Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement error model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Filter Tuning Using the Chi-Squared Statistic

This paper examines the use of the Chi-square statistic as a means of evaluating filter performance. The goal of the process is to characterize the filter performance in the metric of covariance realism. The Chi-squared statistic is the value calculated to determine the realism of a covariance based on the prediction accuracy and the covariance values at a given point in time. Once calculated, it is the distribution of this statistic that provides insight on the accuracy of the covariance. The process of tuning an Extended Kalman Filter (EKF) for Aqua and Aura support is described, including examination of the measurement errors of available observation types, and methods of dealing with potentially volatile atmospheric drag modeling. Predictive accuracy and the distribution of the Chi-squared statistic, calculated from EKF solutions, are assessed.

Filter Tuning↗

Fabrication of coronagraph masks and laboratory scale star-shade masks: characteristics, defects and performance

NASA WFIRST mission has planned to include a coronagraph instrument to find and characterize exoplanets. Masks are needed to suppress the host star light to better than 10-8 – 10-9 level contrast over a broad bandwidth to enable the coronagraph mission objectives. Such masks for high contrast coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, etc. We present the technologies employed at JPL to produce these pupil plane and image plane coronagraph masks, and lab-scale external occulter masks, highlighting accomplishments from the high contrast imaging testbed (HCIT) at JPL and from the high contrast imaging lab (HCIL) at Princeton University. Inherent systematic and random errors in fabrication and their impact on coronagraph performance are discussed with model predictions and measurements.

Casey Wilson, Robert↗

Uncertainty in Heart Rate Complexity Metrics Caused by R-Peak Perturbations

Heart rate complexity (HRC) is a proven metric for gaining insight into human stress and physiological deterioration. To calculate HRC, the detection of the exact instance of when the heart beats, the R-peak, is necessary. Electrocardiogram (ECG) signals can often be corrupted by environmental noise (e.g., from electromagnetic interference, movement artifacts), which can potentially alter the HRC measurement, producing erroneous inputs which feed into decision support models. Current literature has only investigated how HRC is affected by noise when R-peak detection errors occur (false positives and false negatives). However, the numerical methods used to calculate HRC are also sensitive to the specific location of the fiducial point of the R-peak. This raises many questions regarding how this fiducial point is altered by noise, the resulting impact on the measured HRC, and how we can account for noisy HRC measures as inputs into our decision models. This work uses Monte Carlo simulations to systematically add white and pink noise at different permutations of signal-to-noise ratios (SNRs), time segments, sampling rates, and HRC measurements to characterize the influence of noise on the HRC measure by altering the fiducial point of the R-peak. Using the generated information from these simulations provides improved decision processes for system design which address key concerns such as permutation entropy being a more precise, reliable, less biased, and more sensitive measurement for HRC than sample and approximate entropy.

Napoli, Nicholas J.↗

Anisotropy of thermal infrared exitance in sunflower canopies

Anisotropy of thermal infrared exitance above and within a relatively closed fully irrigated sunflower canopy is detailed. Azimuthal variation in thermal infrared exitance above canopies was weakly (statistically) related to solar position and was comparable to or larger than errors in satellite-based canopy estimates. Anisotropy within canopies was significantly lower and decreased with canopy closure and depth into the canopy. Measured azimuthal isotropy within canopies supports the use of this assumption in radiative transfer models. Significant differences in canopy temperature measurements were found depending upon whether the instruments were within or above the canopy. These differences could produce errors of 20-35 percent in latent energy estimates during periods of high evapotranspiration (ET) and greater errors in periods of restricted ET.

Tha Paw u, Kyaw↗

Application of Pressure-Based Wall Correction Methods to Two NASA Langley Wind Tunnels

This paper is a description and status report on the implementation and application of the WICS wall interference method to the National Transonic Facility (NTF) and the 14 x 22-ft subsonic wind tunnel at the NASA Langley Research Center. The method calculates free-air corrections to the measured parameters and aerodynamic coefficients for full span and semispan models when the tunnels are in the solid-wall configuration. From a data quality point of view, these corrections remove predictable bias errors in the measurement due to the presence of the tunnel walls. At the NTF, the method is operational in the off-line and on-line modes, with three tests already computed for wall corrections. At the 14 x 22-ft tunnel, initial implementation has been done based on a test on a full span wing. This facility is currently scheduled for an upgrade to its wall pressure measurement system. With the addition of new wall orifices and other instrumentation upgrades, a significant improvement in the wall correction accuracy is expected.

Iyer, V.↗

Global Precipitation Measurement (GPM) Ground Validation: Plans and Preparations

The Global Precipitation Measurement (GPM) program is an international partnership led by the National Aeronautics and Space Administration (NASA) and the Japan Aerospace Exploration Agency (JAXA). GPM will improve climate, weather, and hydro-meteorological forecasts through more frequent and more accurate measurement of precipitation across the globe. This paper describes the concept, the planning, and the preparations for Ground Validation within the GPM program. Ground Validation (GV) plays an important role in the program by investigating and quantitatively assessing the errors within the satellite retrievals. These quantitative estimates of retrieval errors will assist the scientific community by bounding the errors within their research products. The two fundamental requirements of the GPM Ground Validation program are: (1) error characterization of the precipitation retrievals and (2) continual improvement of the satellite retrieval algorithms. These two driving requirements determine the measurements, instrumentation, and location for ground observations. This paper outlines GV plans for estimating the systematic and random components of retrieval error and for characterizing the spatial p d temporal structure of the error and plans for algorithm improvement in which error models are developed and experimentally explored to uncover the physical causes of errors within the retrievals. This paper discusses NASA locations for GV measurements as well as anticipated locations from international GPM partners. NASA's primary locations for validation measurements are an oceanic site at Kwajalein Atoll in the Republic of the Marshall Islands and a continental site in north-central Oklahoma at the U.S. Department of Energy's Atmospheric Radiation Measurement Program site.

Schwaller, M.↗

Theoretical computation of trace gases retrieval random error from measurements of high spectral resolution infrared sounder

The purpose of this paper is to demonstrate the trace gas profiling capabilities of future passive high spectral resolution (1 cm(exp -1) or better) infrared (600 to 2700 cm(exp -1)) satellite tropospheric sounders. These sounders, such as the grating spectrometer, Atmospheric InfRared Sounders (AIRS) (Chahine et al., 1990) and the interferometer, GOES High Resolution Interferometer Sounder (GHIS), (Smith et al., 1991) can provide these unique infrared spectra which enable us to conduct this analysis. In this calculation only the total random retrieval error component is presented. The systematic error components contributed by the forward and inverse model error are not considered (subject of further studies). The total random errors, which are composed of null space error (vertical resolution component error) and measurement error (instrument noise component error), are computed by assuming one wavenumber spectral resolution with wavenumber span from 1100 cm(exp -1) to 2300 cm(exp -1) (the band 600 cm(exp -1) to 1100 cm(exp -1) is not used since there is no major absorption of our three gases here) and measurement noise of 0.25 degree at reference temperature of 260 degree K. Temperature, water vapor, ozone and mixing ratio profiles of nitrous oxide, carbon monoxide and methane are taken from 1976 US Standard Atmosphere conditions (a FASCODE model). Covariance matrices of the gases are 'subjectively' generated by assuming 50 percent standard deviation of gaussian perturbation with respect to their US Standard model profiles. Minimum information and maximum likelihood retrieval solutions are used.

Huang, Hung-Lung↗

Stochastic-Dynamical Modeling of Space Time Rainfall

The focus of this research work is the elucidation of the physical origins of the observed extreme-rainfall variability over tropical oceans. The quantitative results of this work may be used to establish links between deterministic models of the mesoscale and synoptic scale with statistical descriptions of the temporal variability of local tropical oceanic rainfall. In addition, they may be used to quantify the influence of measurement error in large-scale forcing and cloud scale observations on the accuracy of local rainfall variability inferences, important for hydrologic studies. A simple statistical-dynamical model, suitable for use in repetitive Monte Carlo experiments, is formulated as a diagnostic tool for this purpose. Stochastic processes with temporal structure and parameters estimated from observed large-scale data represent large-scale forcing.

Georgankakos, Konstantine P.↗

Model validation of SIM external metrology at the sub-nanometer level

In order to achieve micro-arcsecond astrometry, SIM must make measurements of various optical path lengths at the picometer level. In this regime of precision, nearly every simplifying assumption in optics must be reexamined as a potential source of systematic error. SIM makes extensive use of physics-based models to predict the form and level of systematic errors affecting instrument performance. Since many of the modeling areas represent new frontiers in optical modeling, the validation of these physical models is a significant challenge that SIM must meet. In the case of the external metrology truss, the model must account for the imperfections in the corner cubes as well as the distance measuring interferometers ("beam launchers"). This model is being validated using the Kite testbed, a 2-D metrology truss with picometer-level accuracy in displacement measurements. We present the model and the results of the model validation tests on the Kite testbed.

Kuan, Gary M.↗

A Systematic Approach to Sensor Selection for Aircraft Engine Health Estimation

A systematic approach for selecting an optimal suite of sensors for on-board aircraft gas turbine engine health estimation is presented. The methodology optimally chooses the engine sensor suite and the model tuning parameter vector to minimize the Kalman filter mean squared estimation error in the engine s health parameters or other unmeasured engine outputs. This technique specifically addresses the underdetermined estimation problem where there are more unknown system health parameters representing degradation than available sensor measurements. This paper presents the theoretical estimation error equations, and describes the optimization approach that is applied to select the sensors and model tuning parameters to minimize these errors. Two different model tuning parameter vector selection approaches are evaluated: the conventional approach of selecting a subset of health parameters to serve as the tuning parameters, and an alternative approach that selects tuning parameters as a linear combination of all health parameters. Results from the application of the technique to an aircraft engine simulation are presented, and compared to those from an alternative sensor selection strategy.

Simon, Donald L.↗

Turbulence modeling and experiments

The best way of verifying turbulence is to do a direct comparison between the various terms and their models. The success of this approach depends upon the availability of the data for the exact correlations (both experimental and DNS). The other approach involves numerically solving the differential equations and then comparing the results with the data. The results of such a computation will depend upon the accuracy of all the modeled terms and constants. Because of this it is sometimes difficult to find the cause of a poor performance by a model. However, such a calculation is still meaningful in other ways as it shows how a complete Reynolds stress model performs. Thirteen homogeneous flows are numerically computed using the second order closure models. We concentrate only on those models which use a linear (or quasi-linear) model for the rapid term. This, therefore, includes the Launder, Reece and Rodi (LRR) model; the isotropization of production (IP) model; and the Speziale, Sarkar, and Gatski (SSG) model. Which of the three models performs better is examined along with what are their weaknesses, if any. The other work reported deal with the experimental balances of the second moment equations for a buoyant plume. Despite the tremendous amount of activity toward the second order closure modeling of turbulence, very little experimental information is available about the budgets of the second moment equations. Part of the problem stems from our inability to measure the pressure correlations. However, if everything else appearing in these equations is known from the experiment, pressure correlations can be obtained as the closing terms. This is the closest we can come to in obtaining these terms from experiment, and despite the measurement errors which might be present in such balances, the resulting information will be extremely useful for the turbulence modelers. The purpose of this part of the work was to provide such balances of the Reynolds stress and heat flux equations for the buoyant plume.

Shabbir, Aamir↗

A Celestial Reference Frame Based on Kalman Filtering

In this study, we investigate a novel approach to the determination of celestial reference frames (CRF). Instead of a constant model for radio sources positions, we adopt a time series representation, which allows temporal variations of radio source coordinates to be taken into account. In particular, the added flexibility is beneficial for radio sources with extended structure. We compute our time series-based CRF solutions by Kalman filtering and smoothing radio source positions, which are initially obtained from single-session VLBI analysis. The temporal resolution of the estimated CRF coordinates is identical to that of the input data, i.e. usually 1-4 days. The magnitude of the coordinate variations is controlled by the amount of process noise applied in the filter, which is in turn derived from analyzing the Allan standard deviation of the corresponding radio source coordinate time series. Measures have been developed to reduce the impact of observation errors and datum effects on the noise model.

Soja, B.↗

Evaluating a Regional Climate Model Simulation of Greenland Ice Sheet Snow and Firn Density for Improved Surface Mass Balance Estimates

Modeling vertical profiles of snow and firn density near the surface of the Greenland ice sheet (GrIS) is key to estimating GrIS mass balance, and by extension, global sea level change. To understand sources of error in simulated GrIS density, we compare GrIS density profiles from a leading regional climate model with coincident in situ measurements. We identify key contributors to model density and mass balance biases, including underestimated simulated fresh snow density (which leads to underestimation of density in the top 1 m of snow by ~10%). In areas undergoing frequent melting, positive density biases (of 7% in the top 1 m, and 10% between 1 and 10 m) are likely associated with errors in representing meltwater production, retention and refreezing. The results highlight the importance of accurately capturing fresh snow density and meltwater processes in models used to estimate GrIS mass balance change.

P M Alexander↗

Forced and Moment Measurements with Pressure-Sensitive Paint

The potential of pressure-sensitive paint (PSP) to provide aerodynamic loads measurements has been a driving force behind the development of this measurement technique. To demonstrate the suitability of PSP for this purpose, it is necessary to show that PSP-derived pressures can be accurately integrated over the model surface. This cannot be done simply by demonstrating the accuracy of PSP as compared to pressure taps. PSP errors due to misregistration or temperature sensitivity may be high near model edges, where they will have a strong effect on moment measurements, but where pressure taps are rarely installed. A more suitable technique is to compare integrated PSP data over the entire model surface with balance and/or CFD results. This paper presents results from three experiments in which integrated PSP data is compared with balance and/or CFD data. This allows the usefulness of PSP for force and moment measurements, and by implication for loads measurements, to be assessed.

Bell, James H.↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗

Recent Advances to Estimation of Fixed-Interface Modal Models Using Dynamic Substructuring

In 2010, Allen & Mayes proposed to estimate the fixed-interface modes of a structure by measuring the modes of the structure bolted to a fixture and then applying constraints to the fixture using the transmission simulator method. While the method proved useful, and has indeed been used in studies since that point, a few peculiarities were noted. First, in some cases the estimated fixed-base natural frequencies were observed to converge very slowly to the true values (in simulated experiments) as the number of constraints was increased. To formulate these constraints, prior studies used only the free-interface modes of the fixture or the measured modes of the assembly. This work extends that to consider other sets of constraints, showing improved results. Furthermore, in some prior studies it has been observed that there were errors of more than 10% in the natural frequencies even when the fixture motion was hundreds of times smaller than the motion of the structure of interest (and so it had presumably been removed). This work explores this phenomenon, seeking to use the strain energy in the fixture, to the extent that it can be estimated using a test-analysis model for the fixture, as a metric to predict frequency error. The proposed methods are explored by applying them to simulated measurements from a beam and from the NASA Space Launch System coupled to the Mobile Launcher.

Allen, Mathew S.↗

Performance comparison for Barnes model 12-1000, Exotech model 100, and Ideas Inc. Biometer Mark 2

Results of tests show that all channels of all instruments, except channel 3 of the Biometer Mark 2, were stable in response to input signals were linear, and were adequately stable in response to temperature changes. The Biometer Mark 2 is labelled with an inappropriate description of the units measured and the dynamic range is a inappropriate for field measurements causing unnecessarily high fractional errors. This instrument is, therefore, quantization limited. The dynamic range and noise performance of the Model 12-1000 are appropriate for remote sensing field research. The field of view and performance of the Model 100A and the Model 12-1000 are satisfactory. The Biometer Mark 2 has not, as yet, been satisfactorily equipped with an acceptable field of view determining device. Neither the widely used aperture plate nor the 24 deg cone are acceptable.

Robinson, B.↗

Inspection error and its adverse effects - A model with implications for practitioners

Inspection error has clearly been shown to have adverse effects upon the results desired from a quality assurance sampling plan. These effects upon performance measures have been well documented from a statistical point of view. However, little work has been presented to convince the QC manager of the unfavorable cost consequences resulting from inspection error. This paper develops a very general, yet easily used, mathematical cost model. The basic format of the well-known Guthrie-Johns model is used. However, it is modified as required to assess the effects of attributes sampling errors of the first and second kind. The economic results, under different yet realistic conditions, will no doubt be of interest to QC practitioners who face similar problems daily. Sampling inspection plans are optimized to minimize economic losses due to inspection error. Unfortunately, any error at all results in some economic loss which cannot be compensated for by sampling plan design; however, improvements over plans which neglect the presence of inspection error are possible. Implications for human performance betterment programs are apparent, as are trade-offs between sampling plan modification and inspection and training improvements economics.

Collins, R. D., Jr.↗