Search NASA⌕ Search

SEARCH · Search NASA

Results for “pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Hermetically sealed pump

Mechanically simple, hermetically-sealed pump utilizes pumped fluid for lubrication. The rotor, having helical grooves on the outer surface, functions as both a bearing and pump.

Ludwig, L. P.↗

Large-capacity pump vaporizer for liquid hydrogen and nitrogen

Pump vaporizer system delivers 500 standard cubic feet per minute of hydrogen or nitrogen, one system delivers both gases. Vacuum-jacketed pump discharges liquid hydrogen or liquid nitrogen into vaporizing system heated by ambient air. Principal characteristics of the flow and discharge system, pump, and vaporizer are given.

Hauser, J. A.↗

High pressure liquid gas pump

Design and development of two types of pumps for handling liquefied gases are discussed. One pump uses mechanical valve shift and other uses pneumatic valve shift. Illustrations of pumps are provided and detailed description of operation is included.

Acres, R. L.↗

Response of a radial-bladed centrifugal pump to sinusoidal disturbances for noncavitating flow

A radial-bladed centrifugal pump was run in water with sinusoidal fluctuations of pressure and flow rate imposed at the pump inlet. Since the flow was noncavitating, zero gain was assumed in computing pump impedance. The inertive reactance became greater than the resistance at relatively low frequencies. An electric circuit model was developed in order to explain the trends of inertance and resistance with frequency.

Anderson, D. A.↗

An experimental study of the cryoentrainment pump and the behavior of nude ionization gauge at low temperature

The use of cryopumping techniques to obtain a contamination free vacuum is discussed. Of those gases that are normally present in an initially air filled vacuum system, only carbon dioxide and water vapor will be effectively pumped at 77 degrees Kelvin. In order to circumvent this restriction on the types of gases that are pumped at this temperature, it is postulated that a gas which is easily condensable at 77 degrees K be injected into the system in the form of a directed stream. The stream would then entrain the normally noncondensable species by a momentum transfer mechanism. After sweeping through the volume to be pumped, the injected gas stream would then be condensed on a cryopumping surface maintained at 77 degrees Kelvin.

Daggerhart, J. A.↗

Vehicle-scale investigation of a fluorine jet-pump liquid hydrogen tank pressurization system

A comprehensive analytical and experimental program was performed to evaluate the performance of a fluorine-hydrogen jet-pump injector for main tank injection (MTI) pressurization of a liquid hydrogen (LH2) tank. The injector performance during pressurization and LH2 expulsion was determined by a series of seven tests of a full-scale injector and MTI pressure control system in a 28.3 cu m (1000 cu ft) flight-weight LH2 tank. Although the injector did not effectively jet-pump LH2 continuously, it showed improved pressurization performance compared to straight-pipe injectors tested under the same conditions in a previous program. The MTI computer code was modified to allow performance prediction for the jet-pump injector.

Cady, E. C.↗

Stimulated parametric fluorescence induced by picosecond pump pulses.

Stimulated parametric fluorescence emission tunable over the range from 0.96 to 1.16 microns has been obtained using a barium sodium niobate crystal pumped by a frequency-doubled and mode-locked neodymium:glass laser. The pump radiation in the form of a train of picosecond pulses produced infrared parametric fluorescence pulses, less than 10 psec in duration and with average peak powers on the order of 300 W when pumped with a power density of 300 MW/sq cm.

Rabson, T. A.↗

Study of blade clearance effects on centrifugal pumps

A program of analysis, design, fabrication, and testing has been conducted to develop and experimentally verify analytical models to predict the effects of impeller blade clearance on centrifugal pumps. The effect of tip clearance on pump efficiency, and the relationship between the head coefficient and torque loss with tip clearance was established. Analysis were performed to determine the cost variation in design, manufacture, and test that would occur between unshrouded and shrouded impellers. An impeller, representative of typical rocket engine impellers, was modified by removing its front shroud to permit variation of its blade clearances. It was tested in water with special instrumentation to provide measurements of blade surface pressures during operation. Pump performance data were obtained from tests at various impeller tip clearances. Blade pressure data were obtained at the nominal tip clearance. Comparisons of predicted and measured data are given.

Hoshide, R. K.↗

Space nuclear system thermoelectric NaK pump development

The engineering, design, fabrication, and test history of the dual-throat thermoelectric NaK development pump is summarized, along with the engineering and design status of a similar prototype pump intended for use on the 5-kwe reactor thermoelectric system. The history of dc pump development and testing on previous programs is also summarized.

Johnson, J. L.↗

Space simulation ultimate pressure lowered two decades by removal of diffusion pump oil contaminants during operation

The complex problem why large space simulation chambers do not realize the true ultimate vacuum was investigated. Some contaminating factors affecting diffusion pump performance have been identified and some advances in vacuum/distillation/fractionation technology have been achieved which resulted in a two decade or more lower ultimate pressure. Data are presented to show the overall or individual contaminating effect of commonly used phthalate ester plasticizers of 390 to 530 molecular weight on diffusion pump performance. Methods for removing contaminants from diffusion pump silicone oil during operation and reclaiming contaminated oil by high vacuum molecular distillation are described.

Buggele, A. E.↗

Access to uncombined titanium through an inhibiting film in sublimation pumping of deuterium.

Experimental demonstration of the possibility to gain access to sublayers of uncombined titanium through an inhibiting surface film in titanium bulk sublimator pumping by adding a thin layer of titanium to an apparently occluded surface. Though most of the work described was directed toward more effective utilization of titanium in bulk sublimation pumping for small positive-ion accelerators, the results presented should be of interest to others concerned with hydrogen pumping in general and the problems associated with inhibiting films.

Steinberg, R.↗

Method of investigation of vibroacoustic characteristics of centrifugal pumps

A method for acoustical diagnostics of pumps is described which consists of taking sonograms of the pump, by means of an audio spectrograph. In distinction from usual analyzers, the spectrograph makes it possible to obtain a three-dimensional image of the signal being analyzed, in which its frequency-amplitude characteristics developed over time are depicted with a resolving power of 0.004 sec. As an example, a sonogram of an electrically driven pump, in the 40-4000 Hz frequency range, is presented. The amplitude ratios are determined on the sonogram by the contrast of individual contours, with an accuracy of 6 db.

Pokrovskiy, B. V.↗

Results of TC-1 boost pump icing tests in the space power facility

A series of tests were conducted in the space power facility to investigate the failure of the Centaur oxidizer boost pump during the Titan/Centaur proof flight February 11, 1974. The three basic objectives of the tests were: (1) demonstrate if an evaporative freezing type failure mechanism could have prevented the pump from operating, (2) determine if steam from the exhaust of one of the attitude control engine could have entered a pump seal cavity and caused the failure, and (3) obtain data on the heating effects of the exhaust plume from a hydrogen peroxide attitude control engine.

Gentile, L. C.↗

Centaur liquid oxygen boost pump vibration test

The Centaur LOX boost pump was subjected to both the simulated Titan Centaur proof flight and confidence demonstration vibration test levels. For each test level, both sinusoidal and random vibration tests were conducted along each of the three orthogonal axes of the pump and turbine assembly. In addition to these tests, low frequency longitudinal vibration tests for both levels were conducted. All tests were successfully completed without damage to the boost pump.

Tang, H. M.↗

Elementary theory of synchronous arterio-arterial blood pumps

In the technique of arterio-arterial pumping, a volume of fluid is withdrawn from the aorta during systole and reinjected during diastole, thereby reducing the systolic pressure of the heart and adding energy to the systemic circulation. It is found that an upper bound for the effectiveness of such devices is given by a formula that considers stroke output of the unaided heart and the increment caused by the pump with a stroke. The division of effort of the pump between the reduction of pressure and the increase of flow depends on the physiological mechanical impedance of the heart. The total effect is, however, independent of the impedance.

Jones, R. T.↗

Centaur boost pump turbine icing investigation

An investigation was conducted to determine if ice formation in the Centaur vehicle liquid oxygen boost pump turbine could prevent rotation of the pump and whether or not this phenomenon could have been the failure mechanism for the Titan/Centaur vehicle TC-1. The investigation consisted of a series of tests done in the LeRC Space Power Chamber Facility to evaluate evaporative cooling behavior patterns in a turbine as a function of the quantity of water trapped in the turbine and as a function of the vehicle ascent pressure profile. It was found that evaporative freezing of water in the turbine housing, due to rapid depressurization within the turbine during vehicle ascent, could result in the formation of ice that would block the turbine and prevent rotation of the boost pump. But for such icing conditions to exist it would be necessary to have significant quantities of water in the turbine and/or its components, and the turbine housing temperature would have to be colder than 40 F at vehicle liftoff.

Rollbuhler, R. J.↗

Axial-flow pump blade-element loss and deviation angle prediction

Determination of blade row fluid flow total-pressure loss and turning distributions in an axial-flow pump over a range of operating conditions is discussed. Included are a review of related research, correlations of pump rotor data and the results obtained using these data correlations with a computer program for pump off-design performance prediction. A number of the important problems related to determining fluid loss and turning information in a turbomachine and some of the consequences of imprecise prediction are pointed out.

Okiishi, T. H.↗

Two pumps reduce maser weight

Weight and cost of conventional hydrogen maser is reduced significantly by replacing large ion pump with hydrogen sorption pump and miniature ion pump for scavenging hydrogen and residual gases.

Source record↗