Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear spectral function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Bisphosphonates do not Alter the Rate of Secondary Mineralization

Bisphosphonates function to reduce bone turnover, which consequently increases the mean degree of tissue mineralization at an organ level. However, it is not clear if bisphosphonates alter the length of time required for an individual bone-modeling unit (BMU) to fully mineralize. We have recently demonstrated that it takes {approx}350 days (d) for normal, untreated cortical bone to fully mineralize. The aim of this study was to determine the rate at which newly formed trabecular BMUs become fully mineralized in rabbits treated for up to 414 d with clinical doses of either risedronate (RIS) or alendronate (ALN). Thirty-six, 4-month old virgin female New Zealand white rabbits were allocated to RIS (n=12; 2.4 {mu}g/kg body weight), ALN (n=12; 2.4 {mu}g/kg body weight), or volume-matched saline controls (CON; n=12). Fluorochrome labels were administered at specific time intervals to quantify the rate and level of mineralization of trabecular bone from the femoral neck (FN) by Fourier transform infrared microspectroscopy (FTIRM). The organic (collagen) and inorganic (phosphate and carbonate) IR spectral characteristics of trabecular bone from undecalcified 4 micron thick tissue sections were quantified from fluorescently labels regions that had mineralized for 1, 8, 18, 35, 70, 105, 140, 210, 280, and 385 d (4 rabbits per time point and treatment group). All groups exhibited a rapid increase in mineralization over the first 18 days, the period of primary mineralization, with no significant differences between treatments. Mineralization continued to increase, at a slower rate up, to 385 days (secondary mineralization), and was not different among treatments. There were no significant differences between treatments for the rate of mineralization within an individual BMU; however, ALN and RIS both increased global tissue mineralization as demonstrated by areal bone mineral density from DXA. We conclude that increases in tissue mineralization that occur following a period of bisphosphonate treatment is a function of the suppressed rate of remodeling that allows for a greater number of BMUs to obtain a greater degree of mineralization.

59 BASIC BIOLOGICAL SCIENCES↗

Electronic temperatures, densities, and plasma x-ray emission of a 14.5 GHz electron-cyclotron resonance ion source

We have performed a systematic study of the bremsstrahlung emission from the electrons in the plasma of a commercial 14.5 GHz electron-cyclotron resonance ion source. The electronic spectral temperature and the product of ionic and electronic densities of the plasma are measured by analyzing the bremsstrahlung spectra recorded for several rare gases (Ar, Kr, and Xe) as a function of the injected power. Within our uncertainty, we find an average temperature of {approx_equal}48 keV above 100 W, with a weak dependency on the injected power and gas composition. Charge state distributions of extracted ion beams have been determined as well, providing a way to disentangle the ionic density from the electronic density. Moreover x-ray emission from highly charged argon ions in the plasma has been observed with a high-resolution mosaic-crystal spectrometer, demonstrating the feasibility for high-precision measurements of transition energies of highly charged ions, in particular, of the magnetic dipole (M1) transition of He-like of argon ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Realistic spectral function model for charged-current quasielastic-like neutrino and antineutrino scattering cross sections on C 12

A detailed study of charged current quasielastic neutrino and antineutrino scattering cross sections on a 12 C target with no pions in the final state is presented. The initial nucleus is described by means of a realistic spectral function S($p$,E) in which nucleon-nucleon correlations are implemented by using natural orbitals through the Jastrow method. The roles played by these correlations and by final-state interactions are analyzed and discussed. The model also includes the contribution of weak two-body currents in the two-particle two-hole sector, evaluated within a fully relativistic Fermi gas. The theoretical predictions are compared with a large set of experimental data for double-differential, single-differential, and total integrated cross sections measured by the MiniBooNE, MINER ν A , and T2K experiments. Good agreement with experimental data is found over the whole range of neutrino energies. The results are also in global good agreement with the predictions of the superscaling approach, which is based on the analysis of electron-nucleus scattering data, with only a few differences seen at specific kinematics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dynamic granularity of imaging systems

Imaging systems that include a specific source, imaging concept, geometry, and detector have unique properties such as signal-to-noise ratio, dynamic range, spatial resolution, distortions, and contrast. Some of these properties are inherently connected, particularly dynamic range and spatial resolution. It must be emphasized that spatial resolution is not a single number but must be seen in the context of dynamic range and consequently is better described by a function or distribution. We introduce the “dynamic granularity” G dyn as a standardized, objective relation between a detector’s spatial resolution (granularity) and dynamic range for complex imaging systems in a given environment rather than the widely found characterization of detectors such as cameras or films by themselves. We found that this relation can partly be explained through consideration of the signal’s photon statistics, background noise, and detector sensitivity, but a comprehensive description including some unpredictable data such as dust, damages, or an unknown spectral distribution will ultimately have to be based on measurements. Measured dynamic granularities can be objectively used to assess the limits of an imaging system’s performance including all contributing noise sources and to qualify the influence of alternative components within an imaging system. Our article explains the construction criteria to formulate a dynamic granularity and compares measured dynamic granularities for different detectors used in the X-ray backlighting scheme employed at Sandia’s Z-Backlighter facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution setup for measuring wavelength sensitivity of photoyellowing of translucent materials

Polystyrene and many other materials turn yellow when exposed to ultraviolet (UV) radiation. All photodegradation mechanisms including photoyellowing are functions of the exposure wavelength, which can be described with an action spectrum. In this work, a new high-resolution transmittance measurement setup based on lasers has been developed for measuring color changes, such as the photoyellowing of translucent materials aged with a spectrograph. The measurement setup includes 14 power-stabilized laser lines between 325 nm and 933 nm wavelengths, of which one at a time is directed on to the aged sample. The power transmitted through the sample is measured with a silicon detector utilizing an integrating sphere. The sample is mounted on a high-resolution XY translation stage. Measurement at various locations aged with different wavelengths of exposure radiation gives the transmittance data required for acquiring the action spectrum. The combination of a UV spectrograph and the new high-resolution transmittance measurement setup enables a novel method for studying the UV-induced ageing of translucent materials with a spectral resolution of 3–8 nm, limited by the adjustable spectral bandwidth range of the spectrograph. These achievements form a significant improvement over earlier methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Q-switched Ho:YAG laser assisted nanosecond time-resolved T-jump transient mid-IR absorbance spectroscopy with high sensitivity

Knowledge of dynamical structure of protein is an important clue to understand its biological function in vivo. Temperature-jump (T-jump) time-resolved transient mid-IR absorbance spectroscopy is a powerful tool in elucidating the protein dynamical structures and the folding/unfolding kinetics of proteins in solution. A home-built setup of T-jump time-resolved transient mid-IR absorbance spectroscopy with high sensitivity is developed, which is composed of a Q-switched Cr, Tm, Ho:YAG laser with an output wavelength at 2.09 μm as the T-jump heating source, and a continuous working CO laser tunable from 1580 to 1980 cm{sup −1} as the IR probe. The results demonstrate that this system has a sensitivity of 1 × 10{sup −4} ΔOD for a single wavelength detection, and 2 × 10{sup −4} ΔOD for spectral detection in amide I′ region, as well as a temporal resolution of 20 ns. Moreover, the data quality coming from the CO laser is comparable to the one using the commercial quantum cascade laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotope shifts of the 1s{sup 2}2s{sup 2}({sup 1}S{sub 0}) {yields} 1s{sup 2}2p{sup 2}({sup 1}S{sub 0}) transition in the doubly ionized carbon ion C{sup 2+}

Highly accurate quantum mechanical calculations are performed for the 1s{sup 2}2s{sup 2} ({sup 1}S{sub 0}) {yields} 1s{sup 2}2p{sup 2} ({sup 1}S{sub 0}) transition energy in the isotopomers of C{sup 2+} ion to determine the isotope shifts. Explicitly correlated Gaussian functions and a variational approach that explicitly includes the nuclear motion are employed in the calculations. The leading relativistic and quantum electrodynamics corrections to the transition energy are also calculated using the perturbation theory with the nonrelativistic wave function as the zero-order approximation. It is determined that the {sup 12}C{sup 2+} transitions energy, which is obtained from the calculations to be 182 519.031 cm{sup -1} (vs the experimental value of 182 519.88 cm{sup -1}, an excellent sub-wave-number agreement) up-shifts by 1.755 cm{sup -1} for {sup 13}C{sup 2+} and by additional 1.498 cm{sup -1} for {sup 14}C{sup 2+}. Those shifts are sufficiently large to be measured experimentally.

74 ATOMIC AND MOLECULAR PHYSICS↗

Injection Locking Techniques for Spectrum Analysis

Wideband spectrum analysis supports future communication systems that reconfigure and adapt to the capacity of the spectral environment. While test equipment manufacturers offer wideband spectrum analyzers with excellent sensitivity and resolution, these spectrum analyzers typically cannot offer acceptable size, weight, and power (SWAP). CMOS integrated circuits offer the potential to fully integrate spectrum analysis capability with analog front-end circuitry and digital signal processing on a single chip. Unfortunately, CMOS lacks high-Q passives and wideband resonator tunability that is necessary for heterodyne implementations of spectrum analyzers. As an alternative to the heterodyne receiver architectures, two nonlinear methods for performing wideband, low-power spectrum analysis are presented. The first method involves injecting the spectrum of interest into an array of injection-locked oscillators. The second method employs the closed loop dynamics of both injection locking and phase locking to independently estimate the injected frequency and power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid state NMR method development and studies of biological and biomimetic nanocomposites

This thesis describes application and development of advanced solid-state nuclear magnetic resonance techniques for complex materials, in particular organic-inorganic nanocomposites and thermoelectric tellurides. The apatite-collagen interface, essential for understanding the biomineralization process in bone and engineering the interface for controlled bio-mimetic synthesis and optimized mechanical properties, is buried within the nanocomposite of bone. We used multinuclear solid-state NMR to study the composition and structure of the interface. Citrate has been identified as the main organic molecule strongly bound to the apatite surface with a density of 1/(2 nm) 2 , covering 1/6 of the total surface area in bovine bone. Citrate provides more carboxylate groups, one of the key functional groups found to affect apatite nucleation and growth, than all the non-collagenous proteins all together in bone; thus we propose that citrate stabilizes apatite crystals at a very small thickness of ~3 nm (4 unit cells) to increase bone fracture tolerance. The hypothesis has been confirmed in vitro by adding citrate in the bio-mimetic synthesis of polymerhydroxyapatite nanocomposites. The results have shown that the size of hydroxyapatite nanocrystals decreases as increasing citrate concentration. With citrate concentrations comparable to that in body fluids, similar-sized nanocrystals as in bone have been produced. Besides the dimensions of the apatite crystals, the composition of bone also affects its biofunctional and macroscopic mechanical properties; therefore, our team also extended its effort to enhance the inorganic portion in our bio-mimetic synthesis from originally 15 wt% to current 50 wt% compared to 65 wt% in bovine bone, by using Lysine-Leucine hydroxyapatite nucleating diblock co-polypeptide, which forms a gel at very low concentration. In this thesis, various advanced solid state NMR techniques have been employed to characterize nanocomposites. Meanwhile, we have developed new methods to achieve broadband high resolution NMR and improve the accuracy of inter-nuclear distance measurements involving quadrupolar spins. Broadband high resolution NMR of spin-1/2 nuclei has been accomplished by the adaptation of the magic angle turning (MAT) method to fast magic angle spinning, termed fast MAT, by solving technical problems such as off resonance effects. Fast MAT separates chemical shift anisotropy and isotropic chemical shifts over a spectral range of ~1.8 γB 1 without significant distortions. Fast MAT 125 Te NMR has been applied to study technologically important telluride materials with spectra spreading up to 190 kHz. The signal-to-noise ratio of the spectra is significantly improved by using echo-matched Gaussian filtering in offline data processing. The accuracy of the measured distances between spin-1/2 and quadrupolar nuclei with methods such as SPIDER and REAPDOR has been improved by compensating for the fast longitudinal quadrupolar relaxation on the sub-millisecond with a modified S 0 pulse sequence. Also, the T1Q effect on the spin coherence and its spinning speed dependency has been explored and documented with analytical and numerical simulations as well as experimental measurements.

36 MATERIALS SCIENCE↗

Application of an EMCCD Camera for Calibration of Hard X-Ray Telescopes

Recent technological innovations now make it feasible to construct hard x-ray telescopes for space-based astronomical missions. Focusing optics are capable of improving the sensitivity in the energy range above 10 keV by orders of magnitude compared to previously used instruments. The last decade has seen focusing optics developed for balloon experiments and they will soon be implemented in approved space missions such as the Nuclear Spectroscopic Telescope Array (NuSTAR) and ASTRO-H. The full characterization of x-ray optics for astrophysical and solar imaging missions, including measurement of the point spread function (PSF) as well as scattering and reflectivity properties of substrate coatings, requires a very high spatial resolution, high sensitivity, photon counting and energy discriminating, large area detector. Novel back-thinned Electron Multiplying Charge-Coupled Devices (EMCCDs) are highly suitable detectors for ground-based calibrations. Their chip can be optically coupled to a microcolumnar CsI(Tl) scintillator via a fiberoptic taper. Not only does this device exhibit low noise and high spatial resolution inherent to CCDs, but the EMCCD is also able to handle high frame rates due to its controllable internal gain. Additionally, thick CsI(Tl) yields high detection efficiency for x-rays. This type of detector has already proven to be a unique device very suitable for calibrations in astrophysics: such a camera was used to support the characterization of the performance for all NuSTAR optics. Further optimization will enable similar cameras to be improved and used to calibrate x-ray telescopes for future space missions. In this paper, we discuss the advantages of using an EMCCD to calibrate hard x-ray optics. We will illustrate the promising features of this detector solution using examples of data obtained during the ground calibration of the NuSTAR telescopes performed at Columbia University during 2010/2011. Finally, we give an outlook on ongoing development and optimizations, such as the use of single photon counting mode to enhance spectral resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Uncertainty analysis technique for OMEGA Dante measurements

The Dante is an 18 channel x-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g., hohlraums, etc.) at x-ray energies between 50 eV and 10 keV. It is a main diagnostic installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the x-ray diodes, filters and mirrors, and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotope shift in the electron affinity of lithium

Very accurate electron affinity (EA) calculations of {sup 6}Li and {sup 7}Li (and {sup {infinity}L}i) have been performed using explicitly correlated Gaussian functions and a variational approach that explicitly includes the nuclear motion in the calculations (i.e., the approach that does not assume the Born-Oppenheimer approximation). The leading relativistic and quantum electrodynamics corrections to the electron affinities were also calculated. The results are the most accurate theoretical values obtained for the studied systems to date. Our best estimates of the {sup 7}Li and {sup 6}Li EAs are 4984.9842(30) and 4984.9015(30) cm{sup -1}, respectively, and of the {sup 7}Li/{sup 6}Li EA isotope shift is 0.0827 cm{sup -1}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Empirical binary tomography calibration (EBTC) for the precorrection of beam hardening and scatter for flat panel CT

Purpose: Scatter and beam hardening are prominent artifacts in x-ray CT. Currently, there is no precorrection method that inherently accounts for tube voltage modulation and shaped prefiltration. Methods: A method for self-calibration based on binary tomography of homogeneous objects, which was proposed by B. Li et al. [''A novel beam hardening correction method for computed tomography,'' in Proceedings of the IEEE/ICME International Conference on Complex Medical Engineering CME 2007, pp. 891-895, 23-27 May 2007], has been generalized in order to use this information to preprocess scans of other, nonbinary objects, e.g., to reduce artifacts in medical CT applications. Further on, the method was extended to handle scatter besides beam hardening and to allow for detector pixel-specific and ray-specific precorrections. This implies that the empirical binary tomography calibration (EBTC) technique is sensitive to spectral effects as they are induced by the heel effect, by shaped prefiltration, or by scanners with tube voltage modulation. The presented method models the beam hardening correction by using a rational function, while the scatter component is modeled using the pep model of B. Ohnesorge et al. [''Efficient object scatter correction algorithm for third and fourth generation CT scanners,'' Eur. Radiol. 9(3), 563-569 (1999)]. A smoothness constraint is applied to the parameter space to regularize the underdetermined system of nonlinear equations. The parameters determined are then used to precorrect CT scans. Results: EBTC was evaluated using simulated data of a flat panel cone-beam CT scanner with tube voltage modulation and bow-tie prefiltration and using real data of a flat panel cone-beam CT scanner. In simulation studies, where the ground truth is known, the authors' correction model proved to be highly accurate and was able to reduce beam hardening by 97% and scatter by about 75%. Reconstructions of measured data showed significantly less artifacts than the standard reconstruction. Conclusions: EBTC appears to be an efficient algorithm to precorrect CT raw data for beam hardening and scatter and it can account for ray-dependent spectral variations as they occur due to the heel effect, due to shaped prefiltration, or due to variations in tube voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Fourier transform spectrometer without a beam splitter for the vacuum ultraviolet range: From the optical design to the first UV spectrum

We describe a Fourier transform (FT) spectrometer designed to operate down to 60 nm (20 eV) on a synchrotron radiation beamline for high resolution absorption spectrometry. As far as we know, such an instrument is not available below 140 nm mainly because manufacturing accurate and efficient beam splitters remains a major problem at these wavelengths, especially if a wide bandwidth operation is desired. In order to overcome this difficulty, we developed an interferometer based on wave front division instead of amplitude division. It relies on a modified Fresnel bimirror configuration that requires only flat mirrors. The instrument provides path difference scanning through the translation of one reflector. During the scanning, the moving reflector is controlled by an optical system that keeps its direction constant within a tolerable value and provides an accurate interferometric measurement of the path difference variation. Therefore, a regular interferogram sampling is obtained, producing a nominal spectral impulse response and an accurate spectral calibration. The first results presented in this paper show a measured spectral resolution of {delta}{sigma}=0.33 cm{sup -1} (interval between spectral samples). This was obtained with a sampling interval of 29 nm (path difference) and 512 K samples from a one-sided interferogram using a cosine FT. Such a sampling interval should allow the recording of large bandwidth spectra down to {lambda}=58 nm with an ultimate resolving power of 500 000 at this wavelength. In order to check the instrument performances, we first recorded an interferogram from a He-Ne stabilized laser. This provided the actual spectral impulse function, which was found to be fully satisfactory. The determination of the impulse response distortion and of the noise on the vacuum ultraviolet (VUV) spectral range provided accurate information in the sampling error profile over a typical scan. Finally, the instrument has been moved to the SU5 undulator-based synchrotron radiation beamline (Super-ACO facility, LURE, Orsay, France). A high resolution spectrum of O{sub 2} (the Schumann-Runge absorption bands, 185-200 nm) was computed from recorded interferograms using the beamline monochromator at the zeroth order to feed the instrument with an 11% relative bandwidth ''white'' beam (2003). These UV measurements are very close to those found in the literature, showing nominal performances of the FT spectrometer that should translate into an unprecedented resolving power at shortest VUV wavelengths. A recent upgrade (2007) and future developments will be discussed in light of the current installation of the upgraded FT spectrometer as a permanent endstation for ultrahigh resolution absorption spectrometry on the VUV beamline DESIRS at SOLEIL, the new French third generation synchrotron facility.

43 PARTICLE ACCELERATORS↗

Filterscope Techniques for Parasitic Signal Screening

Here, the filterscope diagnostic uses bandpass filters and photomultiplier tubes (PMTs) to detect specific spectral emission lines. A filterscope was used to measure the W I 400.88 nm line emission as a function of ion energy on the Radio Frequency Plasma Interaction Experiment (RF PIE) for the purpose of assessing W erosion on plasma-facing components (PFCs). Different filter techniques are being explored and compared in order to effectively screen out nearby impurity lines, like the Ar II 401.39 nm line. The effectiveness of these techniques is determined by comparing the measurements to a high-resolution 1.0 m Czerny–Turner spectrometer with 0.012 nm spectral resolution. The ability to filter out nearby impurity emissions is useful when imaging PFCs in fusion devices including divertor and antenna guard limiters. Initial results with a helium plasma show little difference between the two techniques at higher bias voltages. In a helium plasma at lower dc bias voltages, a two-filter technique with filters at two separate wavelengths was shown to be more effective at screening out background signals. Data collected with an argon plasma however show the technique with overlapping filters on the line of interest is a closer match to spectrometer data at lower dc bias voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A TEST OF THICK-TARGET NONUNIFORM IONIZATION AS AN EXPLANATION FOR BREAKS IN SOLAR FLARE HARD X-RAY SPECTRA

Solar nonthermal hard X-ray (HXR) flare spectra often cannot be fitted by a single power law, but rather require a downward break in the photon spectrum. A possible explanation for this spectral break is nonuniform ionization in the emission region. We have developed a computer code to calculate the photon spectrum from electrons with a power-law distribution injected into a thick target in which the ionization decreases linearly from 100% to zero. We use the bremsstrahlung cross section from Haug, which closely approximates the full relativistic Bethe-Heitler cross section, and compare photon spectra computed from this model with those obtained by Kontar et al., who used a step-function ionization model and the Kramers approximation to the cross section. We find that for HXR spectra from a target with nonuniform ionization, the difference (DELTAgamma) between the power-law indexes above and below the break has an upper limit between approx0.2 and 0.7 that depends on the power-law index delta of the injected electron distribution. A broken power-law spectrum with a higher value of DELTAgamma cannot result from nonuniform ionization alone. The model is applied to spectra obtained around the peak times of 20 flares observed by the Ramaty High-Energy Solar Spectroscopic Imager from 2002 to 2004 to determine whether thick-target nonuniform ionization can explain the measured spectral breaks. A Monte Carlo method is used to determine the uncertainties of the best-fit parameters, especially on DELTAgamma. We find that 15 of the 20 flare spectra require a downward spectral break and that at least six of these could not be explained by nonuniform ionization alone because they had values of DELTAgamma with less than a 2.5% probability of being consistent with the computed upper limits from the model. The remaining nine flare spectra, based on this criterion, are consistent with the nonuniform ionization model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dependence of Yb-169 absorbed dose energy correction factors on self-attenuation in source material and photon buildup in water

Purpose: Absorbed dose energy correction factors, used to convert the absorbed dose deposited in a LiF thermoluminescent dosimeter (TLD) into the clinically relevant absorbed dose to water, were obtained for both spherical volumetric sources and for the model 4140 HDR Yb-169 source. These correction factors have a strong energy dependence below 200 keV; therefore, spectral changes were quantified as Yb-169 photons traveled through both source material (Yb{sub 2}O{sub 3}) and water with the corresponding absorbed dose energy correction factors, f(r,{theta}), calculated as a function of location in a phantom. Methods: Using the MCNP5 Monte Carlo radiation transport simulation program, the Yb-169 spectrum emerging from spherical Yb{sub 2}O{sub 3} sources (density 6.9 g/cm{sup 3}) with radii between 0.2 and 0.9 mm were analyzed and their behavior compared against those for a point-source. The absorbed dose deposited to both LiF and H{sub 2}O materials was analyzed at phantom depths of 0.1-10 cm for each source radius and the absorbed dose energy correction factor calculated as the ratio of the absorbed dose to water to that of LiF. Absorbed dose energy correction factors for the Model 4140 Yb-169 HDR brachytherapy source similarly were obtained and compared against those calculated for the Model M-19 Ir-192 HDR source. Results: The Yb-169 average spectral energy, emerging from Yb{sub 2}O{sub 3} spherical sources 0.2-0.9 mm in radius, was observed to harden from 7% to 29%; as these photons traveled through the water phantom, the photon average energy softened by as much as 28% at a depth of 10 cm. Spectral softening was dependent on the measurement depth in the phantom. Energy correction factors were found to vary both as a function of source radius and phantom depth by as much as 10% for spherical Yb{sub 2}O{sub 3} sources. The Model 4140 Yb-169 energy correction factors depended on both phantom depth and reference angle and were found to vary by more than 10% between depths of 1 and 10 cm and angles of 0 deg. and 180 deg. This was in contrast to that of the Model M-19 Ir-192 source which exhibited approximately 3.5%-4.4% variation in its energy correction factors from phantom depths of 0.5-10 cm. The absorbed dose energy correction factor for the Ir-192 source, on the other hand, was independent of angle to within 1%. Conclusions: The application of a single energy correction factor for Yb-169 TLD based dosimetry would introduce a high degree of measurement uncertainty that may not be reasonable for the clinical characterization of a brachytherapy source; rather, an absorbed dose energy correction function will need to be developed for these sources. This correction function should be specific to each source model, type of TLD used, and to the experimental setup to obtain accurate and precise dosimetric measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evidence for multiple modes of uranium immobilization by an anaerobic bacterium

Microbial reduction of hexavalent uranium has been studied widely for its potential role in bioremediation and immobilization of soluble U(VI) in contaminated groundwater. More recently, some microorganisms have been examined for their role in immobilization of U(VI) via precipitation of uranyl phosphate minerals mediated by microbial phosphate release, alleviating the requirement for long-term redox control. Here, we investigated the mechanism of U(VI) removal mediated by an environmental isolate, strain UFO1, that is indigenous to the Field Research Center (FRC) in Oak Ridge, TN and has been detected in U(VI)-contaminated sediments. Changes in U(VI) speciation were examined in the presence and absence of the electron-shuttling moiety, anthraquinone-2,6-disulfonate (AQDS). Cell suspensions were capable of nearly complete removal of 100 μM U(VI) from solution within 48 hours; U(VI) removal was not dependent on the presence of an exogenous electron donor or AQDS, although AQDS increased the rate of U(VI) removal. X-ray Absorption Near Edge Structure (XANES) spectroscopic measurements indicated that U(IV) was the predominant oxidation state of uranium in cell suspensions in both the absence and presence of 100 μM AQDS. However, extended X-ray Absorption Fine Structure spectroscopy (EXAFS) measurements indicated that 17% of the cell-associated precipitates in a U(VI)-treated suspension that lacked AQDS had spectral characteristics consistent with a uranyl phosphate solid phase. The potential involvement of phosphate was consistent with observed increases in soluble phosphate concentrations over time in UFO1 cell suspensions, which suggested phosphate liberation from the cells. TEM-EDS confirmed the presence of uranyl phosphate with a U:P ratio consistent with autunite (1:1). EXAFS analyses further showed that U(IV) was present predominantly as a monomeric complex sorbed to carboxylate functional groups on biomass and also suggested that a fraction of the U(IV) was coordinated to phosphoryl ligands. These results suggest that strain UFO1 has the ability to facilitate U(VI) removal from solution via both reductive and phosphate precipitation mechanisms, and may potentially be useful for the remediation of U-contaminated sediments at the FRC or elsewhere.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗