Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Joint Management and Optimization of Residential Natural Gas and Electricity Distribution Networks Coupled via Fuel Cells

The interesting properties of natural gas as well as the growing electric power demand worldwide have led to increasing attention to natural-gas-based distributed generation applications in electric distribution systems. This paper goes over the interdependency between a residential natural gas network and an electric distribution network that are coupled via fuel cells. The modeling of the gas network is introduced first, and then the algorithm for gas flow study is presented. The optimal placement and sizing of fuel cell based distributed generation systems are formulated to minimize the losses in both the gas and electric distribution networks, subject to their model constraints. In addition to this, in order to capture the probabilistic nature of the optimization problem under study, the K-means clustering algorithm is applied to the gas and electricity demands to determine hourly load states and their corresponding probabilities. Furthermore, simulation studies are carried out on an integrated system consisting of the IEEE 69-bus distribution feeder and a radial 27-node natural gas network to verify the developed optimization model and the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ParFlow Sand Tank: A tool for groundwater exploration

The ParFlow Sand Tank model is an open source application designed to allow users to interactively simulate and visualize groundwater movement through the subsurface. The app is designed for both research and education; teaching hydrogeology concepts and making it easy explore and run sophisticated groundwater simulations. Our goal is to support increased accessibility and usability of research grade hydrology tools for research and teaching. The Sand Tank application simulates groundwater and surface water fluxes as well as contaminant transport in real time using the integrated physical hydrology model ParFlow (Kollet & Maxwell, 2006; Maxwell & Miller, 2005; Osei-Kuffuor et al., 2014) and the particle tracking code EcoSlim (Maxwell et al., 2019). ParFlow is a numerical hydrology model that simulates spatially distributed groundwater and surface water flow. It is a well established research tool with more than 90 publications documenting its development use to advance our understanding of groundwater dynamics and groundwater surface water interactions from the hillslope to the continental scale e.g. (Condon et al., 2020; Condon & Maxwell, 2019; Maxwell & Condon, 2016). It is designed for efficient parallel computation and has been run on many platforms spanning from laptops to supercomputers. However, one of the challenges of ParFlow is that it requires significant training and hydrologic expertise to develop simulations. The Sand Tank application makes this model accessible to anyone for education and exploration. Our application uses ParFlow for its simulation backend and ParaView for the data loading and processing. The communication infrastructure relies on the ParaViewWeb framework. We use model templates deployed in Docker images to setup the Sand Tank framework. Users can build the application locally or interact with it through our web deployment. When interacting with a template users can interactively change model parameters like subsurface processes or pump/inject water into the subsurface and watch the system respond to their changes in real time as the simulation runs. Additionally, our template setup will allow more advanced users to build custom templates of increasing complexity for both research and educational purposes.

54 ENVIRONMENTAL SCIENCES↗

Impact of Open Communication Networks on Load Frequency Control with Plug-in Electric Vehicles by Cyber-Physical Dynamic Co-Simulation: Preprint

With the increasing electrification of the transportation sector, vehicle to grid (V2G) control technologies are promising to improving system frequency stability. However, these control technologies might require non-traditional communication supports. This paper investigates the impacts of electric vehicles (EVs) V2G on power system frequency regulation considering communication variations through transmission-distribution-communication (TDC) dynamic simulation. The simulation model is built based on our previously developed open-source transmission-and-distribution (T&D) dynamic co-simulation framework. Here, we add the communication variation functions (i.e. delay and packet loss) to complete the TDC simulation framework. In the case studies, practical communication variation scenarios are considered when the system experiencing an N-1 generation trip contingency. The considered scenarios include communication delay and packet loss using both homogeneous and heterogeneous assumptions. The delay and packet loss rate are the same in all communication channels in the homogeneous case but varies in the heterogeneous case. The results show the communication delay has an obvious impact on the frequency recovery compared to the communication packet drop. The impacts of the standard deviations of communication delay time and packet drop rate are not significant. The outcomes of this work can help improve the EV frequency regulation services and provide robust and effect supports to the grid.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Evidence of Completion of Milestone 4: Simulation Testbed Validated with Experimental Data

Milestone 4 is given in the SOPO as being due in quarter 5 (ending 9/11/2020) and is described thus: Milestone 4: Enhanced Simulation Testbed Validated with Experimental Data (UM, Mathieu). Simulation testbed validated with data obtained from experimental testbed, specifically, nonlinear load behaviors and communication network issues observed in the experimental testbed will be modeled in the simulation testbed. The simulation testbed should accurately capture TCL real and reactive power consumption (including during extreme events associated with nonlinear behaviors and communication network failures) to within 5% RMSE error with respect to data obtained from the experimental testbed. The Tasks comprising the work to achieve Milestone 4 are outlined here.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilization of Additive Manufacturing for the Rapid Prototyping of C-Band Radiofrequency Loads

Additive manufacturing is a versatile technique that shows promise in providing quick and dynamic manufacturing for complex engineering problems. Research has been ongoing into the use of additive manufacturing for potential applications in radiofrequency (RF) component technologies. Here, we present a method for developing an effective prototype load produced from 316L stainless steel on a direct metal laser sintering machine. The model was tested using simulation software to verify the validity of the design. The load structure was manufactured by an online digital manufacturing company, showing the viability of using easily accessible tools to manufacture RF structures. The produced load was able to produce an S11 value of −22.8 dB at a C-band frequency of 5.712 GHz while under a vacuum. In a high-power test, the load was able to terminate a peak power of 8.1 MW. The discussion includes future applications of the present method and how it will help to improve the implementation of future accelerator concepts.

36 MATERIALS SCIENCE↗

Wind-induced torsion of parabolic trough collectors in operation

Parabolic trough collector (PTC) systems, a type of concentrating solar power (CSP), use parabolic mirrors to reflect the sun's rays toward an absorber tube to heat the fluid inside. PTCs track the sun throughout the day and are sensitive to angular misalignment, which reduces optical performance. Torsion of the PTC, exacerbated by wind loading, contributes to angular misalignment, which has been quantified by previous studies using numerical simulations and experimental tests. However, angular misalignment due to torsion and wind loading has not yet been studied in an operational plant, which can experience more extreme and variable conditions. This study characterizes the angular misalignment due to torsion at three rows of the Nevada Solar One CSP plant and investigates the influence of wind loading. These findings reveal substantial torsion along the PTC support structure that depends on wind conditions and orientation. Strong winds perpendicular to the PTCs increase the median angular displacement of the outermost row by up to 18 mrad and increase the standard deviation by up to 8 mrad when compared to weak wind conditions. These findings can inform enhanced PTC design, controls and modeling that will improve the performance, reliability and bankability of future CSP plants.

14 SOLAR ENERGY↗

FY22 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY22. As an extension of the effort from FY21, this year’s work focuses primarily on the two-phase modeling of the NSTF using RELAP5-3D, particularly with the inclusion of the cavity model. The results from simulations were used to compare against experimental data for benchmarking purposes of the RELAP5 deck. Additionally, RELAP5 was used as a predictive tool to guide planned test operations and identify expected system behaviors. In the first part of this report, details are provided of the cavity omitted model where heat flux is applied directly as a boundary condition to the risers. The general trend predicted by the RELAP5 model matches that from the experimental data when a single-phase natural circulation flow is first established, followed by an oscillatory two-phase period and finally a stable two-phase flow. However, the onset of oscillations is predicted early by the model due to the smaller thermal mixing region in the tank. However, by expanding the simulated thermal mixing region in the tank, the onset of oscillations predicted by the model is able to match that from the experiment. These oscillations where studied in depth and are deduced to be flashing-induced instability. The model was then modified to simulate an accident scenario case where a representative heat load based on the full-scale Framatome’s 625 MW t SC-HTGR was applied directly to the riser channels. The simulated initial and boundary conditions were identical to those performed experimentally, facilitating direct comparisons between the predicted and experimental results. It was determined that the results showed some discrepancies remain, likely due to the overprediction of vapor generation rate by the computer model. In the second part of this report, the cavity model is re-introduced where it is observed that the RELAP5 prediction is now able to capture the major trends of the observed flow commonly observed during two-phase conditions. However, the onset of oscillations is once again predicted early by the model, possibly caused by the underprediction of heat loss from the heater and cavity. This is likely due to the omission of support structures in the cavity that can act as additional pathways for heat to escape to the environment. To overcome the underprediction of heat loss, part of the insulation surrounding the cavity side panels and the back of the heaters are removed to allow heat to escape directly to the environment, which then improves the RELAP5 prediction. Parametric studies are also performed to investigate the effects of heater power, tank inventory level, and tank gas space pressure on flow behaviors, also in direct comparison to conditions tested experimentally. User option-61 in the RELAP5-3D input deck, which changes the heat transfer coefficient correlations used for calculating the vapor generation, is also investigated where it is found that by enabling the option, the overall duration of oscillations is increased and matches that from the experiment better. The RELAP5 model is further benchmarked with a header inlet- throttling case where it is observed that the prediction from the model fails to capture some major features observed in the experiment. By using a modified loss coefficient curve for the valve, the accuracy of the prediction is improved where most of the major features observed in the experiment are predicted by the model. Lastly, the model is benchmarked with an inventory depletion scenario where it is observed that despite the modeling limitation of RELAP5, the prediction shows good agreement with the experimental data where major trends and features are captured by the model. Future work will see continued development of the current RELAP5-3D input deck of the NSTF to both improve the accuracy of the model’s predictive capability and continuing serving the experimental program. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evidence of Completion of Milestone 4: Simulation Testbed Validated with Experimental Data

Milestone 4 is given in the SOPO as being due in quarter 5 (ending 9/11/2020) and is described thus: Milestone 4: Enhanced Simulation Testbed Validated with Experimental Data (UM, Mathieu) Simulation testbed validated with data obtained from experimental testbed, specifically, nonlinear load behaviors and communication network issues observed in the experimental testbed will be modeled in the simulation testbed. The simulation testbed should accurately capture TCL real and reactive power consumption (including during extreme events associated with nonlinear behaviors and communication network failures) to within 5% RMSE error with respect to data obtained from the experimental testbed.

99 GENERAL AND MISCELLANEOUS↗

A Two-Level Model Predictive Control-Based Approach for Building Energy Management including Photovoltaics, Energy Storage, Solar Forecasting and Building Loads

This paper uses a two-level model predictive control-based approach for the coordinated control and energy management of an integrated system that includes photovoltaic (PV) generation, energy storage, and building loads. Novel features of the proposed local controller include (1) the ability to simultaneously manage building loads and energy storage to achieve different operational objectives such as energy efficiency, economic cost efficiency, demand response and grid optimization through the design of specific power trajectory tracking performance functionals, (2) an energy trim function that minimizes the impact of solar forecasting errors on system performance, and (3) the design of a state of charge controller that uses day-ahead forecast of solar power and building loads to intialize energy storage at the start of each day. The local controller is tested in simulation using an exemplary system with PV generation, energy storage and dispatchable building loads. Two sample days with different PV forecasts and multiple case scenarios are considered, and the performance of the algorithm in managing the real and reactive net building load trajectories and the ramp rate of PV injections into the utility network are evaluated. The simulations are based on actual forecasted and measured PV data, and the results show that the local controller meets the tracking requirements for real and reactive power within the operating constraints of the building.

14 SOLAR ENERGY↗

Validation of high-fidelity ion cyclotron range of frequencies antenna coupling simulations in full 3D geometry against experiments in the ASDEX Upgrade tokamak

We address the validation of finite elements ion cyclotron range of frequencies (ICRF) antenna coupling simulation against experiments performed in the ASDEX Upgrade tokamak. Measurements of the loading resistance in ICRF-heated, magnetically-perturbed 3D plasma discharges are compared against numerical predictions of the RAPLICASOL code. To this end, the 3D induction field and the 3D density profile are modeled by concatenating the PARVMEC, BMW and EMC3-EIRENE codes. The 3D density is input to RAPLICASOL, where full-wave simulations are performed on a finite element mesh retaining full 3D geometry in the ICRF antenna model and the plasma description. The results are further compared with RAPLICASOL simulations using a 1D density profile as measured at the outboard midplane in the same experiments. We find that simulations using a 1D density profile overestimate the change in loading resistance by a factor of ~197 -248%, while simulations using the full 3D density profile are in agreement with experiments within a factor ~16%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Weight function procedure for reduced order fracture analysis of arbitrary flaws in cylindrical pressure vessels

Fracture mechanics calculations using the finite element method can be computationally expensive, which makes them challenging to use in engineering evaluations of flaws in pressure vessels. The weight function (WF) technique is a reduced order fracture modeling method that is widely used to greatly reduce these computational costs. Its computational efficiency is essential for use in probabilistic fracture mechanics evaluations of embrittled nuclear reactor pressure vessels (RPVs), due to the large number of sampled flaws that must be evaluated. Although the WF technique is general, it is typically used only for axis-aligned flaws. Recent discoveries of off-axis flaws in operating nuclear reactors have necessitated detailed simulations of such flaws and the interactions between neighboring flaws. This paper presents a generalized WF approach applicable for analyzing arbitrary flaw geometries in thick-walled cylindrical vessels, including surface-breaking and subsurface flaws, which can either axis-aligned or off-axis, and can account for interactions with other flaws. Herein, this approach is demonstrated on representative simulations of multiple flaw geometries in a RPV subjected to transient loading conditions. In all cases, the WF technique gives good comparison with benchmark results from direct simulation with greatly reduced computational effort.

42 ENGINEERING↗

Enhancing Grid Resilience with HIVE: Decentralized V2G Coordination for Black Starts

This paper proposes the HIVE (Harmonized Integration of Vehicle Energy for Grid Support) model, a novel game-theoretic framework for decentralized coordination of electrified vehicles to enable black start and load restoration during grid outages. In the absence of a central controller, HIVE employs a cooperative game to model vehicle interactions, allowing autonomous decision-making while admitting to a Nash equilibrium for grid restoration. The framework addresses the heterogeneity of vehicles and their operational constraints, selecting a lead vehicle for grid-forming and coordinating grid-following vehicles to support prioritized loads. Applied to a hospital blackout scenario, HIVE demonstrates robust performance in forming an islanded microgrid and sustaining critical loads under varying vehicle availability, state of charge, and power constraints. Simulation results highlight the model’s effectiveness in ensuring decentralized coordination of energy allocation and prioritizing loads, offering a scalable solution for resilient grid operations.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

A Combined Computational and Mathematical Analysis of Interconnect Fatigue Potential in Photovoltaic Modules

A finite element model of a 60-cell monocrystalline silicon glass-polymer photovoltaic module was simulated with ±1.0 kPa and ±2.4 kPa loads applied to the glass to calculate the deformation under load. Cell-to-cell displacements were used to approximate interconnect strain and stress. A mathematical fatigue cycle life relation was fitted to data for the interconnect material (copper), to generate a life prediction at each interconnect location based on the local stress means, reversal extents, and amplitudes. Interconnect stress was found to be significantly asymmetric about zero despite symmetric positive and negative module loads due to laminate thickness offsets about the neutral plane and the effects of module framing. Cycle life results indicated that interconnect fatigue failure was unlikely to occur over a 30-year lifetime of conservative wind and snow load cycles since the typical cell design feature of leaving some unconstrained length between the cell edge and first solder pad increases the effective gauge length and decreases the stress levels below the material endurance limit. Follow-up analyses found that 3.6 mm and 6.4 mm were the minimum unconstrained lengths required to survive the assumed lifetime of wind and snow cycles, respectively, confirming that typical industrial module constructions with 8–15 mm unconstrained lengths should survive conservatively. Notably, large magnitude, low-cycle snow loading was consistently the limiting factor requiring a longer unconstrained interconnect length. Finally, insights and workflows from this study inform module interconnection design limits for survival against mechanical fatigue in deployment environments.

14 SOLAR ENERGY↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiple Environmental Influences on the Lightning of Cold-Based Continental Convection. Part II: Sensitivity Tests for Its Charge Structure and Land–Ocean Contrast

In Part I, an electrification scheme was described and a simulation of an observed cold-based storm from the U.S. Great Plains was validated with electrical observations. Most charge in the storm was separated by rebounding collisions of secondary ice originating from prior graupel–snow collisions. In this Part II, sensitivity tests are performed with the control simulation (Part I) and influences from environmental factors (aerosols, temperature, moisture, and shear) on lightning are elucidated. Environmental factors [e.g., convective available potential energy (CAPE)] controlling updraft speed are salient. When ascent is reduced by 30% and 70%, flashes become 70% fewer and disappear, respectively; faster ascent promotes positive cloud-to-ground (+CGs) flashes. Since cloud base is too cold (1°C) for coalescence, cloud condensation nucleus aerosol concentrations do not influence the lightning appreciably. The electrical response to varying concentrations of active ice nuclei is limited by most ice particles being secondary and less sensitive—a natural “buffer.” Imposing a maritime sounding suggests that the land–sea contrast in lightning for such storms is due to the vertical structure of environmental temperature and humidity. Weak CAPE, and both entrainment and condensate weight from a low cloud base, suppress ascent and charging. Maritime thermodynamic conditions reduce simulated flash rates by two orders of magnitude. Reducing aerosol loadings from continental to maritime only slightly reinforces this suppression. Last, a conceptual model is provided for how any simulated storm is either normal because graupel/hail is mostly positively charged or else is inverted/anomalous because graupel/hail is mostly negatively charged, with environmental factors controlling the charging. Impacts from microphysical processes, including three processes of secondary ice production, on lightning are analyzed.

54 ENVIRONMENTAL SCIENCES↗

A digital twin solution for floating offshore wind turbines validated using a full-scale prototype

Abstract. In this work, we implement, verify, and validate a physics-based digital twin solution applied to a floating offshore wind turbine. The digital twin is validated using measurement data from the full-scale TetraSpar prototype. We focus on the estimation of the aerodynamic loads, wind speed, and section loads along the tower, with the aim of estimating the fatigue lifetime of the tower. Our digital twin solution integrates (1) a Kalman filter to estimate the structural states based on a linear model of the structure and measurements from the turbine, (2) an aerodynamic estimator, and (3) a physics-based virtual sensing procedure to obtain the loads along the tower. The digital twin relies on a set of measurements that are expected to be available on any existing wind turbine (power, pitch, rotor speed, and tower acceleration) and motion sensors that are likely to be standard measurements for a floating platform (inclinometers and GPS sensors). We explore two different pathways to obtain physics-based models: a suite of dedicated Python tools implemented as part of this work and the OpenFAST linearization feature. In our final version of the digital twin, we use components from both approaches. We perform different numerical experiments to verify the individual models of the digital twin. In this simulation realm, we obtain estimated damage equivalent loads of the tower fore–aft bending moment with an accuracy of approximately 5 % to 10 %. When comparing the digital twin estimations with the measurements from the TetraSpar prototype, the errors increased to 10 %–15 % on average. Overall, the accuracy of the results is promising and demonstrates the possibility of using digital twin solutions to estimate fatigue loads on floating offshore wind turbines. A natural continuation of this work would be to implement the monitoring and diagnostics aspect of the digital twin to inform operation and maintenance decisions. The digital twin solution is provided with examples as part of an open-source repository.

17 WIND ENERGY↗

Flexible Boundary Design for a Chattanooga Microgrid Powered by Landfill Solar Photovoltaic and Battery Storage

Landfill based microgrids powered by renewable energy aid reliability and resiliency while promoting environmental and energy justice. This paper aims to design a flexible boundary algorithm for a proposed Chattanooga landfill microgrid with the ability to shrink or expand its boundaries based on the available power from the solar PV and battery storage. This helps to improve resiliency unlike the conventional fixed boundary microgrids. The flexible boundary algorithm determines the combination and switching status of the intellirupter ® which changes the microgrid boundaries to achieve power balance by dropping or energizing specific load sections. Finally, the microgrid with flexible boundary was simulated in MATLAB/Simulink and performed satisfactorily when tested under various scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗