Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Common femtoscopic hadron-emission source in pp collisions at the LHC

The femtoscopic study of pairs of identical pions is particularly suited to investigate the effective source function of particle emission, due to the resulting Bose–Einstein correlation signal. In small collision systems at the LHC, pp in particular, the majority of the pions are produced in resonance decays, which significantly affect the profile and size of the source. In this work, we explicitly model this effect in order to extract the primordial source in pp collisions at $\sqrt{s}$ = 13 TeV from charged π–π correlations measured by ALICE. We demonstrate that the assumption of a Gaussian primordial source is compatible with the data and that the effective source, resulting from modifications due to resonances, is approximately exponential, as found in previous measurements at the LHC. The universality of hadron emission in pp collisions is further investigated by applying the same methodology to characterize the primordial source of K–p pairs. The size of the primordial source is evaluated as a function of the transverse mass (m T ) of the pairs, leading to the observation of a common scaling for both π–π and K–p, suggesting a collective effect. Further, the present results are compatible with the m T scaling of the p–p and p–Λ primordial source measured by ALICE in high multiplicity pp collisions, providing additional evidence for the presence of a common emission source for all hadrons in small collision systems at the LHC. This will allow the determination of the source function for any hadron–hadron pairs with high precision, granting access to the properties of the possible final-state interaction among pairs of less abundantly produced hadrons, such as strange or charmed particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of a gamma-ray tracking array: Characterizing the AGATA array using a 60 Co source

The AGATA (Advanced GAmma Tracking Array) tracking detector is being designed to far surpass the performance of the previous generation, Compton-suppressed arrays. In this paper, a characterization of AGATA is provided based on data from the second GSI campaign. Emphasis is placed on the proper corrections required to extract the absolute photopeak efficiency and peak-to-total ratio. The performance after tracking is extracted and GEANT4 simulations are used both to understand the results and to scale the measurements up to predicted values for the full 4 implementation of the device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Brazilian Tension Results on Core from Borehole U-15n, NNSS, in support of SPE

Dynamic Brazilian tension (DBR) tests from core hole U-15n are part of a larger material characterization effort for the Source Physics Experiment (SPE) project. This larger effort encompasses characterizing Climax Stock granite rock from the Nevada National Security Site (NNSS) both before and after each SPE shot. The current test series includes DBR tests on dry intact granite and fault material at depths of -85 and -150 ft.

36 MATERIALS SCIENCE↗

Triaxial Compression Results on Core from Borehole U-15n, NNSS, in support of SPE

Triaxial compression tests from core hole U-15n are part of a larger material characterization effort for the Source Physics Experiment (SPE) project. This larger effort encompasses characterizing Climax Stock granite rock from the Nevada National Security Site (NNSS) both before and after each SPE shot. The current test series includes triaxial compression tests on dry and saturated intact granite and fault material at 100, 200, 300, and 400 MPa confining pressure.

58 GEOSCIENCES↗

Aerial Lidar and Geomorphic Change Detection Software- Tools for Monitoring Canyon Sediments at LANL - 18668

The Los Alamos National Laboratory Environmental Remediation program has conducted extensive geomorphic surveys of sediment deposits in the canyon bottoms within and surrounding the facility. The goal of the geomorphic surveys was to provide basic information needed to characterize chemical inventories of the sediments downstream of historical release sites. Sediment units were mapped based on depositional setting and age. Representative characterization samples were collected for each unit and submitted for chemical analysis. Chemical inventories were estimated by calculating the total volume of each depositional unit and multiplying by average chemical concentration. This method of characterization provides a spatial distribution of chemical data based on fluvial processes. In general, for the canyon bottom sediments, the higher concentrations of industrial chemicals were associated with fine-grained floodplain deposits closest to the source. Since initial characterization, many of the reaches have undergone changes in response to post-wildfire floods and severe rain events. These events impacted the channel and floodplain deposits. Much of the elevated concentrations are confined to the over-bank deposits distal from the primary channel. In order to ensure that the sediment units containing elevated chemical concentrations are stable, repeat aerial light detection and ranging (LiDAR) surveys are conducted and changes are assessed using the Geomorphic Change Detection (GCD) plug-in for ArcGIS. These tools provide high confidence uncertainty estimates and extensive areal coverage. This is a valuable method for long-term monitoring of surface sediments with low-level but widespread contaminant distributions. All of the monitored canyon bottom reaches pass risk assessment and present technically infeasible sediment removal options. Following the 2014 monsoon season, aerial LiDAR data has been collected annually and the resulting digital elevation models (DEMs) processed using the GCD method. Changes are identified using GCD and are verified by field walk downs. If erosion is identified in areas which are vulnerable to mobilizing contaminated sediment, enhanced controls can be installed to stabilize banks or other areas with high erosion potential. Annual sediment monitoring samples are collected where there is evidence for flow and deposition within the past year. Since 2014, no severe floods have been catalogued using the LiDAR surveys and GCD software. The recent rainfall/runoff events have not caused major changes to the canyon bottom channels and floodplains. Geomorphic processes identified in the monitoring results include channel aggradation and incision that over the course of a monsoon season results in minor changes to the system. Other active processes contributing to observed changes are minor slides, flows, slumps, and falls of unconsolidated sediment on steep bedrock or soil surfaces. A comprehensive baseline has been established by geomorphic mapping and characterization sampling. Periodic monitoring consists of LiDAR surveys and GCD analysis which offers an effective and defensible methodology for documenting stability of surface sediments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrating Contaminant Source Indicators, Water Quality Measures, and Ecotoxicity to Characterize Contaminant Mixtures and Per- and Polyfluoroalkyl Substance (PFAS) Variability in an Urban Watershed

Thousands of chemical contaminants threaten watersheds but are time and cost prohibitive to monitor. Identifying their sources, transport, and ecological risk is limited in heterogeneous urban watersheds. We present an integrative watershed approach using source-specific indicator compounds, common water quality measures, and ecotoxicity assays to examine the distribution of contaminant mixtures in an urbanized watershed. Indicator compound concentrations were temporally and spatially distributed for treated/untreated sewage (sucralose, artificial sweetener), road runoff (diphenyl-guanidine [DPG] and 6PPD-quinone [6PPD-Q], automobile tire additives), and lawncare runoff (aminomethanephosphonic acid (AMPA), major degradant of the herbicide glyphosate). Sucralose was predominately sourced from treated wastewater; measurable concentrations in tributaries indicated raw sewage inputs. DPG and 6PPD-Q concentrations correlated to road density during base flow and were elevated during stormflow. AMPA was measurable spring through fall, especially where lawns were dense. When specific sources dominated flow, water quality measures correlated with wastewater (sulfate, potassium, chloride, and sodium) and road runoff (chromium and lead) indicators. The limited behavioral toxicity observed in exposed zebrafish (Danio rerio) (18%) was not well explained by source-indicators. PFAS concentrations were highly variable spatially but not well explained by our source-specific indicator compounds. Here, more costly compound-specific monitoring may be necessary when multiple sources exist or when unexpected toxicity trends occur.

computer simulations↗

Microplasma-based flowing atmospheric-pressure afterglow (FAPA) source for ambient desorption-ionization mass spectrometry

A new direct-current microplasma-based flowing atmospheric pressure afterglow (FAPA) source was developed for use in ambient desorption-ionization mass spectrometry. The annular-shaped microplasma is formed in helium between two concentric stainless-steel capillaries that are separated by an alumina tube. Current-voltage characterization of the source shows that this version of the FAPA operates in the normal glow-discharge regime. A glass surface placed in the path of the helium afterglow reaches temperatures of up to approximately 400 °C; the temperature varies with distance from the source and helium flow rate through the source. Solid, liquid, and vapor samples were examined by means of a timeof- flight mass spectrometer. Results suggest that ionization occurs mainly through protonation, with only a small amount of fragmentation and adduct formation. Here, the mass range of the source was shown to extend up to at least m/z 2722 for singly charged species. Limits of detection for several small organic molecules were in the sub-picomole range. Examination of competitive ionization revealed that signal suppression occurs only at high (mM) concentrations of competing substances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

Estimation of hydraulic conductivity in a watershed using sparse multi-source data via Gaussian process regression and Bayesian experimental design

Enhanced water management systems depend on accurate estimation of subsurface hydraulic properties. However, geologic formations can vary significantly, so information from a single source (e.g., widely spaced boreholes) is insufficient in characterizing subsurface aquifer properties. Therefore, multiple sources of information are needed to complement the hydrogeology understanding of a region. Here, this study presents a numerical framework in which information from different measurement sources is combined to characterize the 3D random field in a multi-fidelity prediction model. Coupled with the model, a Bayesian experimental design was used to determine the best future sampling locations. The Upper Sangamon watershed in east-central Illinois was selected as the case study site, where the multi-fidelity Gaussian process model was used to estimate the hydraulic conductivity in the region of interest. Multi-source observation data were obtained from electrical resistivity and borehole pumping tests. The accuracy of the model prediction is dependent on the locations and the distribution of both high- and low-fidelity data. Furthermore, the multi-fidelity model was compared with the single-fidelity model. The uncertainties and confidence in the measurements and parameter estimates were quantified and used to design future cycles of data collection to further improve the confidence intervals.

54 ENVIRONMENTAL SCIENCES↗

γ-Fe{sub 2}O{sub 3} nanoparticles: An easily recoverable effective photo-catalyst for the degradation of rose bengal and methylene blue dyes in the waste-water treatment plant

Graphical abstract: - Highlights: • γ-Fe{sub 2}O{sub 3} NPs from a single-source precursor and characterized by XRD, TEM, UV–vis spectra. • The NPs were tested as effective photocatalyst toward degradation of RB and MB dyes. • The possible pathway of the photocatalytic decomposition process has been discussed. • The active species, OH·, was detected by TA photoluminescence probing techniques. - Abstract: γ-Fe{sub 2}O{sub 3} nanoparticles (NPs) were synthesized from a single-source precursor complex [Fe{sub 3}O(C{sub 6}H{sub 5}COO){sub 6}(H{sub 2}O){sub 3}]NO{sub 3} by a simple thermal decomposition process and have been characterized by X-ray diffraction analysis (XRD), transmission electron microscopy (TEM) and UV–vis spectroscopic techniques. The NPs were highly pure and well crystallized having hexagonal morphology with an average particle size of 35 nm. The prepared γ-Fe{sub 2}O{sub 3} (maghemite) NPs show effective photo-catalytic activity toward the degradation of rose bengal (RB) and methylene blue (MB) dyes under visible light irradiation and can easily be recoverable in the presence of magnetic field for successive re-uses. The possible photo-catalytic decomposition mechanism is discussed through the detection of hydroxyl radical (OH·) by terephthalic acid photo-luminescence probing technique.

36 MATERIALS SCIENCE↗

Panax quinquefolius (North American ginseng) cell suspension culture as a source of bioactive polysaccharides: Immunostimulatory activity and characterization of a neutral polysaccharide AGC1

In this study, we propose the use of a plant tissue culture-based system for the production of polysaccharides with consistent chemical characteristics and reduced endotoxin content. Polysaccharides were isolated from suspension cultures of Panax quinquefolius (American ginseng), a widely used medicinal herb. A neutral fraction, AGC1, purified by anion exchange and size exclusion chromatography, displayed immunostimulatory activity in vitro and ex vivo. AGC1 (average molecular weight: 5.2 kDa) was predominantly composed of galactose (>60%) along with the presence of several other neutral sugars such as arabinose, xylose, glucose, mannose and rhamnose in minor amounts. The major glycosidic linkages were found to be 3-Galp (48.5%), 3,6-Galp (10.2%), t-Galp (5.2%), 6-Galp (4.4%), 4-Glcp (5.7%), 4-Arap/5-Araf (4.0%) and t-Araf (4.5%). AGC1 significantly (p < 0.05) stimulated the expression of a range of proinflammatory mediators in RAW 264.7 murine macrophages such as IL-6, TNF-α, MCP-1 and GM-CSF. Additionally, AGC1 treatment of RAW 264.7 cells stimulated NOS2 gene expression, leading to increased levels of iNOS and downstream NO. Consistent with this, AGC1 was able to act as an immunostimulant in primary murine splenocytes, enhancing cell proliferation, as well as NO and TNF-α production. Our results also indicate the partial role of NF-κB pathway in the immunostimulatory response.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization with dense array data of seismic sources in the shallow part of the San Jacinto fault zone

SUMMARY We analyse dominant sources identified in a catalogue of more than 156 000 localizations performed using a 26-d data set recorded by a dense array set on the San Jacinto fault near Anza, in California. Events were localized using an array processing technique called Match Field Processing. As for all array processing techniques, the quality of the event position decrease when the events are outside of the array. We thus separate localizations in and outside the array using simple geometrical conditions. We compare the time distribution of the localization to additional data such as meteorological data, day of human activity as well as existing catalogues to determine the nature of the dominant events located using our method. We find that most of the events located outside of the array could be attributed to a surface structure excited by wind. On the other hand, part of the localizations under the array occur during regional earthquakes and could correspond to diffraction on the fault's heterogeneities. The rest of the localizations inside the array could be generated by the fault itself.

Geochemistry & Geophysics↗

Quantifying rupture characteristics of microearthquakes in the Parkfield Area using a high-resolution borehole network

It is well known that large earthquakes often exhibit significant rupture complexity such as well separated subevents. With improved recording and data processing techniques, small earthquakes have been found to exhibit rupture complexity as well. Studying these small earthquakes offers the opportunity to better understand the possible causes of rupture complexities. Specifically, if they are random or are related to fault properties. We examine microearthquakes (M < 3) in the Parkfield, California, area that are recorded by a high-resolution borehole network. We quantify earthquake complexity by the deviation of source time functions and source spectra from simple circular (omega-square) source models. We establish thresholds to declare complexity, and find that it can be detected in earthquakes larger than magnitude 2, with the best resolution above M2.5. Comparison between the two approaches reveals good agreement (>90 per cent), implying both methods are characterizing the same source complexity. For the two methods, 60–80 per cent (M 2.6–3) of the resolved events are complex depending on the method. The complex events we observe tend to cluster in areas of previously identified structural complexity; a larger fraction of the earthquakes exhibit complexity in the days following the M w 6 2004 Parkfield earthquake. Ignoring the complexity of these small events can introduce artefacts or add uncertainty to stress drop measurements. Focusing only on simple events however could lead to systematic bias, scaling artefacts and the lack of measurements of stress in structurally complex regions.

58 GEOSCIENCES↗

Characterization of a cold cathode Penning ion source for the implantation of noble gases beneath 2D monolayers on metals: Ions and neutrals

Argon ion kinetic energy spectra at different discharge voltages (between 480 and 600 V) of a commercial cold cathode ion source IQP10/63 are reported. The high kinetic energy cut-off depends on the discharge voltage and the corresponding plasma potential due to excess positive charges which is found to be about 136 V. Exposure of single layer hexagonal boron nitride on rhodium to the beam of the ion source leads to the formation of nanotents, i.e., stable atomic protrusions. A positive bias voltage is applied to the target sample to block the positive ions produced by the ion source. However, application of a positive bias potential (800 eV), which is higher than the kinetic energy cut-off, still allows the formation of nanotents and its observation with scanning tunneling microscopy. This indicates that the ion source also produces neutral atoms with kinetic energies higher than the penetration threshold across a single layer of hexagonal boron nitride.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pathosphere.org: pathogen detection and characterization through a web-based, open source informatics platform

The detection of pathogens in complex sample backgrounds has been revolutionized by wide access to next-generation sequencing (NGS) platforms. However, analytical methods to support NGS platforms are not as uniformly available. Pathosphere (found at Pathosphere.org) is a cloud - based open - sourced community tool that allows for communication, collaboration and sharing of NGS analytical tools and data amongst scientists working in academia, industry and government. The architecture allows for users to upload data and run available bioinformatics pipelines without the need for onsite processing hardware or technical support. The pathogen detection capabilities hosted on Pathosphere were tested by analyzing pathogen-containing samples sequenced by NGS with both spiked human samples as well as human and zoonotic host backgrounds. Pathosphere analytical pipelines developed by Edgewood Chemical Biological Center (ECBC) identified spiked pathogens within a common sample analyzed by 454, Ion Torrent, and Illumina sequencing platforms. ECBC pipelines also correctly identified pathogens in human samples containing arenavirus in addition to animal samples containing flavivirus and coronavirus. These analytical methods were limited in the detection of sequences with limited homology to previous annotations within NCBI databases, such as parvovirus. Utilizing the pipeline-hosting adaptability of Pathosphere, the analytical suite was supplemented by analytical pipelines designed by the United States Army Medical Research Institute of Infectious Diseases and Walter Reed Army Institute of Research (USAMRIID-WRAIR). These pipelines were implemented and detected parvovirus sequence in the sample that the ECBC iterative analysis previously failed to identify. By accurately detecting pathogens in a variety of samples, this work demonstrates the utility of Pathosphere and provides a platform for utilizing, modifying and creating pipelines for a variety of NGS technologies developed to detect pathogens in complex sample backgrounds. These results serve as an exhibition for the existing pipelines and web-based interface of Pathosphere as well as the plug-in adaptability that allows for integration of newer NGS analytical software as it becomes available.

59 BASIC BIOLOGICAL SCIENCES↗