Search NASA⌕ Search

SEARCH · Search NASA

Results for “segmentation averaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Multi-Scale Thermo-Mechanical Modeling of Porous 3D Woven TPS Materials

This work summarizes the process to compute and analyze the thermal conductivity and mechanical properties of 3D woven TPS materials such as 3MDCP (3D Mid-Density Carbon-Phenolic). The PuMA software, developed at NASA Ames, was used to characterize different 3MDCP samples from their constituents' data, averaging their thermal conductivity and elastic properties in the three main directions to obtain their effective orthotropic thermo-mechanical properties. This was performed in multiple steps: firstly, TPS samples were digitally reconstructed using micro computed tomography (µCT) and their constituents were segmented; then, the porous matrix phase was analyzed at the micro-scale and these results were used, along with the fibers’ constituents information, to model the tows at the meso-scale; finally, results from the constituents were homogenized and used to model the thermo-mechanical behavior of the unit cell at the macro-scale. Additionally, to gain a better understanding of the tows’ morphology and distribution of the carbon-phenolic blended fibers, microscopy images of the tows’ cross-section were segmented using deep learning techniques and analyzed with PuMA. This workflow can be applied to any TPS material to computationally obtain its thermo-mechanical properties, enabling more informed TPS design and manufacturing choices.

Multi-Scale↗

Linear Energy Transfer Painting With Proton Therapy: A Means of Reducing Radiation Doses With Equivalent Clinical Effectiveness

Purpose: The purpose of this study was to propose a proton treatment planning method that trades physical dose (D) for dose-averaged linear energy transfer (LET{sub d}) while keeping the radiobiologically weighted dose (D{sub RBE}) to the target the same. Methods and Materials: The target is painted with LET{sub d} by using 2, 4, and 7 fields aimed at the proximal segment of the target (split target planning [STP]). As the LET{sub d} within the target increases with increasing number of fields, D decreases to maintain the D{sub RBE} the same as the conventional treatment planning method by using beams treating the full target (full target planning [FTP]). Results: The LET{sub d} increased 61% for 2-field STP (2STP) compared to FTP, 72% for 4STP, and 82% for 7STP inside the target. This increase in LET{sub d} led to a decrease of D with 5.3 ± 0.6 Gy for 2STP, 4.4 ± 0.7 Gy for 4STP, and 5.3 ± 1.1 Gy for 7STP, keeping the DRBE at 90% of the volume (DRBE, 90) constant to FTP. Conclusions: LET{sub d} painting offers a method to reduce prescribed dose at no cost to the biological effectiveness of the treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-dimensional dose distributions of step-and-shoot IMRT delivered with real-time tumor tracking for patients with irregular breathing: Constant dose rate vs dose rate regulation

Purpose: Dose-rate-regulated tracking (DRRT) is a tumor tracking strategy that programs the MLC to track the tumor under regular breathing and adapts to breathing irregularities during delivery using dose rate regulation. Constant-dose-rate tracking (CDRT) is a strategy that dynamically repositions the beam to account for intrafractional 3D target motion according to real-time information of target location obtained from an independent position monitoring system. The purpose of this study is to illustrate the differences in the effectiveness and delivery accuracy between these two tracking methods in the presence of breathing irregularities. Methods: Step-and-shoot IMRT plans optimized at a reference phase were extended to remaining phases to generate 10-phased 4D-IMRT plans using segment aperture morphing (SAM) algorithm, where both tumor displacement and deformation were considered. A SAM-based 4D plan has been demonstrated to provide better plan quality than plans not considering target deformation. However, delivering such a plan requires preprogramming of the MLC aperture sequence. Deliveries of the 4D plans using DRRT and CDRT tracking approaches were simulated assuming the breathing period is either shorter or longer than the planning day, for 4 IMRT cases: two lung and two pancreatic cases with maximum GTV centroid motion greater than 1 cm were selected. In DRRT, dose rate was regulated to speed up or slow down delivery as needed such that each planned segment is delivered at the planned breathing phase. In CDRT, MLC is separately controlled to follow the tumor motion, but dose rate was kept constant. In addition to breathing period change, effect of breathing amplitude variation on target and critical tissue dose distribution is also evaluated. Results: Delivery of preprogrammed 4D plans by the CDRT method resulted in an average of 5% increase in target dose and noticeable increase in organs at risk (OAR) dose when patient breathing is either 10% faster or slower than the planning day. In contrast, DRRT method showed less than 1% reduction in target dose and no noticeable change in OAR dose under the same breathing period irregularities. When {+-}20% variation of target motion amplitude was present as breathing irregularity, the two delivery methods show compatible plan quality if the dose distribution of CDRT delivery is renormalized. Conclusions: Delivery of 4D-IMRT treatment plans, stemmed from 3D step-and-shoot IMRT and preprogrammed using SAM algorithm, is simulated for two dynamic MLC-based real-time tumor tracking strategies: with and without dose-rate regulation. Comparison of cumulative dose distribution indicates that the preprogrammed 4D plan is more accurately and efficiently conformed using the DRRT strategy, as it compensates the interplay between patient breathing irregularity and tracking delivery without compromising the segment-weight modulation.

60 APPLIED LIFE SCIENCES↗

3D printer generated thorax phantom with mobile tumor for radiation dosimetry

This article describes the design, construction, and properties of an anthropomorphic thorax phantom with a moving surrogate tumor. This novel phantom permits detection of dose both inside and outside a moving tumor and within the substitute lung tissue material. A 3D printer generated the thorax shell composed of a chest wall, spinal column, and posterior regions of the phantom. Images of a computed tomography scan of the thorax from a patient with lung cancer provided the template for the 3D printing. The plastic phantom is segmented into two materials representing the muscle and bones, and its geometry closely matches a patient. A surrogate spherical plastic tumor controlled by a 3D linear stage simulates a lung tumor’s trajectory during normal breathing. Sawdust emulates the lung tissue in terms of average and distribution in Hounsfield numbers. The sawdust also provides a forgiving medium that permits tumor motion and sandwiching of radiochromic film inside the mobile surrogate plastic tumor for dosimetry. A custom cork casing shields the film and tumor and eliminates film bending during extended scans. The phantom, lung tissue surrogate, and radiochromic film are exposed to a seven field plan based on an ECLIPSE plan for 6 MV photons from a Trilogy machine delivering 230 cGy to the isocenter. The dose collected in a sagittal plane is compared to the calculated plan. Gamma analysis finds 8.8% and 5.5% gamma failure rates for measurements of large amplitude trajectory and static measurements relative to the large amplitude plan, respectively. These particular gamma analysis results were achieved using parameters of 3% dose and 3 mm, for regions receiving doses >150 cGy. The plan assumes a stationary detection grid unlike the moving radiochromic film and tissues. This difference was experimentally observed and motivated calculated dose distributions that incorporated the phase of the tumor periodic motion. These calculations modestly improve agreement between the measured and intended doses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Switching dynamics and ultrafast inversion control of quantum dots for on-chip optical information processing

We demonstrate dynamical near-complete inversion switching of a two-level quantum dot driven by picosecond optical pulses in a bimodal photonic band gap (PBG) waveguide at microwatt power levels. This is enabled by a sharp steplike discontinuity in the local (electromagnetic) density of states (LDOS) provided by a cutoff in one of the two waveguide modes. The atomic Bloch vector equations in this colored vacuum are derived using dressed state description of the atomic density operator in the presence of phonon-mediated dephasing. Instead of assuming phenomenological decay rates, we derive explicit expressions for decay terms of bare state atomic dipole moments and population in the Born-Markov approximation from a master equation approach. Giant Mollow splitting of the atom level due to subwavelength light localization of strong driving pulse causes the time-dependent Mollow bands to straddle the LDOS jump, leading to different radiative decay rates in the upper and lower Mollow sidebands. This results in remarkable field-dependent spontaneous emission and dipolar dephasing rates, combined with a novel 'vacuum structure' term in the Bloch equations. Our Bloch equations predict ultrafast high-contrast inversion switching that is activated and deactivated by picosecond pulse trains detuned below and above the atomic resonance, respectively. This dynamic inversion is due to the rapid rise in relaxation rates as the pulse amplitude rises, causing the Bloch vector to switch from antiparallel to parallel alignment with the pulse 'torque vector'. Subsequent near-complete inversion occurs through an adiabatic following process retained long after the pulse amplitude subsides and the system reverts to slow relaxation. For a 1% inhomogeneously broadened distribution of quantum dot with average of 100 D dipole moment, driven by 1.5 mum picosecond pulses and coupled to a cutoff mode LDOS jump with radiative emission rates of gamma{sub high}=2.5 THz and gamma{sub low}=5 GHz, a large average population switching contrast of 0.5 is demonstrated with a phonon dephasing rate gamma{sub p}=0.5 THz. A 1.6 fJ control pulse is required per switching operation and a 30 muW pulse train is sufficient to maintain the inversion. This switchable gain (loss) segment of the PBG waveguide can be used to controllably amplify (absorb) signal pulses conveying optical information. This provides a robust mechanism for ultrafast multiwavelength channel all-optical logic in PBG microchips.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reinforcement Learning as a Parsimonious Alternative to Prediction Cascades: A Case Study on Image Segmentation

Deep learning architectures have achieved state-of-the-art (SOTA) performance on computer vision tasks such as object detection and image segmentation. This may be attributed to the use of over-parameterized, monolithic deep learning architectures executed on large datasets. Although such large architectures lead to increased accuracy, this is usually accompanied by a larger increase in computation and memory requirements during inference. While this is a non-issue in traditional machine learning (ML) pipelines, the recent confluence of machine learning and fields like the Internet of Things (IoT) has rendered such large architectures infeasible for execution in low-resource settings. For some datasets, large monolithic pipelines may be overkill for simpler inputs. To address this problem, previous efforts have proposed decision cascades where inputs are passed through models of increasing complexity until the desired performance is achieved. However, we argue that cascaded prediction leads to sub-optimal throughput and increased computational cost due to wasteful intermediate computations. To address this, we propose PaSeR (Parsimonious Segmentation with Reinforcement Learning) a non-cascading, cost-aware learning pipeline as an efficient alternative to cascaded decision architectures. Through experimental evaluation on both real-world and standard datasets, we demonstrate that PaSeR achieves better accuracy while minimizing computational cost relative to cascaded models. Further, we introduce a new metric IoU/GigaFlop to evaluate the balance between cost and performance. On the real-world task of battery material phase segmentation, PaSeR yields 179% improvement over SOTA MatPhase model and a 196% improvement over IDK Cascades under the IoU/GigaFlop metric. We also demonstrate PaSeR’s adaptability to complementary models trained on a noisy MNIST dataset, where it outperforms all baselines on IoU/GigaFlop by an average of 44%.

Srikshan, Bharat↗

Computation of three-dimensional shock-wave/turbulent boundary-layer interaction flows

Solutions of the Reynolds-averaged Navier-Stokes equations, employing a two-equation turbulence model, are presented and compared with measurements from a series of supersonic shock-wave/boundary-layer interaction experiments. The test flows include swept-compression corners and axisymmetric bodies with either skewed or segmented conical flares. The solutions correctly predict all major qualitative features of the flow field. However, for flow fields with large separated zones, significant quantitative differences are observed between the computed and experimental results. Possible reasons for these differences are discussed.

Horstman, C. C.↗

SU-E-T-614: Plan Averaging for Multi-Criteria Navigation of Step-And-Shoot IMRT

Purpose: Step-and-shoot IMRT is fundamentally discrete in nature, while multi-criteria optimization (MCO) is fundamentally continuous: the MCO planning consists of continuous sliding across the Pareto surface (the set of plans which represent the tradeoffs between organ-at-risk doses and target doses). In order to achieve close to real-time dose display during this sliding, it is desired that averaged plans share many of the same apertures as the pre-computed plans, since dose computation for apertures generated on-the-fly would be expensive. We propose a method to ensure that neighboring plans on a Pareto surface share many apertures. Methods: Our baseline step-and-shoot sequencing method is that of K. Engel (a method which minimizes the number of segments while guaranteeing the minimum number of monitor units), which we customize to sequence a set of Pareto optimal plans simultaneously. We also add an error tolerance to study the relationship between the number of shared apertures, the total number of apertures needed, and the quality of the fluence map re-creation. Results: We run tests for a 2D Pareto surface trading off rectum and bladder dose versus target coverage for a clinical prostate case. We find that if we enforce exact fluence map recreation, we are not able to achieve much sharing of apertures across plans. The total number of apertures for all seven beams and 4 plans without sharing is 217. With sharing and a 2% error tolerance, this number is reduced to 158 (73%). Conclusion: With the proposed method, total number of apertures can be decreased by 42% (averaging) with no increment of total MU, when an error tolerance of 5% is allowed. With this large amount of sharing, dose computations for averaged plans which occur during Pareto navigation will be much faster, leading to a real-time what-you-see-is-what-you-get Pareto navigation experience. Minghao Guo and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Route Optimization for Energy Efficient Airport Shuttle Operations - A Case Study from Dallas Fort Worth International Airport

Air travel and requisite surface traffic supporting passenger arrival/departure constitutes a significant portion of travel and emissions in cities with large airports. An airport trip can segment into three parts namely: i) travel from a location in the city to the airport; ii) travel from a parking lot or rental car center to the terminal (i.e., within the airport premises), and iii) travel inside the terminal. Depending on the airport access mode all or a part of these legs comprise a traveler’s journey to the airport. The priority of airport ground transport management teams is to provide passengers with a seamless travel experience within the airport, so it is understandable that within airport shuttle routes might not be optimized for minimizing energy consumption. Solutions that meet the dual objective of reducing energy consumption from airport shuttle operations without compromising on passenger travel experience are key to improving system efficiency. There is currently a dearth of research and tools that can inform airports in making such decisions. Addressing this need, this research effort puts forth an optimization model that generates optimal shuttle routes for a given set of constraints, and a discrete-event simulator that evaluates the optimal solutions in a stochastic environment to understand the tradeoffs between passenger wait times, and within airport shuttle energy consumption. The proposed set of tools are tested in the context of optimizing airport shuttles routes within the Dallas Fort Worth International Airport (DFW). In addition to shuttle spatial positioning, and passenger demand information, high-fidelity vehicle data was collected using data loggers installed on DFW shuttles. Results show that 20% energy reduction in shuttle operations is possible with a modest two-minute increase in average passenger wait times. The tools developed in this research effort are designed to be generalizable and can help optimize shuttle operations planning at any major airport.

air travel↗

Interactions among hydraulic conductivity distributions, subsurface topography, and transport thresholds revealed by a multitracer hillslope irrigation experiment

Interactions among hydraulic conductivity distributions, subsurface topography, and lateral flow are poorly understood. We applied 407 mm of water and a suite of tracers over 51 h to a 12 by 16.5 m forested hillslope segment to determine interflow thresholds, preferential pathway pore velocities, large-scale conductivities, the time series of event water fractions, and the fate of dissolved nutrients. The 12% hillslope featured loamy sand A and E horizons overlying a sandy clay loam Bt at 1.25 m average depth. Interflow measured from two drains within an interception trench commenced after 131 and 208 mm of irrigation. Cumulative interflow equaled 49% of applied water. Conservative tracer differences between the collection drains indicated differences in flow paths and storages within the plot. Event water fractions rose steadily throughout irrigation, peaking at 50% sixteen h after irrigation ceased. Data implied that tightly held water exchanged with event water throughout the experiment and a substantial portion of preevent water was released from the argillic layer. Surface-applied dye tracers bypassed the matrix, with peak concentrations measured shortly after flow commencement, indicating preferential network conductivities of 864–2240 mm/h, yet no macropore flow was observed. Near steady-state flow conditions indicated average conductivities of 460 mm/h and 2.5 mm/h for topsoils and the Bt horizon, respectively. Low ammonium and phosphorus concentrations in the interflow suggested rapid uptake or sorption, while higher nitrate concentrations suggested more conservative transport. Lastly, these results reveal how hydraulic conductivity variation and subsurface topographic complexity explain otherwise paradoxical solute and flow behaviors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Four-Dimensional Positron Emission Tomography: Implications for Dose Painting of High-Uptake Regions

Purpose: To investigate the behavior of tumor subvolumes of high [18F]-fluorodeoxyglucose (FDG) uptake as seen on clinical four-dimensional (4D) FDG-positron emission tomography (PET) scans. Methods and Materials: Four-dimensional FDG-PET/computed tomography scans from 13 patients taken before radiotherapy were available. The analysis was focused on regions of high uptake that are potential dose-painting targets. A total of 17 lesions (primary tumors and lymph nodes) were analyzed. On each one of the five phases of the 4D scan a classification algorithm was applied to obtain the region of highest uptake and segment the tumor volume. We looked at the behavior of both the high-uptake subvolume, called 'Boost,' and the segmented tumor volume, called 'Target.' We measured several quantities that characterize the Target and Boost volumes and quantified correlations between them. Results: The behavior of the Target could not always predict the behavior of the Boost. The shape deformation of the Boost regions was on average 133% higher than that of the Target. The gross to internal target volume expansion was on average 27.4% for the Target and 64% for the Boost, a statistically significant difference (p < 0.05). Finally, the inhale-to-exhale phase (20%) had the highest shape deformation for the Boost regions. Conclusions: A complex relationship between the measured quantities for the Boost and Target volumes is revealed. The results suggest that in cases in which advanced therapy techniques such as dose painting are being used, a close examination of the 4D PET scan should be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT

Purpose: High-speed nonrigid registration between the planning CT and the treatment CBCT data is critical for real time image guided radiotherapy (IGRT) to improve the dose distribution and to reduce the toxicity to adjacent organs. The authors propose a new fully automatic 3D registration framework that integrates object-based global and seed constraints with the grayscale-based ''demons'' algorithm. Methods: Clinical objects were segmented on the planning CT images and were utilized as meshless deformable models during the nonrigid registration process. The meshless models reinforced a global constraint in addition to the grayscale difference between CT and CBCT in order to maintain the shape and the volume of geometrically complex 3D objects during the registration. To expedite the registration process, the framework was stratified into hierarchies, and the authors used a frequency domain formulation to diffuse the displacement between the reference and the target in each hierarchy. Also during the registration of pelvis images, they replaced the air region inside the rectum with estimated pixel values from the surrounding rectal wall and introduced an additional seed constraint to robustly track and match the seeds implanted into the prostate. The proposed registration framework and algorithm were evaluated on 15 real prostate cancer patients. For each patient, prostate gland, seminal vesicle, bladder, and rectum were first segmented by a radiation oncologist on planning CT images for radiotherapy planning purpose. The same radiation oncologist also manually delineated the tumor volumes and critical anatomical structures in the corresponding CBCT images acquired at treatment. These delineated structures on the CBCT were only used as the ground truth for the quantitative validation, while structures on the planning CT were used both as the input to the registration method and the ground truth in validation. By registering the planning CT to the CBCT, a displacement map was generated. Segmented volumes in the CT images deformed using the displacement field were compared against the manual segmentations in the CBCT images to quantitatively measure the convergence of the shape and the volume. Other image features were also used to evaluate the overall performance of the registration. Results: The algorithm was able to complete the segmentation and registration process within 1 min, and the superimposed clinical objects achieved a volumetric similarity measure of over 90% between the reference and the registered data. Validation results also showed that the proposed registration could accurately trace the deformation inside the target volume with average errors of less than 1 mm. The method had a solid performance in registering the simulated images with up to 20 Hounsfield unit white noise added. Also, the side by side comparison with the original demons algorithm demonstrated its improved registration performance over the local pixel-based registration approaches. Conclusions: Given the strength and efficiency of the algorithm, the proposed method has significant clinical potential to accelerate and to improve the CBCT delineation and targets tracking in online IGRT applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-245: Sensitivity of FDG PET Feature Analysis in Multi-Plane Vs. Single-Plane Extraction

Purpose: Sensitivity of PET-derived texture features to reconstruction methods has been reported for features extracted from axial planes; however, studies often utilize three dimensional techniques. This work aims to quantify the impact of multi-plane (3D) vs. single-plane (2D) feature extraction on radiomics-based analysis, including sensitivity to reconstruction parameters and potential loss of spatial information. Methods: Twenty-three patients with solid tumors underwent [{sup 18}F]FDG PET/CT scans under identical protocols. PET data were reconstructed using five sets of reconstruction parameters. Tumors were segmented using an automatic, in-house algorithm robust to reconstruction variations. 50 texture features were extracted using two Methods: 2D patches along axial planes and 3D patches. For each method, sensitivity of features to reconstruction parameters was calculated as percent difference relative to the average value across reconstructions. Correlations between feature values were compared when using 2D and 3D extraction. Results: 21/50 features showed significantly different sensitivity to reconstruction parameters when extracted in 2D vs 3D (wilcoxon α<0.05), assessed by overall range of variation, Rangevar(%). Eleven showed greater sensitivity to reconstruction in 2D extraction, primarily first-order and co-occurrence features (average Rangevar increase 83%). The remaining ten showed higher variation in 3D extraction (average Range{sub var}increase 27%), mainly co-occurence and greylevel run-length features. Correlation of feature value extracted in 2D and feature value extracted in 3D was poor (R<0.5) in 12/50 features, including eight co-occurrence features. Feature-to-feature correlations in 2D were marginally higher than 3D, ∣R∣>0.8 in 16% and 13% of all feature combinations, respectively. Larger sensitivity to reconstruction parameters were seen for inter-feature correlation in 2D(σ=6%) than 3D (σ<1%) extraction. Conclusion: Sensitivity and correlation of various texture features were shown to significantly differ between 2D and 3D extraction. Additionally, inter-feature correlations were more sensitive to reconstruction variation using single-plane extraction. This work highlights a need for standardized feature extraction/selection techniques in radiomics.

60 APPLIED LIFE SCIENCES↗

Assessment of Mechanical Draft Cooling Tower Thermal Emissions from Visual Images of Plumes

Using a one-dimensional code, we computed the power (enthalpy discharge rate) of a twelve-cell mechanical draft cooling tower (MDCT) using over two hundred visible condensed water vapor plume volume measurements derived from images, weather data, and tower operating conditions. The plume images were simultaneously captured by multiple stationary digital cameras surrounding the cooling tower. An analysis technique combining structure from motion (SfM), a neural-network-based image segmentation algorithm, and space carving was used to quantify the volumes. Afterwards, the power output was computed using novel techniques in the one-dimensional code that included cooling tower exhaust plume adjacency effects implemented with a modified version of the entrainment function, weather data averaged from eleven stations, and fan operations at the times when plume volumes were measured. The model was then compared with the averaged observed power output, and it validated well with an average error ranging from 6 to 12%, depending on the meteorological data used in the simulations. This methodology can possibly determine power plant fuel consumption rates by applying visible imagery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Canberra's Tomographic Gamma-Ray Can Scanner ('Can-TGS') - 13311

The Tomographic Gamma-ray Scanner (TGS) for large volume drummed waste has been successfully commercialized by Canberra over the last several years. As part of an R and D effort to continually improve this technology, we have developed a scaled down version of the standard commercial product (Can-TGS). The Can-TGS is able to accommodate cans and pails of various sizes, ranging from sub-liter to 20 liter volumes with densities of up to 4 g/cc. The Can-TGS has three diamond-shaped collimators (6.35 mm [0.25''], 12.7 mm [0.5''], and 25.4 mm [1'']) to facilitate a range of container volumes and heights. As with the standard TGS, the Can-TGS has a transmission source sub-system, where the transmission source can be easily swapped between sources of various strengths and type. The acquisition portion of the Can-TGS is powered by the Canberra Lynx{sup R} MCA which accommodates both multi-spectral scaling (MSS) and list-mode. Recently, the Can-TGS has been successfully characterized for an 18.93 L [5-gallon] container for the 25.4 mm diamond-shaped collimator. In principle, a single measurement (with good statistics) is required for each configuration in order to characterize the system. However, for this study, measurements were performed for several different matrices. For each matrix used, 6 different measurements were acquired. For each of these measurements, the drum was rotated 60 deg. with respect to the previous starting position. This procedure was followed in order to average out any radial bias that might be produced from just a single measurement. A description of the Can-TGS system is given. The details of the recent characterization measurements and the associated data analysis and results are presented. TGS results are compared with Segmented Gamma Scanner (SGS) results for the same source configuration. Additionally, the future outlook for Canberra's R and D efforts with this system is discussed. These efforts include TGS algorithm optimization, improving our understanding of the uncertainties associated with TGS results, and the overall benefits and limitations of this technology as compared to other available non-destructive assay techniques. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metrics of Balance Control for Use in Screening Tests of Vestibular Function

Decrements in balance control have been documented in astronauts after space flight. Reliable measures of balance control are needed for use in postflight field tests at remote landing sites. Diffusion analysis (DA) is a statistical mechanical tool that shows the average difference of the dependent variable on varying time scales. These techniques have been shown to measure differences in open-loop and closed-loop postural control in astronauts and elderly subjects. The goal of this study was to investigate the reliability of these measures of balance control. Eleven subjects were tested using the Clinical Test of Sensory Interaction on Balance: the subject stood with feet together and arms crossed on a stable or compliant surface, with eyes open or closed and with or without head movements in the pitch or yaw plane. Subjects were instrumented with inertial motion sensors attached to their trunk segment. The DA curves for linear acceleration measures were characterized by linear fits measuring open- (Ds) and closed-loop (Dl) control, and their intersection point (X-int, Y-int). Ds and Y-int showed significant differences between the test conditions. Additionally, Ds was correlated with the root mean square (RMS) of the signal, indicating that RMS was dominated by open-loop events (< 0.5 seconds). The Y-int was found to be correlated with the average linear velocity of trunk movements. Thus DA measures could be applied to derive reliable metrics of balance stability during field tests.

Fiedler, Matthew↗

Deterministic direct aperture optimization using multiphase piecewise constant segmentation

Purpose Direct aperture optimization (DAO) attempts to incorporate machine constraints in the inverse optimization to eliminate the post‐processing steps in fluence map optimization (FMO) that degrade plan quality. Current commercial DAO methods utilize a stochastic or greedy approach to search a small aperture solution space. In this study, we propose a novel deterministic direct aperture optimization that integrates the segmentation of fluence map in the optimization problem using the multiphase piecewise constant Mumford‐Shah formulation. Methods The Mumford‐Shah based direct aperture optimization problem was formulated to include an L2‐norm dose fidelity term to penalize differences between the projected dose and the prescribed dose, an anisotropic total variation term to promote piecewise continuity in the fluence maps, and the multiphase piecewise constant Mumford‐Shah function to partition the fluence into pairwise discrete segments. A proximal‐class, first‐order primal‐dual solver was implemented to solve the large scale optimization problem, and an alternating module strategy was implemented to update fluence and delivery segments. Three patients of varying complexity—one glioblastoma multiforme (GBM) patient, one lung (LNG) patient, and one bilateral head and neck (H&N) patient with 3 PTVs—were selected to test the new DAO method. For each patient, 20 non‐coplanar beams were first selected using column generation, followed by the Mumford‐Shah based DAO (DAO MS ). For comparison, a popular and successful approach to DAO known as simulated annealing—a stochastic approach—was replicated. The simulated annealing DAO (DAO SA ) plans were then created using the same beam angles and maximum number of segments per beam. PTV coverage, PTV homogeneity , and OAR sparing were assessed for each plan. In addition, high dose spillage, defined as the 50% isodose volume divided by the tumor volume, as well as conformity, defined as the van't Riet conformation number, were evaluated. Results DAO MS achieved essentially the same OAR doses compared with the DAO SA plans for the GBM case. The average difference of OAR D max and D mean between the two plans were within 0.05% of the plan prescription dose. The lung case showed slightly improved critical structure sparing using the DAO MS approach, where the average OAR D max and D mean were reduced by 3.67% and 1.08%, respectively, of the prescription dose. The DAO MS plan substantially improved OAR dose sparing for the H&N patient, where the average OAR D max and D mean were reduced by over 10% of the prescription dose. The DAO MS and DAO SA plans were comparable for the GBM and LNG PTV coverage, while the DAO MS plan substantially improved the H&N PTV coverage, increasing D99 by 6.98% of the prescription dose. For the GBM and LNG patients, the DAO MS and DAO SA plans had comparable high dose spillage but slightly worse conformity with the DAO MS approach. For the H&N plan, DAO MS was considerably superior in high dose spillage and conformity to the DAO SA . The deterministic approach is able to solve the DAO problem substantially faster than the simulated annealing approach, with a 9.5‐ to 40‐fold decrease in total solve time, depending on the patient case. Conclusions A novel deterministic direct aperture optimization formulation was developed and evaluated. It combines fluence map optimization and the multiphase piecewise constant Mumford‐Shah segmentation into a unified framework, and the resulting optimization problem can be solved efficiently. Compared to the widely and commercially used simulated annealing DAO approach, it showed comparable dosimetry behavior for simple plans, and substantially improved OAR sparing, PTV coverage, PTV homogeneity, high dose spillage, and conformity for the more complex head and neck plan.

Nguyen, Dan↗

From observation to replication: machine-learning-driven quantification and replication of fine-scale fish kinematics and behavior

Long-term quantification of fish behavior is essential for aquatic ecology, wildlife telemetry, and biomechanical device development. However, the observation duration required to obtain reliable behavioral and kinematic metrics remains unclear, and few tools exist to physically reproduce natural swimming motion for controlled experimentation. We address these challenges by developing a generalizable framework that models behavioral reliability (Spearman–Brown reliability index) as a function of observation duration and derives metric-specific monitoring thresholds. Using juvenile white sturgeon (Acipenser transmontanus) as a case study, we demonstrate that the minimum duration needed for reliable estimates varies substantially across kinematic features: to exceed a reliability of 0.8, total distance traveled requires 12 days, average curvature (mm?¹) 15 days, tail-beat frequency (Hz) 8 days, and average speed (body length/s) 17 days. We further bridge digital analysis and physical testing by developing a hardware-in-the-loop simulator that reconstructs machine-learning-derived swimming kinematics with high fidelity (correlation coefficient 0.98–0.99, RMSE 1.22–1.27 mm over a 5-minute segment). This platform enables realistic, repeatable motion stimuli for evaluating aquatic sensing technologies and bio-integrated devices under controlled conditions. Together, these contributions provide a scalable approach for designing long-term behavioral studies and a data-driven connection between ecological observation and robotic experimentation.

Hwang, SungJoo↗