At least 469 records · Page 26

Backsheets: Correlation of Long-Term Field Reliability with Accelerated Laboratory Testing

Our objective is to develop for backsheets a predictive tests and a model based on point-in-time data from analytical techniques and datastreams that are applicable to both outdoor and indoor PV module backsheet studies and are supplemented with meteorology data, climatic and brand/model, and other accessible information. The predictive tests and models will specify indoor and outdoor exposure and evaluation data acquisition criteria, variable selection, and temporal duration and variation so as to be able to predict backsheet performance in various climatic zones. This backsheet performance prediction is based on defined backsheet failures in the field, and is quantified by tracking backsheet degradation in the field so as to determine degradation rates.

14 SOLAR ENERGY↗

FY2023 Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton ® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY2025 Status Report: Model 9975 O Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aged at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aged at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months while fixture #18 failed after 9 months at 350 °F. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F. There has been one GLT O-ring fixture which failed after 13.4 years of aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 16.9 years and remain in test. There are two GLT O-ring fixtures at 270 °F; one fixture has failed after 12.9 years while the other fixture remains in test after 12.5 years. All GLT-S O-ring fixtures aged at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 14.9 years, while one GLT-S O-ring fixture failed after 12.4 years at 200 °F. The leak testing data to date suggest the GLT and GLT-S O-rings aging in the K-Area Complex (KAC) storage at temperatures of 158 °F might maintain a leak-tight seal for up to 59 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 24 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flight calibration source development

An important element in monitoring the sensitivity of flight instrumentation throughout a flight is a reliable reference. Tungsten filament quartz halogen and deuterium UV sources were tested for this purpose. All three types were obtained from available commercial supplies and were tested against various mission requirements, particularly long term stability characteristics. Stability tests were made before and after thermal vacuum and vibration tests.

Glicker, S.↗

Vegetable Production Systems Component Tests

As long-term spaceflight missions become ever more imminent, astronaut nutrition and diet require further investigation and development. Dehydrated or stabilized food sources are currently used for spaceflight, but growing fresh produce aboard spacecraft can potentially supplement the astronauts’ diets. Further, having astronauts work with plants while in space can provide psychological benefits by serving as a tangible passage of time and representing a living component aboard an otherwise mechanical environment. As spaceflight duration will lengthen as missions head back to the Moon and to Mars, having the ability and knowledge to grow fresh produce will become even more vital. The following experiments were conducted in the late summer and fall of 2018. The purpose of these studies were to examine potential off-gas from a system component that could potentially inhibit plant germination, optimizing lighting methods and protocol for mizuna production, determining a fertilizer method that best promotes healthy mizuna yields, and troubleshooting tomato production for the next generation of the Vegetable Production System.

international space station↗

Radiopure ZnMoO{sub 4} scintillating bolometers for the LUMINEU double-beta experiment

The results of R&D of radiopure zinc molybdate (ZnMoO{sub 4}) based scintillating bolometers for the LUMINEU (Luminescent Underground Molybdenum Investigation for NEUtrino mass and nature) double-beta decay experiment are presented. A dedicated two-stage molybdenum purification technique (sublimation in vacuum and recrystallization from aqueous solutions) and an advanced directional solidification method (the low-thermal-gradient Czochralski technique) were utilized to produce high optical quality large mass (∼1 kg) ZnMoO{sub 4} crystal boules and first {sup 100}Mo (99.5%) enriched Zn{sup 100}MoO{sub 4} crystal scintillator (mass of ∼0.2 kg). Scintillating bolometers based on ZnMoO{sub 4} (≈ 0.33 kg) and Zn{sup 100}MoO{sub 4} (≈ 0.06 kg) scintillation elements and high purity Ge wafers were tested in the EDELWEISS set-up at the Modane Underground Laboratory (France). Long term low temperature tests demonstrate excellent detectors’ performance and effectiveness of the purification and solidification procedures for the achievement of high radiopurity of the material, in particular with a bulk activity of {sup 228}Th and {sup 226}Ra below 4 µBq/kg. The adopted protocol was used to produce for the first time a large volume Zn{sup 100}MoO{sub 4} crystal scintillator (mass of ∼1.4 kg, {sup 100}Mo enrichment is 99.5%) to search for neutrinoless double-beta decay of {sup 100}Mo in the framework of the LUMINEU project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Creep, Fatigue, and Creep-Fatigue Testing of Alloy 709 Base Metal at ORNL (FY 2021)

The testing activities and research in support of ASME Code qualification of Alloy 709, an advanced austenitic steel, are being carried out at Oak Ridge National Laboratory (ORNL), Argonne National Laboratory, and Idaho National Laboratory. ORNL has been tasked to carry out a subset of the Code Case testing for creep rupture, fatigue and creep-fatigue. The focus of the FY 2021 Code Case testing on Alloy 709 base metal at ORNL includes (1) continuing the long-term creep rupture testing on ESR1100 and AOD1100; (2) adding ESR1150-AH to the creep Code Case testing matrix; and (3) continuing fatigue and creep-fatigue Code Case testing on ESR1150- AH. This report summarizes the status and the preliminary test results of FY 2021 planned Code Case testing at ORNL.

36 MATERIALS SCIENCE↗

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A dual membrane-adsorption evaporator for solar-powered lithium extraction from complex brines

A reliable supply of lithium is required to meet the increased demand for batteries over the coming decades. In this work, we demonstrated the potential to effectively extract lithium from brines by coupling solar-powered evaporation, adsorption, and membrane technologies together. We first synthesized a three-dimensional adsorptive evaporator by coating a lithium manganese oxide material onto a cotton stick using an easily scalable, one-step method. An osmotic membrane was then installed at the root of the evaporator to enhance the lithium to magnesium selectivity, prevent scaling caused by divalent cations, and thus further increase the water evaporation flux. The operation of the dual membrane-adsorption evaporator is entirely driven by osmosis and capillary force, demanding no extra energy input. The integration of the osmotic membrane was found to increase the lithium to magnesium selectivity over 10-fold to higher than 40. The dual process also produced high lithium to calcium selectivity and proved to sustain long-term stability by self-managing its internal osmotic pressure. Last, a test was done in three simulated brine solutions with varied brine chemistry and the evaporation rate stayed high and consistent throughout the long-term test. This illustrates that this technology can be used in varied brine solutions throughout the world providing efficient lithium capture and separation from competing divalent cations.

Eskafi, Aydin F. [University of California, Berkel↗

Remote Monitoring of the Structural Health of Hydrokinetic Composite Turbine Blades (Final Report)

A health monitoring approach is investigated for hydrokinetic turbine blade applications. In-service monitoring is critical due to the difficult environment for blade inspection and the cost of inspection downtime. Composite blade designs have advantages that include long life in marine environments and great control over mechanical properties. Experimental strain characteristics are determined for static loads and free-vibration loads. These experiments are designed to simulate the dynamic characteristics of hydrokinetic turbine blades. Carbon/epoxy symmetric composite laminates are manufactured using an autoclave process. Four-layer composite beams, eight-layer composite beams, and two-dimensional eight-layer composite blades are instrumented for strain. Experimental results for strain measurements from electrical resistance gages are validated with theoretical characteristics obtained from in-house finite-element analysis for all sample cases. These preliminary tests on the composite samples show good correlation between experimental and finite-element strain results. A health monitoring system is proposed in which damage to a composite structure, e.g. delamination and fiber breakage, causes changes in the strain signature behavior. The system is based on embedded strain sensors and embedded motes in which strain information is demodulated for wireless transmission. In-service monitoring is critical due to the difficult environment for blade inspection and the cost of inspection downtime. Composite blade designs provide a medium for embedding sensors into the blades for in-situ health monitoring. The major challenge with in-situ health monitoring is transmission of sensor signals from the remote rotating reference frame of the blade to the system monitoring station. In the presented work, a novel system for relaying in-situ blade health measurements in hydrokinetic systems is described and demonstrated. An ultrasonic communication system is used to transmit sensor data underwater from the rotating frame of the blade to a fixed relay station. Data are then broadcast via radio waves to a remote monitoring station. Results indicate that the assembled system can transmit simulated sensor data with an accuracy of ±5% at a maximum sampling rate of 500 samples/sec. A power investigation of the transmitter within the blade shows that continuous max-sampling operation is only possible for short durations (~days), and is limited due to the capacity of the battery power source. However, intermittent sampling, with long periods between samples, allows for the system to last for very long durations (~years). Finally, because the data transmission system can operate at a high sampling rate for short durations or at a lower sampling rate/higher duty cycle for long durations, it is well-suited for short-term prototype and environmental testing, as well as long-term commercially-deployed hydrokinetic machines.

13 HYDRO ENERGY↗

Accelerated Leach Testing of GLASS: ALTGLASS Version 3.0

The Accelerated Leach Testing of GLASS (ALTGLASS) database is a collection of data from short- and long-term product consistency tests (PCT, ASTM C1285 A and B) on high level waste (HLW) as well as low activity waste (LAW) glasses. The database provides both U.S. and international researchers with an archive of experimental data for the purpose of studying, modeling, or validating existing models of nuclear waste glass corrosion. The ALTGLASS database is maintained and updated by researchers at the Savannah River National Laboratory (SRNL). This newest version, ALTGLASS Version 3.0, has been updated with an additional 503 rows of data representing PCT results from corrosion experiments conducted in the United States by the Savannah River National Laboratory, Pacific Northwest National Laboratory, Argonne National Laboratory, and the Vitreous State Laboratory (SRNL, PNNL, ANL, VSL, respectively) as well as the National Nuclear Laboratory (NNL) in the United Kingdom.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accelerated Leach Testing of GLASS (ALTGLASS Version 4.0)

The Accelerated Leach Testing of GLASS (ALTGLASS) database is a collection of data from short- and long-term product consistency tests (PCT, ASTM C1285 A and B) on high level waste (HLW) as well as low activity waste (LAW) glasses. The database provides both U.S. and international researchers with an archive of experimental data for the purpose of studying, modeling, or validating existing models of nuclear waste glass corrosion. The ALTGLASS database is maintained and updated by researchers at the Savannah River National Laboratory (SRNL).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lessons Learned from the Aquarius Radiometer Engineering Model

The Aquarius instrument is a combination microwave radiometer and scatterometer operating in the L-band for the measurement of sea surface salinity (SSS) over the open-ocean. "The Aquarius science goals are to observe and model the processes that relate salinity variations to climatic changes in the global cycling of water and to understand how these variations influence the general ocean circulation. By measuring salinity globally and synoptically every month for 3 years, Aquarius will provide an unprecedented new view of the ocean's role in climate." (http://aquarius.asfc.nasa.gov on Jan. 4, 2007). To launch in 2009, Aquarius will provide 8-day global coverage and monthly-averaged salinity maps at approx.120-km spatial resolution. Because the microwave emissivity of the ocean surface is weakly dependent upon salinity, the Aquarius radiometer remain sufficiently stable to provide accurate salinity measurements. An engineering model (EM) of one radiometer receiver was developed and tested for functionality and performance at NASA's Goddard Space Flight Center. It was tested for long-term stability starting July 27,2006. Two discrepancies where found at the start of testing and a four-month correction process ensued. This paper covers the testing and debugging of the EM radiometer through resolution of the problems. The radiometer is required to have calibration stability of less than or equal to 0.15 K over 7 days. The radiometer is in a three-beam push-broom configuration with each beam being an independent three-state Dicke radiometer (antenna, reference load, and additive noise). Internal noise diodes and reference loads provide periodic and rapid calibration of the receiver. Front-end loss contributions must be corrected as the lossy components are outside the calibration loop. A key design feature for obtaining stability is active thermal control of the front-end lossy components and the RF receiver. The thermal stability is predicted to be about 0.1 C over an orbit and no more than 1 C over a year. The radiometric stability requirement is 0.13 K rms 1 7 days without using temperature corrections. Temperature corrections and post-launch calibration are expected to extend the stability period through the life of the mission.

Piepmeier, Jeffrey↗

Stirling Technology Development at NASA GRC

The Department of Energy, Stirling Technology Company (STC), and NASA Glenn Research Center (NASA Glenn) are developing a free-piston Stirling convertor for a high efficiency Stirling Radioisotope Generator (SRG) for NASA Space Science missions. The SRG is being developed for multimission use, including providing electric power for unmanned Mars rovers and deep space missions. NASA Glenn is conducting an in-house technology project to assist in developing the convertor for space qualification and mission implementation. Recent testing of 55-We Technology Demonstration Convertors (TDCs) built by STC includes mapping of a second pair of TDCs, single TDC testing, and TDC electromagnetic interference and electromagnetic compatibility characterization on a nonmagnetic test stand. Launch environment tests of a single TDC without its pressure vessel to better understand the convertor internal structural dynamics and of dual-opposed TDCs with several engineering mounting structures with different natural frequencies have recently been completed. A preliminary life assessment has been completed for the TDC heater head, and creep testing of the IN718 material to be used for the flight convertors is underway. Long-term magnet aging tests are continuing to characterize any potential aging in the strength or demagnetization resistance of the magnets used in the linear alternator (LA). Evaluations are now beginning on key organic materials used in the LA and piston/rod surface coatings. NASA Glenn is also conducting finite element analyses for the LA, in part to look at the demagnetization margin on the permanent magnets. The world's first known integrated test of a dynamic power system with electric propulsion was achieved at NASA Glenn when a Hall-effect thruster was successfully operated with a free-piston Stirling power source. Cleveland State University is developing a multidimensional Stirling computational fluid dynamics code to significantly improve Stirling loss predictions and assist in identifying convertor areas for further improvements. This paper will update the status and results for these efforts.

Thieme, Lanny G.↗

Stirling Technology Development at NASA GRC

The Department of Energy, Stirling Technology Company (STC), and NASA Glenn Research Center (NASA Glenn) are developing a free-piston Stirling convertor for a high-efficiency Stirling Radioisotope Generator (SRG) for NASA Space Science missions. The SRG is being developed for multimission use, including providing electric power for unmanned Mars rovers and deep space missions. NASA Glenn is conducting an in-house technology project to assist in developing the convertor for space qualification and mission implementation. Recent testing, of 55-We Technology Demonstration Convertors (TDC's) built by STC includes mapping, of a second pair of TDC's, single TDC testing, and TDC electromagnetic interference and electromagnetic compatibility characterization on a nonmagnetic test stand. Launch environment tests of a single TDC without its pressure vessel to better understand the convertor internal structural dynamics and of dual-opposed TDC's with several engineering mounting structures with different natural frequencies have recently been completed. A preliminary life assessment has been completed for the TDC heater head, and creep testing of the IN718 material to be used for the flight convertors is underway. Long-term magnet aging tests are continuing to characterize any potential aging in the strength or demagnetization resistance of the magnets used in the linear alternator (LA). Evaluations are now beginning on key organic materials used in the LA and piston/rod surface coatings. NASA Glenn is also conducting finite element analyses for the LA, in part to look at the demagnetization margin on the permanent magnets. The world's first known integrated test of a dynamic power system with electric propulsion was achieved at NASA Glenn when a Hall-effect thruster was successfully operated with a free-piston Stirling power source. Cleveland State University is developing a multidimensional Stirling computational fluid dynamics code to significantly improve Stirling loss predictions and assist in identifying convertor areas for further improvements. This paper will update the status and results for these efforts.

Thieme, Lanny G.↗

Long-Term Reliability of SiGe/Si HBTs From Accelerated Lifetime Testing

Accelerated lifetime tests were performed on double-mesa structure Si(0.7)Ge(0.3)/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175 C-275 C. The transistors (with 5x20 sq micron emitter area) have DC current gains approx. 40-50 and f(sub T) and f(sub max) of up to 22 GHz and 25 GHz, respectively. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REED has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of these devices at room temperature under 1.35 x 10(exp 4) A/sq cm current density operation is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation.

Bhattacharya, Pallab↗