Search NASA⌕ Search

SEARCH · Search NASA

Results for “software optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

DNA Sequencing Optimizer v0.1

This is a software utility used to maximize next-generation sequencing data output without compromising quality values. The DNA Sequencing Optimizer is used to determine the optimal amount of library to load. To do this a supervised machine learning model predicts cluster density, a measure of how much DNA is bound to the sequence, from the concentration of DNA loaded. The output is a plot that is used by experimentalists to determine the best DNA library concentration to load onto the sequencer.

Costello, Zachary↗

Magnetohydrodynamics with physics informed neural operators

Abstract The modeling of multi-scale and multi-physics complex systems typically involves the use of scientific software that can optimally leverage extreme scale computing. Despite major developments in recent years, these simulations continue to be computationally intensive and time consuming. Here we explore the use of AI to accelerate the modeling of complex systems at a fraction of the computational cost of classical methods, and present the first application of physics informed neural operators (NOs) (PINOs) to model 2D incompressible magnetohydrodynamics (MHD) simulations. Our AI models incorporate tensor Fourier NOs as their backbone, which we implemented with the TensorLY package. Our results indicate that PINOs can accurately capture the physics of MHD simulations that describe laminar flows with Reynolds numbers Re ⩽ 250 . We also explore the applicability of our AI surrogates for turbulent flows, and discuss a variety of methodologies that may be incorporated in future work to create AI models that provide a computationally efficient and high fidelity description of MHD simulations for a broad range of Reynolds numbers. The scientific software developed in this project is released with this manuscript.

97 MATHEMATICS AND COMPUTING↗

TURBOMOLE: Modular program suite for ab initio quantum-chemical and condensed-matter simulations

TURBOMOLE is a collaborative, multi-national software development project aiming to provide highly efficient and stable computational tools for quantum chemical simulations of molecules, clusters, periodic systems, and solutions. The TURBOMOLE software suite is optimized for widely available, inexpensive, and resource-efficient hardware such as multi-core workstations and small computer clusters. TURBOMOLE specializes in electronic structure methods with outstanding accuracy–cost ratio, such as density functional theory including local hybrids and the random phase approximation (RPA), GW-Bethe–Salpeter methods, second-order Møller–Plesset theory, and explicitly correlated coupled-cluster methods. TURBOMOLE is based on Gaussian basis sets and has been pivotal for the development of many fast and low-scaling algorithms in the past three decades, such as integral-direct methods, fast multipole methods, the resolution-of-the-identity approximation, imaginary frequency integration, Laplace transform, and pair natural orbital methods. This review focuses on recent additions to TURBOMOLE’s functionality, including excited-state methods, RPA and Green’s function methods, relativistic approaches, high-order molecular properties, solvation effects, and periodic systems. A variety of illustrative applications along with accuracy and timing data are discussed. Moreover, available interfaces to users as well as other software are summarized. TURBOMOLE’s current licensing, distribution, and support model are discussed, and an overview of TURBOMOLE’s development workflow is provided. Challenges such as communication and outreach, software infrastructure, and funding are highlighted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Design for Hanford Low-Activity Waste Glasses with High Waste Loading

This report discusses the development of an experimental design for the initial phase of the Hanford low-activity waste (LAW) enhanced glass study. This report is based on a manuscript written for an applied statistics journal. Appendices A, B, and E include additional information relevant to the LAW enhanced glass experimental design that is not included in the journal manuscript. The glass composition experimental region is defined by single-component constraints (SCCs), linear multiple-component constraints (MCCs), and a nonlinear MCC involving 15 LAW glass components. Traditional methods and software for designing constrained mixture experiments with SCCs and linear MCCs are not directly applicable because of the nonlinear MCC. A modification of existing methodology to account for the nonlinear MCC was developed and is described in this report. One of the glass components, SO 3 , has a solubility limit in glass that depends on the composition of the balance of the glass. A goal was to design the experiment so that SO 3 would not exceed its predicted solubility limit for any of the experimental glasses. The SO 3 solubility limit had previously been modeled by a partial quadratic mixture model expressed in the relative proportions of the 14 other components. The partial quadratic mixture model was used to construct a nonlinear MCC in terms of all 15 components. In addition, there were SCCs and linear MCCs. This report describes how a layered design was generated to (i) account for the SCCs, linear MCCs, and nonlinear MCC and (ii) meet the goals of the study. A layered design consists of points on an outer layer, and inner layer, and a center point. There were 18 outer-layer glasses chosen using optimal experimental design software to augment 147 existing glass compositions that were within the LAW glass composition experimental region. Then 13 inner-layer glasses were chosen with the software to augment the existing and outer-layer glasses. The experimental design was completed by a center-point glass, a Vitreous State Laboratory glass, and replicates of the center point and Vitreous State Laboratory glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Data-Driven Solution for Performance Improvement

Marketed as the "Software of the Future," Optimal Engineering Systems P.I. EXPERT(TM) technology offers statistical process control and optimization techniques that are critical to businesses looking to restructure or accelerate operations in order to gain a competitive edge. Kennedy Space Center granted Optimal Engineering Systems the funding and aid necessary to develop a prototype of the process monitoring and improvement software. Completion of this prototype demonstrated that it was possible to integrate traditional statistical quality assurance tools with robust optimization techniques in a user- friendly format that is visually compelling. Using an expert system knowledge base, the software allows the user to determine objectives, capture constraints and out-of-control processes, predict results, and compute optimal process settings.

Source record↗

Battery Thermal Characterization

A well-designed thermal management system is critical to the life and performance of electric-drive vehicles (EDVs) hybrids (HEVs), plug-in hybrids (PHEVs), and all-electric vehicles (EVs). Temperature and temperature uniformity both significantly affect the performance, lifespan, and safety of vehicle energy storage devices. NREL conducts thermal management research and development (R&D) to optimize battery performance and extend useful life. A recognized leader in battery thermal analysis and characterization, NREL evaluates electrical and thermal performance of battery cells, modules, and packs, full energy storage systems, and the interaction of these systems with other vehicle components. The lab's performance assessments factor in the design of the thermal management system, the thermal behavior of the cell, battery lifespan, and safety of the energy storage system, as well as full integration into a vehicle. The lithium-ion (Li-ion) batteries found in most of today's electric-drive vehicles are smaller and more lightweight than previous nickel-metal hydride (NiMH) technology, but they are also more sensitive to overheating, overcharging, and extreme spikes in temperature known as thermal runaway. High temperatures diminish battery life and increase battery replacement costs, while low temperatures decrease battery power and capacity, all of which impact vehicle range, performance, and affordability. NREL's breakthrough research is focused on reducing thermal barriers to achieve more uniform temperatures. NREL uses its R&D 100 Award-winning Isothermal Battery Calorimeters, the only instruments in the world capable of such precise thermal measurements, for much of this research. Calorimeter readings are paired with thermal imaging of batteries using infrared cameras to evaluate battery temperature distribution. In addition, NREL is working with industry to develop computer-aided engineering software tools to optimize thermal management of batteries. NREL's analysis for the U.S. Advanced Battery Consortium (USABC) show that optimized thermal management can increase battery power by more than 10%. Without proper thermal management, an EDV battery can last more than 10 years in a temperate climate, like in Minnesota, but only 7 years in a hot climate, such as in Arizona. In extreme instances, battery overheating can pose safety hazards, including fires. Performance: Maintaining desired temperature ranges is critical in optimizing EDV battery storage capacity, lifespan, and performance, and eventually impacts cost and consumer acceptance. NREL's breakthrough research focuses on achieving more uniform temperatures while a vehicle is in motion and actively generating heat, as well as when it is parked and exposed to ambient temperatures over prolonged periods of time. Safety: Most energy storage systems deliver maximum performance at higher temperatures. However, this extreme heat can overload systems and create dangerous conditions. NREL evaluation helps to more effectively regulate thermal characteristics, providing greater safeguards and stronger performance. NREL has invented a device that emulates internal short circuits in batteries to better understand how to prevent future failures and related hazards.

25 ENERGY STORAGE↗

Schedule Management Optimization (SMO) Domain Model (V.1.2)

Schedule Management Optimization (SMO) is a tool for automatically generating a schedule of project tasks. Project scheduling is traditionally achieved with the use of commercial project management software or case-specific optimization formulations. Commercial software packages are useful tools for managing and visualizing copious amounts of project task data. However, their ability to automatically generate optimized schedules is limited. Furthermore, there are many real-world constraints and decision variables that commercial packages ignore. Case-specific optimization formulations effectively identify schedules that optimize one or more objectives for a specific problem, but they are unable to handle a diverse selection of scheduling problems. SMO enables practitioners to generate optimal project schedules automatically while considering a broad range of real-world problem characteristics. SMO has been designed to handle some of the most difficult scheduling problems – those with resource constraints, multiple objectives, multiple inventories, and diverse ways of performing tasks. This report contains descriptions of the SMO modeling concepts and explains how they map to real-world scheduling considerations.

97 MATHEMATICS AND COMPUTING↗

CAASCADE: A System for Static Analysis of HPC Software Application Portfolios

With the increasing complexity of upcoming HPC systems, so-called “co-design” efforts to develop the hardware and applications in concert for these systems also become more challenging. It is currently difficult to gather information about the usage of programming model features, libraries, and data structure considerations in a quantitative way across a variety of applications, and this information is needed to prioritize development efforts in systems software and hardware optimizations. In this paper we propose CAASCADE, a system that can harvest this information in an automatic way in production HPC environments, and we show some early results from a prototype of the system based on GNU compilers and a MySQL database.

Lopez, Graham↗

Microstructural characterization and influence of manufacturing parameters on technological properties of vitreous ceramic materials

Microstructure of vitreous ceramic samples manufactured from kaolinitic-clay and feldspars raw materials from Cameroon was investigated in the range 1150-1250 deg. C by X-ray diffraction and scanning electron microscopy and by measuring some technological properties. Moreover, the simultaneous influence of feldspars content, heating temperature and soaking time on water absorption and firing shrinkage was evaluated by adopting the response surface methodology (Doehlert matrix), using the New Efficient Methodology for Research using Optimal Design (NEMROD) software. The results show that a spinel phase, mullite, glassy phase and some amount of hematite were formed. However, the spinel phase and potassic feldspar, as compared to the sodic one, disappeared at moderate firing temperature and soaking time. Apparently, mullite developed from spinel phase, which is formed from the demixion of metakaolin. On the other hand, it is found that the effects of fluxing content and firing temperature on the measured properties were almost similar and more influent than soaking time. Antagonistic and synergetic interactions existed between the considered parameters, and their importance differed for the considered properties. By using this mathematical tool, suitable operating conditions for manufacturing vitreous bodies were determined.

36 MATERIALS SCIENCE↗

Optimization of the Coupled Cluster Implementation in NWChem on Petascale Parallel Architectures

Coupled cluster singles and doubles (CCSD) algorithm has been optimized in NWChem software package. This modification alleviated the communication bottleneck and provided from 2- to 5-fold speedup in the CCSD iteration time depending on the problem size and available memory. Sustained 0.60 petaflop/sec performance on CCSD(T) calculation has been obtained on NCSA Blue Waters. This number included all stages of the calculation from initialization till termination, iterative computation of single and double excitations, and perturbative accounting for triple excitations. In the section of perturbative triples alone, the computation maintained 1.18 petaflop/sec performance level. CCSD computations have been performed on Guanine-Cytosine deoxydinucleotide monophosphate (GC-dDMP) to probe the conformational energy difference in DNA single strand in A- and B-conformations. The computation revealed significant discrepancy between CCSD and classical force fields in prediction of relative energy of A- and B-conformations of GC-dDMP.

calculations↗

Modular droplet injector for sample conservation providing new structural insight for the conformational heterogeneity in the disease-associated NQO1 enzyme

Droplet injection strategies are a promising tool to reduce the large amount of sample consumed in serial femtosecond crystallography (SFX) measurements at X-ray free electron lasers (XFELs) with continuous injection approaches. Here, we demonstrate a new modular microfluidic droplet injector (MDI) design that was successfully applied to deliver microcrystals of the human NAD(P)H:quinone oxidoreductase 1 (NQO1) and phycocyanin. We investigated droplet generation conditions through electrical stimulation for both protein samples and implemented hardware and software components for optimized crystal injection at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Stanford Linac Coherent Light Source (LCLS). Under optimized droplet injection conditions, we demonstrate that up to 4-fold sample consumption savings can be achieved with the droplet injector. In addition, we collected a full data set with droplet injection for NQO1 protein crystals with a resolution up to 2.7 Å, leading to the first room-temperature structure of NQO1 at an XFEL. NQO1 is a flavoenzyme associated with cancer, Alzheimer's and Parkinson's disease, making it an attractive target for drug discovery. Further, our results reveal for the first time that residues Tyr128 and Phe232, which play key roles in the function of the protein, show an unexpected conformational heterogeneity at room temperature within the crystals. These results suggest that different substates exist in the conformational ensemble of NQO1 with functional and mechanistic implications for the enzyme's negative cooperativity through a conformational selection mechanism. Our study thus demonstrates that microfluidic droplet injection constitutes a robust sample-conserving injection method for SFX studies on protein crystals that are difficult to obtain in amounts necessary for continuous injection, including the large sample quantities required for time-resolved mix-and-inject studies.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of rabbit eardrum vibration through stroboscopic digital holography

In this work, we present a setup for high-power single shot stroboscopic digital holography and demonstrate it in an application on rabbit eardrum vibration measurement. The setup is able to make full-field time-resolved measurements of vibrating surfaces with a precision in the nanometer range in a broad frequency range. The height displacement of the measured object is visualized over the entire surface as a function of time. Vibration magnitude and phase maps can be extracted from these data, the latter proving to be very useful to reveal phase delays across the surface. Such deviations from modal motion indicate energy losses due to internal damping, in contrast to purely elastic mechanics. This is of great interest in middle ear mechanics and finite element modelling. In our setup, short laser pulses are fired at selected instants within the surface vibration period and are recorded by a CCD camera. The timing of the pulses and the exposure of the camera are synchronized to the vibration phase by a microprocessor. The high-power frequency-doubled Nd:YAG laser produces pulses containing up to 5 mJ of energy, which is amply sufficient to record single-shot holograms. As the laser pulse length is 8 ns and the smallest time step of the trigger electronics is 1 μs, vibration measurements of frequencies up to 250 kHz are achievable through this method, provided that the maximum vibration amplitude exceeds a few nanometers. In our application, middle ear mechanics, measuring frequencies extend from 5 Hz to 20 kHz. The experimental setup will be presented, as well as results of measurements on a stretched circular rubber membrane and a rabbit's eardrum. Two of the challenges when measuring biological tissues, such as the eardrum, are low reflectivity and fast dehydration. To increase reflectivity, a coating is applied and to counteract the undesirable effects of tissue dehydration, the measurement setup and software have been optimized for speed without compromising on the quality. Results of a repeatability test will be presented as well. Since the method measures the membrane motion as a function of time in small time steps, we do not only measure vibration amplitude like in time-average holography, but we can also measure non-linear elastic and transient behaviour. In conclusion, the combination of good spatial, depth and time resolution with the fast data acquisition and very wide frequency range make our technique applicable in a number of fields, including biological tissue vibrations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CASSIS: THE CORNELL ATLAS OF SPITZER/INFRARED SPECTROGRAPH SOURCES

We present the spectral atlas of sources observed in low resolution with the Infrared Spectrograph on board the Spitzer Space Telescope. More than 11,000 distinct sources were extracted using a dedicated algorithm based on the SMART software with an optimal extraction (AdOpt package). These correspond to all 13,000 low-resolution observations of fixed objects (both single source and cluster observations). The pipeline includes image cleaning, individual exposure combination, and background subtraction. Particular attention is given to bad pixel and outlier rejection at the image and spectra levels. Most sources are spatially unresolved so that optimal extraction reaches the highest possible signal-to-noise ratio. For all sources, an alternative extraction is also provided that accounts for all of the source flux within the aperture. CASSIS provides publishable quality spectra through an online database together with several important diagnostics, such as the source spatial extent and a quantitative measure of detection level. Ancillary data such as available spectroscopic redshifts are also provided. The database interface will eventually provide various ways to interact with the spectra, such as on-the-fly measurements of spectral features or comparisons among spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculation of Critical Heat Flux Using an Inverse Heat Transfer Method to Support TREAT Experiment Analysis

Heat transfer between cladding and coolant during transient scenarios remains a critical area of uncertainty in understanding nuclear reactor safety. To advance the understanding of transient and accident scenarios involving critical heat flux (CHF), an in-pile experiment for the Transient Reactor Test (TREAT) facility at Idaho National Laboratory was developed. The experiment named CHF-Static Environment Rodlet Transient Test Apparatus (CHF-SERTTA), consists of a hollow borated stainless steel heater rod submerged in a static water pool which is heated via the (n, a) reaction in boron-10. This paper presents a novel inverse heat transfer method to determine CHF by using the optimization and uncertainty software DAKOTA to calibrate a RELAP5-3D model of CHF-SERTTA to temperature measurements obtained from a thermocouple welded to the surface of the rod.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-248: Near Real-Time Analysis of Radiation Delivery and Imaging, Accuracy to Ensure Patient Safety

Purpose: To develop and optimize an effective software method for comparing planned to delivered control point machine parameters for all VARIAN TrueBeam treatments so as to permit (1) assessment of a large patient pool throughout their treatment course to quantify treatment technique specific systematic and random uncertainty of observables, (2) quantify the site specific daily imaging shifts required for target alignment, and (3) define tolerance levels for mechanical parameters and imaging parameters based on statistical analysis data gathered, and the dosimetric impact of variations. Methods: Treatment and imaging log files were directly compared to plan parameters for Eclipse and Pinnacle planned treatments via 3D, IMRT, control point, RapidArc, and electrons. Each control point from all beams/arcs (7984) for all fractions (1940) of all patients treated over six months were analyzed. At each control point gantry angle, collimator angle, couch angle, jaw positions, MLC positions, MU were compared. Additionally per-treatment isocenter shifts were calculated. Results were analyzed as a whole in treatment type subsets: IMRT, 3D, RapidArc; and in treatment site subsets: brain, chest/mediastinum, esophagus, H and N, lung, pelvis, prostate. Results: Daily imaging isocenter shifts from initial external tattoo alignment were dependent on the treatment site with < 0.5 cm translational shifts for H and N, Brain, and lung SBRT, while pelvis, esophagus shifts were ∼1 cm. Mechanical delivery parameters were within tolerance levels for all sub-beams. The largest variations were for RapidArc plans: gantry angle 0.11±0.12,collimator angle 0.00±0.00, jaw positions 0.48±0.26, MLC leaf positions 0.66±0.08, MU 0.14±0.34. Conclusion: Per-control point validation reveals deviations between planned and delivered parameters. If used in a near real-time error checking system, patient safety can be improved by equipping the treatment delivery system with additional forcing functions which by-pass human error avenues.

60 APPLIED LIFE SCIENCES↗

SU-F-T-416: Dosimetric Comparison of Coplanar and Non-Coplanar IMRT Plans for Peripheral Lung Lesion

Purpose: The purpose of this study was to compare dosimetric parameters of treatment plans between coplanar and non-coplanar techniques for treating peripheral lung lesions. Methods: The planning CT scans of 6 patients in supine positions were used in this study. The size of the PTV ranges from 163 c.c. to 782 c.c.. The locations of PTV are mostly at the peripheral of Lung, some spreading to the mediastinum. For each patient, we generated two IMRT plans, one with and the other without non-coplanar beams. The non-coplanar beams were carefully selected so that the beams would never exit patient bodies through the contralateral lung. The IMRT plans were generated with Pinnacle 9.8 treatment planning software. The IMRT optimization objectives were kept the same for the corresponding pairs of plans. All plans were normalized such that 95% of PTV receives the prescription dose (full dose). Results: The conformity index (mean±standard deviation of the mean) is 1.49±0.14 and 1.58±0.23 for the coplanar and noncoplanar plans, respectively. The heterogeneity index (mean±standard deviation of the mean) is 7.74 ±2.33 and 6.34±1.40 for the coplanar and non-coplanar plans, respectively. The maximum heart dose is 60.94±6.22 and 60.42±7.21 Gy, and mean heart dose is 10.22 ±7.57, 9.07 ±6.32 Gy, for the coplanar and non-coplanar plans, respectively. The ipsilateral lung V20 is 48.0%±2.4% and 47.5%±3.3%, and V5 is 68.2%±10.0% and 69.1%±7.3%, for the coplanar and noncoplanar plans, respectively. Furthermore, with the non-coplanar beam arrangement, the contralateral lung V20 was reduced from 3.3%±3.7% to 1.3%±0.8%, and the contralateral Lung V5 is reduced significantly from 65.6%±9.3% to 33.5%±20.9% (p value =0.008). Conclusion: The IMRT plans with non-coplanar beam arrangement could reduce the exit dose to the contralateral lung, and therefore reduce the contralateral lung V5 significantly. This method is especially helpful while the lung lesion doesn’t have a symmetric shape.

60 APPLIED LIFE SCIENCES↗

Analyzing the suitability of contemporary 3D-stacked PIM architectures for HPC scientific applications

Scaling off-chip bandwidth is challenging due to fundamental limitations, such as a fixed pin count and plateauing signaling rates. Recently, vendors have turned to 2.5D and 3D stacking to closely integrate system components. Interestingly, these technologies can integrate a logic layer under multiple memory dies, enabling computing capability inside a memory stack. This trend in stacking is making PIM architectures commercially viable. In this work, we investigate the suitability of offloading kernels in scientific applications onto 3D stacked PIM architectures. We evaluate several hardware constraints resulted from the stacked structure. We perform extensive simulation experiments and in-depth analysis to quantify the impact of application locality in TLBs, data caches, and memory stacks. Our results also identify design optimization areas in software and hardware for HPC scientific applications.

Peng, Ivy Bo↗

Slope Extensions to ASL Library

Extensions to the AMPL/solver interface library (http://netlib.sandia.gov/ampl/solvers) to compute bounds on algebraic expressions, plus a test program. use in uncertainty quantification and global optimization algorithms. This software is not primarily for military applications.

Gay, David↗