Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometer calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

On-Orbit Calibration and Performance of NOAA-20 VIIRS Reflective Solar Bands

The NOAA-20 (N20) satellite was launched on November 18, 2017 carrying the second Visible Infrared Imaging Radiometer Suite (VIIRS) instrument. Immediately following the launch, the VIIRS passed a series of intensive calibration and validation tests, after which regular calibration and operation activities have continued successfully for more than three years. The production of NASA Collection 2 Level 1B (C2 L1B) for N20 VIIRS began in summer 2019. In this article, we evaluate the early mission performance of the N20 VIIRS reflective solar bands (RSB) covering the first three full years of operation. The calibrated RSB gains are calculated primarily from the onboard solar diffuser (SD) and used in generating the C2 L1B reflectance and radiance products. We also show the on-orbit performance of the instrument noise, signal-to-noise ratio (SNR), and a reflectance uncertainty assessment. Comparisons are made to the first three years of operation of the first VIIRS instrument, aboard the Suomi National Polar-orbiting Partnership (SNPP) satellite. We evaluate the long-term stability of the calibrated N20 RSB reflectance product by looking at the long-term trends of lunar observations and data from the pseudo-invariant Libya 4 desert site. The N20 RSB have had excellent early mission performance, with changes in the gain of less than 0.5% in the first three years across all detectors, stable L1B reflectance, and very stable values of detector SNR and reflectance uncertainty.

calibration↗

Early Calibration and Performance Assessments of NOAA-20 VIIRS Thermal Emissive Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the NOAA-20 (previously JPSS-1) spacecraft has successfully operated since its launch in November, 2017. Similar to the first VIIRS instrument on the Suomi-NPP spacecraft, data is collected in 22 spectral bands that are calibrated by a set of onboard calibrators. This paper provides an overview of the NOAA-20 VIIRS on-orbit operation and calibration, with a particular focus on the thermal emissive bands (TEBs). Results presented in this paper include the on-orbit changes in the TEB spectral band responses, detector noise characterization, and key calibration parameters, such as the non-linear coefficients derived from the blackbody warm-up cool-down cycle. Other issues, such as the early mission long-wave infrared (LWIR) response degradation due to icing on the dewar window, and their impact on sensor calibration are also discussed. Since launch, the VIIRS instrument temperature has been stable to within ± 0.8K and the cold focal plane temperatures are well controlled with variations less than 40 mK. With the exception of the early degradation observed in the LWIR bands, the TEB gains have been stable to within 0.04% (except I5 at 0.07%). Based on the current performance, VIIRS is expected to meet its calibration requirements throughout its design lifetime.

NEdT↗

Calibration standards and field instruments for the precision measurement of insolation

The paper describes the development of an absolute calibration standard for irradiance measurements. This field instrument, designated the Kendall Radiometer System Mark 3, is identical to the PACRAD (Primary Absolute Cavity Radiometer) except for a modification to ensure all weather operation. Two Mark 3 radiometers have been in operation at the JPL's Goldstone Deep Space Communications Complex for over two years and are continuing to provide data which are within plus or minus 1% of the absolute value. A calibration stability analysis is presented for the two instruments.

Reid, M. S.↗

Normalization and calibration of geostationary satellite radiances for the International Satellite Cloud Climatology Project

Procedures are described for normalizing the radiometric calibration of image radiances obtained from geostationary weather satellites that contributed data to the International Satellite Cloud Climatology Project. The key step is comparison of coincident and collocated measurements made by each satellite and the concurrent AVHRR on the 'afternoon' NOAA polar-orbiting weather satellite at the same viewing geometry. The results of this comparison allow transfer of the AVHRR absolute calibration, which has been established over the whole series, to the radiometers on the geostationary satellites. Results are given for Meteosat-2, 3, and 4, for GOES-5, 6, and 7, for GMS-2, 3, and 4 and for Insat-1B. The relative stability of the calibrations of these radiance data is estimated to be within +/- 3 percent; the uncertainty of the absolute calibrations is estimated to be less than 10 percent. The remaining uncertainties are at least two times smaller than for the original radiance data.

Desormeaux, Yves↗

AMPR CAMP2Ex Calibrated and Quality-Controlled Dataset Level 2B, Revision B

Data were acquired by the Advanced Microwave Precipitation Radiometer (AMPR) during the Cloud, Aerosol and Monsoon Processes Philippines Experiment (CAMP2Ex) field campaign in August-October of 2019. These files include the Level 2B calibrated, corrected, and geo-referenced brightness temperature for the four AMPR-observed frequencies (10, 19, 37, 85 GHz). These data are archived in a self-describing, Climate and Forecasting (CF) 1.6-compliant Version 4 Network Common Data Format (netCDF4) format.Python software has been developed for reading, plotting, and providing some additional analysis capabilities. This software is available from: https://github.com/nasa/pyampr.The AMPR instrument is explained in more detail here: https://weather.msfc.nasa.gov/ampr/.These data have been determined to be viable for publishable scientific research, and alsoshould be useful for generating quicklooks or understanding what happened during a flight. Note: AMPRis not expected to provide useful data during significant aircraft maneuvers

Timothy Lang↗

Assessment of SNPP VIIRS VIS NIR Radiometric Calibration Stability Using Aqua MODIS and Invariant Surface Targets

The first Visible Infrared Imaging Radiometer Suite (VIIRS) is onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite. As a primary sensor, it collects imagery and radiometric measurements of the land, atmosphere, cryosphere, and oceans in the spectral regions from visible (VIS) to long-wave infrared. NASA's National Polar-orbiting Partnership (NPP) VIIRS Characterization Support Team has been actively involved in the VIIRS radiometric and geometric calibration to support its Science Team Principal Investigators for their independent quality assessment of VIIRS Environmental Data Records. This paper presents the performance assessment of the radiometric calibration stability of the VIIRS VIS and NIR spectral bands using measurements from SNPP VIIRS and Aqua MODIS simultaneous nadir overpasses and over the invariant surface targets at the Libya-4 desert and Antarctic Dome Concordia snow sites. The VIIRS sensor data records (SDRs) used in this paper are reprocessed by the NASA SNPP Land Product Evaluation and Analysis Tool Element. This paper shows that the reprocessed VIIRS SDRs have been consistently calibrated from the beginning of the mission, and the calibration stability is similar to or better than MODIS. Results from different approaches indicate that the calibrations of the VIIRS VIS and NIR spectral bands are maintained to be stable to within 1% over the first three-year mission. The absolute calibration differences between VIIRS and MODIS are within 2%, with an exception for the 0.865-m band, after correction of their spectral response differences.

Wu, Aisheng↗

Calibration of Passive Microwave Hybrid Coupler-based Polarimeters

Passive microwave polarimeters, or polarimetric radiometers, are important tools for Earth remote sensing. They have found utility in ocean surface wind-vector remote sensing and polarization basis rotation systems for compensating instrument or ionospheric induced rotation. The hybrid coupler-based polarimeter is a specific class of polarimeter that utilizes a 180-degree hybrid coupler to affect a correlation between the received vertical and horizontal polarization signals. This type of polarimeter requires at least four calibration states for complete calibration. One state must be a polarized signal, such as the application of a correlated noise source. The phase balance of the noise source directly determines the quality of the calibration.

Piepmeier, J. R.↗

Deep Space Network Radiometric Remote Sensing Program

Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid, and precipitation, emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band because communication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of water vapor-induced propagation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity wave experiments, and radio science missions. During 1993, WVRs provided data for propagation model development, supported planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily, monthly, and seasonal variations. Only long-term monitoring will prevent biases from being introduced by an exceptionally wet or dry year. Support for planetary missions included tropospheric calibration for the recent Mars Observer gravity wave experiments and Ka-band link experiment (KaBLE). Additionally, several proposed radio science experiments such as profiling planetary atmospheres using satellite occultations and Ka-band gravitational wave searches require advanced radiometer technology development. Finally, there has been a consistent advanced technology program to advance satellite navigational and tracking capabilities. This year that included an experiment with radiometer based tropospheric calibration for a series of VLBI catalog measurements.

tropospheric calibration atmospheric water radio s↗

(abstract) Deep Space Network Radiometric Remote Sensing Program

Planetary spacecraft are viewed through a troposphere that absorbs and delays radio signals propagating through it. Tropospheric water, in the form of vapor, cloud liquid,and precipitation , emits radio noise which limits satellite telemetry communication link performance. Even at X-band, rain storms have severely affected several satellite experiments including a planetary encounter. The problem will worsen with DSN implementation of Ka-band becausecommunication link budgets will be dominated by tropospheric conditions. Troposphere-induced propagation delays currently limit VLBI accuracy and are significant sources of error for Doppler tracking. Additionally, the success of radio science programs such as satellite gravity wave experiments and atmospheric occultation experiments depends on minimizing the effect of watervapor-induced prop agation delays. In order to overcome limitations imposed by the troposphere, the Deep Space Network has supported a program of radiometric remote sensing. Currently, water vapor radiometers (WVRs) and microwave temperature profilers (MTPs) support many aspects of the Deep Space Network operations and research and development programs. Their capability to sense atmospheric water, microwave sky brightness, and atmospheric temperature is critical to development of Ka-band telemetry systems, communication link models, VLBI, satellite gravity waveexperiments, and r adio science missions. During 1993, WVRs provided data for propagation mode development, supp orted planetary missions, and demonstrated advanced tracking capability. Collection of atmospheric statistics is necessary to model and predict performance of Ka-band telemetry links, antenna arrays, and radio science experiments. Since the spectrum of weather variations has power at very long time scales, atmospheric measurements have been requested for periods ranging from one year to a decade at each DSN site. The resulting database would provide reliable statistics on daily, monthly, and seasonal variations. Only long-term monitoring will prevent biases from being introduced by an exceptionally wet or dry year. Support for planetary missions included tropospheric calibration for the recent Mars Observer gravity wave experiments and Ka-band link experiment (KaBLE). Additionally, several proposed radio science experiments such as profiling planetary atmospheres using satellite occultations and Ka-band gravitational wave searches require advanced radiometer technology development. Finally, there has been a consistent advanced technology program to advance satellite navigational and tracking capabilities. This year that included an experiment with radiometer based tropospheric calibration for a series of VLBI catalog measurements.

microwave propagation Ka-band weather variations r↗

Monitoring the Calibration of the DSCOVR EPIC Instrument’s Visible Cchannels Using MODIS and VIIRS as a Reference

The Earth Polychromatic Imaging Camera (EPIC) instrument aboard the Deep Space Climate Observatory (DSCOVR) satellite has a constant unique view of the sunlit disk of the Earth from the Lagrange-1 (L1) point nearly a million miles away from the Earth. Due to EPIC not having any on-board calibration systems, the ten spectral channels of EPIC must be inter-calibrated using vicarious on-orbit methods, such as ray-matching with well-calibrated low Earth orbiting satellites like the Aqua-MODIS and SNPP-VIIRS radiometers. The recently released EPIC version 3 L1B data has greatly enhanced the residual navigation errors found in prior versions, thereby decreasing the calibration uncertainty in the aforementioned ray-matching calibration techniques. The automated navigation correction used by these ray-matching methods for further improving the EPIC geolocation will be compared with a new navigation correction method utilizing optical flow between the EPIC and MODIS/VIIRS images. The DSCOVR satellite went into safe mode on June 27, 2019 due to an anomaly with the satellite’s attitude control system, but operations recommenced on March 2, 2020. The calibration of the EPIC instrument before it went into safe mode and after it resumed will be analyzed in order to investigate any potential calibration shifts or discontinuities caused by the spacecraft anomaly.

Conor Haney↗

Using DSCOVR EPIC as an Additional Calibration Reference to Radiometrically Scale the Geo Imagers for the NASA CERES Project

The NASA CERES project provides climate-quality observed TOA and calculated surface fluxes to the climate community. The CERES instruments are mounted on the Aqua, Terra, NPP, and NOAA-20 low earth orbiting (LEO) satellites, where they are used alongside the VIIRS and MODIS based cloud properties necessary for converting CERES radiance observations into fluxes. The CERES SYN1deg product provides the regional hourly fluxes in between the Terra and Aqua/NOAA-20-CERES observations based on geostationary imager (GEO) radiances. The GEO radiances are radiometrically scaled to the MODIS or VIIRS calibration references. The GEO and MODIS inter-calibration events are limited by the Aqua-MODIS or VIIRS local equator crossing time of 1:30 PM. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth, and the Earth Polychromatic Imaging Camera (EPIC) instrument onboard DSCOVR has a constant view of the sunlit side of the Earth while taking images ranging from the UV to the NIR throughout the day. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that EPIC is radiometrically stable, which allows it to potentially be used as a transfer radiometer between imagers. This study will assess the viability of using EPIC as a consistent and stable calibration source for GEO imagers. EPIC will be inter-calibrated with Himawari-8 that has been radiometrically scaled with Aqua. The Himawari-8 based EPIC calibration gains will be verified by the EPIC calibration gains determined directly from Aqua-MODIS matches. The EPIC calibration gains based on Himawari-8 will be stratified by local time to determine any diurnal dependence of the GEO/EPIC calibration strategy.

C O Haney↗

Precision insolation measurement under field conditions

Work at the Jet Propulsion Laboratory had resulted in the development of a primary absolute cavity radiometer (PACRAD), which was recently accepted as an international standard of irradiance. The development of an wall-weather, field-worthy solar radiometer based on the PACRAD is discussed, and its calibration stability over a two-year period in the field is described.

Reid, M. S.↗

Thermal Pollution Mathematical Model. Volume 5: User's Manual for Three-Dimensional Rigid-Lid Model

A user's manual for a three dimensional, rigid lid model used for hydrothermal predictions of closed basins subjected to a heated discharge together with various other inflows and outflows is presented. The model has the capability to predict (1) wind driven circulation; (2) the circulation caused by inflows and outflows to the domain; and (3) the thermal effects in the domain, and to combine the above processes. The calibration procedure consists of comparing ground truth corrected airborne radiometer data with surface isotherms predicted by the model. The model was verified for accuracy at various sites and results are found to be fairly accurate in all verification runs.

Lee, S. S.↗

Retrieval of ocean surface parameters from the scanning multifrequency microwave radiometer (SMMR) on the Nimbus-7 satellite

Sea-surface temperature retrievals have been tested on 2 months of Nimbus-7 scanning multichannel microwave radiometer data. Using the prelaunch versions of the instrument calibration and geophysical parameter retrieval algorithms the initial results were poor. Improved algorithms produced substantially better results. It appears that at least for the night-Southern Hemisphere portion of the Nimbus-7 orbit, a rms measurement accuracy of 1.45 C has been achieved. Similar tests with wind speed retrievals yield an accuracy of 2.7 m/s rms with no substantial differences between day and night measurements but limited by availability of surface observations to the Northern Hemisphere. Moreover, it appears that the retrieved wind speed is more nearly related to the square of the wind observed at the surface than to the wind itself.

Wilheit, T. T., Jr.↗

Satellite measurement of aerosol mass over land

The estimation of aerosol optical thickness and mass from satellite observations over land is demonstrated using data from the GOES Visible/IR Spin-Scan Radiometer for the eastern U.S. The post-launch calibration technique is described; the algorithm used to derive optical thickness from the radiance of scattered sunlight (by means of a radiative-transfer model in which the optical characteristics of the aerosol are assumed) is presented; and data on aerosol S for July 31, 1980 are analyzed. The results are presented in a series of graphs and maps and compared with ground-based data. The errors in the optical thickness and columnar mass are estimated as 15 and 40 percent, respectively, and the need for independent-data-set validation of satellite-based mass, transport, and divergence values is indicated.

Fraser, R. S.↗

A few parts in 10 to the 8th geodetic baseline repeatablity in the Gulf of California using the Global Positioning System

GPS geodetic measurements of 350-650 km baselines across the Pacific-North America plate boundary in the Gulf of California are presented. The analysis employs a four-station U.S. fiducial network and combined carrier phase and pseudorange data. Water vapor radiometer data at the Gulf sites are used to calibrate the GPS signal for wet tropospheric path delays. Residual tropospheric delays are modeled as first-order exponentially correlated stochastic processes. The measurement precision for horizontal components is a few parts in 10 to the 8th or better.

Tralli, David M.↗

Earth Radiation Imbalance from a Constellation of 66 Iridium Satellites: Technological Aspects

Iridium Communications Inc. is launching a new generation of polar orbiting communication satellites in 2015-2017. Iridium will provide a hosted payload bay on each of the 66 satellites (plus 6 in-space spares). This offers the potential for a paradigm shift in the way we measure Earth radiation imbalance from space, as well as massive cost savings. Because the constellation provides 24/7 global coverage, there is no need to account for diurnal cycle via extrapolations from uncalibrated narrowband geostationary imagers. And the spares can be rolled over to view the Sun and deep space, then transfer their calibration to the other members of the constellation during the frequent cross-overs. In part using simulations of the constellation viewing realistic Earth scenes, this presentation will address the technological aspects of such a constellation: (1) the calibration strategy; (2) the highly-accurate and stable radiometers for measuring outgoing flux; and (3) the GRACE-inspired algorithms for representing the outgoing flux field in spherical harmonics and thus achieving rv500-km spatial resolution and two-hour temporal resolution.

Wiscombe, W.↗