Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Microbial load monitor

Attempts are made to provide a total design of a Microbial Load Monitor (MLM) system flight engineering model. Activities include assembly and testing of Sample Receiving and Card Loading Devices (SRCLDs), operator related software, and testing of biological samples in the MLM. Progress was made in assembling SRCLDs with minimal leaks and which operate reliably in the Sample Loading System. Seven operator commands are used to control various aspects of the MLM such as calibrating and reading the incubating reading head, setting the clock and reading time, and status of Card. Testing of the instrument, both in hardware and biologically, was performed. Hardware testing concentrated on SRCLDs. Biological testing covered 66 clinical and seeded samples. Tentative thresholds were set and media performance listed.

Caplin, R. S.↗

Hydraulic Conductivity Measurements, Utqiagvik (Barrow), Alaska, 2014

Six individual ice cores were collected from the Barrow Environmental Observatory in Barrow, Alaska, in May of 2013 as part of the Next Generation Ecosystem Experiment (NGEE). Each core was drilled at a different location to varying depths. After drilling, the cores were stored in coolers packed with dry ice and flown to Lawrence Berkeley National Laboratory (LBNL) in Berkeley, CA. 3-dimensional images of the cores were constructed using medical X-ray computed tomography (CT) scanner at 120kV. Hydraulic conductivity samples were extracted from these cores at LBNL Richmond Field Station in Richmond, CA, in February 2014 by cutting 5 to 8 inch segments using a chop saw. Samples were packed individually and stored at -20C freezing temperatures to minimize any changes in structure or loss of ice content prior to analysis. Hydraulic conductivity was determined through falling head tests using a permeameter [ELE International, Model #: K-770B] (Appendix A). Samples were placed in a latex membrane via a membrane stretcher while frozen. Use of a membrane stretcher made the membranes easier to secure and minimized contact with the sample. A clear polycarbonate sleeve, fabricated with a stainless steel ring at the bottom to keep the sleeve from floating, was placed around the sample inside the permeameter to minimize deformation during analysis. The permeameter was filled with water and 1.0 PSI of air was applied for confining pressure during sample defrost. Outflow valves were left open to allow for incremental thawing and samples were left to thaw for approximately 12 hours. After approximately 12 hours of thaw, initial falling head tests were performed. When the flow was significantly too fast or too slow, the analysis was stopped and the burette size was adjusted accordingly (i.e. a larger diameter burette was used for flows that were faster than desired or a smaller diameter burette was used for flows that were slower than desired). Two to four measurements were collected on each sample and collection stopped when the applied head load exceeded 25% change from the original load. Analyses were performed between 2 to 3 times for each sample. The final hydraulic conductivity calculations were computed using methodology of Das et al., 1985.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

A Novel Optical Instrument for On-Line Measurement of Particle Size Distribution—Application to Clean Coal Technologies

A flow cell is a critical measurement interface for many optical instruments. However, the flows are often sampled under harsh conditions, such as under high pressure and/or high temperature, in the presence of particles, moisture, vapors with high dew points or corrosive gases. Therefore, obtaining a high-optical-quality flow cell that does not perturb the measurement is a significant challenge. To address this challenge, we proposed a new flow cell that employs a unique laminar coaxial flow field (for the purge and sample flows). A test system was built to conduct particle size distribution (PSD) measurements with no sampling bias using a state-of-the-art analyzer (Malvern Panalytical Insitec). The results revealed that the measurement zone is well defined solely by the sample flow, and the optical windows are well protected by the purge flow, with minimal risk of any depositions from the sample flow. Using this flow cell, the Insitec can successfully measure PSD under high pressure and temperature under moist, corrosive conditions without generating any sampling bias. Importantly, we successfully applied this flow cell for on-line PSD measurement for the flue gas of a 100 kWth pressurized oxy-coal combustor operating at 15 bara.

Cheng, Mao (ORCID:0000000213273900)↗

Lamination of transparent conductive adhesives for tandem solar cell applications

A transparent conductive adhesive (TCA) interlayer for mechanically stacked multijunction solar cells provides adhesive strength and electrical connection between sub-cells when stacked. The fabrication of TCA sheets from an ethyl-vinyl acetate (EVA) matrix and silver coated compliant conductive microspheres, similar to industry-standard EVA encapsulant sheets, compatible with a standard lamination process was developed. Blade coating TCA sheets using 3D printed blades and testing of vertical conduction through the interlayer with a TCA conductivity jig allowed for reproducible measurements and low-cost fabrication. The supplemental information provides design files to enable other researchers to produce their own blades and testing jigs. We identified 0.5 mm as an optimal blade height for producing lab-scale TCA sheets and 120 °C at 3 psi for 10 min as the optimal vacuum lamination process to minimize resistance and possible damage to samples. For TCA sheets with coverages between 0.75% and 9%, the series resistance was approximately 0.2 O cm2 which should result in minimal losses for one-sun photovoltaic applications.

14 SOLAR ENERGY↗

Temperature Constraints on the Storage and Curation of Volatile-Rich Samples from the Lunar Poles

Final Document is attached. Introduction: NASA's Lunar Exploration Campaign includes Lunar sample return efforts beginning in the mid-2020's and human landed missions in the late 2020's-early 2030's. Volatile-rich samples from the Lunar poles will be high-priority targets due to their resource potential for human explorers and high science value. In order to precisely characterize the nature of these polar volatile materials upon return to Earth, they will need to be transported and curated under conditions that minimize their chemical and physical alteration. NASA Policy Directive (NPD) 7100.10F mandates the preservation of existing extraterrestrial samples with minimal alteration, extensive and quantitative documentation of alteration that is provided to investigators, and "the development of long-range plans" for samples yet to be acquired. This abstract summarizes new efforts by the Astromaterials Acquisition and Curation Office at JSC to assess the optimal

Mitchell, J. L.↗

Lifetime Extension Report: Progress on the SAVY-4000 Lifetime Extension Program

The 3-year accelerated aging study of the SAVY-4000 O-ring shows very little evidence of significant degradation to samples subjected to aggressive elevated temperature and radiation conditions. Whole container thermal aging studies followed by helium leakage testing and compression set measurements were used to establish an estimate for a failure criterion for O-ring compression set of ≥65 %. The whole container aging studies further show that the air flow and efficiency functions of the filter do not degrade significantly after thermal aging. However, the degradation of the water-resistant function leads to water penetration failure after four months at 210°C, but does not cause failure after 10 months at 120°C (130°C is the maximum operating temperature for the PTFE membrane). The thermal aging data for O-ring compression set do not meet the assumptions of standard time-temperature superposition analysis for accelerated aging studies. Instead, the data suggest that multiple degradation mechanisms are operative, with a reversible mechanism operative at low aging temperatures and an irreversible mechanism dominating at high aging temperatures. To distinguish between these mechanisms, we have measured compression set after allowing the sample to physically relax, thereby minimizing the effect of the reversible mechanism. The resulting data were analyzed using two distinct mathematical methods to obtain a lifetime estimate based on chemical degradation alone. Both methods support a lifetime estimate of greater than 150 years at 80°C. Although the role of the reversible mechanism is not fully understood, it is clear that the contribution to the total compression set is small in comparison to that due to the chemical degradation mechanism. To better understand the chemical degradation mechanism, thermally aged O-ring samples have been characterized by Fourier Transform Infrared (FTIR), Electron Paramagnetic Resonance (EPR), Gel Permeation Chromatography (GPC), and Differential Scanning Calorimetry (DSC). These experiments detect no significant O-ring degradation below 80°C. Furthermore, durometer measurements indicate that there is no significant change in O-ring hardness at all aging conditions examined. Therefore, our current conservative lifetime estimate for the O-ring and the filter is 10 years at 80°C. In FY17, we will continue to probe the chemical degradation mechanism using oxygen consumption measurements under accelerated aging conditions to reveal temperatures at which oxidation occurs, along with any differences in oxidation rate at the low vs. high aging temperatures. We will also refine the failure criteria and finalize the radiation/thermal synergistic studies to determine a final design lifetime.

42 ENGINEERING↗

A weighted ℓ{sub 1}-minimization approach for sparse polynomial chaos expansions

This work proposes a method for sparse polynomial chaos (PC) approximation of high-dimensional stochastic functions based on non-adapted random sampling. We modify the standard ℓ{sub 1}-minimization algorithm, originally proposed in the context of compressive sampling, using a priori information about the decay of the PC coefficients, when available, and refer to the resulting algorithm as weightedℓ{sub 1}-minimization. We provide conditions under which we may guarantee recovery using this weighted scheme. Numerical tests are used to compare the weighted and non-weighted methods for the recovery of solutions to two differential equations with high-dimensional random inputs: a boundary value problem with a random elliptic operator and a 2-D thermally driven cavity flow with random boundary condition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-503: Trajectory Modulated Arc Therapy of Intracranial Lesions: Development of a Standardized Path-Based Technique for Fully Dynamic Couch-Gantry Modulated Treatments

Purpose: The integration of couch motion during arc delivery is necessitated to enable irradiation trajectories such as coronal arcs, and to enhance the geometrical sampling for dynamic deliveries to the highest extent. To enable such capability, a platform of Trajectory Modulated Arc Therapy (TMAT) is developed in conjunction with standardized noncollisional dynamic path-set for irradiation of intracranial lesions. Methods: A generalized path-set was constructed through the combination of sagittal arcs (45 degrees from the CAX), axial arcs, and coronal arcs produced through modulation of the dynamic rotation of couch. The standardized path was implemented in a contiguous manner enabling the formation of fully automated sub-trajectories to provide maximal geometrical convergence with minimal number of arcs. Progressive sampling technique is used for direct aperture optimization of the MLCs and the selection of couch positions across the control points. Dosimetry of the resulting plans was assessed relative to clinically delivered plans. Using the TrueBeam Developer Mode, plan deliverability was tested. Results: Treatment planning of TMAT sub-trajectories for central, anterior and posterior tumor sites with volumes ranging from 4.75cc to 107cc demonstrated radically reduced doses to the critical OARs when compared to the clinically treated VMAT. Specifically, percentage reduction in mean dose for critical organs such as brainstem, cochlea, and optic nerve are found to be as low as 74±15%, 50±26% and 74±30% respectively as compared to VMAT. Conformity Index, defined as the ratio of tumor volume (VPTV) and 100% dose volume (V(D100%)), was reduced up to 12% while the Gradient Index, defined as V(D100%)/V(D50%), was concurrently improved by up to 14%. Conclusion: An automated standardized trajectory with dynamically modulated couch-gantry arcs has been developed for intracranial radiotherapy. Through the incorporation of coronal arcs, it is demonstrated that significantly reduced OAR doses can be achieved relative to clinically treated patient plans via VMAT. Research Grant Funding Support by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Inspection error and its adverse effects - A model with implications for practitioners

Inspection error has clearly been shown to have adverse effects upon the results desired from a quality assurance sampling plan. These effects upon performance measures have been well documented from a statistical point of view. However, little work has been presented to convince the QC manager of the unfavorable cost consequences resulting from inspection error. This paper develops a very general, yet easily used, mathematical cost model. The basic format of the well-known Guthrie-Johns model is used. However, it is modified as required to assess the effects of attributes sampling errors of the first and second kind. The economic results, under different yet realistic conditions, will no doubt be of interest to QC practitioners who face similar problems daily. Sampling inspection plans are optimized to minimize economic losses due to inspection error. Unfortunately, any error at all results in some economic loss which cannot be compensated for by sampling plan design; however, improvements over plans which neglect the presence of inspection error are possible. Implications for human performance betterment programs are apparent, as are trade-offs between sampling plan modification and inspection and training improvements economics.

Collins, R. D., Jr.↗

Low-rank matrix decomposition and spatio-temporal sparse recovery for STAP radar

We develop space-time adaptive processing (STAP) methods by leveraging the advantages of sparse signal processing techniques in order to detect a slowly-moving target. We observe that the inherent sparse characteristics of a STAP problem can be formulated as the low-rankness of clutter covariance matrix when compared to the total adaptive degrees-of-freedom, and also as the sparse interference spectrum on the spatio-temporal domain. By exploiting these sparse properties, we propose two approaches for estimating the interference covariance matrix. In the first approach, we consider a constrained matrix rank minimization problem (RMP) to decompose the sample covariance matrix into a low-rank positive semidefinite and a diagonal matrix. The solution of RMP is obtained by applying the trace minimization technique and the singular value decomposition with matrix shrinkage operator. Our second approach deals with the atomic norm minimization problem to recover the clutter response-vector that has a sparse support on the spatio-temporal plane. We use convex relaxation based standard sparse-recovery techniques to find the solutions. With extensive numerical examples, we demonstrate the performances of proposed STAP approaches with respect to both the ideal and practical scenarios, involving Doppler-ambiguous clutter ridges, spatial and temporal decorrelation effects. As a result, the low-rank matrix decomposition based solution requires secondary measurements as many as twice the clutter rank to attain a near-ideal STAP performance; whereas the spatio-temporal sparsity based approach needs a considerably small number of secondary data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical note: Optimizing the in situ cosmogenic 36 Cl extraction and measurement workflow for geologic applications

Abstract. In situ cosmogenic 36Cl analysis by accelerator mass spectrometry (AMS) is routinely employed to date Quaternary surfaces and assess rates of landscape evolution. However, standard laboratory preparation procedures for 36Cl dating require the addition of large amounts of isotopically enriched chlorine spike solution; these solutions are expensive and increasingly difficult to acquire from commercial sources. In addition, the typical workflow for 36Cl dating involves measuring both 35Cl/37Cl and 36Cl/Cl concurrently on the high-energy (post-accelerator) end of the AMS system, but 35Cl/37Cl determinations using this technique can be complicated by isotope fractionation and system memory during measurement. The traditional workflow also does not provide 36Cl extraction laboratories with the data needed to calculate native Cl concentrations in advance of 36Cl/Cl measurements. In light of these concerns, we present an improved workflow for extracting and measuring chlorine in geologic materials. Our initial step is to characterize 35Cl/37Cl on sample aliquots of up to ∼1 g prepared in Ag(Cl, Br) matrices, which greatly reduces the amount of isotopically enriched spike solution required to measure native Cl content in each sample. To avoid potential issues with isotope fractionation through the accelerator, 35Cl/37Cl is measured on the low-energy, pre-accelerator end of the AMS line. Then, for 36Cl/Cl measurements, we extract Cl as AgCl or Ag(Cl, Br) in analytical batches with a consistent total Cl load across all samples; this step is intended to minimize source memory effects during 36Cl/Cl measurements and allows the preparation of AMS standards that are customized to match known Cl contents in the samples. To assess the efficacy of this extraction and measurement workflow, we compare chlorine isotope ratio measurements on seven geologic samples prepared using standard procedures and the updated workflow. Measurements of 35Cl/37Cl and 36Cl/Cl are consistent between the two workflows, and 35Cl/37Cl values measured using our methods have considerably higher precision than those measured following standard protocols. The chemical preparation and measurement workflow presented here (1) reduces the amount of isotopically enriched chlorine spike used per rock sample by up to 95 %; (2) identifies rocks with high native Cl concentrations, which may be lower priority for 36Cl surface exposure dating, at an early stage of analysis; and (3) allows laboratory users to maintain control over the total chlorine content within and across analytical batches. These methods can be incorporated into existing laboratory and AMS protocols for 36Cl analyses and will increase the accessibility of 36Cl dating for geologic applications.

58 GEOSCIENCES↗

HO2 detection by near infrared absorption using tunable diode lasers

The strongest absorption lines are in the v sub 2 vibrational band around 1400/cm; several near-coincident line pairs in this region provide max linestrengths of 1.2 x 10 exp -20 sq. cm/(molecule*cm). High Frequency wavelength modulation coupled with sweep integration were used to minimize noise and maintain spectral discrimination. Reduced pressure sampling was performed using supersonic nozzle and an aerodynamic flow cell to minimize residence time and wall losses of radicals. The astigmatic mirror design provides pathlengths up to 200 m in volume of 3 liters with minimal optical interference fringes; longer pathlengths are possible. The detection limit depends on pathlength and minimum fractional absorptions.

Nelson, David↗

Determination of Aromatic Ring Number Using Multi-Channel Deep UV Native Fluorescence

The in situ detection of organic material on an extraterrestrial surface requires both effective means of searching a relatively large surface area or volume for possible organic carbon, and a more specific means of identifying and quantifying compounds in indicated samples. Fluorescence spectroscopy fits the first requirement well, as it can be carried out rapidly, with minimal or no physical contact with the sample, and with sensitivity unmatched by any other organic analytical technique. Aromatic organic compounds with know fluorescence signatures have been identified in several extraterrestrial samples, including carbonaceous chondrites, interplanetary dust particles, and Martian meteorites. The compound distributions vary among these sources, however, with clear differences in relative abundances by number of aromatic rings and by degree of alkylation. This relative abundance information, therefore, can be used to infer the source of organic material detected on a planetary surface.

Bhartia, R.↗

Mock-Up activities for the extraction of samples from a salt-stone disposal unit - 15502

Mock-up testing with respect to the core-drilling of simulant salt-stone grout was conducted to support the future retrieval of field-emplaced salt-stone samples from salt-stone Disposal Unit (SDU) Cell 2A. The primary objectives of extracting samples from SDU Cell 2A are to enable measurement of field-emplaced samples with respect to properties that influence long-term performance, such as saturated hydraulic conductivity, and to compare the measured properties for field-emplaced and comparable samples prepared in the laboratory. Initial mock-up activities (Phases 1 and 2) were conducted in Fiscal Years (FY) 2013 and 2014 in order to demonstrate the viability of standard core-drilling techniques that are typically employed for sampling concrete structures. The primary requirement for the core-drilling technique was that it should minimize the potential of physical or chemical sample changes that would artificially degrade key grout properties. Mock-up activities were aimed at optimizing the techniques for core-drilling, and subsequent sample extraction, using a set-up that mimicked, to the extent practical, both the physical characteristics, and operational complexities, of core-drilling salt-stone grout from the roof of the SDU. Samples extracted from the grout monolith were subsequently characterized with respect to saturated hydraulic conductivity and compressive strength, and compared to data for cast samples prepared using the same simulant salt-stone material. The comparison of these properties for the two sample types was expected to highlight potential flaws (e.g., micro-cracking) introduced by the core-drilling process. While the data for saturated hydraulic conductivity were virtually identical (approximately 2 E-09 cm/sec), the compressive strength of the core-drilled samples (approximately 3.5 MPa (500 psi)) was on average half that measured for the cast samples. It was suspected that increased water saturation and surface scoring of the core-drilled samples might account for the disparate compressive Strength data. During Phases 1 and 2 it was determined that cores could be successfully drilled and extracted to a depth of approximately 0.9 meters (3 feet) below the grout surface. Phase 3 (FY 2105) has been initiated and is primarily directed at demonstrating the ability to core-drill through approximately 1.8 meters (6 feet) of overlying grout to retrieve the desired sample from the SDU. The original drill depth of 0.6 - 0.9 meters (2-3 feet) was based on an SDU fill height of 5.6 meters (18.5 feet) and sample location of approximately 4.9 meters (16 feet); recently the allowable fill height in the SDUs has been increased to 6.5 meters (21.25 feet); hence the increased depth of overlying grout above the samples to be retrieved. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Balanced Fast-SpaciMS capillary configurations provide practically noninvasive channel-average measurements in catalytic monoliths

Spatially resolved capillary-inlet mass spectrometry (SpaciMS) provides a detailed picture of the spatiotemporal evolution of reaction network in catalytic monoliths. In the present work, we combine the SpaciMS experiments with a newly developed non-isothermal 3D CFD model for heterogeneously catalyzed reactive flows, including diffusion and permeation through the coated catalyst and channel wall. We explore how the capillary size and sampling rate can be balanced to minimize the impact on probed-channel conversions and provide species concentration measurements representative of the free channel average. In all studied configurations, the balanced sampling-rate fraction is noticeably higher than the corresponding capillary occlusion fraction. For a typical 350-micron capillary that occupies 11% of the channel cross- section, the balanced sampling rate represents 43% of the channel flow. Furthermore, the present work shows that together, a balanced SpaciMS configuration and numerical simulation provide accurate channel-averaged information of a monolithic catalyst under realistic operation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Seismic Velocities of the Tagish Lake Meteorite: Exploring Sample Size Limits for Elastic Property Determination

Understanding the mechanical and elastic properties of rocks comprising asteroids is be-coming of greater practical importance as more spacecraft interact with them (e.g. OSIRIS-REx, Hayabusa2, DART). However, knowledge of asteroid lithologies’ physical properties is limited due to sample paucity and the resulting challenges that come with working with small samples. Measuring seismic velocities is one way to directly and indirectly (through relation-ships established with analog materials) explore elastic and strength properties, respectively, while minimizing use of available material. While sample preparation requires cutting, the seismic measurements are non-destructive.

physical properties↗

Micro-balance sensor integrated with atomic layer deposition chamber

The invention is directed to QCM measurements in monitoring ALD processes. Previously, significant barriers remain in the ALD processes and accurate execution. To turn this exclusively dedicated in situ technique into a routine characterization method, an integral QCM fixture was developed. This new design is easily implemented on a variety of ALD tools, allows rapid sample exchange, prevents backside deposition, and minimizes both the footprint and flow disturbance. Unlike previous QCM designs, the fast thermal equilibration enables tasks such as temperature-dependent studies and ex situ sample exchange, further highlighting the feasibility of this QCM design for day-to-day use. Finally, the in situ mapping of thin film growth rates across the ALD reactor was demonstrated in a popular commercial tool operating in both continuous and quasi-static ALD modes.

42 ENGINEERING↗

The Determination of Pseudoscalar Meson Photoproduction Amplitudes from Complete Experiments

A new generation of complete experiments is currently underway with the goal of performing a high precision extraction of pseudoscalar meson photo-production amplitudes. Here we review the most general analytic form of the cross section, dependent upon the three polarization vectors of the beam, target and recoil baryon, including all single, double and triple-polarization terms involving 16 spin-dependent observables. Analytic expressions that determine the recoil baryon polarization are also presented. Different conventions are in use in the literature and we have used a numerical calculation of cross sections from Chew-Goldberger-Low-Nambu amplitudes with arbitrary spin projections to clarify apparent sign differences. As an illustration of the use of this machinery, we carry out a multipole analysis of the {gamma}p {yields} K{sup +}{Lambda} reaction and examine the impact of recently published polarization measurements. In fitting multipoles, we use a combined Monte Carlo sampling of the amplitude space, with gradient minimization, and find a shallow {chi}{sup 2} valley pitted with a very large number of local minima, despite the inclusion of recent data on 8 different observables. We conclude that, while a mathematical solution to the problem of determining an amplitude free of ambiguities may require 8 observables, as has been pointed out in the literature, experiments with realistically achievable uncertainties will require a significantly larger number.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗