Search NASA⌕ Search

SEARCH · Search NASA

Results for “source identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Computer-aided classification of suspicious pigmented lesions using wide-field images

Early identification of melanoma is conducted through whole-body visual examinations to detect suspicious pigmented lesions, a situation that fluctuates in accuracy depending on the experience and time of the examiner. Computer-aided diagnosis tools for skin lesions are typically trained using pre-selected single-lesion images, taken under controlled conditions, which limits their use in wide-field scenes. Here, we propose a computer-aided classifier system with such input conditions to aid in the rapid identification of suspicious pigmented lesions at the primary care level. 133 patients with a multitude of skin lesions were recruited for this study. All lesions were examined by a board-certified dermatologist and classified into “suspicious” and “non-suspicious”. A new clinical database was acquired and created by taking Wide-Field images of all major body parts with a consumer-grade camera under natural illumination condition and with a consistent source of image variability. 3–8 images were acquired per patient on different sites of the body, and a total of 1759 pigmented lesions were extracted. A machine learning classifier was optimized and build into a computer aided classification system to binary classify each lesion using a suspiciousness score. In a testing set, our computer-aided classification system achieved a sensitivity of 100% for suspicious pigmented lesions that were later confirmed by dermoscopy examination (“SPL_A”) and 83.2% for suspicious pigmented lesions that were not confirmed after examination (“SPL_B”). Sensitivity for non-suspicious lesions was 72.1%, and accuracy was 75.9%. With these results we defined a suspiciousness score that is aligned with common macro-screening (naked eye) practices. This work demonstrates that wide-field photography combined with computer-aided classification systems can distinguish suspicious from non-suspicious pigmented lesions, and might be effective to assess the severity of a suspicious pigmented lesions. We believe this approach could be useful to support skin screenings at a population-level.

60 APPLIED LIFE SCIENCES↗

Why Is Attention Sparse In Particle Transformer?

Transformer-based models have achieved state-of-the-art performance in jet tagging at the CERN Large Hadron Collider (LHC), with the Particle Transformer (ParT) representing a leading example of such models. A striking feature of ParT is its sparse, nearly binary, attention structure, raising questions about the origin of this behavior and whether it encodes physically meaningful correlations. In this work, we investigate the source of ParT's sparse attention by comparing models trained on multiple benchmark datasets and examine the relative contributions of the attention term and the physics-inspired interaction matrix before softmax. We find that binary sparsity arises primarily from the attention mechanism itself, with the interaction matrix playing a secondary role. Moreove, we show that ParT is able to identify key jet substructure elements, such as leptons in semileptonic top decays, even without explicit particle identification inputs. These results provide new insight into the interpretability of transformer-based jet taggers and clarify the conditions under which sparse attention patterns emerge in ParT.

Legge, Timothy [UC, San Diego]↗

Anomaly detection in the Zwicky Transient Facility DR3

We present results from applying the SNAD anomaly detection pipeline to the third public data release of the Zwicky Transient Facility (ZTF DR3). The pipeline is composed of three stages: feature extraction, search of outliers with machine learning algorithms, and anomaly identification with followup by human experts. Our analysis concentrates in three ZTF fields, comprising more than 2.25 million objects. A set of four automatic learning algorithms was used to identify 277 outliers, which were subsequently scrutinized by an expert. From these, 188 (68 per cent) were found to be bogus light curves – including effects from the image subtraction pipeline as well as overlapping between a star and a known asteroid, 66 (24 per cent) were previously reported sources whereas 23 (8 per cent) correspond to non-catalogued objects, with the two latter cases of potential scientific interest (e.g. one spectroscopically confirmed RS Canum Venaticorum star, four supernovae candidates, one red dwarf flare). Moreover, using results from the expert analysis, we were able to identify a simple bi-dimensional relation that can be used to aid filtering potentially bogus light curves in future studies. We provide a complete list of objects with potential scientific application so they can be further scrutinised by the community. These results confirm the importance of combining automatic machine learning algorithms with domain knowledge in the construction of recommendation systems for astronomy. Our code is publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct time-resolved detection and quantification of key reactive intermediates in diethyl ether oxidation at T = 450–600 K

High-pressure multiplexed photoionization mass spectrometry (MPIMS) with tunable vacuum ultraviolet (VUV) ionization radiation from the Lawrence Berkeley Labs Advanced Light Source is used to investigate the oxidation of diethyl ether (DEE). Kinetics and photoionization (PI) spectra are simultaneously measured for the species formed. Several stable products from DEE oxidation are identified and quantified using reference PI cross-sections. In addition, we directly detect and quantify three key chemical intermediates: peroxy (ROO˙), hydroperoxyalkyl peroxy (˙OOQOOH), and ketohydroperoxide (HOOP[double bond, length as m-dash]O, KHP). These intermediates undergo dissociative ionization (DI) into smaller fragments, making their identification by mass spectrometry challenging. Furthermore, with the aid of quantum chemical calculations, we identify the DI channels of these key chemical species and quantify their time-resolved concentrations from the overall carbon atom balance at T = 450 K and P = 7500 torr. This allows the determination of the absolute PI cross-sections of ROO˙, ˙OOQOOH, and KHP into each DI channel directly from experiment. The PI cross-sections in turn enable the quantification of ROO˙, ˙OOQOOH, and KHP from DEE oxidation over a range of experimental conditions that reveal the effects of pressure, O 2 concentration, and temperature on the competition among radical decomposition and second O 2 addition pathways.

42 ENGINEERING↗

Ranking Biological Features in Soil-Based Microbial Multi-Omics Data with Integration Modeling

Distinguishing the most important features (e.g. proteins, metabolites, etc.) per group (e.g. control and treatment) is a critical challenge in feature-rich multi-omics experiments, especially in soil data. Traditional feature identification and ranking approaches, such as differential expression, are based on single omics and thus not directly translatable to multi-omics experiments. Here, 5 multi-omics integration models (DIABLO, JACA, MOFA, MultiMLP, and SLIDE) that were not explicitly built for soil data applications were tested using a soil-based multi-omics experiment. The data were obtained from an experimental setup of an autoclaved soil system inoculated with 8 bacteria and using chitin as the carbon source and including samples collected at 0- (control), 4-, 8-, and 12-weeks post-inoculation. The omics data included metaproteomics, 16S rRNA sequencing, and LC-MS/MS metabolomics (in positive and negative mode). Each multi-omics integration model was implemented, and top features were compared to differential univariate statistics per omic type, demonstrating that integration approaches cut the potential number of top features from 2957 identified by differential statistics to 13-224 (a 99.6% to 92.4% reduction). Interestingly, most top features across integration models were not shared; though, scaling and averaging ranks across models shared similar patterns. This work highlights the usefulness of multi-omics integration models in soil-based microbial studies and the power of using multiple integration models together to interpret results.

54 ENVIRONMENTAL SCIENCES↗

The Zwicky Transient Facility Bright Transient Survey. III. BTSbot: Automated Identification and Follow-up of Bright Transients with Deep Learning

Abstract The Bright Transient Survey (BTS) aims to obtain a classification spectrum for all bright ( m peak ≤ 18.5 mag) extragalactic transients found in the Zwicky Transient Facility (ZTF) public survey. BTS critically relies on visual inspection (“scanning”) to select targets for spectroscopic follow-up, which, while effective, has required a significant time investment over the past ∼5 yr of ZTF operations. We present BTSbot , a multimodal convolutional neural network, which provides a bright transient score to individual ZTF detections using their image data and 25 extracted features. BTSbot is able to eliminate the need for daily human scanning by automatically identifying and requesting spectroscopic follow-up observations of new bright transient candidates. BTSbot recovers all bright transients in our test split and performs on par with scanners in terms of identification speed (on average, ∼1 hr quicker than scanners). We also find that BTSbot is not significantly impacted by any data shift by comparing performance across a concealed test split and a sample of very recent BTS candidates. BTSbot has been integrated into Fritz and Kowalski , ZTF’s first-party marshal and alert broker, and now sends automatic spectroscopic follow-up requests for the new transients it identifies. Between 2023 December and 2024 May, BTSbot selected 609 sources in real time, 96% of which were real extragalactic transients. With BTSbot and other automation tools, the BTS workflow has produced the first fully automatic end-to-end discovery and classification of a transient, representing a significant reduction in the human time needed to scan.

Rehemtulla, Nabeel (ORCID:0000000256832389)↗

Fusion Energy Sciences Network Requirements Review. Final Report, April - October 2021

The Energy Sciences Network (ESnet) is the high-performance network user facility for the US Department of Energy (DOE) Office of Science (SC) and delivers highly reliable data transport capabilities optimized for the requirements of data-intensive science. In essence, ESnet is the circulatory system that enables the DOE science mission by connecting all of its laboratories and facilities in the US and abroad. ESnet is funded and stewarded by the Advanced Scientific Computing Research (ASCR) program and managed and operated by the Scientific Networking Division at Lawrence Berkeley National Laboratory (LBNL). ESnet is widely regarded as a global leader in the research and education networking community. Throughout 2021, ESnet and the Office of Fusion Energy Sciences (FES) of the DOE SC organized an ESnet requirements review of FES-supported activities. Preparation for these events included identification of key stakeholders: program and facility management, research groups, and technology providers. Each stakeholder group was asked to prepare formal case study documents about their relationship to the FES program to build a complete understanding of the current, near-term, and long-term status, expectations, and processes that will support the science going forward.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

nmRanalysis: An Open-Source Web Application for Semi-automated NMR Metabolite Profiling

Though data acquisition and initial signal pre-processing of nuclear magnetic resonance (NMR) spectra have achieved high degrees of automation, downstream processing - specifically the profiling of spectra - has bottlenecked the overall NMR analysis workflow. Several efforts have been made to mitigate this bottleneck, but these solutions often trade an increase in automation for limitations elsewhere. Here, in this technical note, we introduce nmRanalysis, a user-friendly web-application that integrates the strengths of existing profiling tools for a more automated profiling workflow. nmRa-nalysis additionally incorporates novel features, including a machine-learning-driven recommender system for me-tabolite identification, further increasing the utility of nmRanalysis over the individual tools that it incorporates.

Flores, Javier E. [Pacific Northwest National Labo↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving ProtoDUNE pion cross-section measurements with NuGraph Michel-electron tagging

Understanding hadron-argon interactions is essential for precise neutrino energy reconstruction and final-state interaction modeling in liquid-argon time projection chamber (LArTPC) experiments such as DUNE. In particular, pion absorption and charge-exchange processes constitute significant sources of systematic uncertainty in neutrino oscillation measurements. ProtoDUNE-SP, a large-scale LArTPC prototype operated at the CERN Neutrino Platform and exposed to charged-particle test beams in the few-GeV range, enables direct measurements of these processes. This work focuses on the measurement of differential cross sections for pion absorption and charge exchange using the 2 GeV/c pion beam data from the ProtoDUNE-SP run. A key component of this analysis is the identification of Michel electrons from $\pi \rightarrow \mu \rightarrow e$ decay chains, which helps separate different interaction topologies and improves background rejection. Michel electron identification will also assist in reliably calibrating the electromagnetic response in ProtoDUNE-SP data and for the future DUNE detectors. In this analysis, we apply NuGraph to identify Michel electrons. NuGraph is a graph neural network that models detector hits as nodes connected by spatial and temporal edges for particle and topology classification in LArTPC detectors. We first benchmark NuGraph’s Michel electron classification performance using ICEBERG data, a small-scale LArTPC prototype used for DUNE electronics and reconstruction development, and then transfer the approach to ProtoDUNE-SP. This poster presents the analysis strategy, NuGraph-based classification studies, and discusses how these developments are expected to improve the pion cross-section measurement.

Razafinime, Soamasina Herilala [Cincinnati U.] (OR↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Framework for assessing land‐management effects on at‐risk species: Example of SE USA wood pellet production and gopher tortoise ( Gopherus polyphemus )

Abstract Land‐management choices made for economic and societal gains intrinsically influence landscapes and species that are dependent upon them. We propose a simple analysis framework to examine critical intersections between land‐management choices and the life‐history conditions of selected species of concern, thereby facilitating the identification of mitigation practices that can reduce negative impacts on species at risk. We test the proposed framework through application to gopher tortoise ( Gopherus polyphemus ), a keystone species that is the focus of conservation efforts across the southeastern region of United States of America, where wood pellets are being produced for bioenergy. Production of these wood pellets for export to Europe and Asia has drastically increased in the past decade, raising concerns about potential harm to biodiversity since many species in the forests sourcing pellet production were already at risk prior to the development of this new commodity. Identifying the mechanisms of potential impacts of wood pellet production on species of concern is essential to establishing meaningful management recommendations that can enhance conservation efforts while supporting sustainable bioenergy. By considering the intersections between life‐history conditions of gopher tortoise and forest‐management practices related to woody biomass extraction for pellet production, we identify several mechanisms by which the wood‐pellet industry might affect this species of concern, both positively and negatively. We then identify mitigation practices that can help offset the potential impacts of logging, thinning, and dead wood removal on gopher tortoise. Our analysis framework may be transferable to other species of concern and land‐management practices across diverse landscapes. This article is categorized under: Bioenergy > Economics and Policy Bioenergy > Climate and Environment

54 ENVIRONMENTAL SCIENCES↗

Power System Frequency Dynamics Modeling, State Estimation, and Control using Neural Ordinary Differential Equations (NODEs) and Soft Actor-Critic (SAC) Machine Learning Approaches

With the global energy transition of the electric power system, grid control, supervision, and protection is becoming more challenging. With the increasing integration of renewable energy sources (RES), the system dynamics are changing, causing traditional power system dynamic modeling with swing equation-based modeling approaches to fail. Additionally, the converter-dominated power grid is decreasing the system inertia, making the power system more fragile to the frequency swings. This paper first investigates and compares the application of a model-based Kalman filter state estimation approach with (i) a model-free machine learning approach --- neural ordinary differential equations (NODEs) --- and (ii) a data-driven system identification (SysId) approach to model and infer critical state values of the power system frequency dynamics. Then a model predictive control (MPC) framework is compared to a model-free Soft Actor-Critic (SAC) reinforcement learning (RL) control algorithm in providing efficient fast frequency response (FFR) to the power system frequency dynamics. The approaches are compared in terms of their performance goals as well as their per-timestep computational efficiency. Furthermore, the comparative study for state estimation shows that for the model-free requirement, both NODEs and SysId can provide accurate state estimates; however, with increasing model complexity, NODEs can be a better choice for model identification. Similarly, the results from the FFR comparative study show that the SAC RL-based FFR, once trained, outperforms MPC with better control signals and faster computation time, making the SAC RL-based FFR better option for providing FFR to the power system.

97 MATHEMATICS AND COMPUTING↗

Solar water splitting Pt-nanoparticle photosystem I thylakoid systems: Catalyst identification, location and oligomeric structure

In this study, photosynthetic conversion of light energy into chemical energy occurs in sheet-like membrane-bound compartments called thylakoids and is mediated by large integral membrane protein-pigment complexes called reaction centers (RCs). Oxygenic photosynthesis of higher plants, cyanobacteria and algae requires the symbiotic linking of two RCs, photosystem II (PSII) and photosystem I (PSI), to split water and assimilate carbon dioxide. Worldwide there is a large research investment in developing RC-based hybrids that utilize the highly evolved solar energy conversion capabilities of RCs to power catalytic reactions for solar fuel generation. Of particular interest is the solar-powered production of H 2 , a clean and renewable energy source that can replace carbonbased fossil fuels and help provide for ever-increasing global energy demands. Recently, we developed thylakoid membrane hybrids with abiotic catalysts and demonstrated that photosynthetic Z-scheme electron flow from the light-driven water oxidation at PSII can drive H 2 production from PSI. One of these hybrid systems was created by self-assembling Pt-nanoparticles (PtNPs) with the stromal subunits of PSI that extend beyond the membrane plane in both spinach and cyanobacterial thylakoids. Using PtNPs as site-specific probe molecules, we report the electron microscopic (EM) imaging of oligomeric structure, location and organization of PSI in thylakoid membranes and provide the first direct visualization of photosynthetic Z-scheme solar water-splitting biohybrids for clean H 2 production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A goldilocks computational protocol for inhibitor discovery targeting DNA damage responses including replication-repair functions

While many researchers can design knockdown and knockout methodologies to remove a gene product, this is mainly untrue for new chemical inhibitor designs that empower multifunctional DNA Damage Response (DDR) networks. Here, we present a robust Goldilocks (GL) computational discovery protocol to efficiently innovate inhibitor tools and preclinical drug candidates for cellular and structural biologists without requiring extensive virtual screen (VS) and chemical synthesis expertise. By computationally targeting DDR replication and repair proteins, we exemplify the identification of DDR target sites and compounds to probe cancer biology. Our GL pipeline integrates experimental and predicted structures to efficiently discover leads, allowing early-structure and early-testing (ESET) experiments by many laboratories. By employing an efficient VS protocol to examine protein-protein interfaces (PPIs) and allosteric interactions, we identify ligand binding sites beyond active sites, leveraging in silico advances for molecular docking and modeling to screen PPIs and multiple targets. A diverse 3,174 compound ESET library combines Diamond Light Source DSI-poised, Protein Data Bank fragments, and FDA-approved drugs to span relevant chemotypes and facilitate downstream hit evaluation efficiency for academic laboratories. Two VS per library and multiple ranked ligand binding poses enable target testing for several DDR targets. This GL library and protocol can thus strategically probe multiple DDR network targets and identify readily available compounds for early structural and activity testing to overcome bottlenecks that can limit timely breakthrough drug discoveries. By testing accessible compounds to dissect multi-functional DDRs and suggesting inhibitor mechanisms from initial docking, the GL approach may enable more groups to help accelerate discovery, suggest new sites and compounds for challenging targets including emerging biothreats and advance cancer biology for future precision medicine clinical trials.

59 BASIC BIOLOGICAL SCIENCES↗

Boron nitride neutron detector with the ability for detecting both thermal and fast neutrons

The detection of fast neutrons is regarded technically challenging because the interaction probability of fast neutron with matter is extremely low. Based on our recent development of hexagonal boron nitride (BN) semiconductor thermal neutron detectors with a record high efficiency of 59%, we report here the feasibility studies of BN detectors for detecting fast neutrons. A BN detector with a detection area of 2.1 cm 2 was fabricated from a 90 $μ$m thick BN epilayer. In the presence of a bare Cf-252 source emitting fast neutrons ranging from 1 to 9 MeV, the detection efficiency was estimated to be about 0.1%. Furthermore, the measured mean free path of fast neutron in BN is about 7.6 cm. Together with the capability of BN for thermal neutron detection, the present results indicate that by incorporating BN with a large thickness, BN neutron detectors are expected to possess the unique capability of directly detecting thermal to fast neutrons as well as outstanding features resulting from the ultrawide bandgap of BN. The identification of a single material that is sensitive to both thermal and fast neutrons is valuable for the development of novel neutron detection technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗