Search NASA⌕ Search

SEARCH · Search NASA

Results for “software performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

SU-E-T-230: Measurement of Proton-Activated Positron Emission with PRESAGE 3-D Dosimeters

Purpose: Measurement of positron emission following proton beam irradiation of a target has been studied as a method of in-vivo dosimetry. Relative dosimetry studies between a phantom and treatment plan are susceptible to range uncertainties from material heterogeneities and setup error. By using the radiochromic polyurethane dosimeter PRESAGE, we can correlate the proton dose distribution to the PET activity measurement within a single detector. The PRESAGE formulation used was developed for high-LET proton radiotherapy, has similar density and RLSP to tissue, and consists of a greater carbon component, which gives it a higher positron signal than many other 3D detectors. Methods: Three cylindrical PRESAGE dosimeters were irradiated semi-uniformly to 500 cGy with 180- MeV protons. The beam was directed along the dosimeter axis and delivered a 2-cm SOBP at the center of the dosimeter. The dosimeters were rushed to a nearby PET/CT where imaging began within 15 minutes, less than a single half-life of 11C. A 3-hr measurement captured the full activation decay. Afterwards, the dose profiles were measured by optical-CT. A direct comparison between the measured dose and the positron emission was performed using CERR software. Results: The correlations between dose distributions and PET activity were consistent with previous studies in that the proximal region of the SOBP displayed the highest activity. The spatial distributions between the dose and activity were similar. Along the central axis of the beam, we found a shift in the distal 80% of 1 cm. The lateral profile showed good agreement between dose and activity. PET imaging times between 30-min and 3-hrs showed <5% discrepancy. Conclusion: PRESAGE dosimeters offer a strong and unique potential to accurately correlate dosimetric and PET activation information. Implementation in an anthropomorphic phantom could be used to study representative treatment plans. NIH grant 5R01CA100835.

60 APPLIED LIFE SCIENCES↗

SU-E-T-402: Y-90 Microspheres (SIR Spheres) for Treatment of Liver Metastasis : Technique

Purpose: The purpose of this presentation is to discuss the radiation safety and dosimetric technique used for the therapeutic procedure using Y-90 microspheres through intra -arterial administration on patients with liver metastasis Methods: The radiation dosimetry, technique and safety aspects of 14 patients with primary and metastatic liver cancer, treated with Y-90 microsphere (SIR spheres) are discussed. The liver and tumor volumes were determined using the CT and MR scans . The images were imported into the treatment planning system and the liver and tumor volumes and the volume of the liver affected were outlined and the volume calculation was performed using the software. The lung shunt fraction (LSF) and tumor to liver uptake ratio (TLR) were determined using the nuclear medicine SPECT imaging with Tc-99m MAA. The absorbed dose to the target volume in liver was calculated using the following equation:Dose ? (Gy) = C x E? x 5.92 x 10-6 (Gy/s) x T(1/2)(days) x 1.44 x 8.64 x 104 (s) The distribution of activity in the tumor bed was confirmed by post Y-90 administration imaging using the Bremsstrahlung peak at 30% window. The patient and the procedure room were surveyed and radiation safety instructions were given to the patient Results: The tumor volume ranged from 77 cc to 700 cc, tumor to liver uptake ranged from 3 to 12. The lung shunt fraction varied from 1.08% to 9.0%. The activity administered ranged from 1.0GBq to 2.5 GBq, . The radiation survey in contact with the patient ranged from 1.8 mR/hr to 2.5 mR/hr and reading at 1 meter was less than 0.2 mR/hr Conclusion: The technique for radiation dosimetry and radiation safety for Y-90 microsphere therapy is established. The post treatment imaging helped to confirm the distribution of Y-90 microspheres inside the tumor bed.

60 APPLIED LIFE SCIENCES↗

A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then compared against dose calculated using TG-43 and MBDCA methods. Results: TG-43 and PSS datasets were generated for the generic source, the PSS data for use with the ACE algorithm. The dose-rate constant values obtained from seven MC simulations, performed independently using different codes, were in excellent agreement, yielding an average of 1.1109 ± 0.0004 cGy/(h U) (k = 1, Type A uncertainty). MC calculated dose-rate distributions for the two plans were also found to be in excellent agreement, with differences within type A uncertainties. Differences between commercial MBDCA and MC results were test, position, and calculation parameter dependent. On average, however, these differences were within 1% for ACUROS and 2% for ACE at clinically relevant distances. Conclusions: A hypothetical, generic HDR {sup 192}Ir source was designed and implemented in two commercially available TPSs employing different MBDCAs. Reference dose distributions for this source were benchmarked and used for the evaluation of MBDCA calculations employing a virtual, cubic water phantom in the form of a CT DICOM image series. The implementation of a generic source of identical design in all TPSs using MBDCAs is an important step toward supporting univocal commissioning procedures and direct comparisons between TPSs.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-91: Accuracy of Dose Calculation Algorithms for Patients Undergoing Stereotactic Ablative Radiotherapy

Purpose: The purpose of this study was to investigate and quantify the variation in dose distributions in small field lung cancer radiotherapy using seven different dose calculation algorithms. Methods: The study was performed in 21 lung cancer patients who underwent Stereotactic Ablative Body Radiotherapy (SABR). Two different methods (i) Same dose coverage to the target volume (named as same dose method) (ii) Same monitor units in all algorithms (named as same monitor units) were used for studying the performance of seven different dose calculation algorithms in XiO and Eclipse treatment planning systems. The seven dose calculation algorithms include Superposition, Fast superposition, Fast Fourier Transform ( FFT) Convolution, Clarkson, Anisotropic Analytic Algorithm (AAA), Acurous XB and pencil beam (PB) algorithms. Prior to this, a phantom study was performed to assess the accuracy of these algorithms. Superposition algorithm was used as a reference algorithm in this study. The treatment plans were compared using different dosimetric parameters including conformity, heterogeneity and dose fall off index. In addition to this, the dose to critical structures like lungs, heart, oesophagus and spinal cord were also studied. Statistical analysis was performed using Prism software. Results: The mean±stdev with conformity index for Superposition, Fast superposition, Clarkson and FFT convolution algorithms were 1.29±0.13, 1.31±0.16, 2.2±0.7 and 2.17±0.59 respectively whereas for AAA, pencil beam and Acurous XB were 1.4±0.27, 1.66±0.27 and 1.35±0.24 respectively. Conclusion: Our study showed significant variations among the seven different algorithms. Superposition and AcurosXB algorithms showed similar values for most of the dosimetric parameters. Clarkson, FFT convolution and pencil beam algorithms showed large differences as compared to superposition algorithms. Based on our study, we recommend Superposition and AcurosXB algorithms as the first choice of algorithms in lung cancer radiotherapy involving small fields. However, further investigation by Monte Carlo simulation is required to confirm our results.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-04: Comprehensive Machine Isocenter Evaluation with Separation of Gantry, Collimator, and Table Variables

Purpose: To develop and demonstrate application of a method that characterizes deviation of linac x-ray beams from the centroid of the volumetric radiation isocenter as a function of gantry, collimator, and table variables. Methods: A set of Winston-Lutz ball-bearing images was used to determine the gantry radiation isocenter as the midrange of deviation values resulting from gantry and collimator rotation. Also determined were displacement of table axis from gantry isocenter and recommended table axis adjustment. The method, previously reported, has been extended to include the effect of collimator walkout by obtaining measurements with 0 and 180 degree collimator rotation for each gantry angle. Twelve images were used to characterize the volumetric isocenter for the full range of available gantry, collimator, and table rotations. Results: Three Varian True Beam, two Elekta Infinity and four Versa HD linacs at five institutions were tested using identical methodology. Varian linacs exhibited substantially less deviation due to head sag than Elekta linacs (0.4 mm vs. 1.2 mm on average). One linac from each manufacturer had additional isocenter deviation of 0.3 to 0.4 mm due to jaw instability with gantry and collimator rotation. For all linacs, the achievable isocenter tolerance was dependent on adjustment of collimator position offset, transverse position steering, and alignment of the table axis with gantry isocenter, facilitated by these test results. The pattern and magnitude of table axis wobble vs. table angle was reproducible and unique to each machine. Conclusion: This new method provides a comprehensive set of isocenter deviation values including all variables. It effectively facilitates minimization of deviation between beam center and target (ball-bearing) position. This method was used to quantify the effect of jaw instability on isocenter deviation and to identify the offending jaw. The test is suitable for incorporation into a routine machine QA program. Software development was performed by Radiological Imaging Technology, Inc.

60 APPLIED LIFE SCIENCES↗

Measurement of the $\nu _{\mu }$ energy spectrum with IceCube-79

IceCube is a neutrino observatory deployed in the glacial ice at the geographic South Pole. The ν μ energy unfolding described in this paper is based on data taken with IceCube in its 79-string configuration. A sample of muon neutrino charged-current interactions with a purity of 99.5% was selected by means of a multivariate classification process based on machine learning. The subsequent unfolding was performed using the software Truee. The resulting spectrum covers an E ν -range of more than four orders of magnitude from 125 GeV to 3.2 PeV. Compared to the Honda atmospheric neutrino flux model, the energy spectrum shows an excess of more than 1.9σ in four adjacent bins for neutrino energies E ν ≥ 177.8TeV. The obtained spectrum is fully compatible with previous measurements of the atmospheric neutrino flux and recent IceCube measurements of a flux of high-energy astrophysical neutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Delayed Update Algorithms for Quantum Monte Carlo Simulation on GPU: Extended Abstract

QMCPACK is open source scientific software designed to perform Quantum Monte Carlo (QMC) simulation, a first-principles method for describing many-body systems. The evaluation of each Monte Carlo move requires finding the determinant of a dense matrix in the wave functions. This calculation forms a key computational kernel in QMCPACK. After each accepted event, the wave function matrix undergoes a rank-one update to represent a single particle move within the system. The matrix inverse is updated via the Sherman-Morrison formula; occasionally, the explicit inverse must be recomputed to maintain numerical stability.; We propose an alternate approach to this kernel that utilizes QR factorization to maintain stability without refactorization. In addition, algorithms based on a novel delayed update scheme are explored in this effort. This strategy enables probability evaluation for multiple successive Monte Carlo moves, with application of accepted moves to the wave function matrix delayed until an event is denied, or a predetermined limit on acceptances p is reached. Accepted events grouped in this manner are then applied to the matrix en bloc with enhanced arithmetic intensity and computational efficiency. Delayed update Sherman-Morrison probability evaluation algorithms with CPU and GPU-accelerated implementations are tested, profiled, and analyzed. A QR based delayed update algorithm remains in development. Results are evaluated against existing methods for numerical stability and efficiency; emphasis is placed on large systems, for which acceleration is critical.

Computer Science↗

SwitchX : Gmin-Gmax Switching for Energy-efficient and Robust Implementation of Binarized Neural Networks on ReRAM Xbars

Memristive crossbars can efficiently implement Binarized Neural Networks (BNNs) wherein the weights are stored in high-resistance states (HRS) and low-resistance states (LRS) of the synapses. We propose SwitchX mapping of BNN weights onto ReRAM crossbars such that the impact of crossbar non-idealities, that lead to degradation in computational accuracy, are minimized. Essentially, SwitchX maps the binary weights in such a manner that a crossbar instance comprises of more HRS than LRS synapses. We find BNNs mapped onto crossbars with SwitchX to exhibit better robustness against adversarial attacks than the standard crossbar mapped BNNs, the baseline. Finally, we combine SwitchX with state-aware training (that further increases the feasibility of HRS states during weight mapping) to boost the robustness of a BNN on hardware. We find that this approach yields stronger defense against adversarial attacks than adversarial training, a state-of the-art software defense. We perform experiments on a VGG16 BNN with benchmark datasets (CIFAR-10, CIFAR-100 and TinyImagenet) and use Fast Gradient Sign Method (ϵ = 0.05 to 0.3) and Projected Gradient Descent (ϵ = $\frac{2}{255}$ to $\frac{32}{255}$, α = $\frac{2}{255}$) adversarial attacks. We show that SwitchX combined with state-aware training can yield upto ~35% improvements in clean accuracy and ~6–16% in adversarial accuracies against conventional BNNs. Furthermore, an important by-product of SwitchX mapping is increased crossbar power savings, owing to an increased proportion of HRS synapses, which is furthered with state-aware training. We obtain upto ~21–22% savings in crossbar power consumption for state-aware trained BNN mapped via SwitchX on 16 × 16 and 32 × 32 crossbars using the CIFAR-10 and CIFAR-100 datasets.

97 MATHEMATICS AND COMPUTING↗

VOLTTRON Version 3.x

VOLTTRON™ is an agent execution platform providing services to its agents that allow them to easily communicate with physical devices and other resources. VOLTTRON™ delivers an innovative distributed control and sensing software platform that supports modern control strategies, including agent-based and transaction-based controls. It enables mobile and stationary software agents to perform information gathering, processing, and control actions. VOLTTRON™ can independently manage a wide range of applications, such as HVAC systems, electric vehicles, distributed energy or entire building loads, leading to improved operational efficiency.

Source record↗

VOLTTRON Version 4

VOLTTRON™ is an agent execution platform providing services to its agents that allow them to easily communicate with physical devices and other resources. VOLTTRON™ delivers an innovative distributed control and sensing software platform that supports modern control strategies, including agent-based and transaction-based controls. It enables mobile and stationary software agents to perform information gathering, processing, and control actions. VOLTTRON™ can independently manage a wide range of applications, such as HVAC systems, electric vehicles, distributed energy or entire building loads, leading to improved operational efficiency.

Source record↗

VOLTTRON Version 5.0

VOLTTRON is an agent execution platform providing services to its agents that allow them to easily communicate with physical devices and other resources. VOLTTRON delivers an innovative distributed control and sensing software platform that supports modern control strategies, including agent-based and transaction-based controls. It enables mobile and stationary software agents to perform information gathering, processing, and control actions. VOLTTRON can independently manage a wide range of applications, such as HVAC systems, electric vehicles, distributed energy or entire building loads, leading to improved operational efficiency.

Source record↗

MapReduce MPI library (MR-MPI) v. 1.0

The MapReduce MPI library is a software tool for performing MapReduce operations on a distributed memory parallel computer via message passing (MPI). These are data-processing or computational operations which achieve parallelism by breaking a large task into two stages, a map and a reduce . Each of these are formulated as simple on-processor functions which the user can easily write. The library assigns independent tasks to processors and performs the parallel data movement and transformations behind the scenes.

PLIMPTON, STEVEN↗

QuanSimBench

QuanSimBench is a software program that performs a gate-by-gate simulation of a quantum computer with a full state vector formulation. It simulates a simplified version of Shor's algorithm with increasing number of qubits until resources are exhausted. The score (states/s) is how fast the Approximate Quantum Fourier Transform can be computed (the modular exponentiation is not timed). The goal is to quantify the ability of a computer to simulate ideal quantum circuits.

Pakin, Scott↗

BDEM (Discrete-element-simulator for high-solids granular flows) [SWR-22-72]

BDEM is a discrete element method based simulation tool developed specifically for modeling high-solids granular flows that include polydispersity, heat-transfer, moving boundaries and chemistry. Our solver provides facilities for simulating spherical/non-spherical particles with modified contact and friction models in complex dynamic geometries defined using level-sets or triangulated files. The solver is developed on top of NREL's open-source performance portable library, AMReX, providing parallel execution capabilities on current and upcoming high-performance-computing (HPC) architectures. Simulations at the scale of several millions to billion particles have been performed using this software on large scale computing resources. This software can be applied to non-reacting solids dominant flows in silos, hoppers and screw conveyors as well as in high temperature reacting systems such as screw kilns and auger reactors.

Sitaraman, Hariswaran↗

PSUADE

PSUADE (Problem Solving testbed for Uncertainty Analysis and Design Exploration) is a mathematical software useful for performing uncertainty quantification and sensitivity analysis.

Tong, CharlesH↗

Reposcanner

SAND2023-05455O Reposcanner provides a highly modular, extensible framework for defining routines for mining data from software repositories and performing analyses on that data to yield valuable insights on team behaviors. Reposcanner features seamless support for different version control platforms like GitHub, Gitlab, and Bitbucket; smart parsing of URLs; intelligent credential management capabilities; and a comprehensive test suite. Reposcanner is connected to the Exascale Computing Project and is intended for research purposes.

Mundt, Miranda↗

Spawn v.0.5.0 Released 12.15.2023 [SWR-SWR-20-10]

Spawn is a software package for performing co-simulations involving NREL's EnergyPlus™ tool and Modelica. This package bundles the following items in one self-contained package. 1. A method for connecting EnergyPlus models to Modelica 2. A Modelica compiler toolchain for compiling and running Modelica models 3. Modelica libraries and content, including the Modelica Buildings Library (MBL) and the Modelica Standard Library. The Spawn installation package is fully self-contained, and there are no external third-party dependencies. Together the capabilities in this package provide a single integrated environment for performing hybrid Modelica and EnergyPlus simulations. The primary entry point is the Spawn command line interface.

Li, Yanfei↗

pnnl/ZebrafishBMD

ZebrafishBMD: A software tool to perform benchmark dose calculations using toxicity screening data of high-throughput zebrafish assays. High-content imaging of larval zebrafish behavior can be used as a screening approach to rapidly evaluate the relative potential for chemicals to cause toxicity. However, most statistical methods applied to these data transform movement values to incidence-based “hits” and calculate lowest effect levels (LELs), which loses individual fish resolution of behavior and defies hazard ranking due to reliance on applied dose levels. We developed a parallelizable workflow to calculate benchmark dose (BMD) values from dynamic, high-content zebrafish behavior data that scales for high throughput chemical screening. To capture the zebrafish movement response from light to dark stimulus, we summarized time-dependent data using both area under the curve and the immediate change at the transition point into two novel metrics that characterized abnormal behavior as a function of chemical concentration. The BMD workflow was applied to calculate BMD10 values of 1,060 ToxCast chemicals for 24 zebrafish endpoints, including behavior, mortality and morphology. ZebrafishBMD implements the BMD workflow and provides Matlab scripts to read the data (stored in a specific structure) from a .mat file, to calculate the behavioral endpoint values from movement versus time data, to construct concentrationresponse curves, to perform curve-fitting, and to calculate BMD10 values.

Thomas, Dennis↗