Search NASA⌕ Search

SEARCH · Search NASA

Results for “software validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Exploring the Nature of Neutrinos with the Deep Underground Neutrino Experiment (DUNE)

The Deep Underground Neutrino Experiment (DUNE) is a next-generation experimental program designed to study the behaviour of neutrino oscillation. DUNE will utilize a neutrino beam originating at Fermilab, near Chicago, and will leverage a detector at Fermilab (Near Detector) and a detector 1300 km away in South Dakota (Far Detector), south of Saskatchewan. In the first phase of DUNE, its Far Detector will comprise of two 10,000 ton (fiducial) liquid argon (LAr) time-projection chamber (TPC) modules – powerful tracking calorimeter detectors – placed nearly a mile underground. With this large, sensitive, underground detector, DUNE aims to collect a high statistics and pure sample of neutrinos at the Far Detector. This setup also offers the potential to study non-beam physical processes via e.g. neutrinos produced in the atmosphere, supernova neutrino bursts, and/or solar neutrinos, etc. A second phase will aim to add more detector mass and expand the program. The Near Detector will consist of a LAr TPC module as well: critical to constraining systematic uncertainties in the oscillation analysis. However, this LAr TPC will have a novel design using a pixel-based readout instead of the traditional wire-based readout. This and the segmentation of the LAr TPC into multiple units are crucial in mitigating the high multiplicity of neutrino interactions expected in any readout window given its proximity to the beam. The Near Detector will feature additional components and capability beyond the LAr TPC, allowing one to deeply characterize the neutrino flux. Due to the complexity of this experimental program, several smaller-scale prototype detectors have been operating to test, validate, and improve both the technical designs and software for processing and analyzing events. By operating in charged particle test beams or neutrino beams, several of the prototypes are also capable of producing valuable results. Canadian institutions are involved in the realization of the DUNE through efforts with both the Near and Far Detectors and prototypes. DUNE is anticipated to begin operating near the end of this decade/the beginning of the next. This talk will focus on the overall DUNE program, for example its ultimate plans, status, and the efforts with prototypes.

Howard, Bruce [York U., Canada; Fermilab]↗

GPS Data Filtration Method for Drive Cycle Analysis Applications

When employing GPS data acquisition systems to capture vehicle drive-cycle information, a number of errors often appear in the raw data samples, such as sudden signal loss, extraneous or outlying data points, speed drifting, and signal white noise, all of which limit the quality of field data for use in downstream applications. Unaddressed, these errors significantly impact the reliability ofsource data and limit the effectiveness of traditional drive-cycle analysis approaches and vehicle simulation software. Without reliable speed and time information, the validity of derived metrics for drive cycles, such as acceleration, power, and distance, become questionable. This study explores some of the common sources of error present in raw onboard GPS data and presents a detailedfiltering process designed to correct for these issues. Test data from both light and medium/heavy duty applications are examined to illustrate the effectiveness of the proposed filtration process across the range of vehicle vocations. Graphical comparisons of raw and filtered cycles are presented, and statistical analyses are performed to determine the effects of the proposed filtration processon raw data. Finally, an evaluation of the overall benefits of data filtration on raw GPS data and present potential areas for continued research is presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of the ORIGEN Fallout Analysis Tool and the DELFIC Fallout Planning Tool to National Technical Nuclear Forensics

The objective of this project was to provide a robust fallout analysis and planning tool for the National Technical Nuclear Forensics interagency ground sample collection team. Their application called for a fast-running, portable mission-planning tool for use in response to emerging improvised nuclear device (IND) post-detonation situations. The project met those goals by research and development of models to predict the physical, chemical, and radiological properties of fallout debris. ORNL has developed new graphical user interfaces for two existing codes, the Oak Ridge Isotope Generation (ORIGEN) code and the Defense Land Fallout Interpretive Code (DELFIC). ORIGEN is a validated, radionuclide production and decay code that has been implemented into the Fallout Analysis Tool to predict the fallout source term nuclide inventory after the detonation of an IND. DELFIC is a validated, physics-based, research reference fallout prediction software package. It has been implemented into the Fallout Planning Tool and is used to predict the fractionated isotope concentrations in fallout, particle sizes, fractionation ratios, dose rate, and integrated dose over the planned collection routes - information vital to ensure quality samples for nuclear forensic analysis while predicting dose to the sample collectors. DELFIC contains a particle activity module, which models the radiochemical fractionation of the elements in a cooling fireball as they condense into and onto particles to predict the fractionated activity size distribution for a given scenario. This provides the most detailed physics-based characterization of the fallout source term phenomenology available in an operational fallout model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Swarm Optimization Algorithm for Critical Experiment Design

Nuclear criticality experiments are used to validate nuclear cross section data used by simulation software. This is typically achieved by designing a critical system with a high sensitivity to a certain material’s cross section. Once the experiment has been carried out, a high fidelity model of the system is developed into a benchmark. When this benchmark model is simulated by a transport code, some of the difference between the experimental and computational effective neutron multiplication factor can be attributed to inaccurate nuclear data. Nuclear data evaluators then can make adjustments accordingly to improve cross section data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implementation of Oak Ridge National Laboratory Software Quality Assurance Requirements for COMSOL 3.4

It is desirable for nuclear safety-related calculations to be performed at the Oak Ridge National Laboratory (ORNL) using COMSOL. The Department of Energy (DOE) has mandated that ORNL will incorporate software quality assurance (SQA) with special attention to nuclear safety-related software applications. The author has developed a procedure for implementing these DOE-mandated SQA requirements on nuclear safety-related software applicable to the High Flux Isotope Reactor (HFIR). This paper will describe how this procedure will be implemented for COMSOL so that nuclear safety-related calculations may be performed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY2021 Improvements to the New CTH Code Verification & Validation Test Suite

Over the past few years, the CTH multiphysics hydrocode has overhauled its software quality and testing processes, implementing current best practices in software quality and building a robust V&V test suite comprised of traditional hydrocode verification problems, including ASC Tri-Lab Test Suite and Enhanced Tri-Lab Test Suite problems, as well as validation problems for some of CTH’s most frequently used equations of state, materials models, and other key capabilities. Substantial progress towards building this new test suite was made in FY19 and FY20. In FY21, the test suite has been expanded to include verification and validation tests of the Steinberg-Guinan-Lund (ST) viscoplastic model and the Johnson Cook (JFRAC) fracture model. Additionally, two new verification tests were added, covering hydrodynamics and high explosive (HE) modeling capabilities: the Kidder Gaussian density problem and the Escape of HE Products (EHEP) problem from the Tri-Lab Test Suite. This report discusses each of these test problems in detail. Verification test results are compared to analytic solutions. Validation test results are compared to experimental data. Wherever possible, convergence or mesh refinement studies are included. Additionally, while implementing the Kidder verification problem, a bug was identified that affects the use of tables to initialize pressure or density in 1D or 2D calculations. A brief discussion of the bug and its fix is included. CTH demonstrates good performance overall on the new test suite problems. Simulation results showed good agreement with analytic solutions for the Kidder problem, with convergence rates ranging between 1.8 and sub-linear, and relatively good agreement for the EHEP problem, though convergence rates for pressure and density were nearly 0. The ST and JFRAC strain rate loading verification tests show good agreement with analytic solutions. Likewise, CTH simulation results show good agreement with experimental validation data, including Taylor rod impact testing, for the materials tested. Future V&V work will focus on adding 2D and 3D versions of existing verification tests as well as adding validation tests of other frequently used capabilities such as other fracture models.

42 ENGINEERING↗

Plutonium Critical Mass Curve Comparison to Mass at Upper Subcritical Limit (USL) Using Whisper

Whisper is computational software designed to assist the nuclear criticality safety analyst with validation studies with the MCNP ® Monte Carlo radiation transport package. Standard approaches to validation rely on the selection of benchmarks based upon expert judgment. Whisper uses sensitivity/uncertainty (S/U) methods to select relevant benchmarks to a particular application or set of applications being analyzed. Using these benchmarks, Whisper computes a calculational margin. Whisper attempts to quantify the margin of subcriticality (MOS) from errors in software and uncertainties in nuclear data. The combination of the Whisper-derived calculational margin and MOS comprise the baseline upper subcritical limit (USL), to which an additional margin may be applied by the nuclear criticality safety analyst as appropriate to ensure subcriticality. A series of critical mass curves for plutonium, similar to those found in Figure 31 of LA-10860-MS, have been generated using MCNP6.1.1 and the iterative parameter study software, WORM_Solver. The baseline USL for each of the data points of the curves was then computed using Whisper 1.1. The USL was then used to determine the equivalent mass for plutonium metal-water system. ANSI/ANS-8.1 states that it is acceptable to use handbook data, such as the data directly from the LA-10860-MS, as it is already considered validated (Section 4.3 4) “Use of subcritical limit data provided in ANSI/ANS standards or accepted reference publications does not require further validation.”). This paper attempts to take a novel approach to visualize traditional critical mass curves and allows comparison with the amount of mass for which the k eff is equal to the USL (calculational margin + margin of subcriticality). However, the intent is to plot the critical mass data along with USL, not to suggest that already accepted handbook data should have new and more rigorous requirements for validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MARVEL Instrumentation, Control, and Software Considerations

This paper details the various I&C considerations and design decisions made throughout the MARVEL (Micro-reactor Applications Research Validation and Evaluation) project, including sensor and actuator selection, safety-related functionality, digital control hardware and software, and testing methodologies. Key challenges such as managing radiation, temperature, and space constraints are discussed, along with the trade-offs between using standard equipment and custom solutions. The successful integration of off-the-shelf components, the emphasis on minimizing safety-related instrumentation, and the lessons learned from prototyping and testing are highlighted. The authors aim to provide insights that can benefit future micro-reactor designs and emphasize the importance of real-world testing in advancing reactor technology.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Initial Validation of the Neutron Physics Codes in COSINE Using the MIT BEAVRS Benchmark

A software package for nuclear power plant design and analysis, known as COSINE, has been developed by State Nuclear Power Software Development Center (SNPSDC). A detailed benchmark called BEAVRS which includes measured reactor data is presented by MIT. The BEAVRS benchmark is based on a commercial power plant and provides a highly-detailed Pressurized Water Reactor (PWR) specification with measured operational data that has been used to validate the neutron physics codes in COSINE. In this paper, a COSINE core model is prepared to calculate the BEAVRS benchmark. The first stage validation is focused on the depletion of two cycles and initial physics test of cycle 1. The calculation results agree well with the measured data. It could be confirmed that the COSINE codes package has the ability to design and analyze a commercial PWR core, and the precision of the calculation results can meet the requirements of industrial design and analysis. A calculation of MIT BEAVRS benchmark using COSINE has been performed in this paper. A lot of measurements are given in the benchmark specification which can be used for code validation. The calculation includes a depletion calculation of both two cycles and a calculation of the initial physics test of cycle 1. COSINE neutron physics codes use the mature industrial calculation method which can achieve reasonable results with acceptable accuracy and speed. Through the calculation, it can be seen that the difference of critical boron concentration calculated from cos Nu is less than 25 pcm compared with measured data. And the relative difference of rod worth is less than 10%. The isothermal temperature coefficient difference between measurement and calculation is less than 1 pcm/deg. F. All results meet the criteria of ANS. The validation for measurements after initial physics test following a more complex power history and the validation for in-core detector signals are underway. (authors)

97 MATHEMATICS AND COMPUTING↗

Lecture Notes on Criticality Safety Validation Using MCNP & Whisper

Training classes for nuclear criticality safety, MCNP documentation. The need for, and problems surrounding, validation of computer codes and data area considered first. Then some background for MCNP & Whisper is given--best practices for Monte Carlo criticality calculations, neutron spectra, S(α,β) thermal neutron scattering data, nuclear data sensitivities, covariance data, and correlation coefficients. Whisper is computational software designed to assist the nuclear criticality safety analyst with validation studies with the Monte Carlo radiation transport package MCNP. Whisper's methodology (benchmark selection – C k 's, weights; extreme value theory – bias, bias uncertainty; MOS for nuclear data uncertainty – GLLS) and usage are discussed.

42 ENGINEERING↗

PUFFIn – A user friendly fast interface for calculating and visualizing the dose distribution in materials

This article describes a new graphical user interface that uses the PENELOPE Monte Carlo code to calculate dose distributions in materials. It is named PUFFIn, for the Penelope User-Friendly Fast Interface and was developed as an educational and scoping analysis tool for non-experts in radiation modeling. PUFFIn enables the user to visualize and compare the dose distributions in objects (e.g., sterilized healthcare products) irradiated with cobalt-60 gamma-rays, electron beam (E-beam) or X-rays. From such comparisons, the user can determine the most efficient product and/or packaging designs for any given radiation field – whether for conceptual or existing products and packaging. PUFFIn is distributed in a complete, self-contained package of software, including the PENELOPE radiation transport code, a standard graphics package, and a set of simple exercises. The package is available to any user at no cost and requires a minimal amount of training compared to other similar software. PUFFIn's capabilities are described, as well as validation measurements performed at Texas A&M University E-beam facility and the Aerial E-beam Facility in France.

97 MATHEMATICS AND COMPUTING↗

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report)

Project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. The overarching objective of this program is to improve photovoltaic (PV) module reliability via development of tests and standards. Where reliability problems or risk are discovered, we can design tests to ensure that these liabilities don't affect future generations of products. Customers can use these tests to understand which products are susceptible to certain degradation mechanisms, and manufacturers can use the tests to design unwanted characteristics out of their products. The work under this program identifies PV reliability needs, performs characterization that provides scientific understanding of targeted degradation mechanisms, and translates those data into practical and predictive test protocols and standards. Major accomplishments include: A model for polarization-type potential induced degradation (PID-p) was developed and validated against experimental data. NREL is currently leading a new edition of IEC 62804-1 for PID detection. PID-p can cause large losses in current and voltage for some module designs on cloudy days. Finite element modeling (FEM) and experiment was used to determine when cells crack in a module. It was shown that cells in landscape orientation are much more likely to crack than those on portrait orientation. Shortly thereafter, the first products with portrait-oriented cells were introduced. Studies of how to test for light and elevated temperature degradation (LeTID) culminated with the publication of IEC TS 63342. Software to predict the progression of LeTID was developed, validated, and made publicly available. Field validated tests and international standards for durability of PV module coatings abrasion, backsheets, and encapsulants were developed. Examples are IEC 62788-1-1, IEC 62788-2 ED2, IEC TS 62788-7-2, IEC 62788-7-3 ED1, IEC 63209-2. NREL led the development a high-temperature testing technical specification, and published guidelines that enable installers to determine whether higher-temperature testing is needed, simply based on location and mounting configuration. In a number of our case studies, variations in the bills of materials or workmanship have been associated with variations in reliability. These observations emphasize the importance of quality assurance to reliability. A framework for criticality (i.e. Pareto) analysis was developed and published. The framework helps us and other researchers determine what problems should be addressed for reliability research to have the biggest industry impact. NREL continues to participate actively in international standards development and stakeholder engagement activities, including organizing an annual PV Reliability Workshop. These activities are important for ensuring we address issues that are relevant and timely, and that we convey our results to those who may benefit.

14 SOLAR ENERGY↗

Software Quality Assurance for LeachXS/ORCHESTRA as a Tool for Assessment of Waste Management Systems Performance - 17486

Qualified modeling and simulation tools and experimental data are needed to provide a reasonable basis for the incorporation of realistic wasteform retention assumptions (i.e., those without orders-of-magnitude conservatism) into performance assessments and regulatory decisions. Use of highly conservative assumptions in performance assessments has historically led to the overprediction of release and near-field transport by as much as 4- to 6-orders of magnitude thereby limiting the nature and quantities of certain contaminants of concern in near surface disposal facilities. This project provides peer-reviewed models and characterization methods to provide more reasonable assumptions for use in performance assessments and regulatory decisions. Simulations tools have been developed to predict hydraulic and chemical performance of waste-forms and barriers used in nuclear applications under several important aging and degradation scenarios, including sulfate attack, carbonation, oxidation, cracking, and leaching; these tools are complaint with DOE Order 414.1D and ASME NQA-1. Wasteform characterization methods have been developed that are consistent with US EPA's Leaching Environmental Assessment Framework (LEAF) currently part of EPA's Hazardous Waste Test Methods (SW-846); the resulting experimental data are evaluated using LeachXS. ORCHESTRA models, that can be called seamlessly from LeachXS, have been developed representing both laboratory and field conditions; these models have undergone an extensive Software Quality Assurance process where they have been calibrated (where necessary), verified, and validated to be compliant with relevant guidelines. The models used for field predictions have also been incorporated into the Cementitious Barriers Partnership (CBP) Software Toolbox that allows probabilistic evaluation of field scenarios. The foci over the next year will be on providing 1) a mechanistic basis for projecting the retention of Tc-99, I-129, and other important radionuclides in near-surface disposal facilities at the Savannah River and Hanford Sites and 2) a technical basis for assessing the efficacy of macro-encapsulation of mercury-contaminated debris at the Oak Ridge Reservation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-J-42: Customized Deformable Image Registration Using Open-Source Software SlicerRT

Purpose: SlicerRT is a flexible platform that allows the user to incorporate the necessary images registration and processing tools to improve clinical workflow. This work validates the accuracy and the versatility of the deformable image registration algorithm of the free open-source software SlicerRT using a deformable physical pelvic phantom versus available commercial image fusion algorithms. Methods: Optical camera images of nonradiopaque markers implanted in an anatomical pelvic phantom were used to measure the ground-truth deformation and evaluate the theoretical deformations for several DIR algorithms. To perform the registration, full and empty bladder computed tomography (CT) images of the phantom were obtained and used as fixed and moving images, respectively. The DIR module, found in SlicerRT, used a B-spline deformable image registration with multiple optimization parameters that allowed customization of the registration including a regularization term that controlled the amount of local voxel displacement. The virtual deformation field at the center of the phantom was obtained and compared to the experimental ground-truth values. The parameters of SlicerRT were then varied to improve spatial accuracy. To quantify image similarity, the mean absolute difference (MAD) parameter using Hounsfield units was calculated. In addition, the Dice coefficient of the contoured rectum was evaluated to validate the strength of the algorithm to transfer anatomical contours. Results: Overall, SlicerRT achieved one of the lowest MAD values across the algorithm spectrum, but slightly smaller mean spatial errors in comparison to MIM software (MIM). On the other hand, SlicerRT created higher mean spatial errors than Velocity Medical Solutions (VEL), although obtaining an improvement on the DICE to 0.91. The large spatial errors were attributed to the poor contrast in the prostate bladder interface of the phantom. Conclusion: Based phantom validation, SlicerRT is capable of achieving comparable DIR accuracy to commercial programs such as MIM and VEL.

60 APPLIED LIFE SCIENCES↗

Validation and Comparison of HyRAM Physics Models

The Hydrogen Risk Assessment Models (HyRAM) software version 3 uses a real gas equation of state rather than the Abel-Noble equation of state that is used in 2.0 and previous versions. This change enables the use of HyRAM 3 for cryogenic hydrogen flows, whereas the Abel-Noble equation of state is not accurate at low temperatures. HyRAM 3.1 results were compared to experimental data from the literature in order to demonstrate the accuracy of the physics models. HyRAM 3.1 results were also compared to HyRAM 2.0 for high-pressure, non-cryogenic flows to highlight the differences in predictions between the two major versions of HyRAM. Validation data sets are from multiple groups and span the range of HyRAM physics models, including tank blowdown, unignited dispersion jet plume, ignited jet flame, and accumulation and overpressure inside an enclosure. Both versions 2.0 and 3.1 of HyRAM are accurate for predictions of blowdowns, diffusion jets, and diffusion flames of hydrogen at pressures up to 900 bar, and HyRAM 3.1 also shows good agreement with cryogenic hydrogen data. Overall, HyRAM 3.1 improves on the accuracy of the physical models relative to HyRAM 2.0. In most cases, this reduces the conservatism in risk calculations using HyRAM.

08 HYDROGEN↗

PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data

Mass spectrometry is broadly employed to study complex molecular mechanisms in various biological and environmental fields, enabling 'omics' research such as proteomics, metabolomics, and lipidomics. As study cohorts grow larger and more complex with dozens to hundreds of samples, the need for robust quality control (QC) measures through automated software tools becomes paramount to ensure the integrity, high quality, and validity of scientific conclusions from downstream analyses and minimize the waste of resources. Since existing QC tools are mostly dedicated to proteomics, automated solutions supporting metabolomics are needed. To address this need, we developed the software PeakQC, a tool for automated QC of MS data that is independent of omics molecular types (i.e., omics-agnostic). It allows automated extraction and inspection of peak metrics of precursor ions (e.g., errors in mass, retention time, arrival time) and supports various instrumentations and acquisition types, from infusion experiments or using liquid chromatography and/or ion mobility spectrometry front-end separations and with/without fragmentation spectra from data-dependent or independent acquisition analyses. Diagnostic plots for fragmentation spectra are also generated. Here, in this paper, we describe and illustrate PeakQC’s functionalities using different representative data sets, demonstrating its utility as a valuable tool for enhancing the quality and reliability of omics mass spectrometry analyses.

47 OTHER INSTRUMENTATION↗

Building an Efficient Cluster Cosmology Software Package for Modeling Cluster Counts and Lensing

We introduce a software suite developed for galaxy cluster cosmological analysis with the Dark Energy Survey Data. Cosmological analyses based on galaxy cluster number counts and weak-lensing measurements need efficient software infrastructure to explore an increasingly large parameter space, and account for various cosmological and astrophysical effects. Our software package is designed to model the cluster observables in a wide-field optical survey, including galaxy cluster counts, their averaged weak-lensing masses, or the cluster's averaged weak-lensing radial signals. To ensure maximum efficiency, this software package is developed in C++ in the CosmoSIS software framework, making use of the CUBA integration library. We also implement a testing and validation scheme to ensure the quality of the package. We demonstrate the effectiveness of this development by applying the software to the Dark Energy Survey Year 1 galaxy cluster cosmological data sets, and acquired cosmological constraints that are consistent with the fiducial Dark Energy Survey analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Containerization in ATLAS Software Development and Data Production

The ATLAS experiment's software production and distribution on the grid benefits from a semi-automated infrastructure that provides up-to-date information about software usability and availability through the CVMFS dis-tribution service for all relevant systems. The software development process uses a Continuous Integration pipeline involving testing, validation, packag-ing and installation steps. For opportunistic sites that can not access CVMFS, containerized releases are needed. These standalone containers are currently created manually to support Monte-Carlo data production at such sites. In this paper we will describe an automated procedure for the containerization of AT-LAS software releases in the existing software development infrastructure, its motivation, integration and testing in the distributed computing system.

97 MATHEMATICS AND COMPUTING↗