An Agent-Based Modeling Approach for Spatiotemporal Optimization of Electric Vehicle Fast-Charging Station Demand

With increasing electric vehicle (EV) adoption, managing public fast-charging demand effectively is crucial to avoid grid strain. This study investigates the potential of using dynamic pricing schemes to address this challenge. Presented in this study is a scalable agent-based simulation framework, which is applied to a case study in Richmond, Virginia, that assumes a 50% EV adoption rate in 2040. Two pricing schemes are compared: (1) a dynamic-pricing scheme based on station utilization and (2) a dynamic-pricing scheme based on peak power at the station. These schemes are compared to two baseline scenarios: (1) unscheduled first-come, first-served and (2) scheduled with constant price. The study’s results suggest that dynamic pricing has the potential to influence EV charging behavior, inducing both spatial and temporal shifts, but does so at the cost of inducing inconvenience to EV drivers. The results suggest the peak-power dynamic pricing scheme has the potential to mitigate peak demand pressures on the grid with minimal inconvenience, offering a promising approach for sustainable EV charging infrastructure expansion.

33 - ADVANCED PROPULSION SYSTEMS↗

Grid-interactive Efficient Buildings Projects Summary

Through its grid-interactive efficient building (GEB) research, DOE’s Building Technologies Office seeks to build on existing energy-efficiency efforts to optimize the interplay among energy efficiency, demand response, behind-the-meter generation and energy storage to increase the flexibility of demand-side management. BTO envisions a future where buildings dynamically operate as part of a low cost, reliable electricity grid while meeting the needs and expectations of building occupants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring Dynamic P-Q Capability and Abnormal Operations of Inverter-Based Resources

Nowadays, inverter-based resources are rapidly growing in electric power systems. On the other side, abnormal inverter operations are also occurring more often. Traditionally, inverter PQ capability charts are employed by electric utility companies to ensure safe and reliable operations of inverter-based resources. However, it is found in this paper that existing inverter PQ capability charts do not address the operating characteristics of an inverter correctly, which can result in irregular and unstable inverter operations. Here in this paper, a novel study is conducted to investigate inverter PQ capability charts, where constraints that are specific to an inverter are considered. It is found in this paper that the inverter PQ capability charts exhibit a unique dynamic nature under uncertain grid conditions. This dynamic nature has not been considered by the industry in managing, designing, and controlling an inverter as well as in developing international standards for inverter-based resources. Via both electromagnetic transient simulation and hardware experimental investigations, it is found that the dynamic PQ capability nature, together with the limitations of the existing control methods, are the underlying causes of many unusual inverter operations that have been reported in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ModuleOT: A Hardware Security Module for Operational Technology: Preprint

With increasing penetration levels of distributed energy resources (DERs) on the distribution grid, as well as new technological advancements in the cyber space, new cyberattack vectors are being introduced, and the available attack surface is constantly increasing. Despite this increasing risk, the standard IEEE 1547-2018 does not yet recommend cybersecurity measures for DERs. To address this and to better protect data on the distribution grid - from the standpoints information security as well as operational security - ModuleOT has been developed. The module aims to significantly reduce cyberattack vectors by improving data privacy for user applications. This is accomplished by performing the core functions of encryption, authentication, authorization, certificate management, and user access control. The module integrates a custom security application with hardware cryptographic acceleration. The application secures all communications using Transmission Control Protocol over Internet Protocol (TCP/IP). These include the three most commonly used communications protocols for power systems information exchange: Modbus, Distributed Network Protocol 3 (DNP3), and Smart Energy Profile 2.0 (SEP2.0). These three protocols are also supported by IEEE 1547-2018 for all DER devices. This paper tests the data encryption/decryption feature on a physical networking test bed with emulated Modbus devices reporting grid data and presents the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peer-to-Peer Communication Trade-Offs for Smart Grid Applications: Preprint

Peer-to-peer energy management systems for smart grids require developers to consider the trade-offs between the amount of communication traffic generated and the quality and speed of convergence of the control algorithms that are deployed. Employing a fully connected communication causes messages to scale exponentially with the number of nodes, while using a sparse connectivity causes less information dissemination leading to degradation of the algorithm performance. The best communication topology for a particular application lies somewhere in between and often requires empirical evaluation by application designers. Existing methods do not put focus on the needs for smart grid applications, which is information dissemination throughout the network and they do not provide a flexible solution for application developers to prototype and deploy different topologies without modifying the application code. This paper introduces a configurable virtual communication topology framework TopLinkMgr, allowing users to specify any chosen communication topology and deploy peer-to-peer applications using it. It also introduces a self-adaptive, fault-tolerant topology management algorithm, Bounded Path Dissemination that can ensure the dissemination of information to all peers within a specified threshold for a sparsely connected topology. Experiments show that the algorithm improves on convergence speed and accuracy over state-of-the-art methods and is also robust against node failures. The results indicate the possibility of achieving a close-to optimal convergence without overloading the network allowing the realization of peer-to-peer control platforms covering larger and more complex power systems.

Bounded Path Dissemination↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Resumen del Informe de Progreso del PR100: Resultados Preliminares del Modelo y Conjuntos de Datos Solares y Eólica de Alta Resolución

El estudio de Resiliencia y Transiciones a 100% Energia Renovable de Puerto Rico (PR100) es un estudio de 2 anos de la Oficina de Movilizacion de la Red del Departamento de Energia y seis laboratorios nacionales para analizar exhaustivamente las rutas dirigidas por las personas interesadas hacia un futuro de energia limpia en Puerto Rico. En el Ano 1 del estudio, el equipo PR100, creo y analizo los modelos que alcanzan las metas de energia renovable para Puerto Rico y los objetivos de resiliencia energetica a corto y largo plazo. Este informe, que resume el progreso en el Ano 1, proporciona las consideraciones que pueden informar posibles decisiones de fondos e implementacion potenciales por parte de las agencias federales y locales clave y partes interesadas. El resumen de este informe sigue a la publicacion en julio 2022 de un Informe de Seis Meses de Progreso de PR100. (en ingles y espanol), asi como webinarios publicos en febrero 2022 para lanzar el estudio y julio 2022 para presentar la actualizacion a 6 meses. Un informe final por escrito y visuales por la web seran publicados a finales del 2023. Todas las publicaciones y eventos publicos asociados con el estudio estaran disponibles en ingles y espanol. This report is also available in English https://www.nrel.gov/docs/fy23osti/85018.pdf.

14 SOLAR ENERGY↗

A Real-Time Operations Manual for the IEEE 118 Bus Transmission Model

This document presents a sample operations manual for the IEEE 118 Bus Model, which is a synthetic test case developed in 1962 from a section of the transmission grid operated by American Electric Power (AEP). The model is one of the most used synthetic test cases for development of power system applications and is referenced by over 9000 papers. However, the model lacks any context for use with real-time energy management system (EMS) applications, including common considerations, such as generator ramp rates, reactive capabilities, operating limits, and other information typically used by power system operators for real-time decision making. This manual divides the IEEE 118 Bus Model into three operating areas, defines various operating limits, and sets recommended operating procedures for responding to a few types of emergency operating conditions. The manual can be used in support of a wide variety of human-in-the-loop evaluation methodologies for new advanced power applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State Estimation-Based Distributed Energy Resource Optimization for Distribution Voltage Regulation in Telemetry-Sparse Environments Using a Real-Time Digital Twin

Real-time state estimation using a digital twin can overcome the lack of in-field measurements inside an electric feeder to optimize grid services provided by distributed energy resources (DERs). Optimal reactive power control of DERs can be used to mitigate distribution system voltage violations caused by increased penetrations of photovoltaic (PV) systems. In this work, a new technology called the Programmable Distribution Resource Open Management Optimization System (ProDROMOS) issued optimized DER reactive power setpoints based-on results from a particle swarm optimization (PSO) algorithm wrapped around OpenDSS time-series feeder simulations. This paper demonstrates the use of the ProDROMOS in a RT simulated environment using a power hardware-in-the-loop PV inverter and in a field demonstration, using a 678 kW PV system in Grafton (MA, USA). The primary contribution of the work is demonstrating a RT digital twin effectively provides state estimation pseudo-measurements that can be used to optimize DER operations for distribution voltage regulation.

Darbali-Zamora, Rachid↗

Validating Protection System Behavior with Machine Learning in a Master State Overseer

As power system protection devices continue the widespread transition from analog to digital, they become increasingly intricate. The internal functions and communication between critical grid components must now be significantly more complex to keep up with the demands of the modern smart grid. This brings increased difficulty in maintenance and monitoring, making it harder to identify potential misoperation, power anomalies, and cyber threats. Such issues are often only pinpointed after an exhaustive and costly post-mortem analysis, when a major outage or damage has already occurred. A solution is needed for validating protection systems as they operate, independently evaluating grid state and confirming whether the protection system is behaving accordingly. As opposed to incident response, this acts as a constant verification mechanism that raises a flag when subtler issues are noticed, catching them earlier and preventing larger incidents. This work presents the implementation of such a system, expanding on the prototype developed by the authors in a previous paper. This is accomplished with a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. Additionally, this system is contextualized within a larger, modular Master State awareness Overseer (MSO) framework, responsible for monitoring, analyzing, and managing an electric grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Integration of a Smart Outlet-Based Plug Load Management System with a Building Automation System

The growth of and reliance on renewable energy necessitate a multi-pronged approach to achieve grid reliability and economics. As they represent a notable portion of U.S. energy consumption, commercial buildings must play an active role in this effort. Conserving energy and responding to grid conditions through demand flexibility can be achieved through the integration of major building systems. Integration of plug and process loads with lighting and heating, ventilation, and air conditioning systems maximizes the effectiveness of integrated building energy management. In this research, we demonstrate the integration of smart outlets into a building automation system. We cover the installation process as well as the architecture required for smart outlets to communicate data to the building automation system and to receive commands back. After recording power measurements for one week as a baseline, we configured the building automation system to turn the smart outlets on and off according to a set schedule. This resulted in energy savings of 66% during 1 week on 25 plug loads. This work demonstrates that grid-interactive efficient buildings are achievable through building system integration.

building automation system↗

Decomposition characteristics of C4F7N-based SF6-alternative gas mixtures

C4F7N [2,3,3,3-tetrafluoro-2-(trifluoromethyl)propanenitrile]/CO2 gas mixtures are being developed as an eco-friendly electrical insulator to replace SF6, the most potent greenhouse industrial gaseous dielectric. However, recent studies have reported complicated and often conflicting decomposition pathways for C4F7N/CO2 gas mixtures, which has raised concerns. In this work, the decomposition characteristics of C4F7N/CO2 gas mixtures were studied comprehensively by both designed computations and experiments. Computations were performed starting from fundamental propositions of C4F7N/CO2 decompositions, which were further experimentally verified by pyrolysis, long-term thermal aging with/without catalytic materials (industrial-grade molecular sieves 4A), and electrical decomposition by spark discharge. The results of both computations and experiments suggest that in an ideal thermal decomposition, C4F7N is likely to decompose into C2F6 and small fluoronitriles first at high temperatures. The generation of C3F6 and C2N2 from C4F7N thermal decomposition at lower temperatures appears because of the catalytic effect of incompatible materials, for example, the industrial-grade molecular sieves 4A that we tested. The electron impact dissociation of C4F7N plays an important role in C4F7N electrical decomposition, leading to additional formation of distinctive small molecules of CF4 and C2N2 of low concentrations. It was pointed out based on a real arcing test in a load disconnector that the decomposition of C4F7N gas mixtures in real applications will be at a much moderate and manageable rate than what was obtained from the highly accelerated laboratory tests presented in this work. The signatures of decomposition products extracted in this study provide invaluable guidance for developing decomposition-based diagnosis and fixation of decomposition byproducts toward SF6-free power grids.

Physics↗

Deep Analysis Net with Causal Embedding for Coal-fired Power Plant Fault Detection and Diagnosis (DANCE4CFDD)

Fault detection and diagnosis is critical to power plant operation to ensure attaining high reliability while reducing operation cost. As more renewable power is introduced to the power grid, traditional fossil power plants take on the extra burden of excessive load cycling to compensate the generation variability from renewable power. Such load cycling will pose more reliability challenges to power plant operation. There are a number of challenges faced by today’s asset health management system in coal- fired (or gas) power plants: 1) high-dimensional nonlinear interaction among multiple time series measurements; 2) high measurement variance induced by operational conditions/modes; 3) variation among asset types and plant configurations; and 4) a small number of faulty events to learn from. To cope with these challenges, today’s fielded asset health management systems rely heavily on manual efforts from domain experts and hand-crafted features or rules based on domain knowledge. Despite its role in plant reliability, such a practice is costly and hinders its scalability and sustainability, particularly when a plant undergoes modifications. The objective of this project is to develop a novel end-to-end AI learning system that is trainable (i.e., the AI representation of a complex system behavior can be directly learned from properly labeled data) for accurate fault detection and root cause analysis. The ability to create a fault detection model directly from time series could alleviate the efforts associated with today’s asset management solution development. In the course of this project, we have achieved the following: Created an AI model development environment incorporating state-of-the-art neural network architectures for rapid model development and evaluation; Developed novel learning strategies for training of fault detection model; Developed special-purpose neural network architecture embedded with variable association graph aiming for better interpretability; Developed a learning strategy to leverage a small number of faulty events for enhanced fault detection capability; Conducted detailed experimental study based on public benchmark datasets and demonstrated the effectiveness of the proposed solution; and Validated the developed system with data from both a coal-fired plant boiler dynamic simulation model and real-world coal-fired power plant covering multiple asset and fault types. Overall, the project attained a technology readiness level of TRL 5 from TRL 2 at the beginning of the project.

20 FOSSIL-FUELED POWER PLANTS↗

ADMS and DER Coordinated Capability Demonstrations to Assist Utilities to Increase Resilience and Reliability

The proliferation of distributed energy resources (DERs) presents opportunities and challenges to distribution grid operators. The National Renewable Energy Laboratory (NREL) and Survalent are collaborating to demonstrate advanced distribution management system (ADMS) and DER coordinated capability to assist utilities to increase resilience and reliability. ADMS and Distributed Energy Resource Management System (DERMS) Coordination for Peak Load Management (PLM). Fault Location, Isolation, and Service Restoration (FLISR) in the Presence of DERs. Grid-Edge Intelligent Distribution Automation System for Self-Healing Distribution Grids. These laboratory demonstrations use NREL's ADMS Test Bed.

ADMS↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hierarchical Control of Megawatt-Scale Charging Stations for Electric Trucks with Distributed Energy Resources

Electrifying medium- and heavy-duty trucks is critical to decarbonizing the transportation sector. Energy needs of electric trucks will likely require megawatt-scale charging stations, which could significantly stress the electric distribution grid. Distributed energy resources (DER) can alleviate this stress and reduce charging costs with proper management. To that end, this work develops a hierarchical predictive control algorithm for future multi-port megawatt-scale charging stations that can provide real-time energy management for stations, decide charging rates, dispatch energy storage system (ESS), and provide grid voltage support. We integrate three algorithmic components: (i) an energy management optimization (EMO) that provides supervisory control to DER assets and charging loads at minute scale, (ii) a real-time energy management system (RT-EMS) that heuristically compensates for fast disturbances at sub-second scale, and (iii) a model predictive control (MPC)-based battery management system (BMS) that communicates future charging demands to the EMO, to manage the overall megawatt-scale site. Additionally, validation in a controller hardware-in-the-loop (CHIL) environment shows that the hierarchical controller can reduce the total energy consumption from the grid by approximately 28% compared to an uncontrolled case for the station configuration in this paper, without impacting charging time.

24 POWER TRANSMISSION AND DISTRIBUTION↗