Search NASA⌕ Search

SEARCH · Search NASA

Results for “pump systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Integrating Survival Analysis with Bayesian Statistics to Forecast the Remaining Useful Life of a Centrifugal Pump Conditional to Multiple Fault Types

To improve the viability of nuclear power plants, there is a need to reduce their operational costs. Operational costs account for a significant portion of a plant’s yearly budget, due to their scheduled-based maintenance approach. In order to reduce these costs, proactive methods are required that estimate and forecast the state of a machine in real time to optimize maintenance schedules. In this research, we use Bayesian networks to develop a framework that can forecast the remaining useful life of a centrifugal pump. To do so, we integrate survival analysis with Bayesian statistics to forecast the health of the pump conditional to its current state. We complete our research by successfully using the Bayesian network on a case study. This solution provides an informed probabilistic viewpoint of the pumping system for the purpose of predictive maintenance.

42 ENGINEERING↗

A High-Magnetic-Field Polarized 3He Target for Jefferson Lab’s CLAS12 Spectrometer

We are developing a polarized 3He target concept for use in high luminosity electron scattering experiments in the high magnetic field environment of Jefferson Lab's CLAS12 spectrometer. By combining recent advancements in metastability exchange optical pumping of 3He with cryogenic, double-cell target methods such as those used for the MIT-Bates 88-02 experiment, a target with polarization and gas density comparable to traditional, low-field polarized 3He targets can be reached within high magnetic fields. We have established a new 3He pumping system at JLab, and are preparing for our first tests exploring polarization performance versus magnetic field and gas pressure in a single cell before we move to the construction of a full, cryogenic, double-cell prototype target.

Maxwell, James↗

Antechamber facilitates loading and unloading of vacuum furnace

Antechamber facilitates the use of a furnace in which materials are heat treated in a high vacuum or a gas atmosphere. It has a high vacuum pumping system, a means for backfilling with a selected gas, an access door, glove ports, and a motor driven platform.

Kramer, P. J.↗

Research and investigation of gas dynamic lasers

Chemical mixing laser investigations were conducted (1) to investigate the properties of a bimolecular exchange laser system pumped by the H + Cl2 yields HCl(v) + Cl reaction, initiated by arc-dissociated H2, with lasing occurring between wavelengths of 3.4 and 4.0 microns, and (2) to establish the feasibility of an atom recombination-transfer laser employing recombination of arc-dissociated nitrogen with subsequent transfer of vibrational energy to CO2 for lasing at 10.6 microns. One-dimensional analytical results indicate higher results should be obtained with up to v = 3 to 2 transitions participating. Diagnostic and analytical results show that the reaction mechanism during mixing, a back reaction of HCl(v) with H atoms, reaction of Cl with H2(v), moderately fast V-V, V-T processes, and possible HCl(o) initial contaminant level may explain the low performance. N2-CO2 thermal mixing laser studies were extended to measure the efficiency of transfer of recombination energy in such a nonequilibrium N2 source to 10.6 microns optical energy. The low level of efficiency suggests that V-T decay processes may prevent vibrational energy freezing until much lower temperatures are achieved and that trapping of energy in long-lived electronic excitation of N2 may be a factor.

Boedeker, L. R.↗

Piston manometer as an absolute standard for vacuum gage calibration in the range 10 to 700 microtorr

Total pressure in a calibration chamber is determined by measuring the force on a disk suspended in an orifice in the baseplate of the chamber. The disk forms a narrow annular gap with the orifice. A continuous flow of calibration gas passes through the chamber and annulus to a downstream pumping system. The ratio of pressures on the two faces of the disk exceeds 100:1, so that chamber pressure is substantially equal to the product of disk area and net force on the disk. This force is measured with an electrodynamometer that can be calibrated in situ with dead weights. Probable error in pressure measurement is plus or minus (0.5 microtorr + 0.6 percent).

Warshawsky, I.↗

KSC lubricant testing program

A program was conducted to evaluate the performance of various lubricants in use and considered for use at Kennedy Space Center (KSC). The overall objectives of the program were to: (1) determine the lubrication characteristics and relative corrosion resistance of lubricants in use and proposed for use at KSC; (2) identify materials which may be equivalent to or better than KELF-90 and Krytox 240 AC greases; and (3) identify or develop an improved lubricating oil suitable for use in liquid oxygen (LOX) pumps at KSC. It was concluded that: (1) earth gel thickened greases are very poor corrosion preventive materials in the KSC environment; (2) Halocarbon 25-5S and Braycote 656 were suitable substiutes for KELF-90 and Krytox 240 AC respectively; and (3) none of the oils evaluated possessed the necessary inertness, lubricity, and corrosion prevention characteristics for the KSC LOX pumping systems in their present configuration.

Lockhart, B. J.↗

Refractive index of He in the region 920-1910 A

The refractive index of He has been determined in the region 920-1910 A by measurements of wavelength shifts in a 3-m spectrograph alternately filled with He and evacuated. Differential pumping systems were used to allow operation of the light source at conveniently low pressures. Several plates were measured and analyzed in order to reduce statistical errors. The results at 919 A agree with the theory within 1%, i.e., less than the experimental error.

Huber, M. C. E.↗

Program to design, fabricate, test, and deliver a thermal control-mixing control device, phase 1

The development of a sensor capable of detecting temperature changes as a function of viscosity changes, was completed. This type of sensor, consisting of an orifice bridge circuit, resulted in a device with a threshold above internally generated noise of 0.8C (1.5F). Data were obtained using a noise free Freon source provided by an air pressurized bladder. Tests conducted to operate the sensor from a typical Freon centrifugal pump system employing an air bubble accumulator for noise attentuation disclosed the sensor could be used only to sense temperature changes greater than 3.3C (6F) because of the excessively noisy output. This is attributed to the high frequency-pressure fluctuations in the Freon supply to the sensor.

Thurston, T. S.↗

Exploratory laser experiments

Experiments are described which were undertaken to explore the application of various dye laser methods for generating laser pulses which could be tuned over H2O absorption lines in the visible and near infrared. Specific topics discussed include: operation of a long pulse dye laser with a tunable, narrow band output at high energies near the 5915 A water vapor absorption bands; assembly and operation of a short duration dye laser near the 5915 A water vapor absorption bands; construction of a dye laser to be pumped to operate in the red and near infrared; and preliminary studies of the beam divergence of the output of the a laser-pumped system. Results are summarized.

Source record↗

Industrial ion source technology

Plasma probe surveys were conducted in a 30-cm source to verify that the uniformity in the ion beam is the result of a corresponding uniformity in the discharge-chamber plasma. A 15 cm permanent magnet multipole ion source was designed, fabricated, and demonstrated. Procedures were investigated for texturing a variety of seed and surface materials for controlling secondary electron emission, increasing electron absorption of light, and improved attachment of biological tissue for medical implants using argon and tetrafluoromethane as the working gases. The cross section for argon-argon elastic collisions in the ion-beam energy range was calculated from interaction potentials and permits calculation of beam interaction effects that can determine system pumping requirements. The data also indicate that different optimizations of ion-beam machines will be advantageous for long and short runs, with 1 mA-hr/cm being the rough dividing line for run length. The capacity to simultaneously optimize components in an ion-beam machine for a single application, a capacity that is not evident in competitive approaches such as diode sputtering is emphasized.

Kaufman, H. R.↗

Instrument for aerosol characterization

Differential pumping system that directs particles into beam moving at high speed measures size distribution and chemical composition of aerosols and is useful in study of atmospheric contamination, smog, stack gases, and chemical aerosols.

Varsi, G.↗

The Addition of EI/CI Capability to the Mattauch-herzog Spectrograph with EOID

A modification was made to the Mattauch-Herzog Spectrograph with an electro-optical ion detector (EOID) previously designed and constructed, so that it would be capable of operating not only in the electron-impact (EI) mode of ionization, but also in the chemical ionization (CI) mode. This modification necessitated an effort in three specific design areas: (1) sample inlet; (2) ion source and analyzer regions; and (3) the pumping system. In addition, an appropriate electronics package had to be designed to control and operate the combined EI/CI source.

Fergusson, G. J.↗

Low background focal plane array testing in the far infrared

A new long-wavelength infrared test facility is being developed to conduct proof-of-performance tests of focal plane arrays for the Infrared Astronomical Satellite (IRAS) telescope. This facility is believed to be unique in that it will calibrate full-sized arrays designed for the 5-120-micron region of the IR spectrum under simulated spaceflight conditions and at background levels as low as 8 million photons/sq cm-sec. Most of the tests will be performed in a main test chamber which contains a liquid helium shroud, blackbody sources, an arrangement to simulate zodiacal background, and spot scanning optics. A noncontaminating high-vacuum pumping system will be used to evacuate the chamber prior to cool-down to prevent molecular deposition. All housekeeping and focal plane signal outputs are multiplexed, digitized, and transmitted on high-speed data lines to a PDP-11/70 computer. The computer provides real-time displays on a color CRT terminal and stores data for subsequent reduction and hard copy output. An overview of the conceptual design and performance specifications of the test facility are given.

Iufer, E. J.↗

A precoat prevents ceramic stopoffs from spalling

Nickel-alloy precoat applied with plasmagun improves adhesion of ceramic materials applied to protect areas from unintentional brazing. Metal surface should be grit-blasted before precoating. Coating does not interfere with brazing or contaminate vacuum pumping systems.

Brennan, A.↗