Search NASA⌕ Search

SEARCH · Search NASA

Results for “parabolic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Aerodynamics of Slender Bodies at Mach Number of 3.12 and Reynolds Numbers from 2 x 10(exp 6) to 15 x 10(exp 6) IV : Aerodynamic Characteristics of Series of Four Bodies Having Near-parabolic Noses and Cylindrical Afterbodies

Pressure distributions and forces for a series of four bodies of revolution having nose-fineness ratios varying from 4 to 10 have been obtained and compared with theory for a Mach number of 3.12, a Reynolds number range of 2x10(sup)6 to 14x10(sup)6, and angles of attack from zero to 9 degrees. In general, a comparison of the experimental data with a second-order theory showed good agreement for the range of variables investigated.

BODIES - FITNESS RATIO↗

The piecewise-parabolic method in curvilinear coordinates

We derive interpolation formulae for a third-order finite difference method in curvilinear, orthogonal coordinate systems. These formulae serve as a supplement to Colella and Woodward's PPM scheme for problems where the coordinate origin is included in the computational domain. Numerical examples of the improved accuracy of the advection scheme near coordinate singularities are shown.

Blondin, John M.↗

Poly(arylene ether imidazole) surfacing films for flat and parabolic structures

Films of thermoplastic poly(arylene ether imidazole)s (PAEIs) are used as surface modifiers for neat resin panels and composite resin panels. The PAEI polymer contains imidazole groups along the backbone which co-cure, i.e., react chemically, with epoxies or bismaleimides during processing and thereby provide excellent adhesion between the PAEI film and an epoxy or bismaleimide neat resin or composite resin facesheet. The film provides good adhesion and a smooth surface to the finished part and acts as a release agent from the mold. The as-processed integral structures have very smooth (specular) surfaces, and since the film releases readily from a glass mold, no release agent is necessary. The PAEI film is thermally stable, resistant to electron radiation, and adheres tenaciously to the facesheet. The film maintains good adhesion even after thermal cycling from room temperature to approximately -196 C.

Connell, John W.↗

Guidance and Control During Direct-Descent Parabolic Reentry

The results of studies of four reentry guidance and control techniques for the energy management of vehicles returning to the earth at escape speeds are compared in this paper. The reentry trajectories are constrained to those of direct descent, that is, where the vehicle does not leave that portion of the atmosphere where useful aerodynamic forces are available after its initial entry. The guidance techniques compared are: (1) a piloted simulator study reference trajectory techniques; 2) An automatic controller using reference trajectory techniques; 3) A predictor system employing linear prediction (perturbation) techniques; and 4) A repetitive prediction system employing rapid-time computer techniques.

Foudriat, Edwin C.↗

A Discontinuous Galerkin Method for Parabolic Problems with Modified hp-Finite Element Approximation Technique

A recent paper is generalized to a case where the spatial region is taken in R(sup 3). The region is assumed to be a thin body, such as a panel on the wing or fuselage of an aerospace vehicle. The traditional h- as well as hp-finite element methods are applied to the surface defined in the x - y variables, while, through the thickness, the technique of the p-element is employed. Time and spatial discretization scheme based upon an assumption of certain weak singularity of double vertical line u(sub t) double vertical line 2, is used to derive an optimal a priori error estimate for the current method.

Kaneko, Hideaki↗

Cardiovascular responses to repetitive exposure to hyper- and hypogravity states produced by parabolic flight

Physiologic changes to repetitive hyper- and hypogravity stresses occurring during eight to ten parabolas on NASA's KC-135 aircraft were studied. Hemodynamic responses in 11 subjects in 4 different postures (supine, standing, sitting, and semisupine Space Shuttle launch position) were determined using noninvasive impedance cardiography. Five seconds of heart rate, cardiac index, thoracic fluid index, stroke index, ejection velocity index, and ventricular ejection time data were averaged during four different gravity (g) states: 1.3g (before parabola onset); 1.9g (parabola entry); 0g (parabola peak); and 1.7g (parabola exit) for each subject. The standing position was associated with the largest changes in the cardiovascular response to hypo- and hypergravity. The thoracic fluid index did not indicate a headward redistribution during transition from a simulated launch position to weightlessness. Analysis of the eight to ten parabolas revealed that, in general, values obtained at 1.8g differed from 1.6g, 0g differed from 1.6 and 1.3g, and 1.6g differed from 1.3g. The factors of gravity, thoracic fluid index, and cardiac index exhibited significant differences that were most likely to occur between parabola 1 versus parabolas 6, 7, and 8, and parabola 2 versus parabolas 4 through 8. Only the parameter of thoracic fluid index exhibited significance for parabolas 3 versus parabolas 6 and 7.

Space Flight↗