Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution test pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Semi-Supervised Eigenbasis Novelty Detection

Recent discoveries in high-time-resolution radio astronomy data have focused attention on a new class of events. Fast transients are rare pulses of radio frequency energy lasting from microseconds to seconds that might be produced by a variety of exotic astrophysical phenomena. For example, X-ray bursts, neutron stars, and active galactic nuclei are all possible sources of short-duration, transient radio signals. It is difficult to anticipate where such signals might appear, and they are most commonly discovered through analysis of high-time- resolution data that had been collected for other purposes. Transients are often faint and difficult to detect, so improved detection algorithms can directly benefit the science yield of all such commensal monitoring. A new detection algorithm learns a low-dimensional linear manifold for describing the normal data. High reconstruction error indicates a novel signal that does not match the patterns of normal data. One unsupervised portion of the manifold model adapts its representation in response to recent data. A second supervised portion of the model is made of a basis trained in advance using labeled examples of RFI; this prevents false positives due to these events. For a linear model, an orthonormalization operation is used to combine these bases prior to the anomaly detection decision. Another novel aspect of the approach lies in combining basis vectors learned in an unsupervised, online fashion from the data stream with supervised basis vectors learned in advance from known examples of false alarms. Adaptive, data-driven detection is achieved that is also informed by existing domain knowledge about signals that may be statistically anomalous, but are not interesting and should therefore be ignored. The method was evaluated using data from the Parkes Multibeam Survey. This data set was originally collected to search for pulsars, which are astronomical sources that emit radio pulses at regular periods. However, several non-pulsar anomalies have recently been discovered in this dataset, making it a compelling test case. By explicitly filtering known false alarm patterns, the approach yields significantly better performance than current transient detection methods.

Wagstaff, Kiri L.↗

Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector

Purpose: The goal of this study is to evaluate a new method based on a coded aperture mask combined with a digital x-ray imaging detector for measurements of the focal spot sizes of diagnostic x-ray tubes. Common techniques for focal spot size measurements employ a pinhole camera, a slit camera, or a star resolution pattern. The coded aperture mask is a radiation collimator consisting of a large number of apertures disposed on a predetermined grid in an array, through which the radiation source is imaged onto a digital x-ray detector. The method of the coded mask camera allows one to obtain a one-shot accurate and direct measurement of the two dimensions of the focal spot (like that for a pinhole camera) but at a low tube loading (like that for a slit camera). A large number of small apertures in the coded mask operate as a ''multipinhole'' with greater efficiency than a single pinhole, but keeping the resolution of a single pinhole. Methods: X-ray images result from the multiplexed output on the detector image plane of such a multiple aperture array, and the image of the source is digitally reconstructed with a deconvolution algorithm. Images of the focal spot of a laboratory x-ray tube (W anode: 35-80 kVp; focal spot size of 0.04 mm) were acquired at different geometrical magnifications with two different types of digital detector (a photon counting hybrid silicon pixel detector with 0.055 mm pitch and a flat panel CMOS digital detector with 0.05 mm pitch) using a high resolution coded mask (type no-two-holes-touching modified uniformly redundant array) with 480 0.07 mm apertures, designed for imaging at energies below 35 keV. Measurements with a slit camera were performed for comparison. A test with a pinhole camera and with the coded mask on a computed radiography mammography unit with 0.3 mm focal spot was also carried out. Results: The full width at half maximum focal spot sizes were obtained from the line profiles of the decoded images, showing a focal spot of 0.120 mmx0.105 mm at 35 kVp and M=6.1, with a detector entrance exposure as low as 1.82 mR (0.125 mA s tube load). The slit camera indicated a focal spot of 0.112 mmx0.104 mm at 35 kVp and M=3.15, with an exposure at the detector of 72 mR. Focal spot measurements with the coded mask could be performed up to 80 kVp. Tolerance to angular misalignment with the reference beam up to 7 deg. in in-plane rotations and 1 deg. deg in out-of-plane rotations was observed. The axial distance of the focal spot from the coded mask could also be determined. It is possible to determine the beam intensity via measurement of the intensity of the decoded image of the focal spot and via a calibration procedure. Conclusions: Coded aperture masks coupled to a digital area detector produce precise determinations of the focal spot of an x-ray tube with reduced tube loading and measurement time, coupled to a large tolerance in the alignment of the mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Limited-angle effect compensation for respiratory binned cardiac SPECT

Purpose: In cardiac single photon emission computed tomography (SPECT), respiratory-binned study is used to combat the motion blur associated with respiratory motion. However, owing to the variability in respiratory patterns during data acquisition, the acquired data counts can vary significantly both among respiratory bins and among projection angles within individual bins. If not properly accounted for, such variation could lead to artifacts similar to limited-angle effect in image reconstruction. In this work, the authors aim to investigate several reconstruction strategies for compensating the limited-angle effect in respiratory binned data for the purpose of reducing the image artifacts. Methods: The authors first consider a model based correction approach, in which the variation in acquisition time is directly incorporated into the imaging model, such that the data statistics are accurately described among both the projection angles and respiratory bins. Afterward, the authors consider an approximation approach, in which the acquired data are rescaled to accommodate the variation in acquisition time among different projection angles while the imaging model is kept unchanged. In addition, the authors also consider the use of a smoothing prior in reconstruction for suppressing the artifacts associated with limited-angle effect. In our evaluation study, the authors first used Monte Carlo simulated imaging with 4D NCAT phantom wherein the ground truth is known for quantitative comparison. The authors evaluated the accuracy of the reconstructed myocardium using a number of metrics, including regional and overall accuracy of the myocardium, uniformity and spatial resolution of the left ventricle (LV) wall, and detectability of perfusion defect using a channelized Hotelling observer. As a preliminary demonstration, the authors also tested the different approaches on five sets of clinical acquisitions. Results: The quantitative evaluation results show that the three compensation methods could all, but to different extents, reduce the reconstruction artifacts over no compensation. In particular, the model based approach reduced the mean-squared-error of the reconstructed myocardium by as much as 40%. Compared to the approach of data rescaling, the model based approach further improved both the overall and regional accuracy of the myocardium; it also further improved the lesion detectability and the uniformity of the LV wall. When ML reconstruction was used, the model based approach was notably more effective for improving the LV wall; when MAP reconstruction was used, the smoothing prior could reduce the noise level and artifacts with little or no increase in bias, but at the cost of a slight resolution loss of the LV wall. The improvements in image quality by the different compensation methods were also observed in the clinical acquisitions. Conclusions: Compensating for the uneven distribution of acquisition time among both projection angles and respiratory bins can effectively reduce the limited-angle artifacts in respiratory-binned cardiac SPECT reconstruction. Direct incorporation of the time variation into the imaging model together with a smoothing prior in reconstruction can lead to the most improvement in the accuracy of the reconstructed myocardium.

60 APPLIED LIFE SCIENCES↗

Integrating very-high-resolution UAS data and airborne imaging spectroscopy to map the fractional composition of Arctic plant functional types in Western Alaska

Widespread changes in vegetation cover and composition are driving strong impacts on Arctic ecosystem functioning and global climate feedbacks. An accurate characterization of tundra vegetation composition is required to understand how the Arctic will respond to future climate change. However, quantifying tundra vegetation composition over large areas is challenging as commonly-used satellite observations are too coarse, spatially and spectrally, to differentiate low-lying tundra vegetation types. Recent airborne and spaceborne imaging spectroscopy platforms provide better data to characterize vegetation composition. Yet, our ability to characterize vegetation composition with imaging spectroscopy remains largely unexplored in the Arctic, particularly due to a lack of ground observations needed to train and test classification models. To address this problem, we collected very-high-resolution (VHR, ~5 cm) unoccupied aerial system (UAS) imagery at three low-Arctic tundra sites located on the Seward Peninsula, western Alaska. In this paper, we examine the feasibility of integrating imagery from the UAS and the hyperspectral Airborne Visible/Infrared Imaging Spectrometer, Next Generation (AVIRIS-NG) airborne instrument to map the fractional composition of 12 key Arctic plant functional types (PFTs). To this end, we first mapped the 12 PFTs from our VHR UAS imagery using random forest classification. We then used these UAS-derived PFT maps as ground truth to develop partial least squares regression (PLSR) models to predict the fractional cover (FCover) of each PFT from AVIRIS-NG imagery. Further, we evaluated the performance of our PLSR models using reserved UAS samples, as well as by mapping PFT FCover and dominant PFT for large tundra landscapes. Our results show that 1) Arctic PFTs can be effectively mapped using VHR UAS imagery, with overall accuracy between 86% and 92%, 2) when the UAS mapped PFTs were used to inform PLSR scaling models, the FCover of the 12 PFTs could be effectively estimated from AVIRIS-NG imagery with a mean absolute error (MAE) <0.13, and 3) our PLSR models outperformed traditional, fully constrained least-squares (FCLS) linear mixture analysis and produced high-quality, spatially contiguous PFT FCover and PFT maps that captured vegetation spatial patterns with similar accuracy to those developed from UAS imagery. The developed PLSR models have the potential to be broadly applied for quantifying vegetation composition with AVIRIS-NG images to help monitor tundra vegetation dynamics and improve process-based modeling of tundra ecosystems.

54 ENVIRONMENTAL SCIENCES↗

The influence of the hydrologic cycle on the extent of sea ice with climatic implications

Multi-temporal satellite images, field observations, and field measurements were used to investigate the mechanisms by which sea ice melts offshore from the Mackenzie River delta. Advanced Very High Resolution Radiometer (AVHRR) satellite data recorded in 1986 were analyzed. The satellite data were geometrically corrected and radiometrically calibrated so that albedo and temperature values could be extracted. The investigation revealed that sea ice melted approximately 2 weeks earlier offshore from the Mackenzie River delta than along coasts where river discharge is minimal or non-existent. There is significant intra-delta variability in the timing and patterns of ice melt. An estimation of energy flux indicates that 30 percent more of the visible wavelength energy and 25 percent more of the near-infrared wavelength energy is absorbed by water offshore of the delta compared to coastal areas with minimal river discharge. The analysis also revealed that the removal of sea ice involves the following: over-ice-flooding along the coast offshore from river delta channels; under-ice flow of 'warm' river water; melting and calving of the fast ice; and, the formation of a bight in the pack ice edge. Two stages in the melting of sea ice were identified: (1) an early stage where heat is supplied to overflows largely by solar radiation, and (2) a later stage where heat is supplied by river discharge in addition to solar radiation. A simple thermodynamic model of the thaw process in the fast ice zone was developed and parameterized based on events recorded by the satellite images. The model treats river discharge as the source of sensible heat at the base of the ice cover. The results of a series of sensitivity tests to assess the influence of river discharge on the near shore ice are presented.

Dean, Kenneson G.↗

Development of microchannel plate x-ray optics

The goal of this research program was to develop a novel technique for focusing x-rays based on the optical system of a lobster's eye. A lobster eye employs many closely packed reflecting surfaces arranged within a spherical or cylindrical shell. These optics have two unique properties: they have unlimited fields of view and can be manufactured via replication of identical structures. Because the angular resolution is given by the ratio of the size of the individual optical elements to the focal length, optical elements with sizes on the order of one hundred microns are required to achieve good angular resolution with a compact telescope. We employed anisotropic etching of single crystal silicon wafers for the fabrication of micron-scale optical elements. This technique, commonly referred to as silicon micromachining, is based on silicon fabrication techniques developed by the microelectronics industry. An anisotropic etchant is a chemical which etches certain silicon crystal planes much more rapidly than others. Using wafers in which the slowly etched crystal planes are aligned perpendicularly to the wafer surface, it is possible to etch a pattern completely through a wafer with very little distortion. Our optics consist of rectangular pores etched completely through group of zone axes (110) oriented silicon wafers. The larger surfaces of the pores (the mirror elements) were aligned with the group of zone axes (111) planes of the crystal perpendicular to the wafer surface. We have succeeded in producing silicon lenses with a geometry suitable for 1-d focusing x-ray optics. These lenses have an aspect ratio (40:1) suitable for x-ray reflection and have very good optical surface alignment. We have developed a number of process refinements which improved the quality of the lens geometry and the repeatability of the etch process. A significant progress was made in obtaining good optical surface quality. The RMS roughness was decreased from 110 A for our initial lenses to 30 A in the final lenses. A further factor of three improvement in surface quality is required for the production of efficient x-ray optics. In addition to the silicon fabrication, an x-ray beam line was constructed at Columbia for testing the optics.

Kaaret, Philip↗

Multimodal Nondestructive Dry Cask Basket Structure and Spent Fuel Evaluation

This NEUP-IRP assembled a team from diverse institutions and a diverse set of expertise to examine the problem of assessing the structural health of dry nuclear fuel storage casks, specifically the TN-32 design. With no physical access designed into these storage casks and the high cost and risk associated with opening casks for direct inspection, the technical difficulty of structural assessment of the basket structure and fuel assemblies is high. In response to this challenge, this IRP brought together experts in both traditional and novel NDE methodologies: active acoustics (University of Mississippi), emissions tomography (University of Florida), muon tomography (Oregon State University), and passive-active ultrasonics (University of South Carolina). Further, our industry partners in the Electric Power Research Institute (EPRI) and AREVA provided invaluable insight into technical design details for the cask, practical knowledge of operating parameters at a storage facility, and key relationships that enabled activities unforeseen at the time of the proposed work but were critical in guiding the path of the research. The team decided early in the project that we had a collective goal of laying the technical ground work for practical solutions that could be implemented in the field with reasonable cost, time, and reliability. A fortunate opportunity arose early in this IRP project to obtain access to a new TN-32 cask at Columbiana High Tech. Both acoustics teams were given access for testing concepts in the first year of the project. This ended up providing critical guidance in the design of subsequent laboratory experiments. Specifically, it became clear that the only reliable acoustic pathways to the interior were through the trunnions, base plate, and top ring of the cask. Based on these field tests and discussions about what would be of practical interest, the team as a whole decided a realistic goal was to detect catastrophic failure of a single fuel assembly, or one that was missing. It is clear from this work that the active acoustics / resonance and muon tomography methodologies would be capable of detecting interior structural integrity problems at this level. The other two areas of investigation (emissions tomography and passive/active ultrasonics) would need more testing to determine a successful implementation, but each may also have other applications such as long term monitoring and monitoring during transportation. This IRP project resulted in technical advances with applications that extend beyond the problem at hand, supported the training of 10 graduate students + 1 post doc, 21 publications, and 13 conference presentations. The remainder of this summary highlights significant activities and achievements in each of the methodologies and a brief discussion on how they can be combined to leverage strengths. Active Acoustics The active acoustics team at UM used both linear and non-linear structural resonance methods to infer information about the internal structure of a cask. Significant activities were a set of four field test measurements on a full scale TN-32 cask at the Columbiana Hi Tech facility in Greensboro, NC and the design and fabrication of a 1/6th scale model TN-32 cask for laboratory measurements. A significant set of acoustic data has been acquired on both the full scale and laboratory scale casks. It was determined early in the project that mechanical resonance techniques were not going to be sensitive to small scale (centimeter) cracks and structural defects in the basket structure or fuel assemblies. We were able to ascertain that both the energy and complexity of the resonance spectra were sensitive to “bulk state” of the fuel assemblies – an intact assembly versus a severely degraded assembly. By developing a novel combination of metrics, we are able to measure a statistically significant shift due to one out of the 32 fuel assemblies being either missing or degraded to a point of complete loss of structural coherence (i.e. “rubble”). We believe this combination of resonance metrics is new to the field and will have applications beyond the fuel storage problem. Emissions Tomography The Emissions Tomography team at the University of Florida explored the concept of using scattering of radiation emissions from the stored fuel as method of evaluating the internal structural health of the cask. Due to the need for emissive fuel assemblies and the difficulties of gaining access to storage facilities, this team primarily relied on simulations to inform feasibility. A key question was the flux estimates of neutrons with a small enough number of scattering events to retain spatial information. Some key conclusions from the transmission component of this work are that the number of scattering events falls rapidly with energy – setting a 11MeV threshold, the average number of scattering events is 8∓4. Rough estimates of scanning times using an ideal detector array would be 1 week. The team also explored the case of significant structural failure resulting in a shift of the source material (fuel). The result is that a +/- 2% mass shift results in a detectable (5.13%) shift in the correlated 2 neutron emission counts and thus may be a candidate as an initial survey. Finally, simulations for predicting the azimuthal dependence of the flux based on specific loading patterns were conducted. Due to self-shielding effects of the assemblies, a periodic pattern results and could potentially be used to identify missing or severely degraded assemblies. This work forms a basis for proper detector placement with the goal of optimizing sensitivity. Muon Tomography Muon tomography (MT) is a relatively novel method of interrogating interior structure on a large scale. One of the advantages of this technique is that the exciting energy source (cosmic muons) is ubiquitous and relatively stable in time. Challenging aspects are relatively low flux rates and appropriate detector technologies. The efforts of the muon group at Oregon State University focused on two areas: (1) simulation of various combinations of muon scattering events and detection schemes to assess sensitivities and time scales for image construction and (2) building a prototype muon detection system applicable to the dry storage cask problem as well as many other similar systems. Significant accomplishments in this area are: (1) demonstration that MT is a viable method for detecting missing or severely degraded rod assemblies, (2) a scintillation based detector with 4 panels and 32 channels of position data each were constructed, tested, and calibrated. Testing of the panels using natural muon background and no scattering objects yielded largely expected results – a straight line path for the muon through the four panels. However some anomalies (paths deviating from a line) were also detected. A redesign of the board improved the signal which greatly improved the muon tracking through the panels. Testing with lead bricks as scattering bodies showed a reduction in the coincidence rate with increasing bricks indicating increased scattering events. A refinement of the scintillator detector design resulted in a spatial image resolution of around 2 cm based on lead brick spacing tests lasting 24 hours. Passive/Active Ultrasonics This team at the University of South Carolina investigated the feasibility of combining passive ultrasonics, in which an elastic pulse is generated by a degradation process (such as a crack extending), and active ultrasonics, in which a known excitation is introduced into the structure and detected by an array of transducers. Significant accomplishments in this area include the development of elastic wave propagation simulation in relevant materials, development of diagnostic algorithms, and laboratory testing and validation using laser doppler vibrometry. This group demonstrated the applicability of various non-contact vibration detection methodologies such as air-coupled ultrasonic transducers and scanning laser doppler vibrometry. While passive acoustic emissions monitoring will likely have a role during the transportation of a fuel storage cask, the level of detailed information about the defect generating the event which can be ascertained from the detections in a complex structure remains for future work. Thermography The EPRI team contributed early in the project a series of thermography measurements in which various levels of water pooled in a mock-up canister were analyzed using commercially available infrared imaging technologies. While large levels of water (100 L, ~10 cm deep) were observable in the thermograms, more realistic levels of pooled water (1 L) were not detectable whether localized or distributed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The microstructure and rheology of a model, thixotropic nanoparticle gel under steady shear and large amplitude oscillatory shear (LAOS)

The microstructure-rheology relationship for a model, thermoreversible nanoparticle gel is investigated using a new technique of time-resolved neutron scattering under steady and time-resolved large amplitude oscillatory shear (LAOS) flows. A 21 vol. % gel is tested with varying strength of interparticle attraction. Shear-induced structural anisotropy is observed as butterfly scattering patterns and quantified through an alignment factor. Measurements in the plane of flow show significant, local anisotropy develops with alignment along the compressional axis of flow, providing new insights into how gels flow. The microstructure-rheology relationship is analyzed through a new type of structure-Lissajous plot that shows how the anisotropic microstructure is responsible for the observed LAOS response, which is beyond a response expected for a purely viscous gel with constant structure. The LAOS shear viscosities are observed to follow the “Delaware-Rutgers” rule. Rheological and microstructural data are successfully compared across a broad range of conditions by scaling the shear rate by the strength of attraction, providing a method to compare behavior between steady shear and LAOS experiments. However, important differences remain between the microstructures measured at comparatively high frequency in LAOS experiments and comparable steady shear experiments that illustrate the importance of measuring the microstructure to properly interpret the nonlinear, dynamic rheological response.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonintrusive reduced order modeling framework for quasigeostrophic turbulence

In this study, we present a nonintrusive reduced order modeling (ROM) framework for large-scale quasistationary systems. The framework proposed in this work exploits the time series prediction capability of long short-term memory (LSTM) recurrent neural network architecture such that (1) in the training phase, the LSTM model is trained on the modal coefficients extracted from the high-resolution data snapshots using proper orthogonal decomposition (POD) transform, and (2) in the testing phase, the trained model predicts the modal coefficients for the total time recursively based on the initial time history. Hence, no prior information about the underlying governing equations is required to generate the ROM. To illustrate the predictive performance of the proposed framework, the mean flow fields and time series response of the field values are reconstructed from the predicted modal coefficients by using an inverse POD transform. As a representative benchmark test case, we consider a two-dimensional quasigeostrophic ocean circulation model which, in general, displays an enormous range of fluctuating spatial and temporal scales. We first demonstrate that the conventional Galerkin projection-based reduced order modeling of such systems requires a high number of POD modes to obtain a stable flow physics. In addition, ROM-Galerkin projection (ROM-GP) does not seem to capture the intermittent bursts appearing in the dynamics of the first few most energetic modes. However, the proposed nonintrusive ROM framework based on LSTM (ROM-LSTM) yields a stable solution even for a small number of POD modes. We also observe that the ROM-LSTM model is able to capture quasiperiodic intermittent bursts accurately, and yields a stable and accurate mean flow dynamics using the time history of a few previous time states, denoted as the lookback time window in this paper. We show several features of ROM-LSTM framework such as significantly higher accuracy than ROM-GP, and faster performance using larger time step size. Throughout the paper, we demonstrate our findings in terms of time series evolution of the field values and mean flow patterns, which suggest that the proposed fully nonintrusive ROM framework is robust and capable of predicting chaotic nonlinear fluid flows in an extremely efficient way compared to the conventional projection-based ROM framework.

42 ENGINEERING↗

Fabrication of nanoporous membranes for tuning microbial interactions and biochemical reactions

Here we describe how new strategies for combining conventional photo- and soft- lithographic techniques with high-resolution patterning and etching strategies are needed in order to produce multi-scale fluidic platforms that address the full range of functional scales seen in complex biological and chemical systems. The smallest resolution required for an application often dictates the fabrication method used. Micromachining and micro-powder blasting yield higher throughput, but lack the resolution needed to fully address biological and chemical systems at the cellular and molecular scales. In contrast, techniques such as electron beam lithography or nanoimprinting allow nanoscale resolution, but are traditionally considered costly and slow. Other techniques such as photolithography or soft lithography have characteristics between these extremes. Combining these techniques to fabricate multi-scale or hybrid fluidics allows fundamental biological and chemical questions can be answered. In this study, a combination of photolithography and electron beam lithography are used to produce two multi-scale fluidic devices that incorporate porous membranes into complex fluidic networks to control the flow of energy, information, and materials in chemical form. In the first device, materials and energy were used to support chemical reactions. A nanoporous membrane fabricated with e-beam lithography separates two parallel, serpentine channels. Photolithography was used to write microfluidic channels around the membrane. The pores were written at 150nm and reduced in size with silicon dioxide deposition from plasma enhanced chemical vapor deposition (PECVD) and atomic layer deposition (ALD). Using this method, the molecular weight cutoff (MWCO) of the membrane can be adapted to the system of interest. In the second approach, photolithography was used to fabricate 200nm thin pores. The pores confined microbes and allowed energy replenishment from a media perfusion channel. The same device can be used for study of intercellular communication via the secretion and uptake of signal molecules. Pore size was tested with 750nm fluorescent polystyrene beads and fluorescein dye. The 200nm PDMS pores were shown to be robust enough to hold 750nm beads while under pressure, but allow fluorescein to diffuse across the barrier. Further testing showed that extended culture of bacteria within the chambers was possible. Finally, these two examples show how lithographically defined porous membranes can be adapted to two unique situations and used to tune the flow of chemical energy, materials, and information within a microfluidic network.

36 MATERIALS SCIENCE↗

Exploring the Limits of the Data-Model-Theory Synergy: “Hot” MW Transitions for Rovibrational IR Studies

In order to further improve the accuracy of rovibrational IR line lists generated from the “Best Theory +Reliable High-resolution Experiment” (BTRHE) strategy from 0.01-0.05 cm-1, or 300-1500 MHz, to ~10 MHz, we explore the current limits of the Data-Model-Theory synergy by examining the accuracy and consistency of existing data, then propose that “hot” bands in microwave (MW) spectra is the solution we need for future enhancements. The Ames SO2 J=0-20 rovibrational energy levels computed on the semi-empirically refined Ames-2 potential energy surface (PES) are fit to the Effective Hamiltonian (EH) model regularly used in the experimental infrared (IR) analysis for SO2 isotopologues. In the fitted EH(Ames) model, the rotational constants A/B/C and all 5 quartic centrifugal distortion constants display clear, systematic, and consistent patterns along the vibrational state energy or quanta. Such consistent patterns may facilitate the vibrational assignments for MW hot bands and extract more information from high temperature MW spectra. Some EH(Expt) analyses were carried out with the lowest order Coriolis Coupling term, C1. Their constants should not be directly compared with other EH(Expt) and EH(Ames) results. After excluding them, our  = EH(Ames)- EH(Expt) analyses for 5 isotopologues (626, 636, 646, 628 and 828) indicates some loss of accuracy and consistency starting from vibrational states as low as 22 or 1000 cm-1. Some EH parameters, e.g. K, may have relative deviations as large as 50-100% and totally lose any recognizable patterns. This simply means that current EH(Expt) models do not have the system-wide consistency we need to further refine the EH(Ames) and Ames rovibrational IR line lists. A large part of such defects are probably inherited from the limited precision of experimental line positions, i.e. 1E-3 ~ 1E-4 cm-1, or 3-30 MHz. This is confirmed in a series of truncation tests using the Ames data. Although the EH(Ames) consistency may help identify unreliable rovibrational EH(Expt) parameters, and make reliable predictions for minor isotopologues and unobserved vibrational bands, we believe only the highly accurate “hot” MW transitions can provide real enhancements for EH(Expt) accuracy and consistency. “Hot” MW spectra should play a more significant role in the future synergy of Data, Model, and Theory in the field of rovibrational IR studies.

Xinchuan Huang↗

AFM Studies of Lunar Soils and Application to the Mars 2001 Mission

The upcoming Mars 01 mission will carry an Atomic Force Microscope (AFM) as part of the Mars Environmental Compatibility Assessment (MECA) instrument. By operating in a tapping mode, the AFM is capable of sub-nanometer resolution in three dimensions and can distinguish between substances of different compositions by employing phase contrast imaging. To prepare for the Mars 01 mission, we are testing the AFM on a lunar soil to determine its ability to define particle shapes and sizes and grain-surface textures. The test materials are from the Apollo 17 soil 79221, which is a mixture of agglutinates, impact and volcanic beads, and mare and highland rock and mineral fragments. The majority of the lunar soil particles are less than 100 microns in size, comparable to the sizes estimated for martian dust. We have used the AFM to examine several different soil particles at various resolutions. The instrument has demonstrated the ability to identify parallel ridges characteristic of twinning on a 150 micron plagioclase feldspar particle. Extremely small (10-100 nanometer) adhering particles are visible on the surface of the feldspar grain, and they appear elongate with smooth surfaces. Phase contrast imaging of the nanometer particles shows several compositions to be present. When the AFM was applied to a 100 micron glass spherule, it was possible to define an extremely smooth surface; this is in clear contrast to results from a basalt fragment which exhibited a rough surface texture. Also visible on the surface of the glass spherule were chains of 100 nanometer and smaller impact melt droplets. For the '01 Mars mission, the AFM is intended to define the size and shape distributions of soil particles, in combination with the NMCA optical microscope system and images from the Robot Arm Camera (RAC). These three data sets will provide a means of assessing potentially hazardous soil and dust properties. The study that we have conducted on the lunar soils now suggests that the NMCA experiment will be able to define grain transport and weathering processes. For example, it should be possible to determine if Martian grains have been subjected to aeolian or water transport, volcanic activity, impact melting processes, in-situ weathering, and a host of other processes. Additionally, textural maturity could be assessed (via freshness and form of fracture patterns and grain shapes). Thus, the AFM has the potential to shed new light on Martian surface processes by adding the submicroscopic dimension to planetary investigations.

Weitz, C. M.↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗

Ultrasound Thermal Field Imaging of Opaque Fluids

We have initiated an experimental program to develop an ultrasound system for non-intrusively imaging the thermal field in opaque fluids under an externally imposed temperature gradient. Many industrial processes involve opaque fluids, such as molten metals, semiconductors, and polymers, often in situations in which thermal gradients are important. For example, one may wish to understand semiconductor crystal growth dynamics in a Bridgman apparatus. Destructive testing of the crystal after the process is completed gives only indirect information about the fluid dynamics of the formation process. Knowledge of the coupled thermal and velocity fields during the growth process is then essential. Most techniques for non-intrusive velocity and temperature measurement in fluids are optical in nature, and hence the fluids studied must be transparent. In some cases (for example, LDV (laser Doppler velocimetry) and PIV (particle imaging velocimetry)) the velocities of small neutrally buoyant seed particles suspended in the fluid, are measured. Without particle seeding one can use the variation of the index of refraction of the fluid with temperature to visualize, through interferometric, Schlieren or shadowgraph techniques, the thermal field. The thermal field in turn gives a picture of the pattern existing in the fluid. If the object of study is opaque, non-optical techniques must be used. In this project we focus on the use of ultrasound, which propagates easily through opaque liquids and solids. To date ultrasound measurements have almost exclusively relied on the detection of sound scattered from density discontinuities inside the opaque material of interest. In most cases it has been used to visualize structural properties, but more recently the ultrasound Doppler velocimeter has become available. As in the optical case, it relies on seed particles that scatter Doppler shifted sound back to the detector. Doppler ultrasound techniques are, however, not useful for studying convective fluid flow in crystal growth, because particle seeding is unacceptable and flow velocities are typically too low to be resolved, and may be even lower in microgravity conditions where buoyancy forces are negligible. We will investigate a different use of ultrasound to probe the flows of opaque fluids non-intrusively and without the use of seed particles: our goal is to ultrasonically visualize the thermal field of opaque fluids with relatively high spatial resolution. The proposed technique relies upon the variation of sound speed with temperature of the fluid. A high frequency ultra-sound pulse passing through a fluid-filled chamber will traverse the chamber in a time determined by the relevant chamber dimension and the temperature of the fluid through which the pulse passes. With high time-resolution instrumentation that compares the excitation signal with the received pulse we can detect the influence of the fluid temperature on the pulse travel time. This is effectively an interferometric system, which in its optical form is an extremely sensitive approach to measuring thermal fields in fluids. Moreover, the temperature dependence of sound velocity in liquid metals is comparable to the temperature dependence of the speed of light required for accurate interferometric thermal images in transparent fluids. With an array of transducers scanned electronically a map of the thermal field over the chamber could be produced. An alternative approach would be to use the ultrasound analog of the shadowgraph technique. In the optical version, collimated light passes through the fluid, where it is focused or defocused locally by temperature field induced variations of the index of refraction. The resulting image reveals the thermal field through the spatial pattern of light intensity variations. By analogy, an ultrasound plane wave traversing an opaque fluid sample would be also locally focused or defocused depending on the speed of sound variations, giving rise to spatial variations in sound intensity that will reveal the thermal field pattern. These approaches could be applied to any situation in which temperature differences are expected to occur, and will rapidly provide information about the flow that simply cannot be obtained by any current intrusive or non-intrusive diagnostic technique. As materials processing in microgravity matures it will become increasingly important to have available simple and versatile diagnostic tools, such as we will develop, for studying the flows of opaque fluids under thermal forcing.

Andereck, C. David↗

STELLAR NUCLEOSYNTHESIS IN THE HYADES OPEN CLUSTER

We report a comprehensive light-element (Li, C, N, O, Na, Mg, and Al) abundance analysis of three solar-type main sequence (MS) dwarfs and three red giant branch (RGB) clump stars in the Hyades open cluster using high-resolution and high signal-to-noise spectroscopy. The abundances have been derived in a self-consistent fashion, and for each group (MS or RGB), the CNO abundances are found to be in excellent star-to-star agreement. Using the dwarfs to infer the initial composition of the giants, the combined abundance patterns confirm that the giants have undergone the first dredge-up and that material processed by the CN cycle has been mixed to the surface layers. The observed abundances are compared to predictions of a standard stellar model based on the Clemson-American University of Beirut (CAUB) stellar evolution code. The model reproduces the observed evolution of the N and O abundances, as well as the previously derived {sup 12}C/{sup 13}C ratio, but it fails to predict by a factor of 1.5 the observed level of {sup 12}C depletion. A similar discord appears to exist in previously reported observed and modeled C abundances of giants in the Galactic disk. Random uncertainties in the mean abundances and uncertainties related to possible systematic errors in the Hyades dwarf and giant parameter scales cannot account for the discrepancy in the observed and modeled abundances. Li abundances are derived to determine if noncanonical extra mixing, like that seen in low-mass metal-poor giants, has occurred in the Hyades giants. The Li abundance of the giant {gamma} Tau is in good accord with the predicted level of surface Li dilution, but a {approx}0.35 dex spread in the giant Li abundances is found and cannot be explained by the stellar model. Possible sources of the spread are discussed; however, it is apparent that the differential mechanism responsible for the Li dispersion must be unrelated to the uniformly low {sup 12}C abundances of the giants. Na, Mg, and Al abundances are derived as an additional test of our stellar model. All three elements are found to be overabundant by 0.2-0.5 dex in the giants relative to the dwarfs. Such large enhancements of these elements are not predicted by the stellar model, and non-LTE effects significantly larger (and, in some cases, of opposite sign) than those implied by extant literature calculations are the most likely cause.

99 GENERAL AND MISCELLANEOUS↗

Potassium Stable Isotopic Compositions Measured by High-Resolution MC-ICP-MS

Potassium isotopic (K-41/K-39) compositions are notoriously difficult to measure. TIMS measurements are hindered by variable fractionation patterns throughout individual runs and too few isotopes to apply an internal spike method for instrumental mass fractionation corrections. Internal fractionation corrections via the K-40/K-39 ratio can provide precise values but assume identical K-40/K-39 ratios (e.g. 0.05% (1sigma) in [1]); this is appropriate in some cases (e.g. identifying excess K-41) but not others (e.g., determining mass fractionation effects and metrologically traceable isotopic abundances). SIMS analyses have yielded measurements with 0.25% precisions (1sigma) [2]. ICP-MS analyses are significantly affected by interferences from molecular species such as Ar-38H(+) and Ar-40H(+) and instrument mass bias. Single collector ICP-MS instruments in "cold plasma" mode have yielded uncertainties as low as 2% (1sigma, e.g. [3]). Although these precisions may be acceptable for some concentration determinations, they do not resolve isotopic variation in terrestrial materials. Here we present data from a series of measurements made on the Thermo Scientific NEPTUNE Plus multi-collector ICP-MS that demonstrate the ability to make K-41/K-39 ratio measurements with 0.07% precisions (1sigma). These data, collected on NIST K standards, indicate the potential for MC-ICP-MS measurements to look for K isotopic variations at the sub-permil level. The NEPTUNE Plus can sufficiently resolve 39K and 41K from the interfering 38ArH+ and 40ArH+ peaks in wet cold plasma and high-resolution mode. Measurements were made on small but flat, interference-free, plateaus (ca. 50 ppm by mass width for K-41). Although ICP-MS does not yield accurate K-41/K-39 values due to significant instrumental mass fractionation (ca. 6%), this bias can be sufficiently stable over the time required for several measurements so that relative K-41/K-39 values can be precisely determined via sample-standard bracketing. As cold plasma conditions can amplify matrix effects, experiments were conducted to test the matrix tolerance of measurements; the use of clean, matrix-matched samples and standards is critical. Limitations of the cold-plasma high-resolution MC-ICP-MS methodology with respect to matrix tolerance are discussed and compared with the limitations of TIMS methodologies.

Morgan, Leah E.↗

Detection of microcalcifications by characteristic magnetic susceptibility effects using MR phase image cross-correlation analysis

Purpose: To develop and evaluate a new method for detecting calcium deposits using their characteristic magnetic susceptibility effects on magnetic resonance (MR) images at high fields and demonstrate its potential in practice for detecting breast microcalcifications. Methods: Characteristic dipole signatures of calcium deposits were detected in magnetic resonance phase images by computing the cross-correlation between the acquired data and a library of templates containing simulated phase patterns of spherical deposits. The influence of signal-to-noise ratio and various other MR parameters on the results were assessed using simulations and validated experimentally. The method was tested experimentally for detection of calcium fragments within gel phantoms and calcium-like inhomogeneities within chicken tissue at 7 T with optimized MR acquisition parameters. The method was also evaluated for detection of simulated microcalcifications, modeled from biopsy samples of malignant breast cancer, inserted in silico into breast magnetic resonance imaging (MRIs) of healthy subjects at 7 T. For both assessments of calcium fragments in phantoms and biopsy-based simulated microcalcifications in breast MRIs, receiver operator characteristic curve analyses were performed to determine the cross-correlation index cutoff, for achieving optimal sensitivity and specificity, and the area under the curve (AUC), for measuring the method’s performance. Results: The method detected calcium fragments with sizes of 0.14–0.79 mm, 1 mm calcium-like deposits, and simulated microcalcifications with sizes of 0.4–1.0 mm in images with voxel sizes between (0.2 mm){sup 3} and (0.6 mm){sup 3}. In images acquired at 7 T with voxel sizes of (0.2 mm){sup 3}–(0.4 mm){sup 3}, calcium fragments (size 0.3–0.4 mm) were detected with a sensitivity, specificity, and AUC of 78%–90%, 51%–68%, and 0.77%–0.88%, respectively. In images acquired with a human 7 T scanner, acquisition times below 12 min, and voxel sizes of (0.4 mm){sup 3}–(0.6 mm){sup 3}, simulated microcalcifications with sizes of 0.6–1.0 mm were detected with a sensitivity, specificity, and AUC of 75%–87%, 54%–87%, and 0.76%–0.90%, respectively. However, different microcalcification shapes were indistinguishable. Conclusions: The new method is promising for detecting relatively large microcalcifications (i.e., 0.6–0.9 mm) within the breast at 7 T in reasonable times. Detection of smaller deposits at high field may be possible with higher spatial resolution, but such images require relatively long scan times. Although mammography can detect and distinguish the shape of smaller microcalcifications with superior sensitivity and specificity, this alternative method does not expose tissue to ionizing radiation, is not affected by breast density, and can be combined with other MRI methods (e.g., dynamic contrast-enhanced MRI and diffusion weighted MRI), to potentially improve diagnostic performance.

60 APPLIED LIFE SCIENCES↗

A petabyte size electronic library using the N-Gram memory engine

A model library containing petabytes of data is proposed by Triada, Ltd., Ann Arbor, Michigan. The library uses the newly patented N-Gram Memory Engine (Neurex), for storage, compression, and retrieval. Neurex splits data into two parts: a hierarchical network of associative memories that store 'information' from data and a permutation operator that preserves sequence. Neurex is expected to offer four advantages in mass storage systems. Neurex representations are dense, fully reversible, hence less expensive to store. Neurex becomes exponentially more stable with increasing data flow; thus its contents and the inverting algorithm may be mass produced for low cost distribution. Only a small permutation operator would be recalled from the library to recover data. Neurex may be enhanced to recall patterns using a partial pattern. Neurex nodes are measures of their pattern. Researchers might use nodes in statistical models to avoid costly sorting and counting procedures. Neurex subsumes a theory of learning and memory that the author believes extends information theory. Its first axiom is a symmetry principle: learning creates memory and memory evidences learning. The theory treats an information store that evolves from a null state to stationarity. A Neurex extracts information data without a priori knowledge; i.e., unlike neural networks, neither feedback nor training is required. The model consists of an energetically conservative field of uniformly distributed events with variable spatial and temporal scale, and an observer walking randomly through this field. A bank of band limited transducers (an 'eye'), each transducer in a bank being tuned to a sub-band, outputs signals upon registering events. Output signals are 'observed' by another transducer bank (a mid-brain), except the band limit of the second bank is narrower than the band limit of the first bank. The banks are arrayed as n 'levels' or 'time domains, td.' The banks are the hierarchical network (a cortex) and transducers are (associative) memories. A model Neurex was built and studied. Data were 50 MB to 10 GB samples of text, data base, and images: black/white, grey scale, and high resolution in several spectral bands. Memories at td, S(m(sub td)), were plotted against outputs of memories at td-1. S(m(sub td)) was Boltzman distributed, and memory frequencies exhibited self-organized criticality (SOC); i.e., 'l/f(sup beta)' after long exposures to data. Whereas output signals from level n may be encoded with B(sub output) = O(-log(2)f(sup beta)) bits, and input data encoded with B(sub input) = O((S(td)/S(td-1))(sup n)), B(sup output)/B(sub input) is much less than 1 always, the Neurex determines a canonical code for data and it is a lossless data compressor. Further tests are underway to confirm these results with more data types and larger samples.

Bugajski, Joseph M.↗