Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase coherence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

PSR J2030+364I: Radio Discovery and Gamma-ray Study of a Middle-aged Pulsar in the Now Identified Fermi-LAT Source 1FGL J2030.0+3641

In a radio search with the Green Bank Telescope of three unidentified low Galactic latitude Fermi-LAT sources, we have discovered the middle-aged pulsar J2030+3641, associated with IFGL J2030.0+3641 (2FGL J2030.0+3640). Following the detection of gamma-ray pulsations using a radio ephemeris, we have obtained a phase-coherent timing solution based on gamma-ray and radio pulse arrival times that spans the entire Fermi mission. With a rotation period of 0.28, spin-down luminosity of 3 x 10(exp 34) erg/s, and characteristic age of 0.5 Myr, PSR J2030+3641 is a middle-aged neutron star with spin parameters similar to those of the exceedingly gamma-ray-bright and radio-undetected Geminga. Its gamma-ray flux is 1 % that of Geminga, primarily because of its much larger distance, as suggested by the large integrated column density of free electrons, DM = 246 pc/cu cm. We fit the gamma-ray light curve, along with limited radio polarimetric constraints, to four geometrical models of magnetospheric emission, and while none of the fits have high significance some are encouraging and suggest that further refinements of these models may be worthwhile. We argue that not many more non-millisecond radio pulsars may be detected along the Galactic plane that are responsible for LAT sources, but that modified methods to search for gamma-ray pulsations should be productive - PSR J2030+364 I would have been found blindly in gamma rays if only > or approx. 0.8 GeV photons had been considered, owing to its relatively flat spectrum and location in a region of high soft background.

Camilo, F.↗

IGR J170626143 is an Accreting Millisecond X-Ray Pulsar

We present the discovery of 163.65 Hz X-ray pulsations from IGR J17062−6143 in the only observation obtained from the source with the Rossi X-ray Timing Explorer. This detection makes IGR J17062−6143 the lowest frequency accreting millisecond X-ray pulsar presently known. The pulsations are detected in the 2-12 keV band with an overall significance of 4.3sigma and an observed pulsed amplitude of 5.54% +/-0.67% (in this band). Both dynamic power spectral and coherent phase timing analysis indicate that the pulsation frequency is decreasing during the approx. =1.2 ks observation in a manner consistent with orbital motion of the neutron star. Because the observation interval is short, we cannot precisely measure the orbital period; however, periods shorter than 17 minutes are excluded at 90% confidence. For the range of acceptable circular orbits the inferred binary mass function substantially overlaps the observed range for the AMXP population as a whole.

stars: neutron↗

A Novel RF Architecture for Simultaneous Communication, Navigation, and Remote Sensing with Software-Defined Radio

The rapid growth of SmallSat and CubeSat missions at NASA has necessitated a re-evaluation of communication and remote-sensing architectures. Novel designs for CubeSat-sized single-board computers can now include larger Field-Programmable Gate Arrays (FPGAs) and faster System-on-Chip (SoCs) devices. These components substantially improve onboard processing capabilities so that varying subsystems no longer require an independent processor. By replacing individual Radio Frequency (RF) systems with a single software-defined radio (SDR) and processor, mission designers have greater control over reliability, performance, and efficiency. The presented architecture combines individual processing systems into a single design and establishes a modular SDR architecture capable of both remote-sensing and communication applications. This new approach based on a multi-input multi-output (MIMO) SDR features a scalable architecture optimized for Size, Weight, Power, and Cost (SWaP-C), with sufficient noise performance and phase-coherence to enable both remote-sensing and navigation applications, while providing a communication solution for simultaneous S-band and X-band transmission. This SDR design is developed around the NASA CubeSat Card Standard (CS2) that provides the required modularity through simplified backplane and interchangeable options for multiple radiation-hardened/tolerant processors. This architecture provides missions with a single platform for high-rate communication and a future platform to develop cognitive radio systems.

Advanced Avionics, Hybrid Processing, Data Process↗

Anti-Glitches in the Ultraluminous Accreting Pulsar NGC 300 ULX-1 Observed with NICER

We present evidence for three spin-down glitches (or “anti-glitches”) in the ultraluminous accreting X-ray pulsar NGC 300 ULX-1, in timing observations made with the Neutron Star Interior Composition Explorer. Our timing analysis reveals three sudden spin-down events of magnitudes Δν=−23, −30, and −43 μHz (fractional amplitudes Δν/ν=−4.4, −5.5, and −7.7×10−4). We determined fully phase-coherent timing solutions through the first two glitches, giving us high confidence in their detection, while the third candidate glitch is somewhat less secure. These are larger in magnitude (and opposite in sign) than any known radio pulsar glitch. This may be caused by the prolonged rapid spin up of the pulsar, causing a sudden transfer of angular momentum between the superfluid and non-superfluid components of the star. We find no evidence for profile or spectral changes at the epochs of the glitches, supporting the conclusion that these are due to the same process as in normal pulsar glitches, but in reverse.

Paul S Ray↗

A Real-time View of Orbital Evolution in HM Cancri

HM Cancri is a double-degenerate binary with the shortest orbital period presently known. The 5.36 minute period is seen as a large amplitude, soft X-ray modulation, likely resulting from a hot-spot produced by direct impact accretion. With such a7short orbital period it is expected to have a gravitational wave luminosity comparable8to or larger than that in the X-ray, and its orbital frequency is known to be increasing9at a rate consistent with the expected loss of angular momentum due to gravitational radiation. We use recent Neutron Star Interior Composition Explorer(NICER) observations to extend its long-term X-ray timing baseline to almost 20 yr. Phase coherent timing of these new data combined with existing Chandra data demonstrates conclusively that the rate of orbital frequency increase is slowing, and we measure a non-zero f0=8.95 ± 1.4 x 1027 Hz s2, to our knowledge the first such measurement of its kind for any compact astrophysical binary. With the simultaneous high precision measurement of f0= 3.557 ± 0.005 x 1016 Hz s1, we estimate that the system17will reach its maximum orbital frequency of fmax 3.1172091 mHz in 1,260 ± 200 yr, indicating that the system is close to its epoch of maximum orbital frequency. Assuming mass transfer is conservative, the measurement of f<0 implies that the20accretion rate from the donor is growing, with 5.4 x 1010<M2<4.0 x 1010 M⊙yr2. Further quantitative comparisons with theoretical models should enable more precise inferences regarding its current evolutionary state.

White dwarfs↗

Discovery and Timing of Three Millisecond Pulsars in Radio and Gamma-Rays with the Giant Metrewave Radio Telescope and Fermi Large Area Telescope

We performed deep observations to search for radio pulsations in the directions of 375 unassociated Fermi Large Area Telescope γ-ray sources using the Giant Metrewave Radio Telescope (GMRT) at 322 and 607 MHz. In this paper we report the discovery of three millisecond pulsars (MSPs), PSR J0248+4230, PSR J1207–5050, and PSR J1536–4948. We conducted follow-up timing observations for ∼5 yr with the GMRT and derived phase-coherent timing models for these MSPs. PSR J0248+4230 and J1207–5050 are isolated MSPs having periodicities of 2.60 ms and 4.84 ms. PSR J1536–4948 is a 3.07 ms pulsar in a binary system with an orbital period of ∼62 days about a companion of a minimum mass of 0.32 M⊙. We also present multifrequency pulse profiles of these MSPs from the GMRT observations. PSR J1536–4948 is an MSP with an extremely wide pulse profile having multiple components. Using the radio timing ephemeris we subsequently detected γ-ray pulsations from these three MSPs, confirming them as the sources powering the γ-ray emission. For PSR J1536–4948 we performed combined radio–γ-ray timing using ∼11.6 yr of γ-ray pulse times of arrival (TOAs) along with the radio TOAs. PSR J1536–4948 also shows evidence for pulsed γ-ray emission out to above 25 GeV, confirming earlier associations of this MSP with a ≥10 GeV point source. The multiwavelength pulse profiles of all three MSPs offer challenges to models of radio and γ-ray emission in pulsar magnetospheres.

High energy astrophysics↗

Juno Gravity Science: Five Years of Radio Science Operations with Ka-band Uplink

Since entering orbit on July 4, 2016, the Juno spacecraft has executed 34 closest approach passes of Jupiter, completing the prime mission. During each closest approach, called perijove, the spacecraft comes within 4,000 km of the cloud tops and the motion of the spacecraft becomes perturbed by the gravitational field of Jupiter. These small changes in the motion of the spacecraft are detected using the Juno Gravity Science Instrument by measuring the Doppler shift of the radio link between the Juno spacecraft and NASA’s Deep Space Network (DSN). During a majority of these closest approach passes, the 34-meter DSS-25 antenna transmits simultaneous X-band and Ka-band uplink to the spacecraft. Juno’s onboard X-band transponder and Ka-band translator phase-coherently return the signals back to Earth for reception at the same DSS-25 antenna. The precise frequency of these signals is measured by processing open-loop recordings of the signal. These measurements, characterized by ~5-10 micron/sec accuracies (after calibration of charged particle noise and Earth troposphere), have probed the gravity field of Jupiter to unprecedented precision, allowing for discoveries of Jupiter’s core size and depth of the zonal winds. Successful operations of the instrument during perijoves requires careful planning and coordination between DSN engineers, the Juno project, and the Juno science team. This work discusses the operations of the Juno Gravity Science Instrument after five years of prime mission operations. Lessons learned are documented to be applied to future missions and the Juno extended mission. Although the Juno extended mission formally started on August 1, 2021, on June 7, 2021, the trajectory was modified with a flyby of Ganymede, the third Galilean moon of Jupiter. Gravity and radio science investigations of Jupiter and its moons will continue to play a key role in Juno’s objectives during the extended mission.

Oudrhiri, Kamal↗

Analysis of a Novel Diffractive Scanning Wire Beam Position Monitor (BPM) for Discriminative Profiling of Electron Vs. X Ray Beams

Recent numerical studies of Free Electron Lasers (FELs) operating in the Self Amplified Spontaneous Emission (SASE) regime indicate a large sensitivity of the gain to the degree of transverse overlap (and associated phase coherence) between the electron and photon beams traveling down the insertion device. Simulations of actual systems imply that accurate detection and correction for this relative loss of overlap, rather than correction for the absolute departure of the electron beam from a fixed axis, is the preferred function of an FEL amplifier's Beam Position Monitor (BPM) and corrector systems. In this note we propose a novel diffractive BPM with the capability of simultaneously detecting and resolving the absolute (and relative) transverse positions and profiles of electron and x-ray beams co-propagating through an undulator. We derive the equations governing the performance of the BPM and examine its predicted performance for the SLAC Linac Coherent Light Source (LCLS), viz., for profiling multi-GeV electron bunches co-propagating with one-to-several-hundred keV x-ray beams. Selected research and development (r&d) tasks for fabricating and testing the proposed BPM are discussed.

43 PARTICLE ACCELERATORS↗

Multi-Cavity Proton Cyclotron Accelerator: An Electron Counterpart

A multi-cavity multi-frequency proton cyclotron accelerator has been proposed. It would utilize cyclotron resonance in each of eight cavities of uniformly diminishing frequency in a uniform magnetic field to comprise a compact (25 m) 1 GeV pro ton accelerator, according to simulation results*. A four cavity electron counterpart is under construction to test the mechanism of the multi-cavity setup, including phase acceptance, energy gain, and growth of energy spread and emittance for parameters equivalent to the proton case. The four electron counterpart cavities are driven by kW-level phase coherent RF sources at 1.5, 1.8, 2.1 and 2.4 GHz. Each cavity operates in the rotating TE111 mode and includes two feeds in quadrature to drive the rotating mode and two RF pickoffs for diagnostics. The electron beam source is a low-current gun with a BaO cathode which operates at -1200V and <50 microamps. After traversing the cavities, the beam is collected on either a Faraday cup or is imaged with a phosph or screen. Details of the setup and initial results from experiments with the four cavity electron counterpart will be presented.

43 PARTICLE ACCELERATORS↗

Transceivers and receivers for quantum key distribution and methods pertaining thereto

Various technologies for performing continuous-variable (CV) and discrete-variable (DV) quantum key distribution (QKD) with integrated electro-optical circuits are described herein. An integrated DV-QKD system uses Mach-Zehnder modulators to modulate a polarization of photons at a transmitter and select a photon polarization measurement basis at a receiver. An integrated CV-QKD system uses wavelength division multiplexing to send and receive amplitude-modulated and phase-modulated optical signals with a local oscillator signal while maintaining phase coherence between the modulated signals and the local oscillator signal.

47 OTHER INSTRUMENTATION↗

Materials and devices for fundamental quantum science and quantum technologies

Technologies operating on the basis of quantum mechanical laws and resources such as phase coherence and entanglement are expected to revolutionize our future. Quantum technologies are often divided into four main pillars: computing, simulation, communication, and sensing & metrology. Moreover, a great deal of interest is currently also nucleating around energy-related quantum technologies. In this Perspective, we focus on advanced superconducting materials, van der Waals materials, and moiré quantum matter, summarizing recent exciting developments and highlighting a wealth of potential applications, ranging from high-energy experimental and theoretical physics to quantum materials science and energy storage.

Polini, Marco↗

Exploring Biosignatures Associated with Thenardite by Geomatrix-Assisted Laser Desorption/Ionization Fourier Transform Mass Spectrometry (GALDI-FTMS)

Geomatrix-assisted laser desorption/ionization (GALDI) in conjunction with a Fourier transform mass spectrometer (FTMS) has been employed to determine how well bio/organic molecules associated with the mineral thenardite (Na2SO4) can be detected. GALDI is based on the ability of the mineral host to assist desorption and ionization of bio/organic molecules without additional sample preparation. When glycine was mixed with thenardite, glycine was deprotonated to produce C2H4NO2 at m/z 74.025. The combination of stearic acid with thenardite produced a complex cluster ion at m/z 390.258 in the negative mode, which was assigned a composition of C18H39O7Na . A natural sample of thenardite from Searles Lake in California also produced a peak at m/z 390.260. The bio/organic signatures in both the laboratory-based and natural samples were heterogeneously dispersed as revealed by chemical imaging. The detection limits for the stearic acid and thenardite combination was estimated to be 3 parts per trillion or ~7 zeptomoles per laser spot. Attempts to improve the signal-to-noise ratio by co-adding FTMS data predetermined to contain the biosignatures of interest revealed problems due to a lack of phase coherence between data sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase Lag and Coherence Function of X-Ray Emission from Black Hole Candidate XTE J1550-564

We report the results from measuring the phase lag and coherence function of X-ray emission from black hole candidate XTE J1550-564. These temporal X-ray properties have been recognized to be increasingly important in providing important diagnostics of the dynamics of accretion flows around black holes. For XTE J1550-564, we found significant hard lag-the X-ray variability in high-energy bands lags behind that in low-energy bands-associated both with broadband variability and quasi-periodic oscillation (QPO) . However, the situation is more complicated for the QPO: while hard lag was measured for the first harmonic of the signal, the fundamental component showed significant soft lag. Such behavior is remarkably similar to what was observed of microquasar GRS 1915+105. The phase lag evolved during the initial rising phase of the 1998 outburst. The magnitude of both the soft and hard lags of the QPO increases with X-ray flux, while the Fourier spectrum of the broadband lag varies significantly in shape. The coherence function is relatively high and roughly constant at low frequencies and begins to drop almost right after the first harmonic of the QPO. It is near unity at the beginning and decreases rapidly during the rising phase. Also observed is that the more widely separated the two energy bands are, the less the coherence function between the two. It is interesting that the coherence function increases significantly at the frequencies of the QPO and its harmonics. We discuss the implications of the results on the models proposed for black hole candidates.

Cui, Wei↗

A 100 Mbps resonant cavity phase modulator for coherent optical communications

A resonant cavity electro-optic phase modulator has been designed and implemented to operate at a data rate of 100 Mbps. The modulator consists of an electro-optic crystal located in a highly resonant cavity. The cavity is electro-optically tuned on and off resonance, and the phase dispersion near the cavity resonance provides the output phase modulation. The performance of the modulator was measured by first heterodyne detecting the signal to an intermediate frequency and then measuring the spectral characteristics using an RF spectrum analyzer. The measured phase shift is shown to be in good agreement with the theoretical predictions.

Chen, Chien-Chung↗

3D Columnar Phase of Stacked Short DNA Organized by Coherent Membrane Undulations

We report on the discovery of a new organized lipid-nucleic acid phase upon intercalation of blunt duplexes of short DNA (sDNA) within cationic multilayer fluid membranes. End-to-end interactions between sDNA leads to columnar stacks. At high membrane charge density, with the inter-sDNA column spacing (d sDNA ) comparable but larger than the diameter of sDNA, a 2D columnar phase (i.e., a 2D smectic) is found similar to the phase in cationic liposome-DNA complexes with long lambda-phage DNA. Remarkably, with increasing d sDNA as the membrane charge density is lowered, a transition is observed to a 3D columnar phase of stacked sDNA. This occurs even though direct DNA–DNA electrostatic interactions across layers are screened by diffusing cationic lipids near the phosphate groups of sDNA. Softening of the membrane bending rigidity (κ), which further promotes membrane undulations, significantly enhances the 3D columnar phase. These observations are consistent with a model by Schiessel and Aranda-Espinoza where local membrane undulations, due to electrostatically induced membrane wrapping around sDNA columns, phase lock from layer-to-layer, thereby precipitating coherent “crystal-like” undulations coupled to sDNA columns with long-range position and orientation order. The finding that this new phase is stable at large d sDNA and enhanced with decreasing κ is further supportive of the model where the elastic cost of membrane deformation per unit area around sDNA columns (∝ κh 2 /d sDNA 4 , h 2 = sum of square of amplitudes of the inner and outer monolayer undulations) is strongly reduced relative to the favorable electrostatic attractions of partially wrapped membrane around sDNA columns. Here, the findings have broad implications in the design of membrane-mediated assembly of functional nanoparticles in 3D.

59 BASIC BIOLOGICAL SCIENCES↗

Detection of coherent superpositions of phase states by full counting statistics in a Bose Josephson junction

We study a Bose Josephson junction realized with a double-well potential. We propose a strategy to observe the coherent superpositions of phase states occurring during the time evolution after a sudden rise of the barrier separating the two wells. We show that their phase content can be obtained by the full counting statistics of the spin-boson operators characterizing the junction, which could be mapped out by repeated measurements of the population imbalance after rotation of the state. This measurement can distinguish between coherent superpositions and incoherent mixtures, and can be used for a two-dimensional tomographic reconstruction of the phase content of the state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the temperature dependence of Young's modulus of cartilage by phase-sensitive optical coherence elastography

The development of an effective system to monitor the changes in the elastic properties of cartilage tissue with increasing temperature in laser reconstruction is an urgent practical task. In this paper, the use of phase-sensitive optical coherence elastography for detection of elastic waves in the sample has allowed Young's modulus of cartilage tissue to be measured directly during heating. Young's modulus was calculated from the group velocity of propagation of elastic waves excited by means of a system supplying focused air pulses. The measurement results are in agreement with the results of measurements of the modulus of elasticity under mechanical compression. The technique developed allows for noninvasive measurements; its development is promising for the use in vivo. (laser biophotonics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase decorrelation of coherent structures in a free shear layer

The vortices near the origin of an initially laminar mixing layer have a single frequency with a well-defined phase; i.e., there is little phase jitter. Further downstream, however, the phase jitter increases suddenly. Even when the flow is forced, this same transition is observed. The forcing partially loses its influence because of the decorrelation of the phase between the forcing signal and the passing coherent structures. In the present investigation, this phenomenon is documented and the physical mechanism responsible for the phase decorrelation is identified.

Ho, Chih-Ming↗