Search NASA⌕ Search

SEARCH · Search NASA

Results for “parabolic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

The piecewise-parabolic method in curvilinear coordinates

We derive interpolation formulae for a third-order finite difference method in curvilinear, orthogonal coordinate systems. These formulae serve as a supplement to Colella and Woodward's PPM scheme for problems where the coordinate origin is included in the computational domain. Numerical examples of the improved accuracy of the advection scheme near coordinate singularities are shown.

Blondin, John M.↗

Poly(arylene ether imidazole) surfacing films for flat and parabolic structures

Films of thermoplastic poly(arylene ether imidazole)s (PAEIs) are used as surface modifiers for neat resin panels and composite resin panels. The PAEI polymer contains imidazole groups along the backbone which co-cure, i.e., react chemically, with epoxies or bismaleimides during processing and thereby provide excellent adhesion between the PAEI film and an epoxy or bismaleimide neat resin or composite resin facesheet. The film provides good adhesion and a smooth surface to the finished part and acts as a release agent from the mold. The as-processed integral structures have very smooth (specular) surfaces, and since the film releases readily from a glass mold, no release agent is necessary. The PAEI film is thermally stable, resistant to electron radiation, and adheres tenaciously to the facesheet. The film maintains good adhesion even after thermal cycling from room temperature to approximately -196 C.

Connell, John W.↗

Guidance and Control During Direct-Descent Parabolic Reentry

The results of studies of four reentry guidance and control techniques for the energy management of vehicles returning to the earth at escape speeds are compared in this paper. The reentry trajectories are constrained to those of direct descent, that is, where the vehicle does not leave that portion of the atmosphere where useful aerodynamic forces are available after its initial entry. The guidance techniques compared are: (1) a piloted simulator study reference trajectory techniques; 2) An automatic controller using reference trajectory techniques; 3) A predictor system employing linear prediction (perturbation) techniques; and 4) A repetitive prediction system employing rapid-time computer techniques.

Foudriat, Edwin C.↗

A Discontinuous Galerkin Method for Parabolic Problems with Modified hp-Finite Element Approximation Technique

A recent paper is generalized to a case where the spatial region is taken in R(sup 3). The region is assumed to be a thin body, such as a panel on the wing or fuselage of an aerospace vehicle. The traditional h- as well as hp-finite element methods are applied to the surface defined in the x - y variables, while, through the thickness, the technique of the p-element is employed. Time and spatial discretization scheme based upon an assumption of certain weak singularity of double vertical line u(sub t) double vertical line 2, is used to derive an optimal a priori error estimate for the current method.

Kaneko, Hideaki↗

Cardiovascular responses to repetitive exposure to hyper- and hypogravity states produced by parabolic flight

Physiologic changes to repetitive hyper- and hypogravity stresses occurring during eight to ten parabolas on NASA's KC-135 aircraft were studied. Hemodynamic responses in 11 subjects in 4 different postures (supine, standing, sitting, and semisupine Space Shuttle launch position) were determined using noninvasive impedance cardiography. Five seconds of heart rate, cardiac index, thoracic fluid index, stroke index, ejection velocity index, and ventricular ejection time data were averaged during four different gravity (g) states: 1.3g (before parabola onset); 1.9g (parabola entry); 0g (parabola peak); and 1.7g (parabola exit) for each subject. The standing position was associated with the largest changes in the cardiovascular response to hypo- and hypergravity. The thoracic fluid index did not indicate a headward redistribution during transition from a simulated launch position to weightlessness. Analysis of the eight to ten parabolas revealed that, in general, values obtained at 1.8g differed from 1.6g, 0g differed from 1.6 and 1.3g, and 1.6g differed from 1.3g. The factors of gravity, thoracic fluid index, and cardiac index exhibited significant differences that were most likely to occur between parabola 1 versus parabolas 6, 7, and 8, and parabola 2 versus parabolas 4 through 8. Only the parameter of thoracic fluid index exhibited significance for parabolas 3 versus parabolas 6 and 7.

Space Flight↗

Test and Analysis of an Inflatable Parabolic Dish Antenna

NASA is developing ultra-lightweight structures technology for large communication antennas for application to space missions. With these goals in mind, SRS Technologies has been funded by NASA Glenn Research Center (GRC) to undertake the development of a subscale ultra-thin membrane inflatable antenna for deep-space applications. One of the research goals is to develop approaches for prediction of the radio frequency and structural characteristics of inflatable and rigidizable membrane antenna structures. GRC has teamed with NASA Langley Research Center (LaRC) to evaluate inflatable and rigidizable antenna concepts for potential space missions. GRC has completed tests to evaluate RF performance, while LaRC completed structural tests and analysis to evaluate the static shape and structural dynamic responses of a laboratory model of a 0.3 meter antenna. This paper presents the details of the tests and analysis completed to evaluate the radio frequency and structural characteristics of the antenna.

Gaspar, james L.↗

A Planar Dielectric-Filled-Parabolic-Feed Frequency Multiplier

In this paper, we present a novel quasi-optical all-planar frequency doubler that could provide an alternative approach to conventional waveguide circuits for millimeter- and submillimeter-wave signal generation. By utilizing a quad-bridge-diode configuration, we are able to isolate the input and the output circuits without the use of complicated filter structures.

frequency doubler waveguide circuits signal genera↗

Poly(arylene ether imidazole) surfacing films for flat and parabolic structures

Films of thermoplastic poly(arylene ether imidazole)s (PAEI)s are used as surface modifiers for neat resin panels and composite resin panels. The PAEI polymer contains imidazole groups along the backbone which co-cure, i.e., react chemically, with epoxies or bismaleimides during processing and thereby provide excellent adhesion between the PAEI film and an epoxy or bismaleimide neat resin or composite resin facesheet. The film provides good adhesion and a smooth surface to the finished part and acts as a release agent from the mold. The as-processed integral structures have very smooth (specular) surfaces, and since the film releases readily from a glass mold, no release agent is necessary. The PAEI film is thermally stable, resistant to electron radiation, and adheres tenaciously to the facesheet. The film maintains good adhesion even after thermal cycling from room temperature to .about. -196.degree. C.

Connell, John W.↗

Predicting Motion Sickness During Parabolic Flight

Background: There are large individual differences in susceptibility to motion sickness. Attempts to predict who will become motion sick have had limited success. In the present study we examined gender differences in resting levels of salivary amylase and total protein, cardiac interbeat intervals (R-R intervals), and a sympathovagal index and evaluated their potential to correctly classify individuals into two motion sickness severity groups. Methods: Sixteen subjects (10 men and 6 women) flew 4 sets of 10 parabolas aboard NASA's KC-135 aircraft. Saliva samples for amylase and total protein were collected preflight on the day of the flight and motion sickness symptoms were recorded during each parabola. Cardiovascular parameters were collected in the supine position 1-5 days prior to the flight. Results: There were no significant gender differences in sickness severity or any of the other variables mentioned above. Discriminant analysis using salivary amylase, R-R intervals and the sympathovagal index produced a significant Wilks' lambda coefficient of 0.36, p= 0.006. The analysis correctly classified 87% of the subjects into the none-mild sickness or the moderate-severe sickness group. Conclusions: The linear combination of resting levels of salivary amylase, high frequency R-R interval levels, and a sympathovagal index may be useful in predicting motion sickness severity.

Harm, Deborah L.↗

Parabolic Flight Testing of Aeroponic Plant Growth Systems and Super Omniphobic Surface Coatings

The purpose of this project is to gain valuable data from three separate experiments. One being an aeroponics watering system, another being a PONDS passive watering system, and the last a super omniphobic surface coating apparatus.There are two aeroponics watering systems that feed water and nutrients to "plant roots" inside of a contained box. The walls inside of the contained boxes have different surface textures and shapes but each contain the same nozzle and compressor set up as a control.There is one PONDS passive watering system that feeds water from a reservoir to a porous substrate utilizing wicking materials. There is one super omniphobic surface coating apparatus that feeds water into an apparatus allowing the water to make contact with three individual compartments in which glass beads with different coatings are carefully placed between two glass slides. The outcome will contribute to the advancement in self sustainment for space exploration. The status of the project when I started was to get the system built and ready for flight come November. My intended contributions are to assist with the build of the system.

Blockey, Jamie Lynn↗

Parabolic Deployable Antenna

A deployable antenna is described. The antenna comprises a mesh attached to foldable ribs, a hub and a sub-reflector. The antenna can be stowed in a tight space for launching in space, and later deployed by extending out of its container. The antenna is designed to work in the Ka band or other bands and can increase data rates and function as a radio antenna.

Thomson, Mark W.↗

Design and Modeling of the Off-Axis Parabolic Deformable (OPD) Mirror Laboratory

Coronagraph-equipped direct imaging missions need an active wavefront control system to cancel out the optical aberrations that degrade the performance of the coronagraphs. A fast steering mirror is used to control Line-of-Sight (LoS) pointing error caused by the telescope jitter. In addition to controlling other low-order aberrations such as astigmatism and coma, high stroke, high actuator density deformable mirrors (DMs) are also used to control the electric field at the required high spatial frequencies. We are designing a testbed to verify a different deformable architecture, where the powered optic in the optical train are controllable and have lower actuator count compared to the existing DMs with flat nominal surfaces. This simplifies the packaging issue for space missions and reduces both cost and risk of having the entire coronagraph instrument's performance depending on one or two high-actuator count DMs. The testbed would also be capable of testing different low-order wavefront sensing algorithms, which focuses in the near-term on a new adaptive Kalman filtering and gradient decent method to estimate the harmonic LoS errors that affect space telescopes. In long run, we would test different machine learning techniques to estimate low-order aberrations and non-linear algorithms for digging the region of high contrast called the dark holes (DH).

Subedi, Hari↗

Design and Modeling of the Off-Axis Parabolic Deformable Mirror Laboratory

Coronagraph-equipped direct imaging missions need an active wavefront control system to cancel out the optical aberrations that degrade the performance of the coronagraphs. A fast steering mirror is used to control Line-of-Sight (LoS) pointing error caused by the telescope jitter. In addition to controlling other low-order aberrations such as astigmatism and coma, high stroke, high actuator density deformable mirrors (DMs) are also used to control the electric field at the required high spatial frequencies. We are designing a testbed to verify a different deformable architecture, where the powered optic in the optical train are controllable and have lower actuator count compared to the existing DMs with flat nominal surfaces. This simplifies the packaging issue for space missions and reduces both cost and risk of having the entire coronagraph instrument's performance depending on one or two high-actuator count DMs. The testbed would also be capable of testing different low-order wavefront sensing algorithms, which focuses in the near-term on a new adaptive Kalman filtering and gradient decent method to estimate the harmonic LoS errors that affect space telescopes. In long run, we would test different machine learning techniques to estimate low-order aberrations and non-linear algorithms for digging the region of high contrast called the dark holes (DH).

Communication↗