered improved stability with a significant decline in charge transfer efficiency. In contrast, mild annealing in air maintained the C–O bond at half level and improved the stability and charge transport without compromising the unique characteristics of tincone. This was confirmed by ellipsometry, X-ray photoelectron spectroscopy (XPS), and Fourier transform infrared spectroscopy (FTIR). Mild-annealed tincone deposited on a lightly doped p-type silicon (p-Si) photocathode produced a 20-fold increase in CO volume compared to high-temperature annealed tincone in a CO 2 -saturated potassium bicarbonate (KHCO 3 ) electrolyte with dispersed graphene oxide–cobalt phthalocyanine (GO-CoPc) under 1 sun illumination at 0.9 V vs reversible hydrogen electrode (RHE), while maintaining the faradaic efficiency for CO and H 2 . These results suggest that mild-annealed tincone thin films hold significant potential as protective charge transport layers on silicon photocathodes for the aqueous CO 2 reduction reaction (CO 2 RR).

Annealing (metallurgy)

Model-based, in-situ, non-destructive qualification and certification of parts made by autonomous additive manufacturing

To address the significant productivity challenges associated with the qualification and certification (Q&C) tasks of additively manufactured (AM) parts, which have traditionally relied on rigorous post‐build inspection and testing, we propose an integrated framework that combines model‐based qualification and certification (MBQ&C) with autonomous additive manufacturing (AAM). MBQ&C employs high‐fidelity predictive models, developed within the Integrated Computational Materials Engineering (ICME) paradigm, to simulate process–structure–property–performance relationships for assessing a part’s fitness for use. Since predictive models are commonly machine learning (ML)-based or reduced-order surrogates of validated physics models, they run efficiently, enabling timely inference. In parallel, the self-driving AAM utilises ML-based adaptive, closed‐loop control strategies to avoid, mitigate, or repair defects and anomalies during fabrication, thereby increasing the likelihood of producing acceptable parts. A key feature of the combined AAM-MBQ&C framework is that predictive models explicitly incorporate defects or anomalies that persist after the build, using instance-specific data captured via in-situ sensing. This customisation enables a build‐specific assessment of fitness for use, rather than relying on nominal or generic parameters. Such individualised evaluation provides a robust basis for Q&C-related acceptance decisions relating to each build. Additionally, the rapid solution capabilities of ML or reduced-order models enable the determination of a part’s suitability for service shortly after build completion. As the framework matures, it has the potential to substantially reduce reliance on conventional point‐design approaches—such as time‐consuming post‐build computed tomography scanning and costly destructive testing. Thus, the AAM-MBQ&C framework represents a transformative, scalable strategy for quality assurance of AM components, as parts produced within a stable, validated, and certified envelope can be certified with reduced testing. Key benefits include: (1) significant gains in Q&C productivity through efficient, model-centric assessment; (2) performance-based classification of defects into critical and non-critical categories; (3) the ability to predict potential deviations in the performance of parts affected by real-time, adaptive process control interventions relative to those produced under a certified process, and (4) the enabling of virtual Q&C for service environments that are difficult, hazardous, or impractical to access or reproduce experimentally. Collectively, these capabilities strengthen the business case for AM, particularly for high‐consequence and mission‐critical applications. Finally, although this work focuses on powder-based AM, the proposed techniques could be extended to AM processes employing alternative feedstock forms.

Gunasegaram, Dayalan

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

The SRG/eROSITA All-Sky Survey: Optical identification and properties of galaxy clusters and groups in the western galactic hemisphere

The first SRG/eROSITA All-Sky Survey (eRASS1) provides the largest intracluster medium-selected galaxy cluster and group catalog covering the western Galactic hemisphere. Compared to samples selected purely on X-ray extent, the sample purity can be enhanced by identifying cluster candidates using optical and near-infrared data from the DESI Legacy Imaging Surveys. Using the red-sequence-based cluster findereROMaPPer, we measured individual photometric properties (redshiftz λ , richnessλ, optical center, and BCG position) for 12000 eRASS1 clusters over a sky area of 13 116 deg 2 , augmented by 247 cases identified by matching the candidates with known clusters from the literature. The median redshift of the identified eRASS1 sample isz= 0.31, with 10% of the clusters atz> 0.72. The photometric redshifts have an accuracy ofδz/(1 +z) ≲ 0.005 for 0.05 specand velocity dispersionσ) were measured a posteriori for a subsample of 3210 and 1499 eRASS1 clusters, respectively, using an extensive compilation of spectroscopic redshifts of galaxies from the literature. We infer that the primary eRASS1 sample has a purity of 86% and optical completeness >95% forz> 0.05. For these and further quality assessments of the eRASS1 identified catalog, we applied our identification method to a collection of galaxy cluster catalogs in the literature, as well as blindly on the full Legacy Surveys covering 24069 deg 2 . Using a combination of these cluster samples, we investigated the velocity dispersion-richness relation, finding that it scales with richness as log(λ norm ) = 2.401 × log(σ) − 5.074 with an intrinsic scatter ofδ in = 0.10 ± 0.01 dex. The primary product of our work is the identified eRASS1 cluster catalog with high purity and a well-defined X-ray selection process, opening the path for precise cosmological analyses presented in companion papers.

Astronomy & Astrophysics

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

Thermal Disorder‐Induced Strain and Carrier Localization Activate Reverse Halide Segregation

The reversal of halide ions is studied under various conditions. However, the underlying mechanism of heat-induced reversal remains unclear. This work finds that dynamic disorder-induced localization of self-trapped polarons and thermal disorder-induced strain (TDIS) can be co-acting drivers of reverse segregation. Localization of polarons results in an order of magnitude decrease in excess carrier density (polaron population), causing a reduced impact of the light-induced strain (LIS – responsible for segregation) on the perovskite framework. Meanwhile, exposing the lattice to TDIS exceeding the LIS can eliminate the photoexcitation-induced strain gradient, as thermal fluctuations of the lattice can mask the LIS strain. Under continuous 0.1 W cm -2 illumination (upon segregation), the strain disorder is estimated to be 0.14%, while at 80 °C under dark conditions, the strain is 0.23%. However, in situ heating of the segregated film to 80 °C under continuous illumination (upon reversal) increases the total strain disorder to 0.25%, where TDIS is likely to have a dominant contribution. Therefore, the contribution of entropy to the system's free energy is likely to dominate, respectively. Various temperature-dependent in situ measurements and simulations further support the results. These findings highlight the importance of strain homogenization for designing stable perovskites under real-world operating conditions.

36 MATERIALS SCIENCE

Postanaerobic Digestion Manure Fibers as a Renewable Source of Lignin-Derived Aromatic Compounds for Microbial Upgrading

Abstract Postanaerobic digestion manure fibers are an abundant solid residue that remains underutilized. The substantial lignocellulosic content of digested manure opens the possibility of using it as a renewable resource for producing valuable products. In this study, we performed compositional and nuclear magnetic resonance analyses to determine lignin content and aromatic composition of these fibers. Additionally, alkaline-based treatment and reductive catalytic fractionation were evaluated as two different processes to produce aromatic-rich streams. The liquor from the alkaline treatment was subsequently utilized for microbial upgrading to produce 2-pyrone-4,6-dicarboxylic acid (PDC). The results showed that lignin in manure fibers represents 30% of the biomass (dry weight basis), with a ∼26% abundance of β-ether-linked aromatics and ∼13% p-coumarate moieties, indicating that the amount of lignin in the postanaerobic biomass is comparable to a moderately pretreated plant biomass. The alkaline treatment released 5.6 g aromatics/kg fibers, while reductive catalytic fractionation produced 14.0 g aromatics/kg fibers. A bioreactor operated in fed-batch mode produced a yield of ∼1 mol of PDC/mol measured aromatics at a rate of 0.2 g PDC/L·h and a titer of 2.6 g PDC/L. This study demonstrates how postanaerobic digestion manure fibers could be used in a circular bioeconomy by harnessing their lignocellulosic content to extract aromatic compounds and use them for obtaining valuable chemicals via microbial upgrading.

Riascos, Brayan D. [University of Wisconsin-Madiso

Magnetic brightening and nanoscale imaging of spin-polarized helical edge modes in ZrTe 5

Efficient charge transport remains a fundamental challenge for nanoelectronic devices, as their performance is constrained by high dissipation and the impedance mismatch between high-frequency signal sources and nanoscale circuit interfaces. Although topologically protected helical edge modes offer a dissipationless and backscattering-resilient alternative, achieving nanoscale control over these modes requires direct visualization of their spatial electrodynamics, especially under high-frequency operation. Here, by utilizing cryogenic magneto-infrared scattering-type scanning near-field optical microscopy (cm-IR-sSNOM), we image spin-polarized helical edge channels in ZrTe 5 at the nanoscale, revealing magnetic-field-induced brightening as a high-frequency electrodynamic signature of robust topological edge modes. Operating at 1.8 K and under a magnetic field of up to 5 T, we observe the emergence of edge-state polarizability at infrared frequencies that is notably resilient to the magnetic gaps that typically quench d.c. and microwave edge transport. Our results reveal a topological ‘two-lane’ spatial reorganization in which an external magnetic field induces a spin-population imbalance between counterpropagating edge modes. Favoured helical branches are confined against physical boundaries to activate a net infrared near-field contrast. This electrodynamic response scales linearly with the number of atomic layers, which confirms that individual layers in ZrTe 5 preserve their discrete quantum spin Hall identities. These findings may be useful for developing topological spintronic devices, as the magnetic infrared tunability of helical edge channels provides a pathway for low-loss nanoscale interconnects and high-speed information processing.

36 MATERIALS SCIENCE

Resonant scattering at the center of the galaxy cluster PKS 0745-191 with XRISM

We report evidence of the resonant scattering effect at the center of the galaxy cluster PKS 0745-191 with XRISM. We analyzed XRISM/Resolve commissioning-phase observations of the distant cluster PKS 0745-191 ($z = 0.103$) with a $54$ ks exposure. The gain drift was corrected using the onboard modulated X-ray source (MXS), and spectra were extracted from all the pixels that were well illuminated by MXS, the core region (four central pixels, $\sim$100 kpc), and the surrounding region. A single-temperature collisional ionization equilibrium (CIE) model fits the full field-of-view spectrum with $kT \approx 6$ keV and a turbulent velocity of ${\approx}120$ km s$^{-1}$. From the core ($r < 50$ kpc) spectrum, we detected a ${\approx}22\%$ suppression of the Fe xxv He$\alpha$ resonance (w) line relative to the CIE prediction. We performed a Monte Carlo simulation to calculate the resonant scattering (RS) effect using radial profiles from Chandra data. The RS-inferred turbulence agrees with that by Resolve line-broadening, demonstrating that RS provides an independent and consistent constraint on ICM turbulence. These results highlight XRISM/Resolve’s potential for turbulence studies in galaxy clusters.

Astronomy and AstroPhysics

The DESI Single Fiber Lens Search. I. Four Thousand Spectroscopically Selected Galaxy–Galaxy Gravitational Lens Candidates

We present 4110 strong gravitational lens candidates, 3887 of which are new discoveries, selected from a sample of 5,837,154 luminous red galaxies (LRGs) observed with the Dark Energy Spectroscopic Instrument (DESI). Candidates are identified via the presence of background ionized oxygen [O II ] nebular emission lines in the foreground LRG spectra, which may originate from the lensing of higher-redshift star-forming galaxies. Using the measured foreground redshift, background redshift, and integrated flux of the background [O II ] doublet, we integrate over impact parameters to compute the probability that each candidate is a lens. We expect 53% of candidates to be true lenses with Einstein radii ranging from 0$^{''}_.$1–4", which can be confirmed with high-resolution imaging. Confirmed strong lenses from this sample will form a valuable cosmological data set, as strong gravitational lensing is the only method to directly measure dark matter halo substructure at cosmological distances. We independently recover the host of the multiply imaged gravitationally lensed type Ia supernova iPTF16geu. Monitoring these lenses for future multiply lensed transients will enable (a) H 0 measurements via time-delay cosmography and (b) substructure measurements via flux ratios.

Karp, Juliana S. M. [Univ. of Washington, Seattle,

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI