Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Airborne Observations of Aerosol Properties in Southeast Asia: Overview of Emissions, Cloud Processing, and Long Range Transport during NASA CAMP2Ex

The Southwest Monsoon represents an important synoptic scale meteorological feature that modulates precipitation throughout Southeast Asia. In addition, southwesterly flow can funnel large amounts of biomass burning aerosol into heavily populated areas throughout the Philippines, mixing with urban emissions and representing a significant air quality issue. From a climate perspective, understanding interactions between these particles and clouds has important societal ramifications through frequent extreme periods of flood and drought. Here we present airborne observations made in support of the NASA CAMP2Ex (Cloud and Aerosol Monsoonal Processes-Philippines Experiment) mission aboard the Wallops Flight Facility P-3 research aircraft, based at Clark International Airport in the Luzon region of Northern Philippines. Nineteen research flights were conducted in August-October of 2019. An extensive suite of aerosol microphysical, optical, and chemical instrumentation was deployed, along with trace gas and remote sensing measurements, to characterize aerosol emissions and their vertical/spatial variability associated with moderately convective marine cloud systems in the region. Analysis will focus on characterizing disparate aerosol sources with respect to derived chemical and optical properties relevant to global circulation modeling. For example, higher than expected mass scattering efficiencies for aged biomass burning emissions, derived from a combination of nephelometer and aerosol mass spectrometer measurements, are attributed to increased particle size and decreased density. Results will also illustrate the evolution of aerosols from Indonesian agricultural biomass burning activities into the Philippines region, in comparison with urban emissions from the megacity Manila and transported air masses from mainland Asia.

Luke David Ziemba↗

US Contributions to the Athena Wide Field Imager

The world’s premier X-ray astronomical observatories, Chandra and XMM-Newton, have been operating for about 20 years. The next flagship X-ray observatory launched will be ESA’s Athena mission. We discuss planned US contributions to the Athena Wide Field Imager instrument, which encompass transient source detection, background characterization and reduction, and detector electronics design and testing, in addition to scientific contributions.

David N. Burrows↗

The Heraklion Extragalactic Catalogue (HECATE): A Value-added Galaxy Catalogue for Multimessenger Astrophysics

We present the Heraklion Extragalactic Catalogue, or HECATE, an all-sky value-added galaxy catalogue, aiming to facilitate present and future multiwavelength and multi messenger studies in the local Universe. It contains 204 733 galaxies up to a red shift of 0.047 (D200 Mpc), and it is>50 per cent complete in terms of the B-band luminosity density at distances in the0–170 Mpc range. By incorporating and homogenizing data from astronomical data bases and multiwavelength surveys, the catalogue offers positions, sizes, distances, morphological classifications, star formation rates, stellar masses, metallicities, and nuclear activity classifications. This wealth of information can enable a wide range of applications, such as (i) demographic studies of extragalactic sources, (ii) initial characterization of transient events, and (iii) searches for electromagnetic counterparts of gravitational-wave events. The catalogue is publicly available to the community at a dedicated portal, which will also host future extensions in terms of the covered volume and data products.

K Kovlakas↗

Molecular flow venting of a volume with an outgassing or desorbing source

A venting equation commonly used to describe the transient evolution of pressure within a volume containing an outgassing or offgassing source and a restrictive vent conductance under conditions of molecular flow has been solved analytically. Solutions are found for sources of finite thickness characterized by classical diffusion-limited behavior (proportional to inverse square root of time), as well as responses for thick material sources often observed in testing that are characterized by a more general form of power-law decay, up to inverse time behavior associated with surface desorption. Solutions involve evaluating integrals where both numerators and denominators of the integrands diverge with time, making wide-ranging transient solutions difficult to directly compute numerically. Usually, one can avoid evaluating these integrals by assuming quasistatic conditions at long time scales. A novel approach is used in this work to analytically produce solutions by generating bespoke mathematical functions, some of which solve integrals that have apparently had no previous analytical solution.

Michael Woronowicz↗

Molecular flow venting of a volume with an outgassing or desorbing source

"A venting equation commonly used to describe the transient evolution of pressure within a volume containing an outgassing or offgassing source and a restrictive vent conductance under conditions of molecular flow has been solved analytically. Solutions are found for sources of finite thickness characterized by classical diffusion-limited behavior (proportional to inverse square root of time), as well as responses for thick material sources often observed in testing that are characterized by a more general form of power-law decay, up to inverse time behavior associated with surface desorption. Solutions involve evaluating integrals where both numerators and denominators of the integrands diverge with time, making wide-ranging transient solutions difficult to directly compute numerically. Usually, one can avoid evaluating these integrals by assuming quasistatic conditions at long time scales. A novel approach is used in this work to analytically produce solutions by generating bespoke mathematical functions, some of which solve integrals that have apparently had no previous analytical solution."

Michael Woronowicz↗

PERFORMANCE CHARACTERISTICS OF A VECTOR SENSOR ARRAY IN AN ENERGETIC TIDAL CHANNEL

A compact three-dimensional vector sensor array (termed the NoiseSpotter) was recently developed with the goal of characterizing and localizing sources of sound in energetic environments such as those where marine renewable energy devices are likely to be located. The three vector sensors on the NoiseSpotter are mounted on a bottom platform with each sensor suspended inside an optional flow noise removal shield. The multiple pressure and particle velocity channels on the NoiseSpotter are simultaneously sampled and stored on-board to enable coherent array processing of vector sensor array data. A series of field trials were conducted where the NoiseSpotter was deployed on a bottom platform in an 8 m deep tidal channel in Sequim Bay, Washington. Pure tones were transmitted from a drifting vessel whose distance from the bottom platform varied between 50 m and 500 m. The effect of flow noise on vector sensor array performance is quantified along with the detectability of low intensity sound in an energetic environment. Flow noise removal efficiency for each channel of every vector sensor is demonstrated using multiple metrics derived from the active and reactive intensities computed using the pressure-velocity cross-spectral density matrix. A flow noise removal shield is shown to improve the detectability of low intensity sound such as those that are expected to be emitted by marine renewable energy devices.

Raghukumar, Kaustubha↗

Integral Measurement of the 237 Np($n$, γ) 238 Np Cross Section with Fast Neutrons

Accurate knowledge of the 237 Np($n$; γ) 238 Np cross section at fast neutron energies is important for applied nuclear science. The presently available experimental data has large disagreements in the fast neutron region. A measurement of the 237 Np($n$; γ) 238 Np cross section was performed using a well characterized fast neutron source and the results was compared with previous measurements and current nuclear data evaluations. This will provide an integral measurement that can be used as a benchmark for current evaluations. Multiple samples of 237 Np were irradiated in the Godiva-IV critical assembly. Following the irradiation, the samples placed in a γ-ray counting setup and the γ-rays emitted from the decay of 238 Np were measured over a time period of approximately 7 days. Multiple γ-ray decay branches of 238 Np were observed. The observed activity of 238 Np was used to calculate the amount of 238 Np produced during the irradiation via the 237 Np($n$; γ) 238 Np and an integral cross section of 359(10) mb was measured. The 238 Np half-life has been measured with a result of 50.34(7) hours. An integral measurement of the 237 Np($n$; γ) 238 Np cross section has been measured. This result has been compared to the calculated integral cross section using the ENDF/BVIII.0 and JENDL-4.0 evaluated cross sections and found to be in good agreement with ENDF/BVIII.0 value of 367 mb. The JENDL-4.0 evaluation yields a value of 312 mb, which is significantly lower than the measured cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Decommissioning of obsolete Nuclear Facilities in the UJV Rez, a. s. - 19027

UJV Rez, a. s. (further also UJV) is a leading institution in all areas of nuclear R and D in the Czech Republic and has had a dominant position in the nuclear program since it was established in 1955 as the Nuclear Research Institute Rez. The activities of UJV encompass nuclear physics, chemistry, nuclear power and many other topics. The main issues addressed at UJV in past decades have included research, development and services for NPPs, the fuel cycle and irradiation services for research and development in the industrial sector and medicine. UJV also manages most institutional radioactive wastes (RAW) produced in the Czech Republic (approx. 90 %). After more than 60 years of activities of the UJV in the nuclear field, there were obsolete nuclear facilities to be decommissioned. Decommissioning of nuclear facilities UJV is the only ongoing decommissioning project in the Czech Republic. Preparations for decommissioning began in 1996. Safety analysis report (SAR) was performed comprising the identification and characterization of potential sources of risk, potentially exposed receptors and exposure pathways, potential chemical compounds, radionuclides and media of concern. The results of the SAR enabled to determine the priorities of the decommissioning, the decommissioning the expenses and as well as project implementation. The decommissioning project was revised on the base of information obtained during decommissioning. The decommissioning was divided into two phases according to the level of risk and the financing limitations. The Ministry of Finance significantly financially contributed the decommissioning, although the UJV also contributed a considerable amount. Overall cost is close to the amount of Eur 27 million. Decommissioning started in 2003 and will be finished in 2018. Almost all facilities have already been successfully decommissioned. In the following table, the status of decommissioning of facilities is described. 1) Reloading site for RAW storage (Building 211/6): last item in progress 2003 - 2018; 2) Special Sewage System: decommissioned 2004 - 2005, reused; 3) Liquid RAW storage tanks (Building 211/3): decontaminated 2004 - 2013, reused; 4) Technology for RAW treatment (Building 241): decommissioned 2003 - 2011; 5) Contaminated equipment (Building 250): decommissioned 2003 - 2016; 6) Systems for storage of sealed sources (Building 261); decommissioned 2003 - 2005; 7) Decay tanks (Building 211/5); decommissioned 2003 - 2014, reused; 8) Old bituminating unit (Building 211/3); decommissioned 2004 - 2008; 9) Surface RAW storage site; decommissioned 2009 - 2014. Later, other unused decommissioning facilities, which were not included in the decommissioning project financed by the state, were included. These facilities are continuously decommissioned and financed from own resources of UJV. These facilities are like facilities already decommissioned: radiochemical laboratories, (including glove boxes), liquid RW storage tanks (including sewage systems), liquid RW treatment technology, hot cells, accumulated RW, etc. Realization started 2016 and expected duration is till 2026. Estimated budget is approximately Eur 17 million. The decommissioning of nuclear facilities in UJV is being carried out on the high level of radiation protection and up to now there was no extraordinary event or accident, although some challenges we were forced to address. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved Regional Moment Tensor Inversion for Moderately Large Earthquakes in the Western United States Using a 3D Earth Model Based on Full Waveform Tomography

The nature of seismic sources for moderately large (moment magnitude, M w 5.0–6.5) events are commonly characterized by their moment tensor (MT) solutions and obtained by inversion of regional distance (200–1600 km) long‐period (20–50 s) waveforms. Regional MT estimates are often calculated from average plane‐layered, one‐dimensional (1D) velocity models. However, 1D model calculations can produce misfits in the arrival times and waveform shapes that introduce errors, particularly at longer distances or for shorter periods, which are necessary for analyzing lower magnitude events. Approximate Earth models (e.g., 1D) representing broad areas may be inadequate, particularly in the crust and uppermost mantle of tectonically complex regions. In this study, we show how a three‐dimensional (3D) Earth model obtained from full waveform inversion tomography can improve waveform fits and decrease phase errors. We developed a platform and workflow to perform routine 3D MT inversions and inverted MTs for 25 earthquakes in the western United States and seven nuclear explosions using an average 1D and a recent 3D Earth model, WUS256 (Rodgers et al., 2022). Using the 3D model improves waveform fits (variance reduction and phase time shifts) compared with the 1D model, and the 3D MT solutions are stable across large distances. This study shows that 3D models obtained from full waveform tomography can improve MTs and source characterization especially at far regional distances (>800 km).

Geosciences↗

A stress-induced source of phonon bursts and quasiparticle poisoning

Abstract The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called “quasiparticle poisoning”. Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications

Numerous x-ray diagnostics at the Z facility, time-resolved and time-integrated, would benefit from a local calibrated x-ray source. For many years, Z has used low-power Manson x-ray sources to provide some characterization information for components of Z diagnostics below 30 keV. More recently, we have acquired TruFocus x-ray sources, which operate at voltages up to 100 kV depending on the anode material and model. These DC sources have demonstrated good stability and repeatability. Absolute calibrations of either sources or detectors usually involve another calibrated detector from another source, which has not been readily available locally. Therefore, we have adopted the strategy of characterizing a sensitive semiconductor diode detector by controlling or inferring the active volume. This characterized detector is then used to scale the Manson x-ray spectral shape as measured by an Amptek energy-resolving detector. Here, the result agrees well with the modeled source spectrum. We can apply this technique to the TruFocus as well.

Crystal spectroscopy↗

Investigation of the Carbon Arc Source as an AM0 Solar Simulator for Use in Characterizing Multi-Junction Solar Cells

The operation of multi-junction solar cells used for production of space power is critically dependent on the spectral irradiance of the illuminating light source. Unlike single-junction cells where the spectral irradiance of the simulator and computational techniques may be used to optimized cell designs, optimization of multi-junction solar cell designs requires a solar simulator with a spectral irradiance that closely matches AM0.

Xu, Jianzeng↗

VLBI2010 Imaging and Structure Corrections

Simulations show that the next generation VLBI system is generally well suited for imaging extragalactic radio sources. In addition to revealing the morphology of the sources, simulated VLBI2010 images may also be used to generate structure correction maps, which characterize the impact of source structure on the VLBI measurements. By comparing structure corrections for a set of simulated images based on Monte-Carlo generated visibilities with theoretical structure corrections derived from the model, we assess the accuracy of VLBI2010 structure corrections. In the most favorable case (32-station network, source at declination +40 deg.), statistics demonstrate that the structure corrections obtained from simulated images are statistically close to the theoretical model ones, which seems very promising for the VLBI2010 system.

Collioud, Arnaud↗

A Robust Waveguide Millimeter-Wave Noise Source

This paper presents the design, fabrication, and characterization of a millimeter-wave noise source for the 160- 210 GHz frequency range. The noise source has been implemented in an E-split-block waveguide package and the internal circuitry was developed on a quartz substrate. The measured excess noise ratio at 200 GHz is 9.6 dB.

Calibrating↗

Characterization of a Low-Temperature Plasma (LTP) Ambient Ionization Source Using Temporally Resolved Monochromatic Imaging Spectrometry

The low-temperature plasma (LTP) probe is a common plasma-based source used for ambient desorption–ionization mass spectrometry (MS). While the LTP probe has been characterized in detail with MS, relatively few studies have used optical spectroscopy. In this paper, two-dimensional (2D) imaging at selected wavelengths is used to visualize important species in the LTP plasma jet. First, 2D steady-state images of the LTP plume for N 2 + (391.2 nm), He I (706.5 nm), and N 2 (337.1 nm) emissions were recorded under selected plasma conditions. Second, time-resolved 2D emission maps of radiative species in the LTP plasma jet were recorded through the use of a 200 ns detection gate and varying gate delays with respect to the LTP trigger pulse. Emission from He I, N 2 + , and N 2 in the plasma jet region was found to show a transient behavior (often referred to as plasma bullets) lasting only a few microseconds. The N 2 + and He I maps were highly correlated in spatial and temporal structure. Further, emission from N 2 showed two maxima in time, one before and one after the maximum emission for N 2 + and He I, due to an initial electronic excitation wave and ion–electron recombination, respectively. Third, the interaction of the LTP probe with a sample substrate and an electrically grounded metallic needle was studied. Emission from a fluorophore on the sample substrate showed an initial photon-induced excitation from plasma-generated photons followed by electronic excitation by other plasma species. The presence of a grounded needle near the plasma jet significantly extended the plasma jet lifetime and also generated a long-lived corona discharge on the needle. The effect of LTP operating parameters on emission spectra was correlated with mass-spectral results including reagent-ion signals. Lastly, five movies provide a side-by-side comparison of the temporal behavior of emitting species and insights into the interactions of the emission clouds with a sample surface as well as an external needle. Temporally and spatially resolved imaging provided insights into important processes in the LTP plasma jet, which will help improve analyte ion sampling in LTP–MS.

Chan, George C. -Y.↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

A model of quasi-stellar radio sources.

Theoretical model for quasars characterizes them as galactic flares, based on study of high energy phenomena associated with solar flares

QUASI-STELLAR RADIO SOURCE /QSO/↗