At least 469 records · Page 26

General purpose rocket furnace

A multipurpose furnace for space vehicles used for material processing experiments in an outer space environment is described. The furnace contains three separate cavities designed to process samples of the widest possible range of materials and thermal requirements. Each cavity contains three heating elements capable of independent function under the direction of an automatic and programmable control system. A heat removable mechanism is also provided for each cavity which operates in conjunction with the control system for establishing an isothermally heated cavity or a wide range of thermal gradients and cool down rates. A monitoring system compatible with the rocket telemetry provides furnace performance and sample growth rate data throughout the processing cycle.

Aldrich, B. R.↗

Radar image processing of real aperture SLAR data for the detection and identification of iceberg and ship targets

An iceberg detection and identification system consisting of a moderate resolution Side Looking Airborne Radar (SLAR) interfaced with a Radar Image Processor (RIP) based on a ROLM 1664 computer with a 32K core memory updatable to 64K is described. The system can be operated in high- or low-resolution sampling modes. Specifically designed algorithms are applied to digitized signal returns to provide automatic target detection and location, geometrically correct video image display and data recording. The real aperture Motorola AN/APS-94D SLAR operates in the X-band and is tunable between 9.10 and 9.40 GHz; its output power is 45 kW peak with a pulse repetition rate of 750 pulses per hour. Schematic diagrams of the system are provided, together with preliminary test data.

Marthaler, J. G.↗

The development of a power spectral density processor for C and L band airborne radar scatterometer sensor systems

A real-time signal processor was developed for the NASA/JSC L-and C-band airborne radar scatterometer sensor systems. The purpose of the effort was to reduce ground data processing costs. Conversion of two quadrature channels of data (like and cross polarized) was made to obtain Power Spectral Density (PSD) values. A chirp-z transform (CZT) approach was used to filter the Doppler return signal and improved high frequency and angular resolution was realized. The processors have been tested with record signals and excellent results were obtained. CZT filtering can be readily applied to scatterometers operating at other wavelengths by altering the sample frequency. The design of the hardware and software and the results of the performance tests are described in detail.

Harrison, D. A., III↗

Space processing applications rocket project. SPAR 8

The Space Processing Applications Rocket Project (SPAR) VIII Final Report contains the engineering report prepared at the Marshall Space Flight Center (MSFC) as well as the three reports from the principal investigators. These reports also describe pertinent portions of ground-based research leading to the ultimate selection of the flight sample composition, including design, fabrication, and testing, all of which are expected to contribute immeasurably to an improved comprehension of materials processing in space. This technical memorandum is directed entirely to the payload manifest flown in the eighth of a series of SPAR flights conducted at the White Sands Missile Range (WSMR) and includes the experiments entitled Glass Formation Experiment SPAR 74-42/1R, Glass Fining Experiment in Low-Gravity SPAR 77-13/1, and Dynamics of Liquid Bubbles SPAR Experiment 77-18/2.

Chassay, R. P.↗

Human exposure in low Earth orbit

Human exposure to trapped electrons and protons in low Earth orbit (LEO) is evaluated on a basis of a simple approximation of the human geometry for spherical shell shields of varying thickness. A data base is presented that may be used to make preliminary assessment of the impact of radiation exposure constraints on human performance. Detailed shielding studies should be performed before final design considerations. A sample impact assessment is discussed on the basis of presently accepted allowable exposure limits. A brief discussion is given on the anticipated impact of an ongoing reassessment of allowable exposure limits.

Wilson, J. W.↗

Space Processing Applications Rocket (SPAR) project: SPAR 10

The Space Processing Applications Rocket Project (SPAR) X Final Report contains the compilation of the post-flight reports from each of the Principal Investigators (PIs) on the four selected science payloads, in addition to the engineering report as documented by the Marshall Space Flight Center (MSFC). This combined effort also describes pertinent portions of ground-based research leading to the ultimate selection of the flight sample composition, including design, fabrication and testing, all of which are expected to contribute to an improved comprehension of materials processing in space. The SPAR project was coordinated and managed by MSFC as part of the Microgravity Science and Applications (MSA) program of the Office of Space Science and Applications (OSSA) of NASA Headquarters. This technical memorandum is directed entirely to the payload manifest flown in the tenth of a series of SPAR flights conducted at the White Sands Missile Range (WSMR) and includes the experiments entitled, Containerless Processing Technology, SPAR Experiment 76-20/3; Directional Solidification of Magnetic Composites, SPAR Experiment 76-22/3; Comparative Alloy Solidification, SPAR Experiment 76-36/3; and Foam Copper, SPAR Experiment 77-9/1R.

Poorman, R.↗

Gas permeation measurements on small polymer specimens

Mass spectrometry was used to measure oxygen and nitrogen permeabilities while polarography was used to measure oxygen permeabilities for several contact lens materials. Applicable sample holders were designed and fabricated to accommodate curved and flat specimens. A prepared standard was used to calibrate the mass spectrometric analyses. The oxygen permeability values determined by mass spectrometry were significantly greater than those determined by polarography. This was attributed to the phase boundary phenomena and the limiting oxygen permeance of water inherent in the polarographic technique. Polarographic values determined were in good agreement with proprietary values obtained by polarography, with the exception of one material.

Burns, Karen S.↗

Observation and comparison of rainfall measured at a high sample rate

Two NASA programs, the Effects of Heavy Rain on Aerodynamics and the Tropical Rainfall Measuring Mission, require accurate high-frequency rainfall measurements. A weight-measuring rain gauge was developed to collect rain data and configured to operate at a high sample rate. The design of the gauge and preliminary test are briefly described. Frequency distributions of rainfall rates determined at five observation sites in the U.S. and at one in Australia are presented.

Melson, W. E., Jr.↗

Microelectric Heterogeneous Hybrid Devices for Space Applications

The existing projects designated as SACA (Sample Ampoule Cartridge/Container Assembly) and QMI (Quench Module Insert) at NASA's MSFC (Marshall Space Flight Center) involve development of high-temperature coating materials. A number of material systems need to be evaluated for this purpose. The requirement of these coating materials included high emissivity (approaching unity), sufficient physical strength, appropriate thermal conductivity to dissipate heat, and above all high temperature (T is equal to or greater than 2000 C) withstanding capability. Potential materials for applications considered were non-oxide based materials such as tungsten carbide, tantalum carbide, compounds of niobium, etc.

Mohammad A. Alim↗

Magnetic Circuit Model of PM Motor-Generator to Predict Radial Forces

A magnetic circuit model is developed for a PM motor for flywheel applications. A sample motor is designed and modeled. Motor configuration and selection of materials is discussed, and the choice of winding configuration is described. A magnetic circuit model is described, which includes the stator back iron, rotor yoke, permanent magnets, air gaps and the stator teeth. Iterative solution of this model yields flux linkages, back EMF, torque, power, and radial force at the rotor caused by eccentricity. Calculated radial forces are then used to determine motor negative stiffness.

McLallin, Kerry↗

Optimizing Crystal Volume for Neutron Diffraction Studies

For structural studies with neutron diffraction more intense neutron sources, improved sensitivity detector and larger volume crystals are all means by which the science is being advanced to enable studies on a wider range of samples. We have chosen a simplistic approach using a well understood crystallization method, with minimal amounts of sample and using design of experiment techniques to maximize the crystal volume all for minimum effort. Examples of the application are given.

Snell, E. H.↗

Bioavailability of intranasal promethazine dosage forms in dogs

Intramuscular promethazine (PMZ) is used aboard the US Space Shuttle to ameliorate symptoms of space motion sickness. Bioavailability after an oral dose of PMZ during space flight is thought to be impaired because of gastrointestinal disturbances associated with weightlessness and space motion sickness. In an attempt to find an alternative dosage form for use in space, we evaluated two intranasal (i.n.) dosage forms of PMZ in dogs for absorption and bioavailability relative to that of an equivalent intramuscular dose. Promethazine (5 mg kg-1) was administered as two intranasal dosage forms and as an intramuscular (i.m.) dose to three dogs in a randomised cross-over design. Serial blood samples were taken and analysed for PMZ concentrations and the absorption and bioavailability of PMZ were calculated for the three dosage forms. PMZ absorption from the carboxymethyl cellulose microsphere i.n. dosage form was more rapid and complete than from the myverol cubic gel formulation or from an i.m. injection. Bioavailability of the microsphere formulation was also greater than that of the gel formulation (AUC 3009 vs 1727 ng h ml-1). The bioavailability of the two i.n. dosage forms (relative to that of the i.m. injection) were 94% (microsphere) and 54% (gel). The i.n. microsphere formulation of PMZ offers great promise as an effective non-invasive alternative for treating space motion sickness due to its rapid absorption and bioavailability equivalent to the i.m. dose.

NASA Center JSC↗

Design and Performance Assessment of a Stable Astigmatic Herriott Cell for Trace Gas Measurements on Airborne Platforms

The present paper discusses a new, more stable, astigmatic Herriott cell employing carbon fiber stabilizing rods. Laboratory tests using a near-IR absorption feature of CO at 1564.168-nm revealed a factor of two improvement in measurement stability compared with the present commercial design when the sampling pressure was changed by +/-2 Torr around 50 Torr. This new cell should significantly enhance our efforts to measure trace gases employing pathlengths of 100 to 200-meters on airborne platforms with minimum detectable line center absorbances of less than 10(exp -6).

Dyroff, Christoph↗

A 2-D Piston Effect Solution for the Relaxation in the MISTE Cell

When a large density stratification is no longer a problem in a microgravity environment, one would like to increase the sample size in order to increase the signal-to-noise ratio for a specific heat measurement. To reduce the equilibration time associated with the large sample size, we designed a cylindrical cell containing a stack of plates that separate the bulk fluid into 60 equally thin layers. To understand the thermal behavior of the whole cell, we analyzed the thermal behavior of a 2-D composite system of a cylindrical near-critical fluid layer in contact with a cylindrical copper plate. In this 2-D analysis, the circumference boundary of the two cylindrical layers is subjected to a step temperature change. The solution of this 2-D composite system includes the piston effect that speeds up the equilibration in the near-critical fluid layer and the pure diffusion in the copper plate. The results of this analysis indicate that the characteristic length for the equilibration of the stacked cell is determined by an effective thickness of a single fluid layer instead of the total height of the cylindrical cell.

Weilert, Mark↗

Optimization of Polycyclic Aromatic Hydrocarbon (PAH) Extraction Efficiency Parameters for Sub- and Supercritical Water Extraction (SCWE) Instrument

Polycyclic aromatic hydrocarbons are a class of molecules composed of multiple, bonded benzene rings. As PAHS are believed to be present on Mars, positive confirmation of their presence on Mars is highly desirable. To extract PAHS, which have low volatility, a fluid extraction method is ideal, and one that does not utilize organic solvents is especially ideal for in situ instrumental analysis. The use of water as a solvent, which at subcritical pressures and temperatures is relatively non-Polar, has significant potential. As SCWE instruments have not yet been commercialized, all instruments are individually-built research prototypes: thus, initial efforts were intended to determine if extraction efficiencies on the JPL-built laboratory-scale SCWE instrument are comparable to differing designs built elsewhere. Samples of soil with certified reference concentrations of PAHs were extracted using SCWE as well as conventional Soxhlet extraction. Continuation of the work would involve extractions on JPL'S newer, portable SCWE instrument prototype to determine its efficiency in extracting PAHs.

Okada, Asahi A.↗

Geolab 2010 Hardware in NASA's Pressurized Excursion Module

NASA is designing and building the Habitat Demonstration Unit - 1 in a Pressurized Excursion Module (HDU1- PEM) configuration for analog testing at NASA s annual Desert Research and Technology Studies (DRATS) near Flagstaff, Arizona in late summer 2010. The HDU1-PEM design is based on NASA Constellation program s Lunar Scenario 12.1 (nicknamed "Lunabago"). This scenario uses Lunar Electric Rovers (LER) and a PEM for long-distance lunar exploration. The 2010 HDU version 1.0 will be an unpressurized PEM that contains a GeoLab in one of the eight PEM sections. The GeoLab is designed to facilitate sample curation protocol development including such activities as preliminary examination, sample archiving, and high grading of astromaterials for return to Earth. Geolab operations will be integrated with the DRATS science traverses and operations.

Calaway, M. J.↗

Electrochemical Detection of Multiple Bioprocess Analytes

An apparatus that includes highly miniaturized thin-film electrochemical sensor array has been demonstrated as a prototype of instruments for simultaneous detection of multiple substances of interest (analytes) and measurement of acidity or alkalinity in bioprocess streams. Measurements of pH and of concentrations of nutrients and wastes in cell-culture media, made by use of these instruments, are to be used as feedback for optimizing the growth of cells or the production of desired substances by the cultured cells. The apparatus is designed to utilize samples of minimal volume so as to minimize any perturbation of monitored processes. The apparatus can function in a potentiometric mode (for measuring pH), an amperometric mode (detecting analytes via oxidation/reduction reactions), or both. The sensor array is planar and includes multiple thin-film microelectrodes covered with hydrous iridium oxide. The oxide layer on each electrode serves as both a protective and electrochemical transducing layer. In its transducing role, the oxide provides electrical conductivity for amperometric measurement or pH response for potentiometric measurement. The oxide on an electrode can also serve as a matrix for one or more enzymes that render the electrode sensitive to a specific analyte. In addition to transducing electrodes, the array includes electrodes for potential control. The array can be fabricated by techniques familiar to the microelectronics industry. The sensor array is housed in a thin-film liquid-flow cell that has a total volume of about 100 mL. The flow cell is connected to a computer-controlled subsystem that periodically draws samples from the bioprocess stream to be monitored. Before entering the cell, each 100-mL sample is subjected to tangential-flow filtration to remove particles. In the present version of the apparatus, the electrodes are operated under control by a potentiostat and are used to simultaneously measure the pH and the concentration of glucose. It is anticipated that development of procedures for trapping more enzymes into hydrous iridium oxide (and possibly into other electroactive metal oxides) and of means for imparting long-term stability to the transducer layers should make it possible to monitor concentrations of products of many enzyme reactions for example, such key bioprocess analytes as amino acids, vitamins, lactose, and acetate.

Rauh, R. David↗