Measurements of the counting statistics of Image Plate TR for quantitative x-ray spectroscopy of high temperature plasmas.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
A substantial body of literature exists to study the dynamics of single cells exposed to short duration (<1 μs), high peak power (~1 MV/m) transient electric fields. Much of this research is limited to traditional fluorescence-based microscopy techniques, which introduce exogenous agents to the culture and are only sensitive to a single molecular target. Quantitative phase imaging (QPI) is a coherent imaging modality which uses optical path length as a label-free contrast mechanism, and has proven highly effective for the study of single-cell dynamics. In this work, we introduce QPI as a useful imaging tool for the study of cells undergoing cytoskeletal remodeling after nanosecond pulsed electric field (nsPEF) exposure. In particular, we use cell swelling, dry mass and disorder strength measurements derived from QPI phase images to monitor the cellular response to nsPEFs. We hope this demonstration of QPI's utility will lead to a further adoption of the technique for the study
We present the methods adopted to optimize the calibration of images obtained with the Hubble Space Telescope (HST) Wide Field Camera (WFC) (1991-1993). Our main goal is to improve quantitative measurement of faint images, with special emphasis on the faint (I approximately 20-24 mag) stars and galaxies observed as a part of the Medium-Deep Survey. Several modifications to the standard calibration procedures have been introduced, including improved bias and dark images, and a new supersky flatfield obtained by combining a large number of relatively object-free Medium-Deep Survey exposures of random fields. The supersky flat has a pixel-to-pixel rms error of about 2.0% in F555W and of 2.4% in F785LP; large-scale variations are smaller than 1% rms. Overall, our modifications improve the quality of faint images with respect to the standard calibration by about a factor of five in photometric accuracy and about 0.3 mag in sensitivity, corresponding to about a factor of two in observing time. The relevant calibration images have been made available to the scientific community.
The purpose of this study was to develop a novel statistics-based method for automated detection of anatomical changes using cone-beam CT (CBCT) images of head and neck (H and N) patients. Vendor supplied CBCT software provides the user with the basic tools that allow for the visual assessment of the co-registration of the reference CT data and daily CBCT images. Currently there is no commercially available CBCT software that is capable of detecting anatomical changes and giving the clinician an early alert for the treatment plan adaptation. An algorithm was developed that can detect statistically significant changes at a given confidence level for H and N patients. This tool provides a reliable and automated early warning system that enables a 'just-in-time' adaptation of the treatment plan. A method was developed for automated detection of anatomical changes in H and N patients under radiation therapy treatment. The method utilized imaging CT data along with daily CBCT images to quantitatively compare the patient anatomy against the reference CT imaging data. The comparison algorithm was developed using a statistics-based approach as opposed to threshold-based methods. The algorithm allows for reliable detection of statistically significant changes in the observed patient anatomy at a given level of confidence. The method can be employed as an integral part of the adaptive radiotherapy framework. (authors)
The 2018 NRC HEAF tests were conducted in Chalfont Pennsylvania at KEMA High Power Laboratory during the week of September 10th. These scoping tests were executed to determine the most effective measurement methodologies for future tests. The goal of Sandia’s Photometrics group was to provide high-speed quantitative and qualitative imaging of the arcing fault tests for the Nuclear Regulatory Commission. The measurement methods included visible high-speed imaging, high-speed high-dynamic range visible imaging, thermal imaging, and quantitative flow imaging. In addition, data fusion products were generated to visualize instrumentation data and imaging measurements. All imaging has been time synchronized to the start of the arcing event.
Purpose: To identify prognostic biomarkers in pancreatic cancer using high-throughput quantitative image analysis. Methods and Materials: In this institutional review board–approved study, we retrospectively analyzed images and outcomes for 139 locally advanced pancreatic cancer patients treated with stereotactic body radiation therapy (SBRT). The overall population was split into a training cohort (n=90) and a validation cohort (n=49) according to the time of treatment. We extracted quantitative imaging characteristics from pre-SBRT {sup 18}F-fluorodeoxyglucose positron emission tomography, including statistical, morphologic, and texture features. A Cox proportional hazard regression model was built to predict overall survival (OS) in the training cohort using 162 robust image features. To avoid over-fitting, we applied the elastic net to obtain a sparse set of image features, whose linear combination constitutes a prognostic imaging signature. Univariate and multivariate Cox regression analyses were used to evaluate the association with OS, and concordance index (CI) was used to evaluate the survival prediction accuracy. Results: The prognostic imaging signature included 7 features characterizing different tumor phenotypes, including shape, intensity, and texture. On the validation cohort, univariate analysis showed that this prognostic signature was significantly associated with OS (P=.002, hazard ratio 2.74), which improved upon conventional imaging predictors including tumor volume, maximum standardized uptake value, and total legion glycolysis (P=.018-.028, hazard ratio 1.51-1.57). On multivariate analysis, the proposed signature was the only significant prognostic index (P=.037, hazard ratio 3.72) when adjusted for conventional imaging and clinical factors (P=.123-.870, hazard ratio 0.53-1.30). In terms of CI, the proposed signature scored 0.66 and was significantly better than competing prognostic indices (CI 0.48-0.64, Wilcoxon rank sum test P<1e-6). Conclusion: Quantitative analysis identified novel {sup 18}F-fluorodeoxyglucose positron emission tomography image features that showed improved prognostic value over conventional imaging metrics. If validated in large, prospective cohorts, the new prognostic signature might be used to identify patients for individualized risk-adaptive therapy.
The Grant was a three year grant funded under the Space Physics Supporting Research and Technology and Suborbital Program. Our objective was to develop automated techniques needed to unfold or "invert" global images of the magnetospheric ion populations obtained by the new magnetospheric imaging techniques (ENA, EUV) in anticipation of future missions such as the Magnetospheric Imager and, now, IMAGE. Our focus on the present three year grant is to determine the degree to which such images can quantitatively constrain the global electromagnetic properties of the magnetosphere. In a previous three year grant period we successfully automated a forward modeling inversion algorithm, demonstrated that these inversions are robust in the face of realistic instrumental considerations such as counting statistics and backgrounds, applied error analysis techniques to the extracted parameters using variational procedures, implemented very realistic magnetospheric test images to test the inversion algorithms using the Rice University Magnetospheric Specification Model, and began the process of generating parametric models with the flexibility to handle the realistic magnetospheric images (e.g. Roelof et al, 1992; 1993). Our plan for the present 3 year grant period was to complete the development of the inversion tools needed to handle realistic magnetospheric images, assess the degree to which global electrodynamics is quantitatively constrained by ENA images of the magnetosphere, and bring the inversion of EUV images up to the maturity that we will have achieved for the ENA imaging. Below the accomplishments of our three year effort are present followed by a list of our presentations and publications. The accomplishments of all three years are presented here, and thus some of these items appeared on interim progress reports.
Purpose: Partial volume effect (PVE) plays an important role in both qualitative and quantitative PET image accuracy, especially for small structures. A previously proposed voxelwise PVE correction method applied on PET reconstructed images involves the use of Lucy–Richardson deconvolution incorporating wavelet-based denoising to limit the associated propagation of noise. The aim of this study is to incorporate the deconvolution, coupled with the denoising step, directly inside the iterative reconstruction process to further improve PVE correction. Methods: The list-mode ordered subset expectation maximization (OSEM) algorithm has been modified accordingly with the application of the Lucy–Richardson deconvolution algorithm to the current estimation of the image, at each reconstruction iteration. Acquisitions of the NEMA NU2-2001 IQ phantom were performed on a GE DRX PET/CT system to study the impact of incorporating the deconvolution inside the reconstruction [with and without the point spread function (PSF) model] in comparison to its application postreconstruction and to standard iterative reconstruction incorporating the PSF model. The impact of the denoising step was also evaluated. Images were semiquantitatively assessed by studying the trade-off between the intensity recovery and the noise level in the background estimated as relative standard deviation. Qualitative assessments of the developed methods were additionally performed on clinical cases. Results: Incorporating the deconvolution without denoising within the reconstruction achieved superior intensity recovery in comparison to both standard OSEM reconstruction integrating a PSF model and application of the deconvolution algorithm in a postreconstruction process. The addition of the denoising step permitted to limit the SNR degradation while preserving the intensity recovery. Conclusions: This study demonstrates the feasibility of incorporating the Lucy–Richardson deconvolution associated with a wavelet-based denoising in the reconstruction process to better correct for PVE. Future work includes further evaluations of the proposed method on clinical datasets and the use of improved PSF models.
We have produced images that quantitatively depict modal and chemical parameters of granitoids using an image processing algorithm called MINMAP that fits Gaussian curves to normalized emittance spectra recovered from thermal infrared multispectral scanner (TIMS) radiance data. We applied the algorithm to TIMS data from the Desolation Wilderness, an extensively glaciated area near the northern end of the Sierra Nevada batholith that is underlain by Jurassic and Cretaceous plutons that range from diorite and anorthosite to leucogranite. The wavelength corresponding to the calculated emittance minimum lambda(sub min) varies linearly with quartz content, SiO2, and other modal and chemical parameters. Thematic maps of quartz and silica content derived from lambda(sub min) values distinguish bodies of diorite from surrounding granite, identify outcrops of anorthosite, and separate felsic, intermediate, and mafic rocks.
Purpose: With the advent of digital slide scanning technologies and the potential proliferation of large repositories of digital pathology images, many research studies can leverage these data for biomedical discovery and to develop clinical applications. However, quantitative analysis of digital pathology images is impeded by batch effects generated by varied staining protocols and staining conditions of pathological slides. Methods: To overcome this problem, this paper proposes a novel, fully automated stain normalization method to reduce batch effects and thus aid research in digital pathology applications. Their method, intensity centering and histogram equalization (ICHE), normalizes a diverse set of pathology images by first scaling the centroids of the intensity histograms to a common point and then applying a modified version of contrast-limited adaptive histogram equalization. Normalization was performed on two datasets of digitized hematoxylin and eosin (H&E) slides of different tissue slices from the same lung tumor, and one immunohistochemistry dataset of digitized slides created by restaining one of the H&E datasets. Results: The ICHE method was evaluated based on image intensity values, quantitative features, and the effect on downstream applications, such as a computer aided diagnosis. For comparison, three methods from the literature were reimplemented and evaluated using the same criteria. The authors found that ICHE not only improved performance compared with un-normalized images, but in most cases showed improvement compared with previous methods for correcting batch effects in the literature. Conclusions: ICHE may be a useful preprocessing step a digital pathology image processing pipeline.
This paper presents results from an investigation of soot formation in turbulent, non-premixed, C{sub 2}H{sub 4}/air jet flames. Tests were conducted using a H{sub 2}-piloted burner with fuel issuing from a 2.18 mm i.d. tube into quiescent ambient air. A range of test conditions was studied using the initial jet velocity (16.2-94.1 m/s) as a parameter. Fuel-jet Reynolds numbers ranged from 4000 to 23,200. Planar laser-induced incandescence (LII) was employed to determine soot volume fractions, and laser-induced fluorescence (LIF) was used to measure relative hydroxyl radical (OH) concentrations and polycyclic aromatic hydrocarbons (PAHs) concentrations. Extensive information on the structure of the soot and OH fields was obtained from two-dimensional imaging experiments. Quantitative measurements were obtained by employing the LII and LIF techniques independently. Imaging results for soot, OH, and PAH show the existence of three soot formation/oxidation regions: a rapid soot growth region, in which OH and soot particles lie in distinctly different radial locations; a mixing-dominated region controlled by large-scale motion; and a soot-oxidation region in which the OH and soot fields overlap spatially, resulting in the rapid oxidation of soot particles. Detailed quantitative analyzes of soot volume fractions and OH and soot zone thicknesses were performed along with the temperature measurement using the N{sub 2}-CARS system. Measurements of OH and soot zone thicknesses show that the soot zone thickness increases linearly with axial distance in the soot formation region, whereas the OH zone thickness is nearly constant in this region. The OH zone thickness then rapidly increases with downstream distance and approximately doubles in the soot-oxidation region. Probability density functions also were obtained for soot volume fractions and OH concentrations. These probability density functions clearly define the spatial relationships among the OH, PAH concentrations, the soot formation, and oxidation processes. (author)
Purpose: To review the literature in using quantitative PET and CT image features for the evaluation of tumor response. Methods: We reviewed and summarized more than fifty papers that use advanced, quantitative PET/CT image features for the evaluation of tumor response. We also discussed future works on extracting disease-specific features, combining multiple and complementary features in response modeling, delineating tumor in multimodality images, and exploring biological explanations of these advanced features. Results: Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features (characterizing spatial distribution of FDG uptake) have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Conclusions: Advanced, quantitative FDG PET/CT image features have been shown promising for the evaluation of tumor response. With the emerging multi-modality imaging performed at multiple time points for each patient, it becomes more important to analyze the serial images quantitatively, select and combine both complementary and contradictory information from various sources, for accurate and personalized evaluation of tumor response to therapy.
Purpose: Several positron emission tomography (PET) scanners with special detector block arrangements have been developed in recent years to improve the resolution of PET images. However, the discontinuous detector blocks cause gaps in the sinogram. This study proposes an adaptive discrete cosine transform-based (aDCT) filter for gap-inpainting. Methods: The gap-corrupted sinogram was morphologically closed and subsequently converted to the DCT domain. A certain number of the largest coefficients in the DCT spectrum were identified to determine the low-frequency preservation region. The weighting factors for the remaining coefficients were determined by an exponential weighting function. The aDCT filter was constructed and applied to two digital phantoms and a simulated phantom introduced with various levels of noise. Results: For the Shepp-Logan head phantom, the aDCT filter filled the gaps effectively. For the Jaszczak phantom, no secondary artifacts were induced after aDCT filtering. The percent mean square error and mean structure similarity of the aDCT filter were superior to those of the DCT2 filter at all noise levels. For the simulated striatal dopamine innervation study, the aDCT filter recovered the shape of the striatum and restored the striatum to reference activity ratios to the ideal value. Conclusions: The proposed aDCT filter can recover the missing gap data in the sinogram and improve the image quality and quantitative accuracy of PET images.
Purpose: The purpose of the present study was to quantify, evaluate the impact of cardiac and respiratory motion on clinical nuclear imaging protocols. Common SPECT and scintigraphic scans are studied using Monte Carlo (MC) simulations, comparing the resulted images with and without motion. Methods: Realistic simulations were executed using the GATE toolkit and the XCAT anthropomorphic phantom as a reference model for human anatomy. Three different radiopharmaceuticals based on 99mTc were studied, namely 99mTc-MDP, 99mTc—N—DBODC and 99mTc—DTPA-aerosol for bone, myocardium and lung scanning respectively. The resolution of the phantom was set to 3.5 mm{sup 3}. The impact of the motion on spatial resolution was quantified using a sphere with 3.5 mm diameter and 10 separate time frames, in the ECAM modeled SPECT scanner. Finally, respiratory motion impact on resolution and imaging of lung lesions was investigated. The MLEM algorithm was used for data reconstruction, while the literature derived biodistributions of the pharmaceuticals were used as activity maps in the simulations. Results: FWHM was extracted for a static and a moving sphere which was ∼23 cm away from the entrance of the SPECT head. The difference in the FWHM was 20% between the two simulations. Profiles in thorax were compared in the case of bone scintigraphy, showing displacement and blurring of the bones when respiratory motion was inserted in the simulation. Large discrepancies were noticed in the case of myocardium imaging when cardiac motion was incorporated during the SPECT acquisition. Finally the borders of the lungs are blurred when respiratory motion is included resulting to a dislocation of ∼2.5 cm. Conclusion: As we move to individualized imaging and therapy procedures, quantitative and qualitative imaging is of high importance in nuclear diagnosis. MC simulations combined with anthropomorphic digital phantoms can provide an accurate tool for applications like motion correction techniques’ optimization. This research has been co-funded by the European Union (European Social Fund) and Greek national resources under the framework of the ‘Archimedes III: Funding of Research Groups in TEI of Athens’ project of the ‘Education & Lifelong Learning’ Operational Programme.